• 제목/요약/키워드: rapid migration test

검색결과 19건 처리시간 0.028초

Effect of measurement method and cracking on chloride transport in concrete

  • Zhang, Shiping;Dong, Xiang;Jiang, Jinyang
    • Computers and Concrete
    • /
    • 제11권4호
    • /
    • pp.305-316
    • /
    • 2013
  • This paper aims to study the effect of measurement methods and cracking on chloride transport of concrete materials. Three kinds of measurement methods were carried out, including immersion test, rapid migration test and steady-state migration test. All of these measurements of chloride transport show that chloride ion diffusion coefficient decreased with the reduction of water to cement ratio. Results of the immersion test were less than that of rapid migration test and steady-state migration test. For the specimen of lower water to cement ratio, the external electrical field has little effect on chloride binding relatively. Compared with the results obtained by these different measurement methods, the lower water to cement ratio may cause smaller differences among these different methods. The external voltage can reduce chloride binding of concrete, and the higher electrical field made a strong impact on the chloride binding. Considering the effect of high voltage on the specimen, results indicate that results based on the steady-state migration test should be more reasonable. For cracked concrete, cracking can accelerate the chloride ion diffusion.

A simplified method to determine the chloride migration coefficient of concrete by the electric current in steady state

  • Lin, K.T.;Yang, C.C.
    • Computers and Concrete
    • /
    • 제13권1호
    • /
    • pp.117-133
    • /
    • 2014
  • This study presents a rapid method for determining the steady state migration coefficient of concrete by measuring the electric current. This study determines the steady state chloride migration coefficient using the accelerated chloride migration test (ACMT). There are two stages to obtain the chloride migration coefficient. The first stage, the steady-state condition was obtained from the initial electric current at the beginning of ACMT. The second stage, the average electrical current in the steady state condition was used to determine the steady state chloride migration coefficient. The chloride migration coefficient can be determined from the average steady state current to avoid sampling and analyzing chlorides during the ACMT.

전기 영동법에 기초한 콘크리트의 급속 염소이온 확산 특성 평가 (Rapid Chloride Penetration Test for Concrete Based on the Electrochemical Method)

  • 오상균;박동천
    • 한국항해항만학회지
    • /
    • 제34권10호
    • /
    • pp.787-792
    • /
    • 2010
  • 콘크리트는 물시멘트비에 상응하는 공극을 가지게 되며, 공극을 통한 염소이온의 확산을 평가하기 위하여 해안가 폭로 및 해수 침지실험이 널리 사용된다. 이상의 실험은 경우에 따라서 다년간의 시간을 요하는 경우도 있어, 최근에는 전기 영동법에 기초한 급속 염소이온 확산시험을 실시하는 경우가 많으나, 그 값이 폭로 및 침지 시험에서 얻은 값과 상이한 경우가 많아 데이터의 실용성을 높이기 위하여 그 원인 규명이 절실한 실정이다. 본 연구에서는 평가 방법으로써 Nernst-Einstein의 식을 통한 염화물 이온 이동계수의 산정방법을 사용하였으며, NT BUILD 492법 및 해수 침지실험을 통한 확산 특성과 비교하여 값의 차이에 대하여 고찰하였다. 그 결과 실험인자의 변화가 염소이온 확산에 미치는 영향은 미비한 것으로 평가되어져 실험조건에서 발생하는 영향은 거의 없는 것으로 규명되었으며, NT BUILD 492법과도 거의 동일한 값이 구해졌다. 침지실험 결과와의 상이는 염소이온 확산에서 경계조건의 차이 및 염소이온의 시멘트 수화물과의 고정화에 의한 것으로 판단되어진다.

마감재가 시공된 콘크리트에 있어서 염화물 확산계수 산정 방법 (A Calculating Method of Chloride Ion Migration Coefficient in Concrete Coated Finish Materials)

  • 조한규;안재철;강병희;오상균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.31-32
    • /
    • 2011
  • The purpose of this study is to investigate the amount of chloride penetration into concrete finishing materials. Chloride ion migration test was used rapid infiltration method proposed by 'NT-Build 492'. The kind of coated finishing material is 'None-finished(N)', 'Cement Mortal(M)', 'Water based paint(P)', 'Bone-Tile(B)', 'Repair Mortal(R1)' in this paper.

  • PDF

Chloride Diffusion in Mortars - Effect of the Use of Limestone Sand Part I: Migration Test

  • Akrout, Khaoula;Ltifi, Mounir;Ouezdou, Mongi Ben
    • International Journal of Concrete Structures and Materials
    • /
    • 제4권2호
    • /
    • pp.105-108
    • /
    • 2010
  • In order to determine the effect of the use of limestone sand on chloride ion ingress in mortar, specimens were cast with two different sands: siliceous sand (used as reference) and limestone crushed sand (used for this study). To compare and assess the resistance of this mortar to chloride penetration, two different diffusions tests were employed: slow migration and rapid migration (AASHTO test). In this study, calculation of the effective diffusion coefficient is proposed using a model based on Nernst. Planck equation. The diffusion coefficients from each sample were compared. The results for all tests show that the diffusion coefficients for siliceous sand mortar are larger than those obtained with limestone sand. It appears also that the diffusion coefficient varies as a function of the W/C ratio.

Automatic categorization of chloride migration into concrete modified with CFBC ash

  • Marks, Maria;Jozwiak-Niedzwiedzka, Daria;Glinicki, Michal A.
    • Computers and Concrete
    • /
    • 제9권5호
    • /
    • pp.375-387
    • /
    • 2012
  • The objective of this investigation was to develop rules for automatic categorization of concrete quality using selected artificial intelligence methods based on machine learning. The range of tested materials included concrete containing a new waste material - solid residue from coal combustion in fluidized bed boilers (CFBC fly ash) used as additive. The rapid chloride permeability test - Nordtest Method BUILD 492 method was used for determining chloride ions penetration in concrete. Performed experimental tests on obtained chloride migration provided data for learning and testing of rules discovered by machine learning techniques. It has been found that machine learning is a tool which can be applied to determine concrete durability. The rules generated by computer programs AQ21 and WEKA using J48 algorithm provided means for adequate categorization of plain concrete and concrete modified with CFBC fly ash as materials of good and acceptable resistance to chloride penetration.

콘크리트의 촉진염소이온 확산 시험법에 관한 연구 (A Study for the Accelerated Chloride Diffusion Test of Concrete)

  • 이용은;김진철;이찬영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.427-432
    • /
    • 1999
  • An electrci method for the rapid determination of chloride diffusion coefficient in concrete is proposed considering the electrical migration term in the Nernst-Plank equation. The experimental set-up for this method is basically that for PD index by Dhir, excluding some change in the experimental parameter values in consideration of reliability, simplicity and rapidity of the accelerated test method. Experimental results show that 30mm of specimen thickness, 10 volt of supplied potential, and 5M of chloride ion concentration are optimal

  • PDF

DNA damage와 Apoptosis를 정량화하는 단세포전기영동법 (Single Cell Gel Electrophoresis (comet assay) to Detect DNA Damage and Apoptosis in Cell Level)

  • 류재천;김현주;서영록;김경란
    • 한국환경성돌연변이발암원학회지
    • /
    • 제17권2호
    • /
    • pp.71-77
    • /
    • 1997
  • The single cell gel electrophoressis(SCGE) assay, also known as the comet assay, is a rapid, simple, visual and sensitive technique for measuring and analysing DNA breakage in mammalian cells. The SCGE or comet assay is a promising test for the detection of DNA damage and repair in individnal cells. It has widespread potential applications in DNA damage and repair studies, genotoxicity testing and biomonitoring. In this microgel electrophoresis technique, cells are embedded in agarose gel on microscope slides, iysed and electrophoresed under alkaline conditions. Cells with increased DNA damage display increased migration of DNA from the nucleus towards the anode. The length of DNA migration indicates the amount of DNA breakage in the cell. The comet assay is also capable of identifying apoptotic cells which contain highly fragmented DNA. Here we review the development of the SCGE assay, existing protocols for the detection and analysis of comets, the relevant underlying principles determining the behaviour of DNA and the potential applications of the technique.

  • PDF

면역크로마토그라피 기법을 이용한 Salmonella 속균 신속 검출킷트 개발 (Development of the rapid detection kit for Salmonella spp. using immunochromatographic assay)

  • 정병열;정석찬
    • 대한수의학회지
    • /
    • 제45권2호
    • /
    • pp.191-197
    • /
    • 2005
  • An immunochromatographic (IC) strip for the rapid detection of Salmonella spp. in the enriched sample was developed. Affinity purified Salmonella polyclonal antibody was conjugated with 40 nm colloidal gold particles which were prepared by citrate method in our laboratory. The antigen-antibody-gold complex was captured by Salmonella antibody attached to test line of nitrocellulose membrane during the capillary migration of sample. Specificity of the IC strip was calculated to be 100% (12/12) and sensitivity was 97.6% (41/42) in the test with pure cultured bacteria. Salmonella was artificially inoculated into raw pork macerated with enrichment broth. And then it was 10-fold diluted from $5.2{\times}10^{8}CFU/ml$ to 5.2 CFU/ml. The IC strip could detect $5.2{\times}10^{6}CFU/ml$ before enrichment. However, the lowest limit of detection was 5.2 CFU/ml after overnight incubation. The results indicated that the IC assay was a rapid, economical and simple method with high specificity and sensitivity for the detection of Salmonella spp. without using any equipment.

가속수명시험을 이용한 은도통홀 인쇄회로기판의 신뢰성연구 (Accelerated Life Test and Data Analysis of the Silver Through Hole Printed Wiring Board)

  • 전영호;권이장
    • 품질경영학회지
    • /
    • 제25권2호
    • /
    • pp.15-27
    • /
    • 1997
  • This paper describes a highly accelerated life test (HALT, USPCBT) method for rapid qualification testing of STH PWB(Silver Through Hole Printed Wiring Boards). This method was carried out to be an alternative to the present time-consuming standard 1344 hours life testing(THB). The accelerated life test conditions were $121^{\circ}C$/95%R.H. at 50V bias and without bias. Their results are compared with those observed in the standard 1344 hours life test at $40^{\circ}C$/95%R.H. at 50V bias and without bias. The studies were focused on the samples time-to-failure as well as the associated conduction and failure mechanisms. The abrupt drop of insulation resistance is due to the absorption of water vapour. And the continuous drop of insulation resistance is due to the Ag migration. The ratios of time-to-failure of HALT(USPCBT) to THB were 25 and 11 at 50V bias and without bias respectively.

  • PDF