• Title/Summary/Keyword: radiological science

Search Result 3,854, Processing Time 0.033 seconds

Activity concentrations and radiological hazard assessments of 226Ra, 232Th, 40K, and 137Cs in soil samples obtained from the Dongnam Institute of Radiological & Medical Science, Korea

  • Jieun Lee;HyoJin Kim;Yong Uk Kye; Dong Yeon Lee;Wol Soon Jo;Chang Geun Lee;Jeung Kee Kim;Jeong-Hwa Baek;Yeong-Rok Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2388-2394
    • /
    • 2023
  • The radioactivity concentration of environmental radionuclides was analyzed for soil and sand at eight locations within a radius of 255 m centered on the Dongnam Institute of Radiological & Medical Science (DIRAMS), Korea. The average activity concentrations of 40K, 137Cs, 226Ra, and 232Th were 661.1 Bq/kg-dry, 0.9 Bq/kg-dry, 21.9 Bq/kg-dry, and 11.1 Bq/kg-dry, respectively. The activity of 40K and 137Cs was lower than the 3-year (2017-2019) average reported by the Korea Institute of Nuclear Safety, respectively. Due to the nature of granite-rich soil, the radioactivity of 40K was 0.6-fold higher than in other countries, while 137Cs was in the normal fluctuation range (15-30 Bq/kg-dry) of the concentration of radioactive fallout from nuclear tests. The activity of 226Ra and 232Th was lower than in Korean soils reported by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). The average activity concentrations of 232Th and 40K for the soil and sand samples from DIRAMS were within the range specified by UNSCEAR in 2000. The radium equivalent activity and internal and external hazard index values were below the recommended limits (1 mSv/y). These radionuclide concentration (226Ra, 232Th, 40K, and 137Cs) data can be used for regional environmental monitoring and ecological impact assessments of nuclear power plant accidents.

Evaluation of Linearity Air Kerma Applied to the IEC 60601-2-45 Standard in Mammographic X-ray (유방촬영용 X선 진단장치에서 IEC 60601-2-45 표준규격을 적용한 직선성 평가)

  • Hong, Dong-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan;Han, Beom-Hee;Han, Sang-Hyun;Lee, Sang-Ho;Mo, Eun-Hee;Kim, Ki-Jung;Lee, Mi-Hwa;You, In-Gyu
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • The quality control items of mammography devices in South Korea do not include the linearity, which is required by international standards. The linearity is a requirement for the adjustment of radiation dose and radiation quality. This study tested the linearity, which was suitable for the IEC 60601-2-45 standard, of the 5 mammography devices. All showed adequate results. Consistent measurement management is required for more developed quality control in the future.

Recognition difference and improvement direction of the radiological technologists and patient against medical service in department radiology - In-chon area in the object - (방사선과 보건의료서비스에 대한 방사선사와 환자의 인식차이 및 개선방향 - 인천지역을 중심으로 -)

  • An, Sung-Min;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.93-98
    • /
    • 2006
  • Satisfaction of the patient against the medical service in department of radiology and it evaluated the different recognition of radiological technologist and patient. and investigates it's improvement direction. It sent the reply the above the which is a usual result in question result of the most that, the receipt process it was complicated in the portion which is insufficient,"The receipt process is complicated", "waiting time is long"and "don't radiation protection for patient and guardian". Also these a facts was recognizing patients and radiological technologist all. And the effort of the radiological technologist is necessary with the method which reduces a recognition difference. The periodical medical service satisfaction investigates and must endeavor in reform measure preparation.

  • PDF

An Analysis of Relationship Between Personal Factors of Radiological Technologists and Job Stressors (방사선사의 개인적 요인이 직무스트레스원에 영향을 주는 관련성 분석)

  • Jung, Hong-Ryang;Kim, Jeong-Koo;Lim, Cheong-Hwan;Kim, Myeong-Soo;Kwon, Dae-Cheol;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.45-53
    • /
    • 2005
  • This study is aimed at analyzing the relationship between personal factors of radiological technologists and their job stressors. For this aim, a survey was conducted by means of 890 questionnaires from the middle of July to the end of August 2003 to the subjects of radiological technologists who are working for 44 general hospitals in 16 cities and provinces across the country. The results of the survey could be summed up as follows: 1. The biggest stressor that affects a radiological technologist personally under the working situation turned out to be position, job satisfaction and physical symptom(p<0.001), while job satisfaction and physical symptom also played an important role in personal relationship(p<0.001). 2. In terms of job conflicts, colleagues, immediate seniors, job satisfaction and physical symptoms appeared to exercise great impact(p<0.001), As for job autonomy, age, position and job satisfaction were known to be heavily influential(p<0.001). 3. With regard to job load, job satisfaction and behavioral symptom turned out to have great influence while, in job stability, position and job satisfaction seemed to be immensely influential(p<0.001). The present study has a limit in that it covers only radiological technologists who are working at the 3rd reference hospitals but excludes those who are working at the first and second reference hospitals. The findings, however, are surely believed to be able to serve as basic data to improve the medical service quality as they will help reduce the stressors of and enhance mental and physical health for radiological technologists who play important roles as teammates with expertise in the medical field. These outcomes could also be referred to in future studies in this area.

  • PDF

Evaluation of Usefulness and Fabrication of Femur Phantom on Quality Control of Bone Mineral Density Using 3D Printing Technology (3D 프린팅기술을 이용한 골밀도 정도관리 대퇴골 팬텀 제작 및 유용성 평가)

  • Da-Yeong, Hong;Jeong, Lee;Jun-Ho, Lee;Jae-Won, Mun;Han-Saem, Oh;Yu-Won, Jeong;Seong-Hyun, Jin;Jong-Min, Hong;In-Ja, Lee
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • As the demand for bone mineral density testing increases in Korea, which is close to an aging society, it is necessary to evaluate the repeatability of equipment such as femur phantom other than l-spine for more accurate diagnosis. However, in clinical practice, it is often not possible to proceed such evaluation due to insufficient quality control conditions. Therefore, this study is to evaluate the usefulness of the femur phantom after fabricating the same using 3D printing technology. The femur phantom was output using GlowFill filament and FDM 3D printing type. Each phantom was repeatedly scaned 20 times to compare whether the existing l-spine phantom and the fabricated femur phantom were suitable as a phantom for quality control. Each time the seven researchers took three times, the location of the femur phantom was readjusted, and then scanned to confirm the error between the researchers. As a result of conducting repeatability evaluation using femur phantom, the coefficient of variation rate was 2%, which was within the minimum precision tolerance of 2.5%. The reproducibility between the researcher was also found to be suitable as the average coefficient of variation was 0.031 and the coefficient of variation rate was 3.1%, which was within the minimum precision error range of 5%. In conclusion, it is considered that the prospective attitude and usefulness of the femur phantom fabricated by 3D printing in clinical practice will be sufficient.

Analysis of Radioactivity Concentration at Beaches in the Yeongnam Region, Republic of Korea (대한민국 영남지역 해수욕장의 방사능 농도 분석)

  • Jeong-Ho An;Jin-Gu Kang;Jun-Su Kim;Bo-Yeon Kim;Ja-Young Baek;Min-Su Seol;Seul-Ki Cho;Ye-Eun Kim;Yu-Min Lee;Jong-Soo Choi;Jae-Hwan Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1197-1205
    • /
    • 2023
  • In this study, the spectrum due to radioactivity contained sand samples from famous beaches in the Yeongnam region was measured. The sand samples were from eight famous beaches in Yeongnam region and were placed into a high-purity germanium detector (HPGe) using with an electric field, which is a semiconductor detector and subjected to a precision analysis of the gamma-rays emitted from the radionuclides in the sand by using a multichannel analyzer (MCA). To measure the concentration of the radionuclides, we obtained a spectrum by analyzing the gamma-rays emitted from the radionuclides for a measurement time of 8,000 seconds. As a result of analyzing the spectrum table, Tl-208 had the highest radioactivity at all eight beaches: A, B, C, D, E, F, G, and H. In conclusion, radionuclides detected in sand samples from beaches in the Yeongnam region are natural radionuclides, but they can affect the inside of the human body. Therefore, there is a need for continuous investigation.

Evaluation of Adult Lung CT Image for Ultra-Low-Dose CT Using Deep Learning Based Reconstruction

  • JO, Jun-Ho;MIN, Hyo-June;JEON, Kwang-Ho;KIM, Yu-Jin;LEE, Sang-Hyeok;KIM, Mi-Sung;JEON, Pil-Hyun;KIM, Daehong;BAEK, Cheol-Ha;LEE, Hakjae
    • Korean Journal of Artificial Intelligence
    • /
    • v.9 no.2
    • /
    • pp.1-5
    • /
    • 2021
  • Although CT has an advantage in describing the three-dimensional anatomical structure of the human body, it also has a disadvantage in that high doses are exposed to the patient. Recently, a deep learning-based image reconstruction method has been used to reduce patient dose. The purpose of this study is to analyze the dose reduction and image quality improvement of deep learning-based reconstruction (DLR) on the adult's chest CT examination. Adult lung phantom was used for image acquisition and analysis. Lung phantom was scanned at ultra-low-dose (ULD), low-dose (LD), and standard dose (SD) modes, and images were reconstructed using FBP (Filtered back projection), IR (Iterative reconstruction), DLR (Deep learning reconstruction) algorithms. Image quality variations with respect to varying imaging doses were evaluated using noise and SNR. At ULD mode, the noise of the DLR image was reduced by 62.42% compared to the FBP image, and at SD mode, the SNR of the DLR image was increased by 159.60% compared to the SNR of the FBP image. Based on this study, it is anticipated that the DLR will not only substantially reduce the chest CT dose but also drastic improvement of the image quality.

MR-based Partial Volume Correction for $^{18}$F-PET Data Using Hoffman Brain Phantom

  • Kim, D. H.;Kim, H. J.;H. K. Jeong;H. K. Son;W. S. Kang;H. Jung;S. I. Hong;M. Yun;Lee, J. D.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.322-323
    • /
    • 2002
  • Partial volume averaging effect of PET data influences on the accuracy of quantitative measurements of regional brain metabolism because spatial resolution of PET is limited. The purpose of this study was to evaluate the accuracy of partial volume correction carried out on $^{18}$ F-PET images using Hoffman brain phantom. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices of the same phantom. All the MR slices of the phantom were then segmented to be binary images. Each of these binary images was convolved in 2 dimensions with the spatial resolution of the PET. The original PET images were then divided by the smoothed binary images in slice-by-slice, voxel-by-voxel basis resulting in larger PET image volume in size. This enlarged partial volume corrected PET image volume was multiplied by original binary image volume to exclude extracortical region. The evaluation of partial volume corrected PET image volume was performed by region of interests (ROI) analysis applying ROIs, which were drawn on cortical regions of the original MR image slices, to corrected and original PET image volume. From the ROI analysis, range of regional mean values increases of partial volume corrected PET images was 4 to 14%, and average increase for all the ROIs was about 10% in this phantom study. Hoffman brain phantom study was useful for the objective evaluation of the partial volume correction method. This MR-based correction method would be applicable to patients in the. quantitative analysis of FDG-PET studies.

  • PDF