• 제목/요약/키워드: rate of temperature rise

검색결과 359건 처리시간 0.024초

미소 수용 Cyclohexange 중에서 분말 Lipase에 의한 분자내 에스테르화반응 (Intramolecular Esterification by Lipase Powder in Microaqueous Cycohexane)

  • 이민규;감삼규
    • 생명과학회지
    • /
    • 제5권4호
    • /
    • pp.155-161
    • /
    • 1995
  • The effects of substrate concentration, enzyme concentration, reaction temperature, and water content were investigated in intramolecular esterification. This study used cyclohexane as organic solvent, power lipase as enzyme, and benzyl alcohol and octanoic acid as substrate. The initial reaction rate was found to be proportional to enzyme concentration; followed Michaelis-Menten equation for octanoic acid; and was inhibited by benzyl alcohol . The observed initial reaction rate first increased, then decreased with increasing reaction temperature, giving rise to the maximum rate at 20$\circ$. The drop in the reaction rate at higher temperature was to partition equilibrium change of substrate between organic solvent and hydration layer of enzyme molecule in addition to the deactivation by enzyme denaturation. Water layer surrounding enzyme molecule seemed to activate in organic solvent and the realistic reaction was done in the water layer. In the enzymatic reaction in organic solvent, the initial reaction rate was influenced by partition quilibrium of substrate, so the optimum condition of substrate concentration, enzyme concentration, reaction temperature, and water content would give a good design tool.

  • PDF

액체로켓엔진의 2단 시동에 관한 연구 (A Study on the 2-Stage Startup of Liquid Rocket Engine)

  • 박순영;조원국
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.324-327
    • /
    • 2008
  • Two stage startup of high thrust liquid rocket engine can reduce the abrupt impulse to the vehicle and engine by changing oxidizer flow rate to the combustion chamber. Also it ensures stable ignition of combustion chamber against hard start and to prevent pump stall by the sudden supply of large mass flow rate. However high discharge pressure of oxidizer pump or temperature rise in gas generator may be a problem in applying the preliminary stage. To solve this problem, we analyzed the effect of the slope of oxidizer pump's head curve and the oxidizer mass flow rate to combustion chamber during preliminary stage using the rocket engine startup analysis code. A moderate slope(${\circleddash}{\sim}$-3) of head curve and 80% mass flow rate during preliminary stage can reduce the oxidizer pump discharge pressure by 15 to 20% comparing with the condition of ${\circleddash}$=-4.37 head curve and 70% mass flow rate. Also it can maintain the turbine inlet temperature rise within 50K from the nominal value.

  • PDF

Electrical Contact Characteristics of Ag-SnO2 Materials with Increased SnO2 Content

  • Chen, Pengyu;Liu, Wei;Wang, Yaping
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2348-2352
    • /
    • 2017
  • The electrical contact characteristics including temperature rise, contact resistance and arc erosion rate of the $Ag-SnO_2$ materials with increased $SnO_2$ content were investigated during the repeated make-and-break operations. The thickness of arcing melting layer reduces by half and the arc erosion rate decreases more than 70% under 10000 times operations at AC 10 A with the $SnO_2$ content increasing from 15 wt.% to 45 wt.%, on one hand, temperature rise and contact resistance increase obviously but could be reduced to the same order of conventional $Ag-SnO_2$ materials by increasing the contact force. The microstructure evolution and the effect of $SnO_2$ on the arc erosion, contact resistance were analyzed.

저온 폐열 활용을 위한 2중 효용 2단 흡수식 히트펌프 시뮬레이션 (Simulation of a Double Effect Double Stage Absorption Heat Pump for Usage of a Low Temperature Waste Heat)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권11호
    • /
    • pp.7736-7744
    • /
    • 2015
  • 막대한 산업용 에너지가 폐열로 버려지는 상황에서 폐열, 특히 저온 폐열의 효과적인 이용은 매우 중요하다. 본 연구에서는 $160^{\circ}C$의 고온 열원과 $17^{\circ}C$ 저온 하수열을 사용하여 $50^{\circ}C$의 온수를 $70^{\circ}C$로 승온시키며 성적계수는 1.6을 만족하는 2중 효용 2단 흡수식 히트펌프 사이클을 고안하였다. 제 1 재생기에서 증발한 냉매 증기는 제 1 응축기에서 응축하면서 제 2 재생기에서 다시 냉매를 발생시킨다. 이 냉매는 제 2 응축기를 거쳐 제 2 증발기에 모아진다. 이 냉매의 일부는 제 1 증발기로 이동하여 저온 열원을 받아들이고 제 1 흡수기를 거쳐 제 2 증발기에 공급된다. 제 2 증발기를 나온 냉매는 제 2 흡수기에서 용액에 흡수된다. 이 때 온수의 온도는 제 2 응축기와 제 2 흡수기에서 승온된다. 시행착오를 통하여 승온 $20^{\circ}C$, 성적계수 1.6을 만족시키는 유량과 열교환기의 UA 값을 도출하였다. 성적계수는 고온수의 온도가 증가할수록, 온수의 온도가 감소하고 유량이 증가할수록, 폐온수의 온도와 유량이 증가할수록, 용액 순환량이 감소할수록 증가한다. 반면 온수의 승온온도는 고온수의 온도가 증가할수록, 온수의 온도가 증가하고 유량이 감소할수록, 폐온수의 온도와 유량이 증가할수록, 용액 순환량이 증가할수록 증가한다. 또한, 열교환기의 UA 값이 증가할수록 성적계수 및 온수 승온 온도도 증가한다.

기후변화에 따른 소양호 수온 및 성층강도 변화 예측 (Projection of water temperature and stratification strength with climate change in Soyanggang Reservoir in South Korea)

  • 윤여정;박형석;정세웅
    • 한국물환경학회지
    • /
    • 제35권3호
    • /
    • pp.234-247
    • /
    • 2019
  • In a deep lake and reservoir, thermal stratification is of great importance for characteristics of hydrodynamic mixing of the waterbody, and thereby influencesvertical distribution of dissolved oxygen, substances, nutrients, and the phytoplankton community. The purpose of this study, was to project the effect of a future climate change scenario on water temperature, stratification strength, and thermal stability in the Soyanggang Reservoir in the Han River basin of South Korea, using a suite of mathematical models; SWAT, HEC-ResSim, and CE-QUAL-W2(W2). W2 was calibrated with historical data observed 2005-2015. Using climate data generated by HadGEM2-AO with the RCP 4.5 scenario, SWAT predicted daily reservoir inflow 2016-2070, and HEC-ResSim simulated changes in reservoir discharge and water level, based on inflow and reservoir operation rules. Then, W2 was applied, to predict long-term continuous changes of water temperature, in the reservoir. As a result, the upper layer (5 m below water surface) and lower layer (5 m above bottom) water temperatures, were projected to rise $0.0191^{\circ}C/year$(p<0.05) and $0.008^{\circ}C/year$(p<0.05), respectively, in response to projected atmospheric temperature rise rate of $0.0279^{\circ}C/year$(p<0.05). Additionally, with increase of future temperature, stratification strength of the reservoir is projected to be stronger, and the number of the days when temperature difference of the upper layer and the lower layer becomes greater than $5^{\circ}C$, also increase. Increase of water temperature on the surface of the reservoir, affected seasonal growth rate of the algae community. In particular, the growth rate of cyanobacteria increased in spring, and early summer.

초고층 아파트의 커튼월 결로 예측 방법에 관한 연구 (A Study on the Prediction Method of Condensation on the Curtain Wall of the High-rise Apartment Unit)

  • 임정희
    • 건설안전기술
    • /
    • 통권41호
    • /
    • pp.88-101
    • /
    • 2007
  • Recently, the condensation of walls often occurring in domestic high-rise apartment buildings is an important problem. The main purpose of this study is to develop the prediction method for the surface condensation on curtain wall in high-rise apartment buildings. Therefore, in this study, we first analyzed exterior climate factors through the analysis of the Seoul climate data and predicted the change of indoor temperature by using Apache program to find the cause of the condensation state and to prevent condensation. Also, according to this result, exterior climate factors and interior factors, which caused the condensation, was examined. The thermal performance of the curtain wall and the range of potential condensation were analyzed to focus on high-rise apartment buildings through computer simulation programs. The results are as $follows;^1$) The frame edge of curtain wall has a higher U-value than in the center by $30%^2$) Because of stack effect, the rooms on the higher floor have a lower external ventilation rate resulting to a higher relative humidity3) Installing a ventilation system($20m^3$/h. person) makes it possible to have a higher external ventilation rate, resulting to a lower relative humidity.

  • PDF

TiO2 광촉매 활성에서 소성온도의 영향 (Effects of Calcination Temperature on Ti02 Photocatalytic Activities)

  • 김승민;윤태관;홍대일
    • 한국환경과학회지
    • /
    • 제14권9호
    • /
    • pp.889-896
    • /
    • 2005
  • The nanosized $TiO_2$ photocatalysts were prepared by the hydrolysis of $TiCl_4$ and calcined at different temperatures. The resulting materials were characterized by TGA, DSC, XRD, and TEM testing techniques. XRD, TEM, and BET measurements indicated that the particle size of $TiO_2$ was increased with rise of calcination temperature and surface area was decreased with rise of it. The prepared $TiO_2$ photocatalysts were used for the photocatalytic degradation of congo red. The effects of calcination temperature, $TiO_2$ loading, the initial concentration of congo red, and usage frequencies were investigated and the rate constants were determined by regressing the experimental data. Calcination is an effective treatment to increase the photo activity of nanosized $TiO_2$ photocatalysts resulting from the improvement of crystallinity. The optimum calcination temperature of the catalyst for the efficient degradation of congo red was found to be $400^{\cric}C$. The rate constant was decreased with increase in the initial concentration of congo red and increased with increase in the $TiO_2$ loading. In the case of $TiO_2$ photocatalysts, the photocatalytic activity wasn't greatly affected by the usage frequencies.

EGR 성층화급기에 의한 DME HCCI 연소시의 압력 상승률 저감에 관한 연구 (A Study about the Effects of EGR Stratification on Reducing the Pressure RIse Rate of DME HCCI Combustion)

  • 임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.895-904
    • /
    • 2011
  • Stratified charge has been thought as one of the ways to avoid a sharp pressure rise on HCCI combustion. The purpose of this study is to evaluate the potential of stratified charge for reducing PRR on HCCI combustion. The pre-mixture with thermal, mixing and EGR stratifications is charged in Rapid Compression Machine. After that, the pre-mixture is compressed and in that process, in-cylinder gas pressure and temperature are analyzed. Additionally numerical calculation with multi-zones modeling is run to know the potential of stratified charge for reducing PRR.

디젤기관에서 바이오디젤 혼합유의 연소특성에 미치는 연료분사시기의 영향 (Effects of Fuel Injection Timing on Combustion Characteristics of Biodiesel Blend Oil in Diesel Engine)

  • 임재근;조상곤
    • 동력기계공학회지
    • /
    • 제16권3호
    • /
    • pp.10-15
    • /
    • 2012
  • Recently we have a growing interest in environmental pollution and alternative energy. Diesel engine is generally used to produce the power on the ground and the sea. However, the combustion characteristics are changed on account of the wear of fuel system and the altered ambient condition of the combustion chamber by the increment of the engine operation hour. Therefore combustion characteristics on fuel injection timing are experimentally investigated to find out the optimum fuel injection timing in the case of the aged diesel engine using biodiesel blend oil. Cylinder pressure, rate of pressure rise, rate of heat release and combustion gas temperature are risen by the advancing fuel injection timing, while the exhaust gas temperature and soot emission level are decreased by the advancing of fuel injection timing. The least specific fuel oil consumption is indicated at BTDC $26^{\circ}$ CA on the 75%load and at 1800rpm.

랙크식 물류창고 조기 화재감지를 위한 최적 화재감지기 설치방법에 관한 실험연구 (An Experimental Study on the Optimum Installation of Fire Detector for Early Stage Fire Detecting in Rack-Type Warehouses)

  • 최기옥;김동석;홍성호
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.38-45
    • /
    • 2017
  • This paper is an experimental study to find an optimal detection method for detecting fire early in a rack-type warehouse stored with goods. In this study, we constructed rack-type structure with the fourth floor of 13.5 m high and conducted fire experiments which were to measure flow of heat/smoke in rack-type structure and response time of fire detectors. The detectors used at experiments were fixed temperature type detectors, rate of rise detectors, photoelectric smoke detectors, air sampling smoke detectors and flame detectors. The used ignition sources are n-heptane fire for response of heat detection and cotton fire for response of smoke detection. The fixed temperature type detectors, rate of rise detectors and photoelectric detectors were installed to every rack level respectively. The results show that the rate of rise detector should be installed every 2 levels and photoelectric smoke detector should be installed every 4 levels for the early stage fire detection. Air sampling smoke detectors can detect fire early in response to control of sensitivity, but there is a problem in false alarm. The fixed temperature detector is not suitable for early stage fire detection in warehouse and flame detector not worked if flame is not visible, so it need to install combination with other detector.