GALAXY CLUSTERS IN GAMMA-RAYS: AN ASSESSMENT FROM OBSERVATIONS

  • REIMER OLAF
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.307-313
    • /
    • 2004
  • Clusters of galaxies are believed to constitute a population of astrophysical objects potentially able to emit electromagnetic radiation up to gamma-ray energies. Evidence of the existence of non-thermal radiation processes in galaxy clusters is indicated from observations of diffuse radio halos, hard X-ray and EUV excess emission. The presence of cosmic ray acceleration processes and its confinement on cosmological timescales nearly inevitably yields in predicting energetic gamma-ray emission, either directly deduceably from a cluster's multifreqency emission characteristics or indirectly during large-scale cosmological structure formation processes. This theoretical reasoning suggests several scenarios to actually detect galaxy clusters at gamma-ray wavelengths: Either resolved as individual sources of point-like or extended gamma-ray emission, by investigating spatial-statistical correlations with unidentified gamma-ray sources or, if unresolved, through their contribution to the extragalactic diffuse gamma-ray background. In the following I review the situation concerning the proposed relation between galaxy clusters and high-energy gamma-ray observations from an observational point-of-view.

치료방사선과 영역의 적정관리 (Quality Assurance for Radiation Oncology)

  • 김귀언
    • 한국의료질향상학회지
    • /
    • 제2권1호
    • /
    • pp.110-117
    • /
    • 1995
  • The Comprehensive quality assurance for radiation oncology provides an overall organizational structures, responsibilities, procedures, processes and resources for assuring the quality of patient management by radiation treatment. Superior performance of modern radiotherapy equipment will be essential part of quality assurance in radiation oncology, which high degree of accuracy and consistency should be maintained under the optimal quality assurance program. Besides quality control of all radiation equipment, this review also emphasizes quality assurance of clinical aspect such as adequacy of the medical decision-making which eventually leads to the treatment prescription, accuracy of treatment procedure from treatment preparation to radiation delivery, and the significance of assessment of treatment outcomes with structure and process.

  • PDF

페놀의 촉매오존산화 반응에 관한 연구 (Catalytic Ozonation of Phenol)

  • 이철규;우정훈
    • 대한환경공학회지
    • /
    • 제33권10호
    • /
    • pp.731-738
    • /
    • 2011
  • 본 논문에서는 실험실적 규모의 순환형 회분식 반응기에서 수용액상 phenol을 처리하기 위해 $O_3/UV$ radiation, $O_3/Mg(OH)_2/UV$ radiation 그리고 $O_3/MgO/UV$ radiation 고급산화공정(AOPs)에 대한 연구를 수행하였다. 오존의 유량은 1.0 L/min, 오존 농도를 $150{\pm}10mg/L$로 일정하게 유지 하였으며, 산화반응에 나타나는 $COD_{Cr}$ 및 TOC를 각각 측정하였다. $20^{\circ}C$에서 $O_3/UV$ radiation, $O_3/Mg(OH)_2/UV$ radiation 그리고 $O_3/MgO/UV$ radiation에 대한 유사 1차 반응속도 상수는 각각 $9.31{\times}10^{-5}sec^{-1}$, $1.19{\times}10^{-4}sec^{-1}$ 그리고 $1.79{\times}10^{-4}sec^{-1}$, 활성화 에너지는 각각 $3.03kcal{\cdot}mol^{-1}$, $1.79kcal{\cdot}mol^{-1}$ 그리고 $4.23kcal{\cdot}mol^{-1}$ 로 나타났다. 수용액상에서 $Mg(OH)_2$와 MgO가 phenol의 분해와 COD의 제거에 현저한 촉진작용을 나타낸다는 것을 확인하였다. 이러한 실험 결과에 기초하여 $O_3/MgO/UV$ 시스템이 수용액상 phenol을 처리하기 위한 효율적이고 용이한 방법임을 제시하였다.

국내 수처리시설 종사자 작업유형에 따른 외부피폭방사선량 평가 (Assessment of External Radiation Dose for Workers in Domestic Water Treatment Facility According to the Working Type)

  • 전성훈;이성연;김혁재;김민성;김광표
    • 방사선산업학회지
    • /
    • 제17권2호
    • /
    • pp.151-160
    • /
    • 2023
  • The International Atomic Energy Agency (IAEA) proposes 11 industries that handle Naturally Occurring Radioactive Material (NORM) that are considered to need management. A water treatment facility is one of the above industries that takes in groundwater and produces drinking water through a water treatment process. Groundwater can accumulate natural radionuclides such as uranium and thorium in raw water by contacting rocks or soil containing natural radionuclides. Therefore, there is a possibility that workers in water treatment facilities will be exposed due to the accumulation of natural radionuclides in the water treatment process. The goal of this study is to evaluate the external radiation dose according to the working type of workers in water treatment facilities. In order to achieve the above goal, the study was conducted by dividing it into 1) analysis of the exposure environment, 2) measurement of the external radiation dose rate 3) evaluation of the external radiation dose. In the stage of analyzing the exposure environment, major processes that are expected to occur significantly were derived. In the measurement stage of the external radiation dose rate, a map of the external radiation dose rate was prepared by measuring the spatial radiation dose rate in major processes. Through this, detailed measurement points were selected considering the movement of workers. In the external radiation dose evaluation stage, the external radiation dose was evaluated based on the previously derived external radiation dose rate and working time. As a result of measuring the external radiation dose rate at the detailed points of water treatment facilities A to C, it was 1.90×10-1 to 3.75×100 μSv h-1, and the external radiation dose was analyzed as 3.27×10-3 to 9.85×10-2 mSv y-1. The maximum external radiation dose appeared during the disinfection and cleaning of activated carbon at facility B, and it is judged that natural radionuclides were concentrated in activated carbon. It was found that the external radiation dose of workers in the water treatment facility was less than 1mSv y-1, which is about 10% of the dose limit for the public. As a result of this study, it was found that the radiological effect of external radiation dose of domestic water treatment facility workers was insignificant. The results are expected to contribute as background data to present optimized safety management measures for domestic NORM industries in the future.

Recent Advances in Advanced Oxidation Processes

  • Huang, Chin-Pao
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 1998년도 가을 학술발표회 프로그램
    • /
    • pp.1-1
    • /
    • 1998
  • Advanced (Chemical) oxidation processes (AOP) differ from most conventional ones in that hydroxyl radical(OH.) is considered to be the primary oxidant. Hydroxyl radicalcan react non-selectively with a great number of organic and inorganic chemicals. The typical rate constants of true hydroxyl radical reactions are in the range of between 109 to 1012 sec-1. Many processes are possible to generate hydroxyl radical. These include physical and chemical methods and their combinations. Physical means involves the use of high energy radiation such as gamma ray, electron beam, and acoustic wave. Under an applied high energy radiation, water molecules can be decomposed to yield hydroxyl radicals or aqueous electrons. Chemical means include the use of conventional oxidants such as hydrogen peroxide and ozone, two of the most efficient oxidants in the presence of promoter or catalyst. Hydrogen peroxide in the presence of a catalyst such as divalent iron ions can readily produce hydroxyl radicals. Ozone in the presence of specific chemical species such as OH- or hydrogen peroxide, can also generate hydroxyl radicals. Finally the combination of chemical and physical means can also yield hydroxyl radicals. Hydrogen peroxide in the presence of acoustic wave or ultra violet beam can generate hydroxyl radicals. The principles for hydroxyl radical generation will be discussed. Recent case studied of AOP for water treatment and other environmental of applications will be presented. These include the treatment of contaminated soils using electro-Fenton, lechate treatment with conventional Ponton, treatment of coal for sulfur removal using sonochemical and the treatment of groundwater with enhanced sonochemical processes.

  • PDF

Si PIN Radiation Sensor with CMOS Readout Circuit

  • Kwon, Yu-Mi;Kang, Hee-Sung;Lee, Jung-Hee;Lee, Yong Soo
    • 센서학회지
    • /
    • 제23권2호
    • /
    • pp.73-81
    • /
    • 2014
  • Silicon PIN diode radiation sensors and CMOS readout circuits were designed and fabricated in this study. The PIN diodes were fabricated using a 380-${\mu}m$-thick 4-inch n+ Si (111) wafer containing a $2-k{\Omega}{\cdot}cm$ n- thin epitaxial layer. CMOS readout circuits employed the driving and signal processes in a radiation sensor were mixed with digital logic and analog input circuits. The primary functions of readout circuits are amplification of sensor signals and the generation of the alarm signals when radiation events occur. The radiation sensors and CMOS readout circuits were fabricated in the Institute of Semiconductor Fusion Technology (ISFT) semiconductor fabrication facilities located in Kyungpook National University. The performance of the readout circuit combined with the Si PIN diode sensor was demonstrated.

Multiscale Modeling of Radiation Damage: Radiation Hardening of Pressure Vessel Steel

  • Kwon Junhyun;Kwon Sang Chul;Hong Jun-Hwa
    • Nuclear Engineering and Technology
    • /
    • 제36권3호
    • /
    • pp.229-236
    • /
    • 2004
  • Radiation hardening is a multiscale phenomenon involving various processes over a wide range of time and length. We present a multiscale model for estimating the amount of radiation hardening in pressure vessel steel in the environment of a light water reactor. The model comprises two main parts: molecular dynamics (MD) simulation and a point defect cluster (PDC) model. The MD simulation was used to investigate the primary damage caused by displacement cascades. The PDC model mathematically formulates interactions between point defects and their clusters, which explains the evolution of microstructures. We then used a dislocation barrier model to calculate the hardening due to the PDCs. The key input for this multiscale model is a neutron spectrum at the inner surface of reactor pressure vessel steel of the Younggwang Nuclear Power Plant No.5. A combined calculation from the MD simulation and the PDC model provides a convenient tool for estimating the amount of radiation hardening.

목재 펄프 제조 공정에서의 방사선 효과 및 특성 (Characteristics and Effects of Radiation Treatment on Wood Pulping Process)

  • 원소라;신혜경;전준표;강필현
    • 방사선산업학회지
    • /
    • 제5권3호
    • /
    • pp.227-230
    • /
    • 2011
  • Pulps were separated from wood chips using an Electron beam irradiation (EBI) treatment without a NaOH-AQ (anthraquinone) treatment for cooking. The methods were based on a hot water treatment after EBI and two-step bleaching processes. Chemical compositions and FT-IR spectroscopy demonstrated that the content of lignin and hemicellulose in the bleached wood pulps treated with various EBI dose decreased with an increase of EBI doses. Specifically, the lignin in the bleached with pulps treated at 600 kGy of EBI dose was almost completely removed. Moreover, TGA analysis showed that a thermal stability increased with increasing the content of cellulose but the lignin decomposed slowly over the wide region.

Radiation-induced Cochlea Hair Cell Death: Mechanisms and Protection

  • Tan, Pei-Xin;Du, Sha-Sha;Ren, Chen;Yao, Qi-Wei;Yuan, Ya-Wei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권10호
    • /
    • pp.5631-5635
    • /
    • 2013
  • Cochlea hair cell death is regarded to be responsible for the radiation-induced sensorineural hearing loss (SNHL), which is one of the principal complications of radiotherapy (RT) for head and neck cancers. In this mini-review, we focus on the current progresses trying to unravel mechanisms of radiation-induced hair cell death and find out possible protection. P53, reactive oxygen species (ROS) and c-Jun N-terminal kinase (JNK) pathways have been proposed as pivotal in the processes leading to radiation hair cell death. Potential protectants, such as amifostine, N-acetylcysteine (NAC) and epicatechin (EC), are claimed to be effective at reducing radiation-inducedhair cell death. The RT dosage, selection and application of concurrent chemotherapy should be pre-examined in order to minimize the damage to cochlea hair cells.

Excell 프로그램을 통한 치료선량(M. U) 계산 (Monitor Unit calculation through Excell program)

  • 임광채;조은주;조선행
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.28-32
    • /
    • 1999
  • Verifying the treatment value(Monitor Unit) unnecessarily involves too many simple and repetitive calculation processes, that is, individual computation process using the data(PDD value, Scp Factor, SSD Factor, Tray Factor) on the data book. We intend to minimize the time required to check the Monitor Unit through computerized calculation. Using $^{\ast}(multiplication)$, /(division), +(sum), if function, among others, which are present in the Excell program, MS office program, the Monitor Unit was obtainable through A/P value, Scp Factor and PDD value, Wedge Factor. From the verification of the computations of Monitor Unit for 60 patients previously treated, we were able to obtain an error rate of ${\pm}0.028MU$. Computerized calculation of the Monitor Unit could save the burden of Technologist.