• Title/Summary/Keyword: rate mode

Search Result 2,347, Processing Time 0.025 seconds

An Experimental Study on Improved Performance of Rotary Solid Dehumidifier (건식회전형 제습기의 성능향상에 관한 실험적 연구)

  • Lee Gi Young;Kim Hyo Kyung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.3
    • /
    • pp.285-294
    • /
    • 1987
  • Parametric study on the efficiency of Rotary Solid Dehumidifer are reported. Experi-ments have been performed by varying regeneration temperature, regeneration humidity, flow rate of regeneration air, angular velocity of dehumidifer rotor and regeneration angle. To improve the energy efficiency, MODE 2,3 where coding zone is constructed and MODE 4, 5 where recirculating zone is constructed, were studied through experimental method $\ldots$. These results show that economical operating ranges exist in regeneration temperature, flow rate of regeneration air, angular velocity of dehumidifier rotor and regeneration angle. MODE 2,3 where cooling zone is constructed between regeneration Bone and process zone, is far better than MODE 1 in view of energy effiency, and optimum cooling angle and flow rate of cooling air exist. But MODE 4 and MODE 5, where recirculating zone is constructed, are similar to MODE 1.

  • PDF

Effects of Failure Mode II on Crack Initiation and Crack propagation Steps Using Multilevel Fatigue Loading Test (다단계 피로하중 실험을 통한 균열 발생 및 전파단계에서 파괴모드 II 영향 분석)

  • Hong, Seok Pyo;Park, Sae Min;Kim, Ju Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.9
    • /
    • pp.853-860
    • /
    • 2017
  • To evaluate the effects of mode II on the crack initiation and propagation stages, the effects in the fatigue threshold region under a mixed-mode I+II loading state was experimentally investigated. In the case of mixed-mode I + II, during the crack initiation stage, as the loading application angle (${\theta}$) increased, cracks occurred in the lower load owing to the effects of mode II, while the crack propagation rate decreased. The effects of mode II were experimentally investigated in the crack propagation stage by means of multilevel loading direction variation. Following mixed-mode I+II ($0^{\circ}{\rightarrow}{\theta}{\rightarrow}60^{\circ}$), as the load application angle increased, the fatigue crack propagation rate decreased, as did the fatigue crack propagation rate, which occurred later. Following mixed-mode I + II in case of(${\theta}{\geq}75^{\circ}$), the fatigue crack propagation rate was found to increase, while the fatigue life decreased.

Analysis of Wear Proccess in Sliding Contact by X-ray Diffraction (X선회절에 의한 미끄럼접촉시 발생하는 마모과정의 해석(제1보 : 저경도강의 적용))

  • 이한영
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.19-24
    • /
    • 1999
  • Understanding of wear mode and prediction of wear rate of parts in sliding contact are very important in field of meterial design relating with wear resistant. This paper has been undertaken to analyze the possibility of elucidation of wear mode and prediction of wear rate for annealed steel in sliding contact using the X-ray diffraction. The sliding wear test with various velocities using pin-on-disc machine and the X-ray diffraction test on the worn surface have been carried out. The results have been shown that the magnitude of residual stress and half-value breadth on the worn surface have a good correlation with wear mode. The difference between before and after test of half-value breadth on worn surface has been shown to be exponential relation with wear rate in the same wear mode.

  • PDF

A Study on the pattern of tenant layout in the Urban Entertainment Center (도심 엔터테인먼트 쇼핑센터(UEC)의 테넌트 배치 형태에 관한 연구)

  • Lee, Hyunsoo;Oh, Jung-Ah
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.6
    • /
    • pp.233-242
    • /
    • 2012
  • The purpose of this study is to analyze the pattern of tenant layout for selected cases of five different Urban Entertainment Center(UEC) in Seoul. This research deals with the process of gaining tenant layout pattern of 40 different types. It is composed of three combination unit with tenants of the same or different consumption mode, which is divided into four different functions of retail, entertainment, dining, and service. Then, every tenant of research cases is classified as one of the fabric type, and the data is analyzed to gain its frequency rate with SPSS 14.0 program. The following is the overall explanation of the result for this research. The frequency of tenant layout pattern between the same consumption mode shows the high rate when compared to the other patterns with different consumption mode. For example, the frequency rate of tenant layout pattern which retail and dining consumption mode are placed side by side like RRR and DDD is high. Interestingly, the frequency rate of RRR type of tenant layout pattern that sells the similar products shows especially high level. It can provide the effective environment for shoppers to compare retail goods in many different stores as producing synergic effects when they are located near each other, so this strategy should be considered when planning tenants in UEC environment. Moreover, in case of dining tenants, when they are clustered together in the UEC environment it can play a role as an anchor tenant. Tenant layout pattern of dining-retail and dining-service consumption mode shows the high frequency rate than other layout pattern with other consumption mode. Besides, entertainment consumption tenants combined with dining or retail tenants show the high frequency rate when compared to the pattern combined with service consumption mode.

  • PDF

Mehods of Fracture Toughness and Evaluation for Interface Crack in Adhesively Bonded Joints (접착이음의 계면균열에 대한 파괴인성 및 평가방법)

  • 정남용
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.220-226
    • /
    • 1998
  • In this pater, a method of strength evaluation applying fracture mechanics in adhesively bonded joints of A1/A1 materials was investigated. Various adhesively bonded joints of double-cantilever beam with a interfacial crack in its adhesive layer were prepared for the fracture toughness test of comprehensive mixed mode conditions from nearly pure mode I to mode II. The experiment of fracture toughness was carried out under various mixed mode conditions with an interfacial crack and critical energy release rate, Gc by the experimental measurements of compliances was determined. From the results, fracture toughness on mixed mode with an interfacial crack is well characterized by strain energy release rate and a method of strength evaluation by the fracture toughness in adhesively bonded joints of A1/A1 materials was discussed.

  • PDF

Fast Prediction Mode Decision in HEVC Using a Pseudo Rate-Distortion Based on Separated Encoding Structure

  • Seok, Jinwuk;Kim, Younhee;Ki, Myungseok;Kim, Hui Yong;Choi, Jin Soo
    • ETRI Journal
    • /
    • v.38 no.5
    • /
    • pp.807-817
    • /
    • 2016
  • A novel fast algorithm is suggested for a coding unit (CU) mode decision using pseudo rate-distortion based on a separated encoding structure in High Efficiency Video Coding (HEVC). A conventional HEVC encoder requires a large computational time for a CU mode prediction because prediction and transformation procedures are applied to obtain a rate-distortion cost. Hence, for the practical application of HEVC encoding, it is necessary to significantly reduce the computational time of CU mode prediction. As described in this paper, under the proposed separated encoder structure, it is possible to decide the CU prediction mode without a full processing of the prediction and transformation to obtain a rate-distortion cost based on a suitable condition. Furthermore, to construct a suitable condition to improve the encoding speed, we employ a pseudo rate-distortion estimation based on a Hadamard transformation and a simple quantization. The experimental results show that the proposed method achieves a 38.68% reduction in the total encoding time with a similar coding performance to that of the HEVC reference model.

A Dual-Mode 2.4-GHz CMOS Transceiver for High-Rate Bluetooth Systems

  • Hyun, Seok-Bong;Tak, Geum-Young;Kim, Sun-Hee;Kim, Byung-Jo;Ko, Jin-Ho;Park, Seong-Su
    • ETRI Journal
    • /
    • v.26 no.3
    • /
    • pp.229-240
    • /
    • 2004
  • This paper reports on our development of a dual-mode transceiver for a CMOS high-rate Bluetooth system-onchip solution. The transceiver includes most of the radio building blocks such as an active complex filter, a Gaussian frequency shift keying (GFSK) demodulator, a variable gain amplifier (VGA), a dc offset cancellation circuit, a quadrature local oscillator (LO) generator, and an RF front-end. It is designed for both the normal-rate Bluetooth with an instantaneous bit rate of 1 Mb/s and the high-rate Bluetooth of up to 12 Mb/s. The receiver employs a dualconversion combined with a baseband dual-path architecture for resolving many problems such as flicker noise, dc offset, and power consumption of the dual-mode system. The transceiver requires none of the external image-rejection and intermediate frequency (IF) channel filters by using an LO of 1.6 GHz and the fifth order onchip filters. The chip is fabricated on a $6.5-mm^{2}$ die using a standard $0.25-{\mu}m$ CMOS technology. Experimental results show an in-band image-rejection ratio of 40 dB, an IIP3 of -5 dBm, and a sensitivity of -77 dBm for the Bluetooth mode when the losses from the external components are compensated. It consumes 42 mA in receive ${\pi}/4-diffrential$ quadrature phase-shift keying $({\pi}/4-DQPSK)$ mode of 8 Mb/s, 35 mA in receive GFSK mode of 1 Mb/s, and 32 mA in transmit mode from a 2.5-V supply. These results indicate that the architecture and circuits are adaptable to the implementation of a low-cost, multi-mode, high-speed wireless personal area network.

  • PDF

Phase Resonance in Centrifugal Fluid Machinery -A Comparison between Pump Mode and Turbine Mode Operations and a Discussion of Mechanisms of Flow Rate Fluctuation through a Stator-

  • Yonezawa, Koichi;Toyahara, Shingo;Motoki, Shingo;Tanaka, Hiroshi;Doerfler, Peter;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.2
    • /
    • pp.42-53
    • /
    • 2014
  • Phase resonance in Francis type hydraulic turbine is studied. The phase resonance is a phenomenon that the pressure fluctuation in the penstock of hydraulic turbine installation can become very large when the pressure waves from each guide vane caused by the interaction with the runner vane reach the penstock with the same phase. Experimental and numerical studies have been carried out using a centrifugal fan. In the present study, comparisons between the pump mode and the turbine mode operations are made. The experimental and numerical results show that the rotational direction of the rotor does not affect characteristics of the pressure fluctuation but the propagation direction of the rotorstator interaction mode plays an important role. Flow rate fluctuations through the stator are examined numerically. It has been found that the blade passing flow rate fluctuation component can be evaluated by the difference of the fluctuating pressure at the inlet and the outlet of the stator. The amplitude of the blade passage component of the pressure fluctuation is greater at the stator inlet than the one at the stator outlet. The rotor-stator interaction mode component is almost identical at the inlet and the outlet of the stator. It was demonstrated that the pressure fluctuation in the volute and connecting pipe normalized by the flow rate fluctuation becomes the same for pump and turbine mode operations, and depends on the rotational direction on the interaction mode.

The Mixed Mode fatigue Crack Propagation Behavior with the Variation of Stress Ratio (응력비 변화에 따른 혼합모드 피로균열 전파거동)

  • Song, Sam-Hong;Choi, Ji-Hoon;Lee, Jeong-Moo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2287-2296
    • /
    • 2002
  • Most cracks in the structure occur under mixed mode loading and those fatigue crack propagation behavior heavily depends on the stress ratio. So, it is necessary to study the fatigue behavior under mixed mode loading as the stress ratio changes. In this paper, the fatigue crack propagation behavior was respectively investigated at stress ratio 0.1, 0.3, 0.5, 0.7 and we changed the loading application angle into 0$^{\circ}$, 30$^{\circ}$, 60$^{\circ}$ to apply various loading mode. The mode I and II stress intensity factor of CTS specimen used in this study was calculated by the displacement extrapolation method using FEM (ABAQUS). Using both the experiment and FEM analysis, we have concluded the relationship between crack propagation rate and stress intensity factor range at each loading mode due to the variation of stress ratio. Also, when the crack propagated under given stress ratio and loading mode condition, we have concluded the dominant factors of the crack propagation rate at each case.

A Study Comparing the Effects of Burst Mode and High Rate Mode Transcutaneous Electrical Nerve Stimulation on Experimental Pain Threshold and Skin Temperature (Burst형과 고빈도형 경피신경전기자극치료가 실험적 동통역치와 체온에 미치는 영향 비교)

  • Kim, Suhn-Yeop;Choi, Houng-Sik;Kwon, Oh-Yun
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.2
    • /
    • pp.465-479
    • /
    • 1995
  • We randomly assigned 61 healthy subjects(male 14, female 47) to compare the experimental pain threshold and skin temperature between high mode TENS and burst mode TENS. In this study, 61 subjects were divided into three groups ; high mode TENS(n=20), burst mode TENS (n=20), and control group(n=21). Experimental pain thresholds and skin temperatures were measured before, immediately after cessation of stimulation, and at 30 minutes post stimulation. Stimulation was applied to the dorsal surface of the forearm(L14, LI10). Pain thresholds were measured by chronaxie meter. Skin temperature were measured by electrical digital thermometer. The results are as follows ; 1. There were no statistical difference in the pain threshold and skin temperature at before TENS stimulation among the three groups(p>0.05). 2. The pain threshold and skin temperature in burst mode TENS group was significantly higher and longer effect than that in high mode TENS group and control group(p<0.01). 3. The pain threshold in burst mode TENS group decreased to prestimulation levels by 30 minutes poststimulation. 4. The skin temperature in burst mode TENS group decreased to prestimulation levels by 20 minutes poststimulation. 5. The skin temperature was significantly difference among three group at immediately after, and at 30 minutes poststimulation and the skin temperature in burst mode TENS group was significantely higher than that in two groups(p<0.001). 6. The increasing rate of pain threshold in high mode TENS group after immediately cassation of stimulation was 24.3%(p<0.001). 7. The increasing rate of pain threshold in burst mode TENS group after immediately cessation of stimulation was 93.5% (p<0.001).

  • PDF