• Title/Summary/Keyword: rate of resistance increase

Search Result 687, Processing Time 0.028 seconds

Variation of strength of soil matrix with artificially manipulating particle distribution of granular soil (인위적 입도조정에 따른 지반의 강도특성 변화)

  • Moon, Jun-Ho;Xin, Zhen-Hua;Kim, Gab-Boo;Moon, Sun-Mi;Kim, Young-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.56-62
    • /
    • 2018
  • In this study, an artificially formed Gap graded soil, designed to increase its shear strength, was analyzed to determine the strength parameters through direct shear tests. Uniform and fine grain size samples were compared to the Gap graded soil to investigate the increase in the shear strength. Plate loading tests were conducted using 13mm and 19mm aggregates to confirm the reproducibility of the strength enhanced samples for site application. This test confirmed that the particle size ratio and the internal friction angle are correlated to the shear strength, and the shear resistance angle significantly increased in the specific particle size ratio range. The calculation of the ultimate bearing capacity by the plate load test demonstrated that the grain size adjustment method greatly influences the strength increase rate. Therefore, the findings were verified and it was confirmed that a high shear strength is achievable despite the existence of a poor particle size distribution.

INFLUENCE OF COOLING RATE ON THERMAL EXPANSION BEHAVIOR AND FLEXURAL FAILURE OF PFM SYSTEMS (도재 냉각방법의 차이가 금속-도재간 열팽창 양상과 결합력에 미치는 영향)

  • Lim, Ae-Ran;Lim, Ho-Nam;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.165-191
    • /
    • 1990
  • Although a number of studies have been performed to assure that residual stress caused by a mismatch of alloy porcelain thermal expansion can contribute to clinical failure of a ceramometal restoration, the interactive influence of cooling rate on the magnitude of thermal expansion difference and on bond strength between them have not been extensively analyzed. The objective of this study was to determine the influence of cooling rate and the number of firing cycles on the expansion mismatch and the flexural failure resistance of metal porcelain strip. Tested alloys included one Pd-Ag alloy, one Ni-Cr-Be alloy with two kinds of porcelain, Vita and Ceramco. Metal specimens were cast into rods with a height of 13mm and a diameter of 5mm. Subsequently, the castings were subjected to scheduled firing cycles without porcelain. And the porcelain specimens after being fired were trimmed into a bar with a final dimension of $5{\times}5{\times}25mm$. Thermal expansions of the alloys and porcelains were measured by using a push rod or a differential dialometer respecitvely. Porcelain glass transition temperatures and expansion values were derived alloy-porcelain pairs were assessed by comparing expansion values of the components at a porcelain glass transition temperature. Calculations were made using combinations of a Ni-Cr alloy or Pd-Ag alloy with each of two porcelain products. Metal-porcelain strip specimens were subjected to four point loading in an Instron testing machine until crack occured at the metal-cramic interface at the time of sharp decrease of load on recorder. On the basis of this study, the following conclusions may be stated: 1. Regardless of the kinds of ceramometal combinations, both of calculated and experimental data revealed that the double fired specimens exhibited a significantly lower flexural strength. 2. By the rise of the amount of mismatch, bond strength were decreased. 3. Thermal expansion value of Pd-Ag alloys were higher than that of Ni-Cr alloys. 4. Expansion curves of metal were proportional to the increase of temperature and were not affected by the experimental conditions, however porcelains did not show the same magnitude of metal, and a shift of the glass transition temperature to higher temperatures was observed when cooled rapidly 5. Alloy-porcelain thermal compatibility appeared more dependent on the porcelain than the alloy.

  • PDF

INFLUENCE OF COOLING RATE ON THERMAL EXPANSION BEHAVIOR AND FLEXURAL FAILURE OF PFM SYSTEMS (도재 냉각방법의 차이가 금속-도재간 열팽창 양상과 결합력에 미치는 영향)

  • Lim, Ae-Ran;Lim, Ho-Nam;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.111-137
    • /
    • 1991
  • Although a number of studies have been performed to assure that residual stress caused by a mismatch of alloy porcelain thermal expansion can contribute to clinical failure of a ceramometal restoratoin, the interactive influence of cooling rate on the magnitude of thermal expansion difference and on bond strength between them have not been extensively analyzed. The objective of this study was to determine the influence of cooling rate and the number of firing cycles on the expansion mismatch and the flexural failure resistance of metal porcelain strip. Tested alloys included one Pd-Ag alloy, one Ni-Cr-Be alloy with two kinds of porcelain, Vita and Ceramco. Metal specimens were cast into rods with a height of 13mm and a diameter of 5mm. Subsequently, the castings were subjected to scheduled firing cycles without porcelain. And the porcelain specimens after being fired were trimmed into a bar with a final dimension of 5 x 5 x 25mm. Thermal expansions of the alloys and porcelains were measured by using a push rod or a differential dialometer respectively. Porcelain glass transition temperatures and expansion values were derived alloy- porcelain pairs were assessed by comparing expansion values of the components at a porcelain glass transition temperature. Calculations were made using combinations of a Ni-Cr alloy or Pd-Ag alloy with each of two porcelain products. Metal- porcelain strip specimens were subjected to four point loading in an Instron testing machine until crack occured at the metal-cramic interface at the time of sharp decrease of load on recorder. On the basis of this study, the following conclusions may be stated : 1. Regardless of the kinds of ceramometal combinations, both of calculated and experimental data revealed that the double fired specimens exhibited a significantly lower flexural strength. 2. By the rise of the amount of mismatch, bond strength were decreased. 3. Thermal expansion value of Pd-Ag alloys were higher than of Ni-Cr alloys. 4. Expansion curves of metal were proportional to the increase of temperature and were not affected by the experimental conditions, however porcelains did not show the same magnitude of metal, and a shift of the glass transition temperature to higher temperatures was observed when cooled rapidly. 5. Alloy- porcelain thermal compatibility appeared more dependent on the porcelain than the alloy.

  • PDF

Awareness and Attitude Relating to the Human Papilloma Virus and its Vaccines Among Pediatrics, Obstetrics and Gynecology Specialists in Turkey

  • Tolunay, Orkun;Celik, Umit;Karaman, Seyfettin Senih;Celik, Tamer;Resitoglu, Salim;Donmezer, Cigdem;Aydin, Fahri;Baspinar, Huseyin;Mert, Mustafa Kurthan;Samsa, Hasan;Arli, Sefa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10723-10728
    • /
    • 2015
  • Background: To determine the level of knowledge on human papillomavirus (HPV) infection and vaccination, and the attitude towards HPV vaccination in pediatricians, obstetricians and gynecologists (OBG). Materials and Methods: Participants were administered a 40-question survey, investigating the demographic properties, the knowledge on the HPV infection-vaccination and attitudes towards vaccination. Results: The study enrolled a total of 228 participants (131 pediatricians and 97 OBGs). At a rate of 99.6%, the participants agreed with the fact that the HPV infection was the most common sexually transmitted disease and 33.8% of the participants had the opinion that the HPV vaccination should be administered only in women. The lowest level of HPV vaccine recommendation was among the pediatrics specialists (59.4%, p=0.012). When asked whether they would have their daughters receive HPV vaccination, 79.5% of the participants answered favorably; this rate was 36.7% for the sons. At a rate of 59.5% of the participants thought that the HPV vaccine needed to be included in the national vaccine schedule. Most of the participants (91.6%) had the idea that reduction of the vaccine costs would increase the vaccination frequency. Conclusions: We observed that the consideration of the costs and the prejudices relating to the inefficacy of vaccination as well as the inadequate level of knowledge were involved in the physicians' resistance to HPV vaccination. We believe that the healthcare professionals should be informed adequately to overcome false beliefs, thereby ensuring success of the HPV vaccine upon inclusion in the national vaccine schedule in the future.

Nasal Carriage of Staphylococcus aureus from Healthy Children Attending Day Care Center (어린이집 소아에서의 황색포도알균의 비강 보균율에 관한 연구)

  • Kim, Young Min;Oh, Chi Eun;Kim, So Hee;Lee, Jina;Choi, Eun Hwa;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • Purpose : This study was performed to investigate the prevalence of Staphylococcus aureus (S. aureus) nasal carriage in Korean children attending day care centers. Methods : During September and October 2009, a survey for nasal carriage of S. aureus and methicillin-resistant S. aureus (MRSA) was conducted among children attending day care centers located in Seoul with questionnaire survey for evaluation of risk factors of acquisition of MRSA was obtained from their guardians. A culture of the anterior nares swabs using enrichment broth was executed for isolating S. aureus and oxacillin susceptibility was assessed by the disk diffusion method. Results : Out of the 428 children enrolled whose mean age was 55 months old, 163 (38.1%) were colonized with S. aureus. Of the 163 isolates, 40 (24.5%) were MRSA. The nasal carriage rate of S. aureus showed an increasing trend with increase of age. Based on the answer to the questionnaire, 9.2% and 3.6% of children had a recent history of hospitalization and surgery, respectively, and approximately 40% of children had a history of prescription of antibiotics within 1 year prior to enrollment. Of the 428 subjects, 40 (9.3%) were MRSA nasal carriers. Conclusion : S. aureus and MRSA carriage rate of children attending day care center in Korea was 38.1% and 9.3%, respectively. Continued surveillance for nasal carriage rate of S. aureus and MRSA (especially community-associated MRSA) is mandatory.

Current Analysis of Acintobacter baumannii Infection among Pediatric Patients in a Single-centered Study (단일기관 내 소아에서 Acinetobacter baumannii 의 감염현황의 분석)

  • Park, Hye Jin;Kim, Jung Min;Kim, Ki Hwan;Kim, Dong Soo
    • Pediatric Infection and Vaccine
    • /
    • v.18 no.1
    • /
    • pp.23-30
    • /
    • 2011
  • Purpose : Acinetobacter baumannii is an aerobic, gram negative coccobacillus. Due to its pathogenicity and ability to accumulate diverse mechanisms of resistance, the importance of this organism is increasing. Many reports have targeted adults, and studies of pediatric patients are limited. This study aims to investigate the current status of A. baumannii infection in children. Methods : From January 2001 to December 2008, 505 patients hospitalized with A. baumannii infection were enrolled. Admission records for underlying disease, duration of hospitalization, previous antibiotic use, location of admission, presence of ventilator care, and resistance to antibiotics were retrospectively reviewed and analyzed. Results : Hemato-oncological disease and neurological disease were 30.6% and 24.3% of all cases; therefore, these were the most common underlying diseases of patients with A. baumannii infection. Prevalence of A. baumannii infection was 78.1% in patients with previous antibiotic use, which was higher than that of the group not using previous antibiotic. And prevalence of multi-drug resistant and pan-drug resistant A. baumannii infection was 76.4% and 38.3% in patients with ICU care, 76.8% and 38.9% with ventilator care, and these were higher than the others. Rate of resistance to all groups of antibiotics showed a gradual increase to over 50% in 2008. Multi-drug resistant A. baumannii was 63.5% and pan-drug resistant A. baumannii was 48.2% of all cases. Conclusion : Prevalence of A. baumannii infection and resistance to antibacterial agents of A. baumannii is increasing. Adequate use of antibiotics and infection control should be emphasized in pediatric patients.

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

The Study on the Ferrokinetics and Acquired Immunity in Repeated Hookworm Infections (구충성빈혈(鉤蟲性貧血)에 관(關)한 연구(硏究))

  • Lee, Mun-Ho;Lee, Pyl-Ung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.1 no.2
    • /
    • pp.61-74
    • /
    • 1967
  • In order to confirm whether acquired immunity or resistance can be developed by the repeated hookworm infections, the 150 mature actively moving filariform ancylostoma duodenale larvae obtained from the severe hookworm anemia patients were orally given to 8 healthy volunteers in three divided doses, 50 in each, at 5 day interval. Also the hematological changes as well as several ferrokinetics using $^{59}Fe$ were done and were compared with 10 controls. The clinical symptoms and signs were checked every day for the first 3 weeks and then twice weekly until the end of the experiment. The appearance of the ova in the stool was examined by the formalin ether method and the ova was counted by the Stoll's method. The following laboratory tests were done: 1) Red blood cell count, venous blood hematocrit(micromethod), hemoglobin count (cyanomethemoglobin method) were checked every 5 to 7 day interval. 2) Plasma iron concentration (Barkan's modified method) was determined every 2 to 3 week interval. 3) Radioisotope studies: a) Ferrokinetics: Huff et al and Bothwell's method were applied. Erythropoietic Index (% of normal)=$\frac{Subject's\;turnover/100ml\;whole\;blood{\times}100}{Average\;normal\;turnover/100ml\;whole\;blood}$ of the gastrointestinal absorption of iron: Radioiron($^{59}Fe$) balance b) Quantitative measurement method was applied. c) Determination of the plasma erythropoietin activity: Fried's method was applied. Following were the results: 1) The serum iron level was lower. The red cell volume was decreased, but with relative increase of plasma volume. 2) The plasma iron disappearance time was accelerated and the plasma iron turnover rate was decreased. The red cell iron turnover rate was markedly increased, while all of the red cell iron concentration, circulating red cell iron. plasma iron pool were decreased. The daily iron pool turnover and red cell renewal rate were increased. 3) The erythropoietic index, erythropoietin activity and intestinal absorption of iron($^{59}Fe$) were markedly increased. 4) The infectivity was $9.8{\pm}1.31%$ which was lower than that observed in the single infection. 5) From these observations, it is concluded that the hookworm anemia is essentially iron deficieny in its origin and some immunity acquisition is possible with repeated infections.

  • PDF

Variation of Flow Rates in Heterogeneous Microchannel Systems (비균일계 마이크로채널에서의 유량 변화 특성)

  • Kim, Jin-Yong;Lee, Hyo-Song;Yu, Jae-Keun;Kim, Ki-Ho;Rhee, Young Woo
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.28-32
    • /
    • 2006
  • This study investigated the variation of flow rates in microchannels that consisted of polydimethyl siloxane (PDMS) and glass using various external voltages. Three different microchannel widths and two different depths. PDMS and negative photoresist (SU-8) were used to make the microchannels by the soft lithographic method. For each depth of microchannel ($50{\mu}m$ and $100{\mu}m$), three different widths ($100{\mu}m$, $200{\mu}m$ and $300{\mu}m$) were made. In each case, several different external voltages were applied (0.3 kV, 0.35 kV, 0.4 kV and 0.45 kV) to examine the flow rates. Our results indicated that flow rate increased with an increase of the external voltage at the same microchannel width. This was because the electrical field was increased as the external voltage increased. For the same external voltage, the flow rate increased as the microchannel's width increased. These results showed that the resistance in the microchannel decreased as the microchannel's width increased. Also, to investigate the effect of microchannel's depth and width, the cross-sectional area of the microchannel was increased to the double in area. As a result, the effect of the microchannel's depth was higher at a low external voltage, and the effect of the microchannel's width was higher at a high external voltage.

Effect to Material Strength Recovery of Stepped Patch Repair with Epoxy based Particle Reinforced GFRP Composites under Hygrothermal Environment (에폭시 기지 입자 강화 GFRP를 사용한 계단형 패치 보수법이 고온 고습 환경하에서 재료의 물성 회복에 미치는 영향)

  • Jung, Kyung-Seok;Park, Soo-Jeong;Kim, Yun-Hae
    • Composites Research
    • /
    • v.31 no.3
    • /
    • pp.88-93
    • /
    • 2018
  • In this study, damaged composite laminates were repaired by a stepped patch repair method using halloysite nanotube(HNT) and milled carbon(MC) reinforced composite materials with different amount of the particles. And the mechanical and structural effects of the particles on the interface between the damaged and repair surfaces were analyzed. At this time, after exposing them to a harsh environment of high temperature and humidity for a long time, the recovery rate of the material properties relative to the material forming the damaged plate was compared. As a result, at $70^{\circ}C$ high temperature distilled water, the hygroscopicity of the HNT/GFRP composites was significantly different from that of the MC/GFRP composites. Especially, 0.5, 1 wt. % HNT was added, the moisture absorption rate was the lowest and this was the factor that contributed to the mechanical strength increase. On the other hand, MC showed a high hygroscopic resistance only with a small amount, and the strength was different according to the action direction of the load, and the addition amount was also different.