• Title/Summary/Keyword: radiographic measurements

Search Result 130, Processing Time 0.025 seconds

Short-term Results of Medial Displacement Calcaneal Osteotomy for Flexible Flatfoot (유연성 편평족에 대한 내측 전위 종골 절골술의 단기 추시 결과)

  • Park, Jong-Ho;Moon, Jeong-Seok;Lee, Woo-Chun;Bae, Woo-Han;Seo, Jeong-Gook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.113-117
    • /
    • 2009
  • Purpose: To evaluate the short-term results of medial displacement calcaneal osteotomy without flexor digitorum longus transfer for flexible flatfoot deformity. Materials and Methods: Twenty four patients (25 feet) who had undergone medial displacement calcaneal osteotomy without flexor digitorum longus transfer for flexible flatfoot between July 2004 and May 2007 were included. The mean age was 43.6 years (16~78 years). The mean follow-up was 26 months (14~50 months). Clinical outcomes were assessed using American Orthopaedic Foot and Ankle Society (AOFAS) score and visual analogue scale (VAS). Six radiographic parameters were measured from weightbearing radiographs to assess the difference between preoperative and postoperative radiographs. Results: The mean AOFAS score improved from 57.9 points preoperatively to 89.2 points at latest follow-up (p=0.000). The mean VAS improved from 62 points preoperatively to 23 points at latest follow-up (p=0.000). The mean talonavicular coverage angle on anteroposterior (AP) view changed from 20.2 degrees to 16.0 degrees (p=0.002). The mean calcaneal pitch angle on lateral view changed from 12.6 degrees preoperatively to 14.5 degrees at latest follow-up (p=0.001). Regarding these radiographic parameters, the difference between interobserver measurements was larger than that between pre- and post-operative measurements. The calcaneus was transferred medially by average 11.8 mm (p=0.003), which was 27.9% of the width of calcaneal tuberosity (p=0.000). The mean talo-first metatarsal angle on AP and lateral views, and navicular height on lateral view were not significantly changed. Conclusion: Medial displacement calcaneal osteotomy without flexor digitorum longus transfer for flexible flatfoot could lead to improve the clinical outcomes, although the restoration of medial longitudinal arch was not clinically significant.

  • PDF

Quantification of Experimentally Induced-Pleural Effusion in Beagle Dogs: Radiography versus CT and Ultrasonography (비글견에서 실험적으로 유발한 흉수의 정량 평가: 방사선, 컴퓨터단층촬영 및 초음파 검사 비교)

  • Lee, Ki-Ja;O, I-Se;Jeong, Seong-Mok;Lee, Hee-Chun;Park, Seong-Jun;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.25 no.2
    • /
    • pp.96-101
    • /
    • 2008
  • This study was performed to quantify the pleural effusion in radiography, ultrasonography and computed tomography(CT) and to evaluate and compare the usefulness of these methods. Normal saline of 10 ml/kg was infused into the pleural space until a final loading volume of 60 ml/kg body weight was reached in six Beagle dogs. The radiographic examination was performed for the detection and quantification of pleural effusion. On the ultrasonographic study, the maximum perpendicular distance was measured between the surface of the lung and the thoracic wall to evaluate pleural effusion. On the CT image, pleural effusion was evaluated as the perpendicular distance to the thoracic surface in the maximum pleural effusion volume on any transverse images with soft tissue window. Statistical analysis was performed using linear regression test. The volume of pleural effusion and measurements of radiography and ultrasonography had no statistical relationship. However, a significant correlation was identified between the volume of pleural effusion and the depth at right ($r^2=0.715$), left ($r^2=0.745$), and mean right and left depth ($r^2=0.844$) on the CT images. All of the thoracic radiographs, ultrasonography, and CT are useful in recognition of pleural effusion. In quantification of pleural effusion, the CT measurement method is superior to radiographic and ultrasonographic measurements.

Alveolar ridge preservation with an open-healing approach using single-layer or double-layer coverage with collagen membranes

  • Choi, Ho-Keun;Cho, Hag-Yeon;Lee, Sung-Jo;Cho, In-Woo;Shin, Hyun-Seung;Koo, Ki-Tae;Lim, Hyun-Chang;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.6
    • /
    • pp.372-380
    • /
    • 2017
  • Purpose: The aim of this prospective pilot study was to compare alveolar ridge preservation (ARP) procedures with open-healing approach using a single-layer and a double-layer coverage with collagen membranes using radiographic and clinical analyses. Methods: Eleven molars from 9 healthy patients requiring extraction of the maxillary or mandibular posterior teeth were included and allocated into 2 groups. After tooth extraction, deproteinized bovine bone mineral mixed with 10% collagen was grafted into the socket and covered either with a double-layer of resorbable non-cross-linked collagen membranes (DL group, n=6) or with a single-layer (SL group, n=5). Primary closure was not obtained. Cone-beam computed tomography images were taken immediately after the ARP procedure and after a healing period of 4 months before implant placement. Radiographic measurements were made of the width and height changes of the alveolar ridge. Results: All sites healed without any complications, and dental implants were placed at all operated sites with acceptable initial stability. The measurements showed that the reductions in width at the level 1 mm apical from the alveolar crest (including the bone graft) were $-1.7{\pm}0.5mm$ in the SL group and $-1.8{\pm}0.4mm$ in the DL group, and the horizontal changes in the other areas were also similar in the DL and SL groups. The reductions in height were also comparable between groups. Conclusions: Within the limitations of this study, single-layer and double-layer coverage with collagen membranes after ARP failed to show substantial differences in the preservation of horizontal or vertical dimensions or in clinical healing. Thus, both approaches seem to be suitable for open-healing ridge preservation procedures.

A study on the correlations between facial biotype, submentovertex cephalometric measurements and surface EMG activity in patients with facial asymmetry (안면 비대칭 환자의 수직 안모 유형과 이하두정 두부방사선 규격사진 계측치 및 표면 근전도의 상관성에 대한 연구)

  • Kim, Seong-Soo;Lee, Nam-Ki;Cha, Bong-Kuen
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.218-227
    • /
    • 2006
  • Although the submentovertex radiograph and surface EMG are not often used due to the difficulty of interpretation, they are accepted as useful diagnostic and analytic aids for skeletal asymmetry. There have been reports which state that they were also useful for the evaluation of vertical skeletal relations. The purpose of this study was to evaluate the correlations between EMG data, measurements from submentovertex radiographs, facial types and facial asymmetry following examination of 60 asymmetric patients. The radiographic corpus length were greater in the nonaffected sides (p<0.001), gonion to interspinosum axis were greater in the affected sides and the mandibular condyle and gonion were located more anteriorly in the non-affected sides than in the affected sides but not significant (p=0.07). The activity of the anterior temporal muscle in rest position was higher in the affected sides than in the non-affected sides (p<0.01). The activity of the masseter muscle at maximum clenching was found to be nonsignificant but it was higher in the affected sides than in the non-affected sides (p=0.09). There was positive correlation between facial index and the intercondylar axes angle (p<0.01). There was positive correlation between masseter muscle activity in maximum occlusion and facial index in the affected and non-affected sides (p<0.05). The results demonstrate that the submentovertex radiograph and EMG can provide useful information for the evaluation of horizontal and vertical skeletal relations.

Construction and Performance Evaluation of Digital Radiographic System (이동형 디지털 X선 촬영장치의 구축 및 성능평가)

  • Cho, Hyo-Min;Nam, So-Ra;Lee, Chang-Lae;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.144-148
    • /
    • 2007
  • Current digital radiography systems are rapidly glowing in clinical applications. The purpose of this study was to evaluate the characteristics of a mobile digital radiographic system. The performance of the mobile DR system was evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on a LISTEM Mobix-1000 generator and a Teleoptic PRA Alpha-R4000 detector. Imaging characteristics were measured for these two systems using the IEC-61267 defined RQA5 (kVp: 74, additional filtration: 21 mmAl) radiographic condition. The MTF at 10% was measured as 2.4 cycles/mm and the DQE(0) values for radiation exposure 0.19, 0.5, and 1.3 mR were measured as 54%, 55%, and 76%, respectively. The NPS curves gradually decreased at high spatial frequencies. This high DQE at low frequencies, may be useful for low frequency information. The results suggested that mobile DR system could be integrated with emergency ambulance system in teleradiologic imaging applications.

  • PDF

Sex determination by radiographic localization of the inferior alveolar canal using cone-beam computed tomography in an Egyptian population

  • Mousa, Arwa;El Dessouky, Sahar;El Beshlawy, Dina
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.117-124
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate possible differences in the location of the inferior alveolar canal in male and female Egyptians. Materials and Methods: This cross-sectional retrospective study involved the evaluation of 210 CBCT scans of Egyptian individuals (18-70 years old). The inferior alveolar canal was localized by measuring 8 linear dimensions: 2 for the vertical localization of the mental foramen (superior and inferior to the mental foramen), 4 at the first molar bifurcation for the vertical and horizontal localization of the inferior alveolar canal (superior, inferior, buccal, and lingual to the inferior alveolar canal), and 2 for the horizontal localization of the mandibular foramen (anterior and posterior to the mandibular foramen). The measurements were statistically analyzed via comparative analysis, stepwise logistic regression, and receiver operating characteristic (ROC) curve analysis. Results: Six of the 8 measured distances differed to a statistically significant extent between the sexes. Regression analysis suggested a logistic function with a concordance index of 84%. The diagnostic accuracy capabilities of the linear measurements as sex predictors were calculated using ROC analysis, and the 6 best predictors for sex determination were selected and ranked from highest to lowest predictive power. Moreover, combining these 6 predictors increased the predictive power to 84%. Conclusion: The location of the inferior alveolar canal in the Egyptian population varies significantly by sex; accordingly, this anatomic landmark could be used as a reliable indicator of sexual dimorphism.

Usefulness of 3-Dimensional Body Surface Scanning in the Evaluation of Patients with Pectus Carinatum

  • Song, Seung Hwan;Kim, Chong Hoon;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.301-305
    • /
    • 2020
  • Background: Radiographic modalities have been commonly used to evaluate pectus carinatum (PC), and compressive orthotic bracing is the most widely accepted treatment method. The aim of this study was to determine the efficacy of 3-dimensional (3D) body surface scanning as an alternative modality for the evaluation of PC. Methods: The medical records of 63 patients with PC who were treated with compressive orthotic bracing therapy between July 2017 and February 2019 were retrospectively analyzed. Using both 2-view chest radiography (posteroanterior and lateral view) and 3D body scanning, the height of maximal protrusion of the chest wall was measured both before and after 2 weeks of bracing therapy. The difference between the pre- and post-treatment measurements was calculated for both modalities, and these differences were compared and analyzed. Results: Based on the comparison between the pre- and post-treatment radiographs, bracing therapy produced favorable outcomes in all patients (p<0.001). The measurements obtained via 3D scanning were strongly correlated with those obtained via chest radiography (r=0.60). Conclusion: Based on the findings of this study, 3D body surface scanning appears to be an effective, radiation-free, and simple method for the post-treatment follow-up evaluation of PC, and thus can be considered an alternative to radiography.

Is the panoramic mandibular index useful for bone quality evaluation?

  • Kwon, Ah-Young;Huh, Kyung-Hoe;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.87-92
    • /
    • 2017
  • Purpose: The aim of this study was to determine whether the panoramic mandibular index (PMI) is useful for assessing bone mineral density. We also analyzed the potential correlations between PMI parameters and patient age. Materials and Methods: Four observers measured the PMI of both sides of the mental foramen using a picture archiving and communication system and images in the Digital Imaging and Communications in Medicine format. They studied 300 panoramic radiographic images of patients belonging to the following age groups: 40-49 years, 50-59 years, 60-69 years, 70-79 years, and 80-89 years. The observers were allowed to zoom in or out and to adjust the contrast of the images. Further, they were instructed to record the reasons for any measurements that could not be made. Then, we conducted a reliability analysis of the measured PMI and assessed the correlations between different patient age groups and the 3 parameters used for determining the PMI from the available data. Results: Among the 600 data items collected, 23 items were considered unmeasurable by at least 1 observer for the following 4 reasons: postoperative state, lesion, unidentified mental foramen, and alveolar bone loss. The intraobserver reproducibility of the measurable data was 0.611-0.752. The mandibular cortical width (MCW) decreased significantly as patient age increased. Conclusion: PMI had limited usability when the margin of the mental foramen was not clear. In contrast, MCW, a parameter used for determining the PMI, had fewer drawbacks than the PMI with respect to bone mineral density measurements and exhibited a significant correlation with patient age.

Dosimetric Characteristic of Digital CCD Video Camera for Radiation Therapy

  • Young Woo. Vahc;Kim, Tae Hong.;Won Kyun. Chung;Ohyun Kwon;Park, Kyung Ran.;Lee, Yong Ha.
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.147-155
    • /
    • 2000
  • Patient dose verification is one of the most important parts in quality assurance of the treatment delivery for radiation therapy. The dose distributions may be meaningfully improved by modulating two dimensional intensity profile of the individual high energy radiation beams In this study, a new method is presented for the pre-treatment dosimetric verification of these two dimensional distributions of beam intensity by means of a charge coupled device video camera-based fluoroscopic device (henceforth called as CCD-VCFD) as a radiation detecter with a custom-made software for dose calculation from fluorescence signals. This system of dosimeter (CCD-VCFD) could reproduce three dimensional (3D) relative dose distribution from the digitized fluoroscopic signals for small (1.0$\times$1.0 cm$^2$ square, ø 1.0 cm circular ) and large (30$\times$30cm$^2$) field sizes used in intensity modulated radiation therapy (IMRT). For the small beam sizes of photon and electron, the calculations are performed In absolute beam fluence profiles which are usually used for calculation of the patient dose distribution. The good linearity with respect to the absorbed dose, independence of dose rate, and three dimensional profiles of small beams using the CCD-VCFD were demonstrated by relative measurements in high energy Photon (15 MV) and electron (9 MeV) beams. These measurements of beam profiles with CCD-VCFD show good agreement with those with other dosimeters such as utramicro-cylindrical (UC) ionization chamber and radiographic film. The study of the radiation dosimetric technique using CCD-VCFD may provide a fast and accurate pre-treatment verification tool for the small beam used in stereotactic radiosurgery (SRS) and can be used for verification of dose distribution from dynamic multi-leaf collimation system (DMLC).

  • PDF

CLINICAL EVALUATION OF CORALLINE BASED POROUS HYDROXYAPATITE AND CORALLINE BASED CALCIUM CARBONATE IN HUMAN INTRABONY PERIODONTAL LESIONS (Coralline Based Porous Hydroxyapatite와 Coralline Based Calcium Carbonate의 이식후 치조골내결손부에 대한 임상적 평가)

  • Shim, Jung-Min;Son, Seong-Heui;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.120-130
    • /
    • 1994
  • The purpose of the present investigation was to compare the effectiveness of porous hydroxyapatite (PHA) and coralline based porous calcium carbonate(PCC) as implant materials in human periodontal osseous defects. 10 adult patients having periodontitis and 2 similar angular osseous defects ${\ge}$5mm as verified by radiographic analysis and clinical probing depth ${\ge}$4mm were selected. The measurements were recorded just before surgery and after 6 month. Clinical parameters used in this study included gingival recession, pocket depth, probing attachment level, Sulcus Bleeding Index, Plaque Index, tooth mobility and bone defect depth measurements. After initial therapy, patients were treated with mucoperiosteal flap surgery. The contralateral bony defects in each patient randomly assigned to either bone graft material, one with PHA(Interpore 200) and the other with coralline based calcium carbonate(Biocoral). After 6 month both groups showed statistically significant reduction of pocket depth, Sulcus Bleeding Index, Plaque Index and significant improvement in probing attachment level. No statistically significant differences were found between the groups. There were 3.0mm or 68% of bone repair with PHA and 3.1mm, 61% with PCC. These values were likewise not significantly different. The data and clinical impression strongly suggest that both PHA and PCC are alloplastic implants with clinically apparent acceptance by the soft and hard tissue and that they can be used as bone graft materials successfully.

  • PDF