Design of a Depth Encoding Detector using Light Guides with Different Reflector Patterns for Each Layer (각 층별 반사체 패턴이 서로 다른 광가이드를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.31-36
    • /
    • 2023
  • Among imaging and treatment devices for small animals, positron emission tomography(PET) causes a change in spatial resolution within a field of view. This is a phenomenon caused by using a small gantry and a thin and long scintillation pixel, and detectors that measure the interaction depth are being developed and researched to solve this problem. In this study, a detector that measures the interaction depth was designed using several scintillator blocks and light guides with different reflector patterns. The scintillator block composed of 4 × 4 arrays of 3 mm × 3 mm × 5 mm scintillation pixels formed four layers, and a light guide was inserted in each layer to configure the entire detector. In order to check whether the interaction depth was measured, a gamma ray interaction was generated at the center of all scintillation pixels to acquire data and then reconstructed into a flood image. The reflector patterns of the light guides inserted between the layers were all different, so the positions of the scintillation pixels for each layer were formed in different locations. It is considered that even spatial resolution can be achieved over all regions of the field of view if all positions of the scintillation pixels thus formed are separated and used for image reconstruction.

DOI Detector Design using Different Sized Scintillators in Each Layer (각 층의 서로 다른 크기의 섬광체를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.11-16
    • /
    • 2023
  • In preclinical positron emisson tomography(PET), spatial resolution degradation occurs outside the field of view(FOV). To solve this problem, a depth of interaction(DOI) detector was developed that measures the position where gamma rays and the scintillator interact. There are a method in which a scintillation pixel array is composed of multiple layers, a method in which photosensors are arranged at both ends of a single layer, a method in which a scintillation pixel array is constituted in several layers and a photosensor is arranged in each layer. In this study, a new type of DOI detector was designed by analyzing the characteristics of the previously developed detectors. In the two-layer detector, different sizes of scintillation pixels were used for each layer, and the array size was configured differently. When configured in this form, the positions of the scintillation pixels for each layer are arranged to be shifted from each other, so that they are imaged at different positions in a flood image. DETECT2000 simulation was performed to confirm the possibility of measuring the depth of interaction of the designed detector. A flood image was reconstructed from a light signal acquired by a gamma-ray event generated at the center of each scintillation pixel. As a result, it was confirmed that all scintillation pixels for each layer were separated from the reconstructed flood image and imaged to measure the interaction depth. When this detector is applied to preclinical PET, it is considered that excellent images can be obtained by improving spatial resolution.

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.

A Study on the Lead(Pb) Shield Thickness per Electron Beam Energy in Radiotherapy (방사선 치료용 전자선의 에너지별 납(Pb) 차폐체 두께 측정)

  • Gha-Jung, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.719-725
    • /
    • 2022
  • This study aimed to measure, quantitatively evaluate, and set the criteria for the minimum lead(Pb) shield thickness per level of clinically applied electron beam energy. The lead shield thickness per electron beam energy was measured using the primary field 95% reduction based on the open field at the depth of maximum dose (dmax) and depth from the surface as the reference depth of tissue dose(10 mm). The measured values were 1.906 mmPb and 1.992 mmPb at the dmax and 10 mm, respectively, regarding the lead shield thickness for 6 MeV electron beam; 2.746 mmPb and 3.743 mmPb for 9 MeV electron beam, 3.718 mmPb and 6.093 mmPb for 12 MeV electron beam, 7.300 mmPb and 15.270 mmPb for 16 MeV electron beam, and 16.825 mmPb and 25.090 mmPb for 20 MeV electron beam. Consequently, a thicker lead shield was required if the measurement was at 10 mm. The required lead shield thickness was also higher than that of the theoretical formula for electron beams of ≥ 16 MeV.

Two Layer DOI Detector Design for PET using Multiple Light Guides for Designing Light Distribution (다수의 광가이드를 통한 빛 분포 설계로 두 층의 반응 깊이를 측정하는 양전자방출단층촬영기기의 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.703-708
    • /
    • 2022
  • A detector module measuring the depth of interaction(DOI) was designed to improve the spatial resolution of positron emission tomography(PET). The scintillation pixel array consists of two layers, and a light guide is inserted between the layers to make the light generated through the gamma-ray event different for each layer. There are four light guides, and one light guide is designed to be coupled to a 2 × 2 array of scintillation pixels. The light generated from the top layer is moved to the photosensor with a wider distribution through the light guide, and the light generated from the bottom layer is incident on the photosensor with a narrower distribution than the top layer. When a flood image is reconstructed based on the signals obtained from the photosensor by different distributions, scintillation pixels are imaged at different positions for each layer. To verify this, a DETECT2000 simulation tool that simulates the behavior of light in a scintillator was used. By designing a scintillation pixel array, a detector consisting of a light guide and a photosensor, a gamma ray event was generated in all scintillation pixels to obtain a flood imgae. As a result, it was confirmed that the top and bottom layers were imaged at different positions and completely separated. When this detector is applied to PET, it is considered that image quality can be improved through imporved spatial resolution.

Quality Control and Image Quality Comparison according to Ultrasonic Equipment (초음파 장비에 따른 정도관리와 화질 비교)

  • Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.935-942
    • /
    • 2022
  • In doing interventional treatment under the guidance of ultrasonography, the medical team detects the legion site with ultrasonic equipment at first, and insert angio needle. In this situation, if the position of legion and the depth of inserted needle on the ultrasonographic screen are different from real position and depth, the needle is likely to damage a major blood vessel or tissue. Accordingly, we had wondered how much such differences between screen image and reality, and so decided to examine them. Using five ultrasonographic equipments manufactured from different companies in different years, this study tried to compare the lengths of the needle on the screen images and real lengths of it, and find out the factors affecting skewness of them. This study used hog meat chunk to mimic human flesh, and sausages as the target of needle. It compared penetrating depths of the needle as the images on the five equipments using single sample t test in the SPSS 22 statistical program. It was found that all the errors were statistically significant(<.05). So, this study decided that it was wrong to evaluate performances of the equipments by the makers and ages of them. It is necessary to do periodic quality controls of equipments and improve the skillfulness of sonographers to reduce error rates between real treatment areas and the images of them.

Recommendations on the Direction of Radiology Practice Operation through the Evaluation of Practice Satisfaction before and after COVID-19 (COVID-19 전·후 임상 실습생의 만족도 평가를 통한 방사선학과 실습 운영 방향에 대한 제언)

  • Hyeon-Jin, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.985-993
    • /
    • 2022
  • This study was conducted to compare and evaluate the expectations and satisfaction of clinical practice for students who conducted practice at clinical practice institutions of various sizes before and after COVID-19, and to suggest future clinical practice guidance methods and operation directions. There was a significant difference in the evaluation of satisfaction with practice before and after COVID-19, especially after the evaluation of satisfaction with practice guidance, practice environment, and practice time. As a result of analyzing the decisive influencing factors related to practice satisfaction, students who conducted practice at university hospitals highly evaluated the institutional environmental factors, and students who conducted practice at small and medium-sized hospitals showed high satisfaction in participation-oriented practice. Therefore, it is thought that practice that utilizes the strengths and weaknesses of university hospitals and small and medium-sized hospitals will be more effective than clinical practice that relies only on university hospitals. However, in order to diversify the training institution to small and medium-sized hospitals, it is necessary to create a manual on standardized training courses, training methods, and evaluation methods suitable for the training goals and curriculum, and provide them to the institution. In addition, if it is operated through sufficient exchange of opinions and consultation with institutions, schools will be able to obtain opportunities to cultivate practical talents, and small and medium-sized hospitals with difficulties in expanding manpower will be able to secure excellent human resources first.

A Study on the Learning Effect and Satisfaction of Practical Classes for Students Majoring in Radiology in a Non-face-to-face Class Environment (방사선학 전공 학생의 비대면 전공 실습 수업에 대한 학습효과와 만족도에 관한 고찰)

  • Sung-Jin, Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.995-1006
    • /
    • 2022
  • The purpose of this study was to investigate the current status of practical course operation in a non-face-to-face online environment, learning effects, and students' experiences and perceptions for radiology major students using a survey. The questionnaire consisted of a total of 34 items in 5 areas: general characteristics of subjects, current learning participation in non-face-to-face environments, learning satisfaction, learning outcomes, improvement and requirements. For the analysis of the questionnaire responses, frequency analysis was performed on the response frequency, ratio, and scale for each item. Based on the general characteristics of the survey respondents, cross-analysis was performed using the chi-square test for participation in non-face-to-face learning, learning performance, and learning satisfaction. implemented. Improvements and requirements were qualitatively analyzed for the repetition frequency of words with the same meaning. Through the results of analyzing the responses of a total of 397 questionnaires, the direction of design and development of practical classes in a non-face-to-face environment in the future and basic information and implications for efficient operation were confirmed. Based on this, it is necessary to continue to think and make efforts for the efficient operation of non-face-to-face practice classes in the post-corona era.

A Comparative Study of Branching Ratio of 167Yb Radioactive Isotope from Gamma-ray Spectrum Produced by 169Tm(p,3n)167Yb Reaction with 100-MeV Proton Beam (100-MeV 양성자 빔을 이용하여 169Tm(p,3n)167Yb 반응에 의해 생성된 167Yb 방사성동위원소에서 방출되는 감마선 스펙트럼 비교 연구)

  • Sam-Yol, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.953-960
    • /
    • 2022
  • The measurement of branching ratio of 167Yb radioactive isotopes from gamma-ray spectrum of 169Tm(p,3n)167Yb reaction were performed by using a 100-MeV proton linear accelerator of the Korea Multi-purpose Accelerator Complex (KOMAC). The 167Yb isotope has a half-life of 17.5 minutes and decays to 169Tm. The gamma rays generated from the 167Yb isotope were measured using an HPGe detector gamma ray spectroscopy system. The energy calibration of the detector and the efficiency measurement of the detector were determined using a standard source. The gamma rays of known main energy (62.9, 106.2, 113.3, 143.5 and 176.3 keV) were measured. On the other hand, information about the intensity of the generated gamma rays is very inaccurate. Therefore, in this study, the decay strength of the main gamma rays was accurately measured. Overall, it was different from the previously known results, and in particular, it was found that the intensity of the main decay gamma ray, such as the 113.3 and 106.2 keV gamma ray, was overestimated, and it was found that the gamma ray, such as 62.9, 116.7 and 143.5 keV was underestimated. The present results are considered to be important information in the fields of nuclear fusion, astrophysics and nuclear physics in the future.

Efficacy Study of Osteradionecrosis Using Fibrin and SDF-1 (피브린과 SDF-1을 사용한 방사성뼈괴사의 효용성연구)

  • Hong-Moon, Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.799-805
    • /
    • 2022
  • Radiation therapy of human tissues, including bone tissue, is accompanied by side effects on normal tissues. It has a more lethal effect on stem cells, which play an essential role in tissue regeneration, including the basal cells constituting the tissue. In this study, the mouse parietal model, which implemented an artificial osteoradionecrosis model on the parietal region of the mouse, was artificially defected and then the bone regeneration was tested. In order to overcome the implemented osteoradionecrosis, a fibrin scaffold, widely used as a biomaterial, and stromal cell-derived factor-1 (SDF-1), which is used as a long-term treatment for damaged, were mixed to verify the osteoradionecrosis regeneration effect on the parietal of mouse. In order to expect a synergistic effect in the fibrin scaffolds, a fibrin scaffolds was prepared after maintaining the concentration of SDF-1 (1 ㎍/ml) in the fibrinogen solution. In this study, after artificially creating a osteoradionecrosis model in the parietal region of mouse, fibrin scaffolds were incorporated to analyze the effect of bone regeneration within 4 weeks, the initial stage of bone regeneration. In conclusion, the combined use of these two substances did not show a dramatic regenerative effect in inducing the regeneration of osteoradionecrosis in the parietal region of mouse. However, positive results were obtained that can be maintain the bone regeneration effect environment at the initial stage. Therefore, the combined use of the fibrin scaffold and SDF-1 is considered to be a suitable candidate for the effect of overcoming osteoradionecrosis.