Quasi-monochromatic Parallel Radiography Achieved with a Polycapillary Plate

  • Sato, Eiichi;Komatsu, Makoto;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Ichimaru, Toshio;Takayama, Kazuyoshi;Ido, Hideaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.418-421
    • /
    • 2002
  • Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.

  • PDF

Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구 (A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System)

  • 홍선숙;김호철
    • 전자공학회논문지
    • /
    • 제50권12호
    • /
    • pp.247-253
    • /
    • 2013
  • 본 연구의 목적은 Direct DR(Digital Radiography), Indirect DR, I.I(Image Intensifier) DR에서 X선 광자 검출 방식에 따른 선량측정 및 획득된 영상을 정량적이고 객관적인 측정을 통해 DR System을 비교 평가 하는 것이다. Rando phantom을 사용하여 입사표면선량을 측정하였으며, 측정된 입사표면선량 값을 통해 PCXMC 프로그램을 사용하여 유효선량과 방사선 조사로 인한 위험을 평가하였다. 21cm 아크릴 phantom을 사용하여 SNR(Signal to Noise Ratio), NPS(Noise Power Spectrum), CNR(Contrast to Noise Ratio)을 측정하였으며, 측정값은 통계학적 분석기법을 사용하여 유의성을 평가하였다. 입사표면선량, 주요장기선량, 유효선량 모두 direct DR이 가장 낮게 측정되었으며, direct DR 선량을 기준으로 I.I type DR은 약 1.3배, indirect DR은 약 2.4배 높은 선량 비율로 측정되었다. 방사선량에 따른 위험도 역시 동일한 비율로 측정되었다. SNR 측정 결과 direct DR측정값을 기준으로 I.I DR은 약 7.25배, indirect DR이 약 1.48배 낮은 비율로 측정되었다. CNR 측정 결과 direct DR 측정값을 기준으로 I.I DR은 약 1.16배 높고, indirect DR이 약 0.87배 낮은 비율로 측정되었다. 따라서 a-selenium 검출소자를 사용하여 X선 광자를 검출하는 방식인 direct DR은 적은 선량으로 우수한 화질의 영상을 구현함으로써 선량에 민감한 소아나 생식선이 포함된 검사 등에 유용할 것으로 사료된다. 또한 많은 진단 정보를 위한 영상 평가가 요구되는 경우에는 indirect DR이 유용할 것으로 판단된다.

비인두암 토모테라피 시 체중 감소에 따른 피부선량 변화 분석 (Analysis of Changes in Skin Dose During Weight Loss when Tomotherapyof Nasopharynx Cancer)

  • 장준영;김대현;최천웅;김보희;박철수
    • 한국자기학회지
    • /
    • 제26권3호
    • /
    • pp.99-104
    • /
    • 2016
  • 항암요법과 방사선치료를 병행하여 두경부암을 치료하는 환자의 경우 항암요법과 방사선치료를 거듭할수록 구토, 메스꺼움, 식욕부진 등의 이유로 환자의 체중 감소가 생기게 된다. 체중 감소는 목의 두께 변화로 나타날 수 있으며 이로 인해 치료하고자 하는 t 타겟과 주위 정상조직의 선량 전달에도 영향을 미치며 방사선이 전달되는 방향에 위치한 피부선량의 변화가 나타날 것으로 사료된다. 특히 비인두암 환자의 경우 비인두 구조가 다른 장기보다 복잡한 구조를 지니고 있고 치료방법인 토모테라피는 수 mm 차이로 급격한 선량 변화가 발생하므로 이러한 체중 감소의 변화에 주의 깊은 관찰이 필요하다. 현재 토모테라피의 경우 매 회 치료 전 정확한 자세 재현을 위한 영상 검증을 통해 이러한 움직임을 확인하고 그 값을 보정하여 치료를 수행한다. 그러나 환자의 체중 감소로 인하여 피부선량에 전달되는 선량 변화의 검증은 되지 않고 있다. 환자의 피부선량이 증가함으로써 나타나는 부작용은 환자의 삶의 질에 영향을 미칠 뿐 만 아니라 2차 암 발생률을 높일 수 있다. 이에 환자의 체중 감소로 인하여 나타나는 환자의 목 두께를 휴먼 팬톰에 볼루스를 올리고 두께를 조절해가며 변화시켜 필름을 이용하여 피부선량의 변화가 어떻게 나타나는지 분석해보고자 한다.

진단용 방사선 안전관련 법령의 법체계상 문제점 (Problems of the Legal System Related to the Regulation of Radiation Safety for Diagnosis)

  • 임창선;문홍안
    • 의료법학
    • /
    • 제14권2호
    • /
    • pp.119-142
    • /
    • 2013
  • It is not easy to regulate the amount of radiation used for the medical purpose as there usually is more good than harm to the patient's health and life caused by the medical exposure to the radiation. However, the rapid increase of the use of diagnostic radiation involves a high possibility of increasing the radiation hazard exposure. Therefore, it is imperative to implement effective regulations in order to secure the safety of diagnostic radiation. The one and only rule we currently have for the diagnostic radiation is "Medicine Act" with only one clause dedicated to regulate the safety management that does not include any rules for the medical radiation. A set of inclusive rules for the whole medical radiation inclusive of diagnostic radiation and therapeutic radiation need to be based on the "Medicine Act" rather than "Nuclear Safety Act" in order to protect the medical professionals, patients and the guardians of patients from the hazards of diagnostic and/or therapeutic radiation that was not used the purpose of medical treatment. If there is an administrative measure to be imposed to secure the safety of diagnostic radiation, it is considered as exertion of governmental authority of administrative agency. There must be clear and realistic legal guidelines for in-fringe on people's interests. The administrative measures for the safety management of the diagnostic radiation must be clearly and specifically based on the law and the detailed standards for the administrative measures must be dele-gated by the presidential decree or departmental ordinance. Accordingly, the restrictions imposed by the administrative measures to the "Safety Inspection Institute of Radiation along with Radiation Exposure Measuring Institutes" should have clear legal basis as well and the detailed standards for the administrative measures should be regulated by the Ministry of Health and Welfare decree instead of the notification by the Director of Korean Centers for Disease Control and Prevention. While securing the safety of radiation on one side, careful review and up-grade on our legal system for the safety management of the diagnostic radiation is required on the other side to guarantee the legality, interest balance and reliability of the administrative measures.

  • PDF

비등방성 2차원 확산 기반 필터를 이용한 전산화단층영상 품질 개선 (Image Quality Improvement in Computed Tomography by Using Anisotropic 2-Dimensional Diffusion Based Filter)

  • 성열훈
    • 한국방사선학회논문지
    • /
    • 제10권1호
    • /
    • pp.45-51
    • /
    • 2016
  • 본 연구에서는 비등방성 2차원 확산 기반 필터를 이용하여 전산화단층영상(computed tomography, CT)의 노이즈 제거와 공간분해능을 향상하고자 하였다. 실험은 4-채널 다중검출기 전산화단층영상기기(4-channel multi-detector computed tomography, MDCT)를 이용하였으며, CT 영상품질 평가를 위해 미국 의학물리학자협의회(american association of physicists in medicine, AAPM) CT 성능 평가용 팬톰을 사용하였다. X-선 조사 조건은 120 kVp, 100 mAs로 고정한 후 ultra-high resolution으로 10 mm 축 방향 스캔 하였다. 본 연구에서 제안한 비등방성 2차원 확산 기반 필터는 원 영상에 각 픽셀에 가중치 1.2를 곱하고 0.4% 히스토그램 스트레칭을 통해 영상의 대조도를 증가시킨 후 비등방성 2차원 확산 필터를 적용하였다. 그 결과, 공간분해능은 원 영상에서 0.75 mm까지 구분되었지만 제안한 비등방성 2차원 확산 기반 필터 영상에서는 0.40 mm까지 구분되었다. 원 영상의 노이즈는 46.0, 제안한 비등방성 2차원 확산 기반 필터 영상의 노이즈는 33.5로 27.2%가 감소하였다. 우리가 제안한 비등방성 2차원 확산 기반 필터는 CT의 노이즈 제거와 공간분해능을 향상시킬 수 있었다.

뇌 확산텐서 자기공명영상을 이용한 청소년 인터넷 중독자의 백질 섬유로에 관한 연구 (A Study of Whiter Matter Fiber Tractography in Young Internet Addiction Disorder using a Brain Diffusion Tensor Magnetic Resonance Imaging)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제10권1호
    • /
    • pp.7-13
    • /
    • 2016
  • 3.0 T 자기공명영상기기에서 확산텐서영상을 이용하여 청소년을 대상으로 정상인과 인터넷 중독자의 뇌량과 내섬유막 구조의 변화에 대하여 정량적으로 알아보고자 하였다. 10명의 인터넷 중독자와 정상인 12명을 대상으로 검사를 하였고, 정량적 분석을 위하여 뇌량의 5부위와 내섬유막의 2부위를 View Forum 프로그램을 이용하여 두 그룹에 대한 신경섬유의 손상 정도를 FA, ADC($10^{-3}mm^2/s$), Length(mm)값으로 측정하였다. 그룹 간 통계적 유의성은 Independent t-test와 pearson 상관관계로 하였다(p<0.05). 정상인과 인터넷 중 독자에 관하여 신경섬유 손상정도는 7부위에 대하여 FA, ADC($10^{-3}mm^2/s$), Length(mm)값에 대하여 의미 있는 차이를 보였다(p<0.05). 또한 두 그룹에서 IAD scale 과 뇌량의 FA값은 음의 적으로 강하게 상관관계가 있었다(p<0.000). 결론적으로, 확산텐서영상은 FA, ADC($10^{-3}mm^2/s$), Length(mm)값에 대하여 유의성 있는 차이를 보여고, 이 결과는 뇌 백질에 대한 손상정도에 관하여 정량적으로 임상적 정보를 제공하였다.

방사선치료 시 환자의 심리적 상태의 변화 양상 (Mental Status Change of Patients Receiving Radiation Therapy)

  • 양은주;이승철;김영재
    • 한국방사선학회논문지
    • /
    • 제11권2호
    • /
    • pp.123-130
    • /
    • 2017
  • 암(caner)라는 중증의 질환을 가지고 있는 환자의 경우, 방사선 치료시 받을 수 있는 불안감, 폐쇄적 공포심을 알아보려 하였다. 연구의 대상은 각각 선형가속기의 치료, 토모테라피 치료를 받는 환자를 대상으로 하였으며 연구의 방법은 설문조사의 방법으로 시행을 하였다. 설문의 내용은 치료시간별로 조사 하였고, (5분 이내의 치료시, 10분이내, 20분 이상, 30분 이상), 장비의 고장으로 인한 치료실 및 치료기기 변경의 경험에 대한 설문조사를 시행하였다. 설문에 성실히 응답한 200개의 설문지를 연구한 결과 방사선치료의 경험이 없을수록 불안감이 많았으며 그 이유로는 치료시 고틍이 있을 것 같다는 의견이 지배적이었다. 치료기로는 선형가속기가 가장 불안감이 높았으며 이유는 환자의 테이블의 개방감 때문인 것으로 나타났다. 가장 안정적인 상태는 토모테라피 치료를 20분 이상 30분 미만 시행한 경우였으며 치료시 토모테라피 치료장비의 아늑함이 원인이었다. 30분이 초과된 경우는 외부와 분리에 대한 불안감으로 불안한 심리상태를 보였다. 본 논문을 통하여 임상에서는 환자의 만족도를 높이는 양질의 의료서비스를 제공하기 위한 제반 자료로 활용되길 기대해 본다.

조영제 주입 전 1.5T 와 3.0T를 이용한 복부장기 자기공명영상에서 영상의 질 비교 (Comparison of Image Quality in Magnetic Resonance Imaging of the Abdominal Organ at 1.5T and 3.0T before the Gadolinium Injection)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.619-625
    • /
    • 2017
  • 본 연구는 조영제 주입 전 복부 검사 시 필수적으로 적용되고 있는 HASTE, HASTE(f/s), FFE(in, out)를 중심으로 두 기기에 대한 복부장기의 신호 대 잡음비(SNR; Signal to Noise Ratio)와 대조도 대 잡음비(CNR; Contrast to Noise Ratio)를 정량적으로 평가함으로서 최적의 장비선택을 알아보고자 하였다. 데이터분석은 1.5T 와 3.0T 자기공명영상기기(Philips medical system, Netherland)를 이용하여 검사한 복부영상을 무작위로 선정하여 분석을 하였다. 정량적 분석결과 간(Liver), 신장(Kidney), 비장(Spleen)에서는 1.5와 비교했을 때 3.0T가 SNR, CNR 값이 높게 나타났고(p<0.05), 위(Stomach), 복부지방(Abdominal Fat), 췌장(Pancreas)에서는 1.5T 가 높은 결과를 얻었다(p<0.05). 결론적으로 두기기별 장기에 대한 정량적 평가를 했을 때 인체의 바같 부분 조직은 전반적으로 3.0T 가 높게 나타났고 가스를 포함하여 자화율의 차이를 많이 발생시키는 안쪽부분의 장기는 1.5T 가 높은 결과를 얻었다. 이러한 결과는 환자상태에 따라 조영제를 사용하지 못하고 MRI 검사를 하는 경우 정확한 진단학적 정보를 제공하는데 가이드라인이 될 것이다.

DR 시스템에서 화질 개선을 위한 VGR 알고리즘의 유용성에 관한 연구 (A Study on the Usefulness of VGR (Virtual Grid Role) Algorithm for Elevation of Image Quality in DR System)

  • 양현진;한동균
    • 한국방사선학회논문지
    • /
    • 제14권6호
    • /
    • pp.763-772
    • /
    • 2020
  • DR 시스템에서 일반X선 검사 시 환자에 의해 물리적으로 발생되는 산란X선으로 인하여 영상의 흐림 현상으로 인해 질 저하를 초래한다. 현재 임상에서는 격자를 사용하여 물리적으로 발생한 산란X선을 제거하여 영상의 대조도를 높이지만, 이로 인해 촬영조건이 증가되기 때문에 환자의 피폭선량이 증가되고 격자에 의한 아티팩트가 생길 가능성이 있다. 따라서, 본 연구에서는 가상 격자 역할을 하는 VGR (virtual grid role) 알고리즘을 사용하여 Non-grid 수준의 촬영조건을 가지고 Real-grid를 사용했을 때와 유사한 영상을 얻어내는데 목적이 있다. Real-grid 영상의 70%의 촬영조건을 가지고 획득한 Non-grid와 VGR 알고리즘 영상의 MTF, SNR, CNR을 비교한 결과 Non-grid와 GLE 알고리즘은 MTF0.5는 0.265와 0.350, MTF0.1은 0.412와 0.467로 차이가 나타났으며 SNR과 CNR도 차이가 있음을 보여줬다. 또한, VGR 알고리즘과 Real-grid 영상의 MTF, SNR, CNR을 비교한 결과 VGR 알고리즘과 Real-grid는 MTF0.5는 0.350과 0.367, MTF0.1은 0.467와 0.483으로 차이가 거의 없었으며 SNR과 CNR도 차이가 거의 없음을 보여줬다.

자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향 (Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System)

  • 정민규;성열훈
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.635-642
    • /
    • 2020
  • 본 연구에서는 자동노출제어장치(automatic exposure control, AEC)의 채광창 차폐정도와 농도, 감도가 관전류량과 영상품질에 미치는 영향을 분석하였다. 실험에 사용된 장비는 X선관과 간접방식의 디지털검출기가 일체형인 디지털방사선발생장치(Digital Diagnost, Philips, Netherlands)를 사용하였다. 채광창 차폐정도는 3 mm 두께의 납을 이용하여 0%부터 100%까지 12.5%씩 순차적으로 누적 차폐하여 9단계로 구분하였다. 농도는 제조사에서 제시한 3단계(+2.5, 0, -2.5)와 감도 3단계(S200, S400, S800)를 대상으로 하였다. 관전류량 평가는 관전압을 40 kVp로 고정하고 AEC 조절인자들이 교차한 81가지의 조합조건에서 자동 노출된 관전류량을 측정하였다. 영상품질평가는 자체 제작한 원뿔형 피라미드 팬텀의 방사선영상을 육안 평가하여 유효한 영상을 선발하였고 이들의 신호 대 잡음비(signal to noise ratio, SNR)을 측정하였다. 그 결과 관전류량은 채광창 차폐정도가 100%, 감도 S200, 농도 2.5일 때 60.0 mAs로 가장 많이 조사되었으며, 채광창 차폐정도가 0%, 감도 S800, 농도 -2.5일 때 0.9 mAs로 가장 적게 조사되었다. SNR은 채광창 차폐정도가 0%, 감도 S200, 농도 2.5일 때 25.2로 가장 우수하였고, 채광창 차폐정도가 25%, 감도 S800, 농도 -2.5일 때 SNR이 4.7로 가장 낮았다.