• Title/Summary/Keyword: radiologists

Search Result 594, Processing Time 0.022 seconds

Comparison of the Efficacy of Diluted Polyethylene Glycol and Low-Density (0.1% w/v) Barium Sulfate Suspension for CT Enterography (전산화단층촬영 소장조영술을 위한 희석된 폴리에틸렌 글리콜과 저밀도(0.1% w/v) 바륨 현탁액의 유용성 비교)

  • Yeon Jung Kim;Seung Ho Kim;Tae Wook Baek;Hyungin Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.911-922
    • /
    • 2023
  • Purpose To compare small bowel distension and side effects between a diluted polyethylene glycol (PEG) solution and a low-density (0.1% w/v) barium sulfate suspension (LDBSS) for CT enterography (CTE) preparation. Materials and Methods Total 173 consecutive patients who underwent CTE were enrolled in this study. The LDBSS (1 L) was used in 50 patients, and the diluted iso-osmotic PEG solution (1 L) was used in 123 patients. Two blinded radiologists independently scored jejunal and ileal distensions on a 5-point scale. To compare side effects between the two groups, the patients reported whether they had immediate complications after the administration of the oral contrast media. Results For ileal and jejunal distension, the diluted PEG solution showed no difference from the LDBSS for either reader (ileum: reader 1, median, 4; 4, interquartile range, 3-4; 3-4, p = 0.997; reader 2, median, 4; 4, interquartile range, 3.3-4.0; 3-4, p = 0.064; jejunum: reader 1, median, 2; 2, interquartile range, 2-3; 2-3, p = 0.560; reader 2, median, 3; 2, interquartile range, 2-3; 2-3, p = 0.192). None of the patients complained of immediate complications following administration of either of the oral contrast media. Conclusion The diluted PEG solution showed comparable bowel distension compared to LDBSS and no immediate side effects; thus, it can be a useful alternative.

Variability of Transrectal Shear Wave Elastography in a Phantom Model (팬텀연구에서 경직장 전단파탄성초음파의 가변성)

  • Jihyun Lee;Seong Kuk Yoon;Jin Han Cho;Hee Jin Kwon;Dong Won Kim;Jun Woo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1110-1122
    • /
    • 2023
  • Purpose This study aimed to assess the variability of transrectal shear wave elastography (SWE) using a designed phantom. Materials and Methods In a phantom, the SWE values were examined by two radiologists using agarose and emulsion silicone of different sizes (1, 2, and 3 cm) and shapes (round, cubic) at three depths (1, 2, and 3 cm), two region of interest (ROI) and locations (central, peripheral) using two ultrasound machines (A, B from different vendors). Variability was evaluated using the coefficient of variation (CV). Results The CVs decreased with increasing phantom size. Significant changes in SWE values included; agarose phantom at 3 cm depth (p < 0.001; machine A), 1 cm depth (p = 0.01; machine B), emulsion silicone at 2 cm depth (p = 0.047, p = 0.020; both machines). The CVs increased with increasing depth. Significant changes in SWE values included; 1 cm agarose (p = 0.037, p = 0.021; both machines) and 2 cm agarose phantom (p = 0.047; machine A). Significant differences in SWE values were observed between the shapes for emulsion silicone phantom (p = 0.032; machines A) and between ROI locations on machine B (p ≤ 0.001). The SWE values differed significantly between the two machines (p < 0.05). The intra-/inter-operator agreements were excellent (intraclass correlation coefficient > 0.9). Conclusion The phantom size, depth, and different machines affected the variability of transrectal SWE.

Diagnostic Performance of Rectal CT for Staging Rectal Cancer: Comparison with Rectal MRI and Histopathology (직장암 병기결정에서 직장 CT의 진단능: 직장 MRI 및 병리결과와의 비교분석)

  • Seok Yoon Son;Yun Seok Seo;Jeong Hee Yoon;Bo Yun Hur;Jae Seok Bae;Se Hyung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1290-1308
    • /
    • 2023
  • Purpose To compare the diagnostic performance of rectal CT with that of high-resolution rectal MRI and histopathology in assessing rectal cancer. Materials and Methods Sixty-seven patients with rectal cancer who underwent rectal CT with rectal distension using sonographic gel and high-resolution MRI were enrolled in this study. The distance from the anal verge/anorectal junction, distance to the mesorectal fascia (MRF), extramural depth (EMD), extramesorectal lymph node (LN) involvement, extramural venous invasion (EMVI), and T/N stages in rectal CT/MRI were analyzed by two gastrointestinal radiologists. The CT findings of 20 patients who underwent radical surgery without concurrent chemoradiotherapy were compared using histopathology. Interclass correlations and kappa statistics were used. Results The distance from the anal verge/anorectal junction showed an excellent intraclass correlation between CT and MRI for both reviewers. For EMD, the distance to the MRF, presence of LNs, extramesorectal LN metastasis, EMVI, T stage, and intermodality kappa or weighted kappa values between CT and MRI showed excellent agreement. Among the 20 patients who underwent radical surgery, T staging, circumferential resection margin involvement, EMVI, and LN metastasis on rectal CT showed acceptable concordance rates with histopathology. Conclusion Dedicated rectal CT may be on par with rectal MRI in providing critical information to patients with rectal cancer.

Imaging for Multiple Myeloma according to the Recent International Myeloma Working Group Guidelines: Analysis of Image Acquisition Techniques and Response Evaluation in Whole-Body MRI according to MY-RADS (International Myeloma Working Group의 최신 가이드 라인에 따른 다발성 골수종의 영상검사법 및 MY-RADS에 따른 전신 MRI에서의 영상 획득과 반응 평가 소개)

  • A Yeon Son;Hye Won Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.150-169
    • /
    • 2023
  • Multiple myeloma (MM) is a malignant hematologic disease caused by the proliferation of clonal plasma cells in the bone marrow, and its incidence is increasing in Korea. With the development of treatments for MM, the need for early diagnosis and treatment has emerged. In recent years, the International Myeloma Working Group (IMWG) has been constantly revising the laboratory and radiological diagnostic criteria for MM. In addition, as whole-body MRI (WBMR) has been increasing used in the diagnosis and treatment response evaluation of patients with MM, the Myeloma Response Assessment and Diagnosis System (MY-RADS) was created to standardize WBMR image acquisition techniques, image interpretation, and response evaluation methods. Radiologists need to have a detailed knowledge of the features of MM for accurate diagnosis. Thus, in this review article, we describe the imaging method for MM according to the latest IMWG guidelines as well as the image acquisition and response evaluation technique for WBMR according to MY-RADS.

Effect of Patient's Positioning on the Grade of Tendinosis and Visible Range of Infraspinatus Tendon on Ultrasound (초음파 영상에서 극하근 힘줄병의 단계와 관찰가능 범위에 환자의 자세가 미치는 영향)

  • Jee Won Chai;Joo-ho Lee;Dong Hyun Kim;Jina Park;So-Hee Oh;Su-Mi Shin
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.627-637
    • /
    • 2023
  • Purpose To investigate the effect of patient positioning on tendinosis grade, visible range, and infraspinatus tendon (IST) thickness, and to determine the feasibility of internal rotation (IR) position to assess IST on ultrasound (US). Materials and Methods This study included 52 shoulders of 48 subjects who were evaluated for IST in three different positions: neutral position (N), IR, and position with the ipsilateral hand on the contralateral shoulder (HC). Two radiologists retrospectively graded IST tendinosis from grade 0 to grade 3 and the visible range from grade 1 to grade 4. The thickness of the IST was measured by another radiologist with a short-axis view. A generalized estimating equation was used for statistical analysis. Results The tendinosis grades were higher in the HC position than in the IR position, with a cumulative odds ratio of 2.087 (p = 0.004, 95% confidence interval [CI]: 1.268-3.433). The tendinosis grades in the HC position (p = 0.370) and IR position (p = 0.146) were not significantly different from those in the N position. The overall difference in IST thickness was significant (p < 0.001), but the visible range (p = 0.530) was not significantly different according to position. Conclusion Patient positioning significantly affected the grade of tendinosis and thickness but not the visible range of the IST. The IR position is a feasible position for assessing the IST on US.

Clustered Microcysts Detected on Breast US in Asymptomatic Women (무증상 여성의 유방초음파에서 발견된 군집 미세낭종)

  • Hyun Jin Kim;Jin Hwa Lee;Young Mi Park;Kyungjae Lim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.676-685
    • /
    • 2023
  • Purpose To investigate the incidence, outcomes, and imaging characteristics of clustered microcysts detected on breast US in asymptomatic women, and suggest appropriate management guidelines. Materials and Methods We identified and reviewed the lesions recorded as "clustered microcysts" on breast US performed in asymptomatic women between August 2014 and December 2019. The final diagnosis was based on pathology and imaging follow-up results for at least 12 months. Results The incidence was 1.5% and 100 patients with 117 lesions were included. Among 117 lesions, 3 (2.6%), 2 (1.7%), and 112 (95.7%) were malignant, high-risk benign, and benign lesions, respectively. The malignant lesions included two cases of ductal carcinoma in situ and one invasive ductal carcinoma. Two of them were assessed as category 4, showing mammographic suspicious microcalcifications and internal vascularity on Doppler US. The remainder was a false negative case and showed echo pattern change on the 12-month follow-up US. Conclusion The incidence of clustered microcysts on breast US in asymptomatic women was 1.5% and malignancy rate was 2.6% (3 of 117). Knowledge of outcomes and imaging features of benign and malignant clustered microcysts may be helpful for radiologists, thereby aiding categorization and management recommendations.

Using Artificial Intelligence Software for Diagnosing Emphysema and Interstitial Lung Disease (폐기종 및 간질성 폐질환: 인공지능 소프트웨어 사용 경험)

  • Sang Hyun Paik;Gong Yong Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.4
    • /
    • pp.714-726
    • /
    • 2024
  • Researchers have developed various algorithms utilizing artificial intelligence (AI) to automatically and objectively diagnose patterns and extent of pulmonary emphysema or interstitial lung diseases on chest CT scans. Studies show that AI-based quantification of emphysema on chest CT scans reveals a connection between an increase in the relative percentage of emphysema and a decline in lung function. Notably, quantifying centrilobular emphysema has proven helpful in predicting clinical symptoms or mortality rates of chronic obstructive pulmonary disease. In the context of interstitial lung diseases, AI can classify the usual interstitial pneumonia pattern on CT scans into categories like normal, ground-glass opacity, reticular opacity, honeycombing, emphysema, and consolidation. This classification accuracy is comparable to chest radiologists (70%-80%). However, the results generated by AI are influenced by factors such as scan parameters, reconstruction algorithms, radiation doses, and the training data used to develop the AI. These limitations currently restrict the widespread adoption of AI for quantifying pulmonary emphysema and interstitial lung diseases in daily clinical practice. This paper will showcase the authors' experience using AI for diagnosing and quantifying emphysema and interstitial lung diseases through case studies. We will primarily focus on the advantages and limitations of AI for these two diseases.

2023 Survey on User Experience of Artificial Intelligence Software in Radiology by the Korean Society of Radiology

  • Eui Jin Hwang;Ji Eun Park;Kyoung Doo Song;Dong Hyun Yang;Kyung Won Kim;June-Goo Lee;Jung Hyun Yoon;Kyunghwa Han;Dong Hyun Kim;Hwiyoung Kim;Chang Min Park;Radiology Imaging Network of Korea for Clinical Research (RINK-CR)
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.613-622
    • /
    • 2024
  • Objective: In Korea, radiology has been positioned towards the early adoption of artificial intelligence-based software as medical devices (AI-SaMDs); however, little is known about the current usage, implementation, and future needs of AI-SaMDs. We surveyed the current trends and expectations for AI-SaMDs among members of the Korean Society of Radiology (KSR). Materials and Methods: An anonymous and voluntary online survey was open to all KSR members between April 17 and May 15, 2023. The survey was focused on the experiences of using AI-SaMDs, patterns of usage, levels of satisfaction, and expectations regarding the use of AI-SaMDs, including the roles of the industry, government, and KSR regarding the clinical use of AI-SaMDs. Results: Among the 370 respondents (response rate: 7.7% [370/4792]; 340 board-certified radiologists; 210 from academic institutions), 60.3% (223/370) had experience using AI-SaMDs. The two most common use-case of AI-SaMDs among the respondents were lesion detection (82.1%, 183/223), lesion diagnosis/classification (55.2%, 123/223), with the target imaging modalities being plain radiography (62.3%, 139/223), CT (42.6%, 95/223), mammography (29.1%, 65/223), and MRI (28.7%, 64/223). Most users were satisfied with AI-SaMDs (67.6% [115/170, for improvement of patient management] to 85.1% [189/222, for performance]). Regarding the expansion of clinical applications, most respondents expressed a preference for AI-SaMDs to assist in detection/diagnosis (77.0%, 285/370) and to perform automated measurement/quantification (63.5%, 235/370). Most respondents indicated that future development of AI-SaMDs should focus on improving practice efficiency (81.9%, 303/370) and quality (71.4%, 264/370). Overall, 91.9% of the respondents (340/370) agreed that there is a need for education or guidelines driven by the KSR regarding the use of AI-SaMDs. Conclusion: The penetration rate of AI-SaMDs in clinical practice and the corresponding satisfaction levels were high among members of the KSR. Most AI-SaMDs have been used for lesion detection, diagnosis, and classification. Most respondents requested KSR-driven education or guidelines on the use of AI-SaMDs.

Assessment of Treatment Response in Patients With Severe Asthma Using Visual and Quantitative Analysis of Chest CT

  • Han Na Lee;Jin An;Miji Lee;Hye Jeon Hwang;Jooae Choe;Jihye Yoon;Ji-Hyang Lee;Min-Hye Kim;Young-Joo Cho;Sang Min Lee;Tae-Bum Kim;Joon Beom Seo
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.673-683
    • /
    • 2024
  • Objective: To evaluate the role of visual and quantitative chest CT parameters in assessing treatment response in patients with severe asthma. Materials and Methods: Korean participants enrolled in a prospective multicenter study, named the Precision Medicine Intervention in Severe Asthma study, from May 2020 to August 2021, underwent baseline and follow-up chest CT scans (inspiration/expiration) 10-12 months apart, before and after biologic treatment. Two radiologists scored bronchiectasis severity and mucus plugging extent. Quantitative parameters were obtained from each CT scan as follows: normal lung area (normal), air trapping without emphysema (AT without emph), air trapping with emphysema (AT with emph), and airway (total branch count, Pi10). Clinical parameters, including pulmonary function tests (forced expiratory volume in 1 s [FEV1] and FEV1/forced vital capacity [FVC]), sputum and blood eosinophil count, were assessed at initial and follow-up stages. Changes in CT parameters were correlated with changes in clinical parameters using Pearson or Spearman correlation. Results: Thirty-four participants (female:male, 20:14; median age, 50.5 years) diagnosed with severe asthma from three centers were included. Changes in the bronchiectasis and mucus plugging extent scores were negatively correlated with changes in FEV1 and FEV1/FVC (ρ = from -0.544 to -0.368, all P < 0.05). Changes in quantitative CT parameters were correlated with changes in FEV1 (normal, r = 0.373 [P = 0.030], AT without emph, r = -0.351 [P = 0.042]), FEV1/FVC (normal, r = 0.390 [P = 0.022], AT without emph, r = -0.370 [P = 0.031]). Changes in total branch count were positively correlated with changes in FEV1 (r = 0.349 [P = 0.043]). There was no correlation between changes in Pi10 and the clinical parameters (P > 0.05). Conclusion: Visual and quantitative CT parameters of normal, AT without emph, and total branch count may be effective for evaluating treatment response in patients with severe asthma.

Analysis of Observer Agreement in Shear Wave Elastography using a Breast Phantom (유방 팬텀을 활용한 전단파 탄성초음파 검사에서의 관측자 일치도 분석)

  • Jin-Hee Kim;Jung-Hoon Kim;Sung-Hee Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.355-363
    • /
    • 2024
  • This study evaluated the clinical utility of Shear Wave Elastography(SWE) by analyzing the differences in elastic modulus and shear wave speed across various types of breast tissue and assessing inter-observer agreement. A breast phantom that included normal breast tissue, benign tumors, and malignant tumors was utilized, and ten radiologists participated, measuring the minimum, average, and maximum elastic modulus and shear wave speed for each tissue type. Analysis of differences between tissues was conducted using one-way ANOVA, and intra- and inter-observer agreement was assessed using the Intraclass Correlation Coefficient(ICC). The results demonstrated significant differences in the average values of elastic modulus and shear wave speed among the tissue types(p<0.001), with malignant tumor tissues showing the highest average values. Furthermore, the ICC analysis for elastic modulus ranged from 0.75 to 0.99 and for shear wave speed from 0.89 to 0.99, indicating high reproducibility and agreement. These findings suggest that SWE is a reliable tool with high reproducibility and specificity for the diagnosis of breast cancer.