• Title/Summary/Keyword: radiation sphere

Search Result 86, Processing Time 0.025 seconds

IRAS OBSERVATIONS OF DARK GLOBULES

  • Lee, H.M.;Hong, S.S.;Kwon, S.M.
    • Journal of The Korean Astronomical Society
    • /
    • v.24 no.1
    • /
    • pp.55-70
    • /
    • 1991
  • Infrared emission maps are constructed at 12.5, 25, 60, and $100{\mu}m$ for dark globules B5, B34, B133, B134, B361, L134 and L1523 by using Infrared Astronomical Satellite data base. These clouds are selected on the basis of their appearance in Palomar print as dark obscuring objects with angular sizes in the range of 3 to 30 arcminutes. The short wavelength(12.5 and $25{\mu}m$) maps show the embedded infrared sources. We found many such sources only in B5, B361 and B34 regions, Diffuse component at 12.5 and $25{\mu}m$, possibly arising from the stochastically heated very small dust grains(a < $0.01{\mu}m$) by interstellar radiation field, is found in B361 and L1523 regions. Such emission is characterized by the limb brightening, and it is confirmed in L1523 and in B361. Infrared emissions at the long wavelengths(60 and $100{\mu}m$) are due to colder dusts with temperature less than 20 K. The distribution of color index determined by the ratio 60 to $100{\mu}m$ intensities shows monotonic decrease of dust temperature toward the center. The black body temperature determined from these ratios is found to lie between 16 and 23 K. Such temperature is possible for small(i.e., $a\;{\lesssim}\;0.01{\mu}m$) graphite grains if the grains are mainly heated by interstellar radiation field. Thus IRAS 100 and $60{\mu}m$ emissions are arising mainly from small grains in the colud. The distribution of such dust grains implied from the emissivity distributions at 100 and $60{\mu}m$ resembles that of isothermal sphere. This contrasts to earlier findings of much steeper distribution of dusts contributing visible extinction. These dust grains are mainly larger ones(i.e., $a{\simeq}0.1{\mu}m$). Therefore we conclude that the average grain size increase, toward the cloud center.

  • PDF

Determination of Microdosimetric Quantities of Several Neutron Calibration Fields at KAERI

  • Kim, B.H.;Kim, J.S.;Kim, J.L.;Chang, S.Y.;Cho, G.;McDonald, J.C.
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.327-335
    • /
    • 2003
  • The commercially available neutron survey meter, the REM500, which uses a tissue equivalent proportional counter (TEPC) and the self-constructed TEPC were used to determine the microdosimetric quantities of several neutron calibration fields at Korea Atomic Energy Research Institute (KAERI). Microdosimetric spectra, absorbed dose, dose equivalent as well as quality factor were derived and compared with several neutron fields which were produced by using the shadow objects to make neutron scattered and being used as a kind of realistic neutron calibration fields at KAERI. The response of REM500 as a function of mean energy was evaluated with these neutron fields using the counts measured and the predetermined reference value. The response of the self-made TEPC and the REM500 was compared using one of the neutron calibration filelds of a $^{252}Cf$ source. The reference quantities of scattered neutron calibration fields were determined using a Bonner Sphere (BS). The value of frequency-mean lineal energy, dose-mean lineal energy and quality factor of two $^{252}Cf$ sources (unmoderated and $D_2O$ moderated) were determined to check the differences in the reference neutron fields between KAERI and Pacific Northwest National Laboratory (PNNL, USA) and the results were in good agreement within 1%. It means that there is no big difference in dosimetric quantifies of neutron calibration fields of two laboratories.

Numerical Study on Wave-induced Motion of Offshore Structures Using Cartesian-grid based Flow Simulation Method (직교 격자계 기반 유동해석기법을 이용한 파랑 중 해양구조물의 운동 해석)

  • Nam, Bo Woo;Kim, Yonghwan;Yang, Kyung Kyu;Hong, Sa Young;Sung, Hong Gun
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.7-13
    • /
    • 2012
  • This paper presents a numerical study of the wave loads acting on offshore structures using a Cartesian-grid-based flow simulation method. Finite volume discretization with a volume-of-fluid (VOF) method is adopted to solve two-phase Navier-Stokes equations. Among the many variations of the VOF method, the CICSAM scheme is applied. The body boundary conditions are satisfied using a porosity function, and wave generation is carried out by using transient (wave or damping) zone approaches. In order to validate the present numerical method, three different basic offshore structures, including a sphere, Pinkster barge, and Wigley model, are numerically investigated. First, diffraction and radiation problems are solved using the present numerical method. The wave exciting and drift forces from the diffraction problems are compared with potential-based solutions. The added mass and wave damping forces from the radiation problems are also compared with the potential results. Next, the wave-induced motion responses of the structures are calculated and compared with the existing experimental data. The comparison results are fairly good, showing the validity of the present numerical method.

On-orbit test simulation for field angle dependent response measurement of the Amon-Ra energy channel instrument

  • Seong, Sehyun;Kim, Sug-Whan;Ryu, Dongok;Hong, Jinsuk;Lockwood, Mike
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.211.1-211.1
    • /
    • 2012
  • The on-orbit test simulation for predicting the instrument directional responsivity was conducted by the Monte Carlo based integrated ray tracing (IRT) computation technique and analytic flux-to-signal conversion algorithms. For the on-orbit test simulation, the Sun model consists of the Lambertian scattering sphere and emitting spheroid rays, the Amon-Ra instrument is a two-channel including a broadband scanning radiometer (energy channel) and an imager with ${\pm}2^{\circ}$ FOV (visible channel). The solar radiation produced by the Sun model is directed to the instrument viewing port and traced through the dual channel optical train. The instrument model is rotated on its rotation axis and this gives a slow scan of the Sun model over the full field of view. The direction of the incident lights are fed with scanned images obtained from the visible channel instrument. The instrument responsivity was computed by the ratio of the incident radiation input to the instrument output. In the radiometric simulation, especially, measured BRDF of the 3D CPC was used for scattering effects on radiometry. With diamond turned 3D CPC inner surface, the anisotropic surface scattering model from the measured data was applied to ray tracing computation. The technical details of the on-orbit test simulation are presented together with field-of-view calibration plan.

  • PDF

Acceleration of the Multi-Level Fast Multipole Algorithm using Double Interpolation Technique (이중 보간 기법을 이용한 MLFMA 가속기법)

  • Yun, Dal-Jae;Kim, Hyung-Ju;Lee, Jae-In;Yang, Seong-Jun;Yang, Woo-Yong;Bae, Jun-Woo;Myung, Noh-Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.311-319
    • /
    • 2019
  • This paper proposes an acceleration of the multi-level fast multipole algorithm(MLFMA) by using a double interpolation method. The MLFMA has been primarily used to conduct scattering analysis of electrically large targets, e.g. stealth aircraft. In the MLFMA, radiation functions of each basis functions are first precomputed, and then aggregated. After transfer calculations for the aggregations, each interaction is disaggregated, and then received in the testing function. The key idea of the proposed method is to decrease the sampling rates of the radiation and receiving functions. The computational complexity of the unit sphere integration in terms of the testing functions is thus highly alleviated. The remaining insufficient sampling rate is then complemented by using additional interpolation. We demonstrate the performance of the proposed method through radar cross-section(RCS) calculations for realistic aircraft.

Monte Carlo approach for calculation of mass energy absorption coefficients of some amino acids

  • Bozkurt, Ahmet;Sengul, Aycan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3044-3050
    • /
    • 2021
  • This study offers a Monte Carlo alternative for computing mass energy absorption coefficients of any material through calculation of photon energy deposited per mass of the sample and the energy flux obtained inside a sample volume. This approach is applied in this study to evaluate mass energy absorption coefficients of some amino acids found in human body at twenty-eight different photon energies between 10 keV and 20 MeV. The simulations involved a pencil beam source modeled to emit a parallel beam of mono-energetic photons toward a 1 mean free path thick sample of rectangular parallelepiped geometry. All the components in the problem geometry were surrounded by a 100 cm vacuum sphere to avoid any interactions in materials other than the absorber itself. The results computed using the Monte Carlo radiation transport packages MCNP6.2 and GAMOS5.1 were checked against the theoretical values available from the tables of XMUDAT database. These comparisons indicate very good agreement and support the conclusion that Monte Carlo technique utilized in this fashion may be used as a computational tool for determining the mass energy absorption coefficients of any material whose data are not available in the literature.

A Monte Carlo Study of the Diffusion Process of Thomson-Scattered Line Radiation in Phase Space

  • Hyeon Yong Choe;Hee-Won Lee
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.1
    • /
    • pp.23-33
    • /
    • 2023
  • We investigate the diffusion process of Thomson-scattered line photons in both real space and frequency space through a Monte Carlo approach. The emission source is assumed to be monochromatic and point-like embedded at the center of a free electron region in the form of a sphere and a slab. In the case of a spherical region, the line profiles emergent at a location of Thomson optical depth τTh from the source exhibit the full width of the half maximum σλ ≃ τ1.5Th. In the slab case, we focus on the polarization behavior where the polarization direction flips from the normal direction of the slab to the parallel as the slab optical depth τTh increases from τTh ≪ 1 to τTh ≫ 1. We propose that the polarization flip to the parallel direction to the slab surface in optically thick slabs is attributed to the robustness of the Stokes parameter Q along the vertical axis with respect to the observer's line of sight whereas randomization dominates the remaining region as τTh increases. A brief discussion on the importance of our study is presented.

Frameless Fractionated Stereotactic Radiaton Therapy in Recurrent Head & Neck Cancers (국소재발된 두경부종양의 무고정틀 정위적 분할방사선치료)

  • Kim In-Ah;Choi Ihl-Bhong;Jang Ji-Young;Kang Ki-Mun;Jho Seung-Ho;Kim Hyung-Tae;Lee Kyung-Jin;Choi Chang-Rak
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.156-163
    • /
    • 1998
  • Background & Objectives: Frameless fractionated stereotactic radiotherapy(FFSRT) is a modification of stereotactic radiosurgery(SRS) with radiobiologic advantage of fractionation without losing mechanical accuracy of SRS. Local recurrence of head and neck cancer at or near skull base benefit from reirradiation. Main barrier to successful palliation is dose limitation secondary to normal tissue tolerance. We try to evaluate the efficacy and safety of FFSRT as a new modality of reirradaton in these challenging patients. Materials & Methods: Seven patients with recurrent head & neck cancer involving at or near skull base received FFSRT from September 1995 to November 1997. Six patients with nasopharyngeal cancer had received induction chemotherapy and curative radiation therapy. One patient with maxillary sinus cancer had received total maxillectomy and postoperative radiation therapy as a initial treatment. Follow-up ranged from 11 to 32 months with median of 24 months. Three of 7 patients received hyperfractionated radiation therapy(1.1-1.2Gy/fraction, bid, total 19.8-24Gy) just before FFSRT. All patients received FFSRT(3-5Gy/fraction, total 15-30Gy/5-10fractions). Chemotherapy(cis-platin $100mg/m^2$) were given concurrently with FFSRT in four patients. Second course of FFSRT were given in 4 patients with progression or recurrence after initial FFSRT. Because IF(irregularity factor; ratio of surface area of target to the surface area of sphere with same volume as a target) is too big to use conventional stereotactic RT using multiple arc method for protection of radiation damage to critical normal tissue, all patients received FFSRT with conformal method using irregular static ports. Results: Five of 7 patients showed complete remission in follow-up CT &/or MRI. Three of these five patients who developed marginal, in-field, and out-field recurrences, respectively. Another one of complete responders has been dead of G-I bleeding without evidence of local recurrence. One partial responder who showed progressive disease 15 months after initial FFSRT has received additional FFSRT, and then he is well-being with symptomatic improvement. One minmal responder who showed progression of locoregional disease 9 months after $1^{st}$ FFSRT has received 2nd FFSRT, and then he is alive with stable disease. Five of 7 case had showed direct invasion to skull base and had complaint headache and various symptoms of cranial nerve involvement. Four of these five case showed improvement of neurologic symptoms after FFSRT. No significant neurologic complicaltion related to FFSRT was observed during follow-up periods. Tumor volumes were ranged from 3.9 to 50.7 cc and surface area ranged from 16.1 to $114.9cm^2$. IF ranged from 1.21 to 1.74. The average ratio of volume of prescription isodose shell to target volume was 1.02 that indicated the improvement of target coverage and dose distribution with FFSRT with conformal method compared to target coverage with FFSRT with multiple arc method. Conclusion: Our initial experience suggests that FFSRT with conformal method was relatively effective and safe modality in the treatment of recurrent head and neck cancer involving at or near skull base. Treatment benefit included good palliation of symptoms and reasonable radiographic response. However, more experience and additional follow-up are needed to better assess its ultimate role in treating these challenging patients.

  • PDF

The Study on the Effect of Target Volume in DQA based on MLC log file (MLC 로그 파일 기반 DQA에서 타깃 용적에 따른 영향 연구)

  • Shin, Dong Jin;Jung, Dong Min;Cho, Kang Chul;Kim, Ji Hoon;Yoon, Jong Won;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.53-59
    • /
    • 2020
  • Purpose: The purpose of this study is to compare and analyze the difference between the MLC log file-based software (Mobius) and the conventional phantom-ionization chamber (ArcCheck) dose verification method according to the change of target volume. Material and method: Radius 0.25cm, 0.5cm, 1cm, 2cm, 3cm, 4cm, 5cm, 6cm, 7cm, 8cm, 9cm, 10cm with a Sphere-shaped target Twelve plans were created and dose verification using Mobius and ArcCheck was conducted three times each. The irradiated data were compared and analyzed using the point dose error value and the gamma passing rate (3%/3mm) as evaluation indicators. Result: Mobius point dose error values were -9.87% at a radius of 0.25cm and -4.39% at 0.5cm, and the error value was within 3% at the remaining target volume. The gamma passing rate was 95% at a radius of 9cm and 93.9% at 10cm, and a passing rate of more than 95% was shown in the remaining target volume. In ArcCheck, the average error value of the point dose was about 2% in all target volumes. The gamma passing rate also showed a pass rate of 98% or more in all target volumes. Conclusion: For small targets with a radius of 0.5cm or less or a large target with a radius of 9cm or more, considering the uncertainty of DQA based on MLC log files, phantom-ionized DQA is used in complementary ways to include point dose, gamma index, DVH, and target coverage. It is believed that it is desirable to verify the dose delivery through a comprehensive analysis.

Dosimetric Evaluation of Static and Dynamic Intensity Modulated Radiation Treatment Planning and Delivery (세기조절방사선치료에서 조사방법이 빔 파라미터 및 선량에 미치는 영향에 대한 연구)

  • Kim Sung-Kyu;Kim Myung-Se;Yun Sang-Mo
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.114-122
    • /
    • 2006
  • The two commonly used methods in delivering intensity modulated radiation therapy (IMRT) plan are the dynamic (sliding window) and static (stop and shoot) mode. In this study, the two IMRI delivery techniques are compared by measuring point dose and dose distributions. Using treatment planning system, clinical target volume (CTV) was created as a sphere with various diameter (3 cm, 7 cm, 12 cm). Two IMRT plans were peformed to deliver 200 cGy to the CTV in dynamic and static mode. The two plans were delivered on a phantom and central point dose and dose distributions were measured. The central point dose differences between static and dynamic IMRT delivery were 0.2%, 0.2% and 0.4% when the diameter of CTV was 3 cm, 7 cm, and 12 cm, respectively. The differences In volume receiving 90% of the proscribed dose were 2.7%, 2.2%, and 2.9% for the diameter of CTV was 3 cm, 7 cm, and 12 cm, respectively. For lung cancer patients, the differences in central point dose were 0.2%, 0.2%, and 0.4% when the volume of CTV was 35.5 cc, 296.8 cc, and 903.5 cc, respectively. The differences in volume receiving 90% of the prescribed dose were 2.7%, 4.8%, and 9.1% when the volume of CTV was 35.5 cc, 296.8 cc, and 903.5 cc, respectively. In conclusion, it was possible to deliver IMRT plans using dynamic mode of MLC operation although the loaves are In motion during radiation delivery.

  • PDF