• Title/Summary/Keyword: rate-sensitive

Search Result 1,568, Processing Time 0.031 seconds

Finite Element Analysis with Viscoplastic Formulation in Open-Die RTP Process (개방형 RTP(Rapid Thermal Pressing)공정의 점소성 유한요소해석)

  • Son J. W.;Rhim S. H.;Oh S. I.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.284-289
    • /
    • 2004
  • Since polymer materials at elevated temperatures are usually rate-sensitive, the analysis of RTP process requires considering the effect of the rate-dependent. The material behavior that exhibits rate-sensitivity is called visco-plastic. A two-dimensional visco-plastic finite element formulation which constitutive equation is based on the formulation proposed by Perzyna is presented. This Paper is purposed to calcuate pressure distribution on PMMA in compression process and to predict the relationship with defects after demolding process. This paper analyzes, both analytically and numerically, the pressure distributions on the surface of PMMA during open-die RTP process. In this research, PMMA is used to be simulated at $110^{\circ}C$ near the transition temperature.

  • PDF

A Study of surfactant-based remediation for removal of toluene and PCE in contaminated water

  • Kim, Eun-Sik;Lee, Dal-Heui;Chang, Ho-Wan
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.302-305
    • /
    • 2003
  • The purpose of this study was to assess the effect of surfactant on the rate of NAPLs(non-aqueous phase liquids) solubilization. The experimental variables were surfactant type, NAPLs type and water type. The main experimental designs were consists of two phases. The solubilization rate is sensitive to surfactant type based on this test. Used aqueous surfactants were solubilized and removed 72.77 to 89.90% of toluene, PCE(tetrachloroethylene) from the contaminated water during the test, respectively. T60 has higher and stable recovery ratio than SDS in surfactant type but, the micelle of the T60 is more weaker than that of SDS based on this study's results. And the solubilization rate in used water type was almost same.(deionized water, surface water).

  • PDF

A Study on the Heat Transfer and Film Growth During the III-V MOCVD Processes (III-V 족 MOCVD 공정의 열전달 및 필름 성장에 대한 연구)

  • Im, Ik-Tae;Shimogaki, Yukihiro
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1213-1218
    • /
    • 2004
  • Film growth rate of InP and GaAs using TMI, TMG, TBA and TBP is numerically predicted and compared to the experimental results. Obtained results show that the film growth rate is very sensitive to the thermal condition in the reactor. To obtain exact thermal boundary conditions at the reactor walls, we analyzed the gas flow and heat transfer in the reactor including outer tube as well as the inner reactor parts using a full three-dimensional model. The results indicate that the exact thermal boundary conditions are important to get precise film growth rate prediction.

  • PDF

Corrosion Monitoring for Protected Systems using Thin-Film Electrical Resistance (TFER) Sensor

  • Lee, Seong-Min;Li, SeonYeob;Jung, Sung-Won;Kim, YoungGeun;Song, HongSeok;Won, Deok-Soo
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.112-116
    • /
    • 2006
  • This study has been conducted to monitor the corrosion rate of cathodically protected structure and corrosion inhibited system using multi-line thin-film electrical resistance (TFER) sensor in various environments. The field test data of TFER sensor for the corrosion monitoring of cathodically protected underground pipeline in soil environments and of corrosion inhibited gas heaters were also presented. The sensor was found to be a powerful method to commit the sensitive pick-up of small corrosion rate which can be observed in the cathodically protected and corrosion inhibited systems.

Compressor Performance with Variation of Diffuser Vane Inlet Angle (디퓨저 베인각의 변화에 따른 압축기 성능 특성)

  • Bae, M. H.;Shin, Y. H.;Kim, K. H.;Kim, J. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.55-60
    • /
    • 1999
  • A centrifugal compressor was tested with three different diffusers with plate vanes. The vane inlet angle was varied from 15 to 30 dog. The higher static pressure rises are obtained with lower vane stagger angle. In the stable region the static pressure field in vaneless space is very sensitive to flow rate. The impeller has a stabilizing effect over the whole stable operating range. The diffuser has a stabilizing effect at high flow rate but is destabilizing at low flow rate.

  • PDF

비동조적 효용함수 가정시의 최적환경세율에 대한 연구: 계산적 일반균형(CGE) 시뮬레이션을 통한 접근

  • Kim, Sang-Gyeom
    • KDI Journal of Economic Policy
    • /
    • v.24 no.2
    • /
    • pp.53-82
    • /
    • 2002
  • Earlier papers, regarding this topic, have shown that the optimal environmental tax rate under the second best situation typically smaller than that under the first best world, the well known Pigouvian tax. This paper casts a doubt on the generality of this result, since the conclusion was derived from the models which employed rather strict assumptions on the utility function, which is homothetic and separable. This paper, with simple-static CGE model, shows that the result of earlier studies is sensitive to the assumption on the utility function. According to the simulation results, as previous studies pointed out, if the utility function is assumed to be homothetic, the optimal environmental tax rate is smaller than the Pigouvian tax. In contrast, if certain type of non-homotheticity is allowed, the optimal environmental tax rate could be greater than the Pigouvian tax. The results of this simulation also imply that the enlargement of environmental tax base could enhance the efficiency of overall tax system. Hence, there will be a less burden to share for the tax authority from the policy change.

  • PDF

Statistical analysis of the employment future for Korea

  • Lee, SangHyuk;Park, Sang-Gue;Lee, Chan Kyu;Lim, Yaeji
    • Communications for Statistical Applications and Methods
    • /
    • v.27 no.4
    • /
    • pp.459-468
    • /
    • 2020
  • We examine the rate of substitution of jobs by artificial intelligence using a score called the "weighted ability rate of substitution (WARS)." WARS is a indicator that represents each job's potential for substitution by automation and digitalization. Since the conventional WARS is sensitive to the particular responses from the employees, we consider a robust version of the indicator. In this paper, we propose the individualized WARS, which is a modification of the conventional WARS, and compute robust averages and confidence intervals for inference. In addition, we use the clustering method to statistically classify jobs according to the proposed individualized WARS. The proposed method is applied to Korean job data, and proposed WARS are computed for five future years. Also, we observe that 747 jobs are well-clustered according to the substitution levels.

Parametric Study on Performance of an Automobile Air Conditioner (차량용 에어컨의 성능에 미치는 인자에 관한 연구)

  • Park, Y.C.;Kwon, K.R.
    • Journal of Power System Engineering
    • /
    • v.6 no.4
    • /
    • pp.16-22
    • /
    • 2002
  • This study was conducted to find performance evaluation method for automobile air conditioner. Experimental facilities were constructed to simulate wide range of operating condition for the automobile air conditioner. Compressor speed was controled by variable speed electric motor and the power was measured through torque transducer and tachometer was used to measure compressor speed. Parametric studies were conducted in this study, to figure out effect of environment variables on the performance of the automobile air conditioner. The environmental variables are inlet air temperature, relative humidity and air flow rate for the evaporator and inlet air temperature and air flow rate for the condenser. Compressor speed is also changed. The results of this study shows that air flow rate of the evaporator is more sensitive to the performance of the automobile air conditioner than the other variables. However relative humidity of the inlet air of the evaporator strongly affects capacity rather that COP.

  • PDF

Relaxation of Photogenerated Carriers under He, $H_2, Co_2 and\; O_2$ on ZnO

  • 한종수;김혜정;진준
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.6
    • /
    • pp.676-680
    • /
    • 1998
  • The relaxation process of photogenerated carriers was investigated using conductivity measurement on ZnO under He, $H_2,\; CO_2\; and\; O_2$. The process was well explained with the rate constant of reaction or recombination of hole and electron, $k_h \;and\; k_e ( k_h > k_e)$, respectively. Generally, $k_h$ increased with the pressure of the gases. The slope of $k_h$ with respect to the pressure increased in the order of $H_2{\le}He, while $k_h$ of $O_2$ was sensitive to the history of the sample. The relaxation process on ZnO which was exposed to oxygen at 298 K and 573 K was observed during the illumination at 298 K and it was found that the rate constant of hole decreased with illumination time. From the result, it was suggested that the rate constant of photogenerated excess carriers was affected by the surface barrier of the semiconductor.

Pyrolysis Behavior of Pulverized Coal Particles at High Heating Rate (미분탄 입자의 고속가열 열분해거동 해석)

  • JANG, JIHOON;HAN, KARAM;YU, GEUN SIL;LIM, HYEON SOO;LEE, WOOK RYUN;PARK, HO YOUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.3
    • /
    • pp.260-268
    • /
    • 2019
  • The pyrolysis characteristics of pulverized coal particle was numerically analyzed with the drop tube furnace. Based on the simulated gas flow field in the drop tube furnace, the particle velocity, temperature and volatile evolution were calculated with the fourth order Runge-Kutta method. The effects of changes in reactor wall temperature and particle diameter on the pyrolysis behavior of coal particle were investigated. The particle heating rate was very sensitive to the reactor wall temperature and particle size, that is, the higher wall temperature and the smaller particle size resulted in the higher heating rate and the consequent quicker volatile evolution.