• Title/Summary/Keyword: radioactive ray

Search Result 226, Processing Time 0.028 seconds

A Study on the Radiation Source Effect to the Radiation Shielding Analysis for a Spent-Fuel Cask Design with Burnup-Credit (연소도이득효과를 적용한 사용후핵연료 수송용기의 방사선원별 차폐영향 분석)

  • Kim, Kyung-O;Kim, Soon-Young;Ko, Jae-Hoon;Lee, Gang-Ug;Kim, Tae-Man;Yoon, Jeong-Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.73-80
    • /
    • 2011
  • The radiation shielding analysis for a Burnup-credit (BUC) cask designed under the management of Korea Radioactive Waste Management Corporation (KRMC) was performed to examine the contribution of each radiation source affecting dose rate distribution around the cask. Various radiation sources, which contain neutron and gamma-ray sources placed in active fuel region and the activation source, and imaginary nuclear fuel were all considered in the MCNP calculation model to realistically simulate the actual situations. It was found that the maximum external and surface dose rates of the spent fuel cask were satisfied with the domestic standards both in normal and accident conditions. In normal condition, the radiation dose rate distribution around the cask was mainly influenced by activation source ($^{60}Co$ radioisotope); in another case, the neutron emitted in active fuel region contributed about 90% to external dose rate at 1m distance from side surface of the cask. Besides, the contribution level of activation source was dramatically increased to the dose rates in top and bottom regions of the cask. From this study, it was recognized that the detailed investigation on the radiation sources should be performed conservatively and accurately in the process of radiation shielding analysis for a BUC cask.

A New Composition of Nanosized Silica-Silver for Control of Various Plant Diseases

  • Park Hae-Jun;Kim Sung-Ho;Kim Hwa-Jung;Choi Seong-Ho
    • The Plant Pathology Journal
    • /
    • v.22 no.3
    • /
    • pp.295-302
    • /
    • 2006
  • The present study addressed the efficacy of nanosized silica-silver for controlling plant pathogenic microorganisms. The nanosized silica-silver consisted of nano-silver combined with silica molecules and water soluble polymer, prepared by exposing a solution including silver salt, silicate and water soluble polymer to radioactive rays. The nanosized silica-silver showed antifungal activity against the tested phytopathogenic fungi at 3.0 ppm with varied degrees. In contrast, a number of beneficial bacteria or plant pathogenic bacteria were not significantly affected at 10 ppm level but completely inhibited by 100 ppm of nanosized silicasilver. Among the tested plant pathogenic fungi, the new product effectively controlled powdery mildews of pumpkin at 0.3 ppm in both field and greenhouse tests. The pathogens disappeared from the infected leaves 3 days after spray and the plants remained healthy thereafter. Our results suggested that the product developed in this study was effective in controlling various plant fungal diseases.

방사성 동위원소를 이용한 문화재의 과학적보존 -고고유품 및 미술품의 조사감식법-

  • 김유선
    • Nuclear Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.229-240
    • /
    • 1972
  • Radioisotopes and their related techniques have recently been applied for scientific conservation works of cultural property and resulted many excellent findings or conservation data which could never be achieved by means of other techniques. Radiocarbon dating have widely been applied for dating the antique of organic origin, whereas the determination of radioactive contents in metal, ceramics, environmental soil, and classical objects could be able to afford many useful informations on the age, genuiness, and archeological significances as it had been produced. Trace quantity of contents of each antique have successfully been analyzed by means of radioactivation analysis or radio active tracer techniques, which could afford important technical data and results for tile conservation of each object. Radiography have also been applied for detecting the internal defects of metal objects and furthermore $\beta$-and ${\gamma}$-ray radiography were proved to be effective for such thin material as textile, painting, and fibres. In this article the detailed principle and procedures of each technique were presented so that the society could be able to make efforts to familiarize all concerns with these modern trends of the conservation techniques of cultural property.

  • PDF

Teratogenic Effect of Carbamazepine (카바마제핀의 기형발생 효과)

  • Choi, Yeong-Tae;Cheon, Jin-Sook
    • Korean Journal of Biological Psychiatry
    • /
    • v.5 no.2
    • /
    • pp.283-287
    • /
    • 1998
  • The mother was 24 years old, primipara, and had been taking carbamazepine 400mg(serum concentration $5.0-8.5{\mu}g/ml$) during pregnancy without any clinical seizures. A male baby with physical malformation was delivered on week 39. The malformation is extradigit(polydactily) on X-ray of right foot and left mild hydronephrosis on ultrasonography and renal scan with radioactive material. We reported this rare case and reviewed related articles about teratogenic effect of carbamazepine, mechanism of action and prevention of teratogenesis.

  • PDF

A study for the changer of resistance and influence of the dioctylphthalate by irradiation on the polyvinyl chloride (폴리염화비닐에 방사선 조사시의 저항의 변화와 가소제의 영향)

  • 신종원;백용현
    • 전기의세계
    • /
    • v.30 no.10
    • /
    • pp.639-644
    • /
    • 1981
  • PVC is a kind of electric insulation polymer. But we get some deteriorations in electrical characteristics of the PVC, when it is used on the radioactive field. In order to find out the cause of the deterioration, we investigate the surface-resistance, volume-resistance, dielectric constant and dielectric loss angle of the soft and hard PVC which is irradiated by the Co$^{60}$ .gamma. radioactivity. From the experiment, we can conclude the followings 1. Radio-activity proof characteristic in the soft PVC is stronger than in the hard PVC. 2. The resistance of PVC which is irradiated by the radio-activity decrease exponentially. 3. The dielectric constant and the dielectric loss angle of PVC irradiated by Co$^{60}$ .gamma.ray reach maximum value in first few time.

  • PDF

A study on autonomous Cleaning Robot for Hot-cell Application (핫셀 적용을 위한 벽면주행 청소로봇에 관한 연구)

  • 한상현;김기호;박장진;장원석;이응혁
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.415-415
    • /
    • 2000
  • The functions of a mobile robot such as obstacle knowledge and collision avoidance for in-door cleaning are necessary features, as has been much studied in the field of industrial automatic guided vehicle or general mobile robot. A mobile robot, in order to avoid collision with obstacles, has to gather data with environment knowledge sensors and recognize environment and the shape of obstacles from the data. In the study, a wall-following algorithm was suggested as a autonomous moving algorithm in which a mobile robot can recognize obstacles in indoor like environment and do cleaning work in effect. The system suggested in the study is for cleaning of nuclear material dusts generated in the process of nuclear fuel manufacturing and decontamination of devices in disorder which is performed in M6 radioactive ray shield hot-cell in IMEF(Irradiated Material Examination Facility) in the Korea Atomic Energy Research Institute.

  • PDF

A Safety Assessment of Weld Defective Steel Bridges (강교량의 용접불량에 따른 안전도 분석)

  • Park, Seung-Bum;Bang, Myeung-Sug;Kim, Do-Gyeum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.2
    • /
    • pp.107-113
    • /
    • 1997
  • Nondesructive test and structural analysis have been conducted to assess the safety of weld defective steel bridges in service. In the nondestructive test, using the radioactive ray and ultrasonic, the defective welding patterns in the steel bridges are identified. A major defective welding pattern is identified as the lack of welding area due to the insufficient welding penetration. By considering the welding defect in the above, structural analysis is conducted to evaluate the influence of welding defect on the safety of steel bridges. The results indicate that, due to the insufficient welding penetration, the stress obtained in the analysis is over the allowable fatigue stress level, and its influence on safety of the bridges is significant.

  • PDF

Bleomycin Used for Esophageal and Lung Carcinoma: Clinical Two Cases Report (악성 종양에 대한 Bleomycin 사용 경험례: 식도 및 폐암의 2예)

  • Lee, Yang-Sam;Kwack, Moon-Sub;Kim, Se-Wha
    • Journal of Chest Surgery
    • /
    • v.3 no.2
    • /
    • pp.143-148
    • /
    • 1970
  • Bleomycin is known as a antibiotic agent for malignant tumors especially sguamous cell carcinoma. We have treated 2 cases of malignant tumors, each one esophageal and lung carcinoma with bleomycin, 630 mg and 510 mg respectively. In case of esophageal carcinoma. the subjective symptoms such as dysphagea and swallowing disturbance are temporally relieved, but the irregular filling defect is not significantly changed in esophagogram. In case of lung carcinoma, the atelectasis of right upper lobe on chest X-ray was slightly regressed in its size without effective improvement of subjective symptoms. However, following additional radioactive $^60{Co}$ irradiation therapy (5200r), marked regression of tumor density and aeration of right upper lobe was observed. But 2 weeks later of ceasatioil of irradiatio:J, atelectasis of right upper lobe was again developed. Fever, anorexia, headache and eruption were developed during the treatmeat with bleomycin in both cases but the sign or symptoms of hone marrow depression, renal or liver damage were not noted.

  • PDF

Physical Dosimetry in Radioactive Iodine Treatment in the Patients with Thyroid Cancer (갑상선암 환자에 대한 방사성옥소 치료시 물리적 선량 측정)

  • Kim, Myung-Seon;Jeong, Nae-In;Lee, Jai-Yong;Kim, Chong-Soon;Kim, Chong-Ho;Lee, Myung-Chul;Koh, Channg-Soon;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.124-132
    • /
    • 1994
  • Radioactive iodine has been widely used in patients with thyroid cancer combined with surgical treatment. However, due to individual variations in absorption and excretion and uptake by tumor tissue of radioactive iodine, there are differences in therapeutic effect and adverse effects even if the same doses are administrated. So this study compared the therapeutic effect and radiation hazard by measuring internal radiation dose. Of total 27 patients with well differentiated thyroid cancer who had been thyroidectomized, we administered radioactive iodine 100 mCi, 150 mCi, 200 mCi. According to BEL DOSIMETRY PROTO-COL, beta and gamma ray dose were estimated from a pelt of the logarithm of the percent of dose per liter of whole blood versus day, and percent dose retained versus day using somilogarithmic paper, respectively. 1) Physical dose to whole blood averaged $56.54{\pm}13.02$ rad in 100 mCi administered group, $76.83{\pm}19.97$ rad in 150 mCi administered group, $95.08{\pm}25.51$ rad in 200 mCi administered group and there has been a significant correlation among the groups. 2) Mean percent dose retained 48 hours later was 26.34%. 3) There was no significant correlation of physical dose between absence and presence of metastasis. 4) 17 of 19 patients who has been followed up with TSH and serum throglobulin, Thallium scan were successfully ablated by radioactive iodine. 5) Leukocyte, lymphocyte, neutrophil, platelet counts all deelined in 4.6 weeks and most of all were restored 3 months later. 6) There was no significant correlation between physical dosimetry and biologic dosimetry. Generally administered doses of radioactive iodine (100-200 mCi) to patients with thyroid cancer postoperatively had developed transient bone marrow suppression and minimal chromosomal aberration, but they were within safety dose to blood (200 rad). And there has been no significant differences in residual dose 48 hours later between Korean and western people.

  • PDF

Indoor Radon Levels and Effective Dose Estimation in Learning and Common Living Space of University (대학 내 학습공간과 공동 생활공간에 대한 실내 라돈 농도 측정과 유효선량 산출)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.329-334
    • /
    • 2018
  • Radon which is natural component of air is a colorless and odorless radioactive gas. Radon exposure can also occur from some building materials if they are made from radon-containing substances by breathing. In this study, The radiation dose of radon concentration was detected at 8 buildings of the A university during 3-month from June. 2017 to August. 2017. We detected indoor radon exposure at 8 building of the university and estimated annual effective dose. The radon concentration of Hall G and Hall F of the A university represented 81 and $14Bq/m^3$ respectively and average indoor radon concentration represented $41.63Bq/m^3$. Average effective dose was estimated 0.40 mSv/y, maximum effective dose was 0.78 mSv/y and minimum effective dose was 0.13 mSv/y respectively. University is the place that students spend the almost whole time. We suggest ventilation and appropriate management of a building, which could reduce the natural radiation exposure by radon concentration.