• Title/Summary/Keyword: ramp system

Search Result 243, Processing Time 0.026 seconds

Quality Monitoring Comparison of Global Positioning System and BeiDou System Received from Global Navigation Satellite System Receiver

  • Son, Eunseong;Im, Sung-Hyuck
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.4
    • /
    • pp.285-294
    • /
    • 2018
  • In this study, we implemented the data quality monitoring algorithm which is the previous step for real-time Global Navigation Satellite System (GNSS) correction generation and compared Global Positioning System (GPS) and BeiDou System (BDS). Signal Quality Monitoring (SQM), Data QM, and Measurement QM (MQM) that are well known in Ground Based Augmentation System (GBAS) were used for quality monitoring. SQM and Carrier Acceleration Ramp Step Test (CARST) of MQM result were divided by satellite elevation angle and analyzed. The data which are judged as abnormal are removed and presented as Root Mean Square (RMS), standard deviation, average, maximum, and minimum value.

Driving System Design for Poly-Si TFT LCD of EWS (EWS급 Poly-Si TFT-LCD의 구동 시스템 설계)

  • Heon, Kwon-Byong;Park, Jong-Kwan;Cho, Kyu-Min;Choi, Myoung-Ryeul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3120-3122
    • /
    • 1999
  • In this paper we have designed the signal processing system for driving the Poly-Si TFT LCD of EWS. The signal processing system consist of timing controller, ramp signal generator and video signal processing system. Timing controller includes the top-down inversion. left right inversion, left-right shifting and control signal generator according to multi-source signal. The video signal processing system generates sawtooth-shaped waveform by using PROM and DAC for multi-gray scales and implements gamma correction function for compensating the TFT-LCD nonlinear charcteristic of the TFT-LCD. Finally we have discussed the experiment results and its application according to the designed TFT-LCD driving system.

  • PDF

Gird-interactive Current Controlled Voltage Source Inverter System with UPS (UPS를 고려한 계통연계 전류제어형 전압원 인버터)

  • Ko, Sung-Hun;Lim, Sung-Hun;Lee, Su-Won;Lee, Seong-Ryong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1064-1070
    • /
    • 2007
  • This paper presents a grid-interactive current controlled voltage source inverter (CCVSI) with uniterruptible power supply (UPS), which uses an inner current control loop (polarized ramp time (PRT)) and outer feedback control loops to improve grid power quality and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, a single stage CCVSI is used. The operation of this system could be divided into the power quality control (PQC) state mode and the UPS state mode. In PQC mode, the system operated to compensate the reactive power demand by nonlinear load or variation in load. In UPS mode. the system is controlled to provide a sinusoidal voltage at the rated value for the load when the gird fail. To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results for 1KVA load capacity is presented.

Improvement of Transient Step Response Using Feedforward Compensator in Nonminimum Phase Systems

  • Kwon, Byung-Moon;Ryu, Hee-Seob;Kwon, Oh-Kyu
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.3
    • /
    • pp.152-158
    • /
    • 2001
  • This paper proposes a simple feedforward compensator in order to decrease the amount of undershoots and overshoots on the step response in nonminimum phase systems. The compensator makes the step type input be a ramp input with saturation for 0$\leq$t<${\alpha}$. It is shown in this paper that the compensated system has small amount of undershoot and overshoot at the price of rise time compared to the system without compensator. Also, provided the system is properly stable, the influence of the design parameter ${\alpha}$ on the step response of the nonminimum phase system is investigated in the case of Type A, and Type B undershoot, which gives a guideline for the compensator design.

  • PDF

A study on the robustness and optimality of a LQ computer control for a manipulator with flexible joints (유연관절을 갖고 있는 로보트를 위한 LQ 컴퓨터 제어의 강인성과 최적성에 관한 연구)

  • 김진화;김진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.149-154
    • /
    • 1990
  • In this paper, simulation results of a robust digital tracking controller on a robotic manipulator are presented. The objective is to follow a ramp reference input with zero steady state error in the presence of a disturbance and system parameter variations. Some of the difficulties are caused by the Coulomb frictions, the disturbance due to the gravitational pull, the spring effect of a link between the drive motor and the manipulator arm. Another difficulty is that, because of the non-differentiable Coulomb friction, the digital control system cannot be represented as a discrete system. It is thus necessary to design the controller based on a discrete-continuous hybrid model. The controller is based on feeding back the state variables and augmenting the system by addition discrete integrators. The feedback gain parameters are obtained by applying the quadratic optimal control theory and then choosing the new weighting matrices to eliminate the limit cycle by using the describing function method for hybrid system.

  • PDF

Diagnostic/prognostic health monitoring system and evaluation of a composite bridge

  • Mosallam, A.;Miraj, R.;Abdi, F.
    • Smart Structures and Systems
    • /
    • v.5 no.4
    • /
    • pp.397-413
    • /
    • 2009
  • Composite bridges offer many advantages compared to current steel and aluminum bridges. This paper presents the results of a comprehensive on-going research program to develop innovative Diagnostic Prognostic System (DPS) and a structural evaluation of Composite Army Bridge (CAB) system. The DPS is founded on three technologies: optical fiber sensing, remote data transmission, and virtual testing. In developing this system, both laboratory and virtual test were used in different damage scenarios. Health monitoring with DPS entailed comparing live strain data to archived strained data in various bridge locations. For field repairs, a family of composite chords was subjected to simple ramp loads in search of ultimate strength. As such, composite bridge specimens showcased their strengths, heralded the viability of virtual testing, highlighted the efficacy of field repair, and confirmed the merits of health monitoring.

Designing Test Methods for IT-Enabled Energy Storage System to Evaluate Energy Dynamics

  • Kim, Young Gon;Kim, Dong Hoon;Lee, Eun-Kyu
    • Journal of Information Processing Systems
    • /
    • v.13 no.6
    • /
    • pp.1487-1495
    • /
    • 2017
  • With increasing interests in renewables, more consumers are installing an energy storage system (ESS) in their backyards, and thus, the ESS will play a critical role in the emerging smart grid. Due to mechanical properties, however its operational dynamics must be well understood before connecting the ESS to the smart grid (and eventually to an IT system). To this end, we investigate charging and discharging processes in detail. This paper, then, proposes methods for four type tests (state of charge test, conversion efficiency test, response time test, and ramp rate test) that can assess the dynamics of the ESS. The proposed methods can capture accurate delay values of mechanical processes in the ESS, and it is expected for those values to help design real-time communication systems in the smart grid involving the ESS.

Lessons Learned from Energy Storage System Demonstrations for Primary Frequency Control

  • Yu, Kwang-myung;Choi, In-kyu;Woo, Joo-hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.107-114
    • /
    • 2018
  • In recent years, ESS (Energy Storage System) has been widely used in various parts of a power system. Especially, due to its fast response time and high ramp rate, ESS is known to play an important role in regulating grid frequency and providing rotational inertia. As the number of installed and commercially operating ESSs increases, the reliability becomes an important issue. This paper introduces control schemes and presents its test method for grid-connected ESS for primary frequency regulation. The test method allows to verify the control operation in the individual operation mode and state. A validation of the method through actual ESS test in a electrical substation is presented in the case study section.

A Study on the Operating Characteristics of Molded Case Circuit Breakers according to Temperature Rise (온도상승에 따른 배선용 차단기의 동작특성에 관한 연구)

  • Jung, Da-Woon;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.8-13
    • /
    • 2015
  • Molded Case Circuit Breakers (MCCBs) are typically used to provide over current protection for electrical safety caused by short circuit faults and overloads in indoor low voltage power systems. The MCCB automatically connects and disconnects loads from the electrical source when the current reaches a value and duration that will cause an excessive. However, the MCCB sometimes is not interrupted due to a malfunction, nuisance tripping, or in a fire. Ensuring electrical safety is very important in a indoor low voltage power system. This paper presents the operating characteristics of MCCBs according to a temperature rise from room temperature to 160 degrees Celsius delivered by a radiant panel heater. The ABS 54c(rated current: 30A) of the hydraulic magnetic trip type was used in the experiments. The signals of temperature, voltage, and current were measured using the high accuracy Signal Conditioning Extensions for Instrumentation (SCXI) measurement system with the LabVIEW program manufactured by National Instruments. The operating characteristics were measured as functions of current amplitude and ramp-up rate. The MCCB tripping time decreased as a result of increasing current amplitude and ramp-up rate under a temperature rise condition, because the temperature and level of the current are directly proportional to the tripping time. Additionally, an instantaneous operation was observed after 8 times of the rated current, and the MCCB began to melt a surface temperature of around 300 degrees Celsius of. The experimental results coincided well with the operating curve.

A design on robust multivariable model following servo system (강인한 다변수 모델 추종형 서보시스템의 구성에 관한 연구)

  • Hwang, C.S.;Choi, Y.K.;Lee, Y.W.;Choi, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.370-373
    • /
    • 1991
  • This paper considers the linear multivariable model following servo system synthesis method in which linear optimal regulator problem is used to design controllers that make the response of the plant should be kept close to a specified ideal response of the model. The characteristics of this system is that the constructed system is robust in the presence of the constant disturbances or the parameter perturbations of the plant. Especially, the steady state offset is excluded for the ramp response of the model by direct feedforward compensator from the reference input.

  • PDF