• Title/Summary/Keyword: radius fracture

Search Result 192, Processing Time 0.027 seconds

Biaxial Fracture Behavior of Alumina Ceramics ; Thickness Effect on Ball-on-3-ball Test (시편 두께에 따른 알루미나 세라믹스의 이축 파괴 거동)

  • 이홍림;박성은;이중현
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.7
    • /
    • pp.711-717
    • /
    • 1999
  • Biaxial fracture behavior of alumina specimens with the diameter of 20mm and four kinds of thickness of 1.9, 2.3, 2.6 and 2.8mm was studied by the ball-on-3-ball test and the fracture results were analyzed by he analysis of variance (ANOCA), The strength measured with the down speed prescribed in ASTM showed that the measured strength was not dependent on the thickness of the specimens. Equivalent radius and crack-braching number were observed to increase lineraly with the thickness of the specimens. The jog direction was observed to study the effect of grinding direction on surface flaws. It is though that the surface finishing with #600 grit diamond wheel did not affect the surface flaws of the specimens.

  • PDF

Energy and strength in brittle materials

  • Speranzini, Emanuela
    • Smart Structures and Systems
    • /
    • v.23 no.4
    • /
    • pp.373-385
    • /
    • 2019
  • A study concerning the strength of brittle materials is presented in this paper. The failure behavior was investigated examining the plane of the crack after the failure and comparing the results obtained with those deriving from the fracture mechanics theory. Although the proposed methods are valid in general for brittle materials, the experiment was performed on glass because the results are more significant for this. Glass elements of various sizes and different edge finishes were subjected to bending tests until collapsing. The bending results were studied in terms of failure load and energy dissipation, and the fracture surfaces were examined by means of microscopic analysis, in which the depth of the flaw and the mirror radius of the fracture were measured and the strength was calculated. These results agreed with those obtained from the fracture mechanics analysis.

Evaluation of Formability Sensitivity to Die Design in Warm Square Cup Deep Drawing of AZ31 Sheet (AZ3l 판재의 온간 사각컵 디프드로잉에서 금형 설계에 대한 성형성 민감도의 평가)

  • Kim, G.D.;Kim, H.K.
    • Transactions of Materials Processing
    • /
    • v.16 no.2 s.92
    • /
    • pp.120-125
    • /
    • 2007
  • Magnesium alloy has low formability at room temperature and therefore, in many cases, forming at elevated temperatures is necessary to obtain the required material flow without failure. Tn the present study, square cup deep drawing tests using the magnesium alloy AE31 sheet were experimentally conducted using the porches and dies with different edge radius to evaluate the formability sensitivity to the die design variables. The experimental results showed that the fracture position over the cup wall moved from the punch nose to the flange as the die temperature increased, and that the drawing depth change was more affected by the punch radius than the die radius.

Micro Cracking and Elastic/Plastic Transition Radii Associated with Indenting on Ceramics by Diamond Indenter (경취재료에 있어 압자압입시의 균열진전에 관한 연구)

  • Park, G.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.5
    • /
    • pp.164-172
    • /
    • 1996
  • In hard and brittle materials as advanced ceramics indented by a hard indenter, the indenter's transition radius, was defined as critical radius which distinguishes the occurrence of the first plastic deformation from the elastic cracking as the first damaging event, is analytically and experimentally investigated. The analytical result is shown that the critical load, which not enlarge pre-existing cracks as the form of median crack beneath a indenter, is constant, and is determined by the order of $k_{IC}$$^{4}$ $P_{Y}$$^{3}$(where, $K_{IC}$ , $P_{Y}$are the fracture toughness of materials and the applied pressure by indenting, respectively). And the size of transiton radii were experimentally obtained with the similar values to the analytical results.lts..

  • PDF

Hematogenous Osteomyelitis Following Open Fracture in a Cat

  • Hwang, Ya-Won;Lee, Jang-Mi;Choi, Seok-Hwa;Kim, Gon-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.33 no.2
    • /
    • pp.135-137
    • /
    • 2016
  • A 6-month-old, weighing 2.8 kg, female, domestic short-haired cat presented with open fracture at right distal radius about a month ago. Based on radiological findings, hyperplasia at the right radioulna and left humerus was found. Results of the cytological examination were inflammatory reaction and reactive osteoblast. Distal radial ostectomy proceeded with necrotic bone debridement. Three weeks after operation, the radial bone lysis was seen on radiograph but clinical condition improved. Hyperplasia at the right radioulna and left humerus was dissolved. Two months after operation, she can use her both forelimbs despite right elbow have been diagnosed as arthrosclerosis because of periosteal reaction. Six months after operation, clinical symptoms of limbs were not detected. In this case, open fracture was treated through delayed surgical debridement procedure, therefore hematogenous osteomyelitis occurs at another forelimb. The longer a wound remains open, the more likely it is that infection will develop. The infection can occur to fracture bone and seed from hematogenous spread to another normal bone. In conclusion, when open fracture occurs, early antibiotic treatment and urgent surgical intervention are recommended.

Classification of Anteroposterior/Lateral Images and Segmentation of the Radius Using Deep Learning in Wrist X-rays Images (손목 관절 단순 방사선 영상에서 딥 러닝을 이용한 전후방 및 측면 영상 분류와 요골 영역 분할)

  • Lee, Gi Pyo;Kim, Young Jae;Lee, Sanglim;Kim, Kwang Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.94-100
    • /
    • 2020
  • The purpose of this study was to present the models for classifying the wrist X-ray images by types and for segmenting the radius automatically in each image using deep learning and to verify the learned models. The data were a total of 904 wrist X-rays with the distal radius fracture, consisting of 472 anteroposterior (AP) and 432 lateral images. The learning model was the ResNet50 model for AP/lateral image classification, and the U-Net model for segmentation of the radius. In the model for AP/lateral image classification, 100.0% was showed in precision, recall, and F1 score and area under curve (AUC) was 1.0. The model for segmentation of the radius showed an accuracy of 99.46%, a sensitivity of 89.68%, a specificity of 99.72%, and a Dice similarity coefficient of 90.05% in AP images and an accuracy of 99.37%, a sensitivity of 88.65%, a specificity of 99.69%, and a Dice similarity coefficient of 86.05% in lateral images. The model for AP/lateral classification and the segmentation model of the radius learned through deep learning showed favorable performances to expect clinical application.

Limit Load and Fully Plastic Stress Analysis for Circular Notched Plates and Bars Using Fully Plastic Analysis (완전소성해석을 이용한 원형노치 인장시편의 한계하중 및 완전소성응력장 해석)

  • Oh Chang-Kyun;Myung Man-Sik;Kim Yun-Jae;Park Jin-Moo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1605-1614
    • /
    • 2005
  • For the last four decades, tension test of notched bars has been performed to investigate the effect of stress triaxiality on ductile fracture. To quantify the effect of the notch radius on stress triaxiality, the Bridgman equation is typically used. However, recent works based on detailed finite element analysis have shown that the Bridgman equation is not correct, possibly due to his assumption that strain is constant in the necked ligament. Up to present, no systematic work has been performed on fully plastic stress fields for notched bars in tension. This paper presents fully plastic results for tension of notched bars and plates in plane strain, via finite element limit analysis. The notch radius is systematically varied, covering both un-cracked and cracked cases. Comparison of plastic limit loads with existing solutions shows that existing solutions are accurate for notched plates, but not for notched bars. Accordingly new limit load solutions are given for notched bars. Variations of stress triaxiality with the notch radius and depth are also given, which again indicates that the Bridgman solution for notched bars is not correct and inaccuracy depends on the notch radius and depth.

Finite Element Analysis of Axisymmetric Hydrostatic Bulging (축대칭 정수압 벌징의 유한요소 해석)

  • Baek, Nam-Ju;Kang, Dae-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.1 no.3
    • /
    • pp.71-84
    • /
    • 1984
  • This paper examined strain distribution and radius of curvature of the bulge by finite element method and investigated limit polar thickness strain to predict the formability of sheet metal as we substituted effective strain and the radius of curvature obtained by FEM into instability condition equation successively. In experiment, the radius of curvature and limit polar thickness strainwere obtained by Moire method. Also, a concent- ric set of photogrid circles was used to measure the strain of arbitrary point and mild steel was used as material. This results obtained are as follows: 1) The radius of curvature obtained by FEM is in good agreement with the Moire experimental value. 2) The polar thickness strain is getting larger as the inside is approached from the edge. This means that fracture occurred near the ploe. 3) The circumferential strains agree closely with the meridian strains and the polar thickness strain is about twice the circumferential (or meridian) strain. This result agrees with the fact that anisotropy coefficient (R-value) obtained by tensile test is about one. 4) The theoretical results of limit polar thickness strain obtained by authors' method are better agreement with experimental results than other theoretical results. Therefore, we can better predict the formability of sheet metal with authors' method.

  • PDF

Fracture Behavior and Stress Distribution around Slot (슬롯주위 의 應力分布 와 破壞擧動 1)

  • 송삼홍;고성위
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.127-132
    • /
    • 1984
  • In this paper, stress concentration factor and distribution of slotted or notched plate which is subjected to uniaxial tensile load are studied. The experimental measurements have shown the following; (1)The stress around slot or notch of slotted or notched plate which is subjected to uniaxial tensile load is state of biaxial stress, which is mainly varied to notch radius and depth. (2)The stress concentration factor around slot or notch is mainly influenced by the .sigma.$_{yy}$ , it is varied with notch radius and depth. (3)For the notched specimen, there is a notch depth where stress concentration factor is maximum. On the other hand, for the slotted specimen, stress concentration factor increases as the notch depth increases. An investigation of the relationship between fracture and stress concentration factor due to the slot or notch will be presented on the later paper, for reference.

A Study on the Elderly Patients Hospitalized by the Fracture from the Fall (낙상 사고에 의한 골절로 입원한 노인 환자에 대한 조사 연구)

  • 전미양;정현철;최명애
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.3
    • /
    • pp.443-453
    • /
    • 2001
  • Purpose: To identify age, gender, medication, seasons and place of fall, and areas of the fractures from the fall among the hospitalized elderly patients in order to provide the basic data for future fall prevention program for the elderly. Methods: This study was conducted for 106 elderly patients admitted into a university hospital by fractures from the fall during the period from January 1, 1999 to December 31, 1999. Data on the age, gender, medication, season and place of the fall, areas of the fracture were collected based on their medical records. Result: The age range of the subjects were from 60 to 96 years old. The subjects were aged between 60-69 years old 49(46.2%), between 70-79 years old 31(29.2%), between 80-89 years old 24(22.6%), and over 90 years old 2(1.9%). Male patients comprised was 34(28.3%), while female patients comprised 76(71.7%). The fall occurred in Winter most frequently 34(32%). The place of the fall included room 81(76.4%), streets 13(12.3%), bathroom 6(5.7%), stair 4(3.8%), and mountain 2(1.9%). Twenty-two subjects (20.8%) had medication regularly, while 84 subjects (79.2%) had no medication. The areas of the fracture from the fall included upper extremities 20(18.9%) and lower extremities 86(81.1%). Radius fracture (7.5%) was the area where the fracture occurred most frequently in upper extremities and femur fracture (52.8%) was the area where the fracture occurred most frequently in lower extremities. A significant difference was found in the fracture area by age, season and place of the fall (p<.05). No significant difference was found in the fracture area by gender and medication. In all age groups, seasons and places of the fall, occurrence of fracture in lower extremity was significantly higher than that in upper extremity.