Browse > Article
http://dx.doi.org/10.1016/j.net.2021.04.004

Monte Carlo approach for calculation of mass energy absorption coefficients of some amino acids  

Bozkurt, Ahmet (Akdeniz University, Faculty of Engineering, Department of Biomedical Engineering)
Sengul, Aycan (Akdeniz University, Vocational School of Health Services, Medical Imaging Program)
Publication Information
Nuclear Engineering and Technology / v.53, no.9, 2021 , pp. 3044-3050 More about this Journal
Abstract
This study offers a Monte Carlo alternative for computing mass energy absorption coefficients of any material through calculation of photon energy deposited per mass of the sample and the energy flux obtained inside a sample volume. This approach is applied in this study to evaluate mass energy absorption coefficients of some amino acids found in human body at twenty-eight different photon energies between 10 keV and 20 MeV. The simulations involved a pencil beam source modeled to emit a parallel beam of mono-energetic photons toward a 1 mean free path thick sample of rectangular parallelepiped geometry. All the components in the problem geometry were surrounded by a 100 cm vacuum sphere to avoid any interactions in materials other than the absorber itself. The results computed using the Monte Carlo radiation transport packages MCNP6.2 and GAMOS5.1 were checked against the theoretical values available from the tables of XMUDAT database. These comparisons indicate very good agreement and support the conclusion that Monte Carlo technique utilized in this fashion may be used as a computational tool for determining the mass energy absorption coefficients of any material whose data are not available in the literature.
Keywords
Photons; Mass energy absorption coefficient; Monte Carlo simulations; Amino acids;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J.H. Hubbell, Review and history of photon cross section calculations, Phys. Med. Biol. 51 (13) (2006) R245-R262.   DOI
2 C.S. Sureka, C. Armpilia, Radiation Biology for Medical Physicists, CRC Press, 2017.
3 F.H. Attix, Introduction to Radiological Physics and Radiation Dosimetry, Wiley, 1986.
4 P.P. Pawar, G.K. Bichile, Studies on mass attenuation coefficient, effective atomic number and electron density of some amino acids in the energy range 0.122-1.330 MeV, Radiat. Phys. Chem. 92 (2013) 22-27.   DOI
5 D.K. Gaikwad, P.P. Pawar, T.P. Selvam, "Measurement of attenuation crosssections of some fatty acids in the energy range 122-1330 keV, Pramana - J. Phys. 87 (1) (2016) 1-12.   DOI
6 B.T. Tonguc, H. Arslan, M.S. Al-Buriahia, Studies on mass attenuation coefficients, effective atomic numbers and electron densities for some biomolecules, Radiat. Phys. Chem. 153 (2018) 86-91.   DOI
7 A. Sahin, A. Bozkurt, Monte Carlo Calculation of Mass Attenuation Coefficients of Some Biological Compounds 14 (2) (2019) 408-417.
8 J.H. Hubbell, Review of photon interaction cross section data in the medical and biological context, Phys. Med. Biol. 44 (1999) R1-R22.   DOI
9 N. Ekinci, N. Astam, Measurement of mass attenuation coefficients of biological materials by energy dispersive X-ray fluorescence spectrometry, Radiat. Meas. 42 (3) (2007) 428-430.   DOI
10 M.J. Berger, J.H. Hubbell, S.M. Seltzer, J. Chang, J.S. Coursey, R. Sukumar, D.S. Zucker, K. Olsen, XCOM: Photon Cross Section Database (version 1.5), National Institute of Standards and Technology, Gaithersburg, MD, 2010 [Online] Available: http://physics.nist.gov/xcom [2021, April 30].
11 B.M. Ladhaf, P.P. Pawar, Studies on mass energy-absorption coefficients and effective atomic energy-absorption cross sections for carbohydrates, Radiat. Phys. Chem. 109 (2015) 89-94.   DOI
12 B.O. Elbashir, M.G. Dong, M.I. Sayyed, S.A.M. Issa, K.A. Matori, M.H.M. Zaid, Comparison of Monte Carlo simulation of gamma ray attenuation coefficients of amino acids with XCOM program and experimental data, Results in Physics 9 (2018) 6-11.   DOI
13 P.S. Kore, P.P. Pawar, T.P. Selvam, Evaluation of radiological data of some saturated fatty acids using gamma ray spectrometry, Radiat. Phys. Chem. 119 (2016) 74-79.   DOI
14 C.J. Werner (Ed.), MCNP Users Manual - Code Version 6.2, LA-UR-17-29981, 2017.
15 R. Nowotny, XMuDat: Photon Attenuation Data on PC (version.1.0.1) IAEA-NDS-195(Vienna: IAEA), 1998.
16 P. Andreo, Monte Carlo techniques in medical radiation physics, Phys. Med. Biol. 36 (7) (1991) 861-920.   DOI
17 S. Agostinelli, et al., Geant4 - a simulation toolkit, Nucl. Instrum. Methods A 506 (2003) 250-303.   DOI
18 P. Arce, P. Rato, M. Canadas, J.I. Lagares, GAMOS: a GEANT4-based easy and flexible framework for nuclear medicine applications, in: 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference (2008 NSS/MIC), 2008.
19 S.R. Manohara, S.M. Hanagodimath, Studies on effective atomic numbers and electron densities of essential amino acids in the energy range 1 keV-100 GeV, Nucl. Instrum. Methods Phys. Res. B 258 (2007) 321-328.   DOI
20 Vishal V. Awasarmoln, Dhammajyot K. Gaikwad, Siddheshwar D. Raut, P. Pravina, Pawar. "Photon interaction study of organic nonlinear optical materials in the energy range 122-1330 keV, Radiat. Phys. Chem. 130 (2017) 343-350.   DOI