• Title/Summary/Keyword: radiation industries

Search Result 119, Processing Time 0.023 seconds

The Status and Prospects of Accelerators in Radiation Industries (방사선 산업용 가속기의 현황과 전망)

  • Chai, Jong-Seo
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.101-110
    • /
    • 2012
  • This paper is described the review of several selected accelerators and the use of accelerators in various purposes. The electrostatic accelerators and RF accelerators have been developed before the second world war for the purpose of basic research of physics mainly. RF driven accelerators have been achieved higher energy and applied in medical and industrial use after 1980's. Accelerators have improved incorporating new technologies : axial and horizontal injection, stripping extraction, superconducting RF, computer control, superconducting magnet etc.. Also recent key technologies as BT and NT make the expansion of applications of the accelerators.

Design of radiation detection circuit for gamma column scanning (자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계)

  • Kim, Jong-Beom;Jeong, Seong-Hui
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF

Removal of EDCs from Industrial Sludge by Electron Beam

  • Han, Bumsoo;Kim, Jinkyu;Kim, Yuri;Jung, Seungtae;Park, Junhyung;Choi, Jangseung
    • Journal of Radiation Industry
    • /
    • v.8 no.2
    • /
    • pp.71-76
    • /
    • 2014
  • Endocrine disrupting chemicals (EDCs) and potential EDCs are mostly man-made, found in various materials such as pesticides, additives or contaminants in food, and personal care products. The high energy ionizing radiation has the ability to remove the EDCs with a very high degree of reliability and in a clean and efficient manner. The ionizing radiation interacts with EDCs both directly and indirectly. Direct interaction takes place with EDCs and the structure of EDCs is destroyed or changed. During indirect interaction, radiolysis products of water result in the formation of highly reactive intermediates which then react with the target molecules, culminating in structural changes. To confirm the radiation reduction of EDCs in industrial sludge, a pilot scale experiment up to 50 kGy of electron beam (EB) was conducted with samples from the textile dyeing industries. The experimental result showed the over 90% of reduction of Nonylphenol (NP) and Di(2-ethylhexyl) phthalate (DEHP) at around 10 kGy of absorbed doses.

Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea (한국에서 방사선 관련 종사자들의 개인피폭선량 실태에 관한 연구)

  • Lim, Bong-Sik
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.185-195
    • /
    • 2006
  • Purpose: This study investigated the status of radiation exposure doses since the establishment of the "Regulations on Safety Management of Diagnostic Radiation Generation Device" in January 6, 1995. Method: The level of radiation exposure in people engaged or having been engaged in radiation-related industries of inspection organizations, educational organizations, military units, hospitals, public health centers, businesses, research organizations or clinics over a 5 year period from Jan. 1, 2000 to Dec. 31, 2004 was measured. The 149,205 measurement data of 57,136 workers registered in a measurement organization were analysed in this study. Frequency analysis, a Chi-square test, Chi-square trend test, and ANOVA was used for data analysis. Results: Among 57,136, men were 40,870(71.5%). 50.3% of them were radiologic technologists, otherwise medical doctors(22.7%), nurse(2.9%) and others(24.1%). The average of depth radiation and surface radiation during the 5-year period were found to decrease each year. Both the depth radiation and surface radiation exposure were significantly higher in males, in older age groups, in radiological technologists of occupation. The departments of nuclear medicine had the highest exposure of both depth and surface radiation of the divisions of labor. There were 1.98 and 2.57 per 1,000 person-year were exposed more than 20 mSv(limit recommended by International Commission on Radiological Protection) in depth and surface radiation consequently. Conclusion: The total exposure per worker was siginifcantly decreased by year. But Careful awareness is needed for the workers who exposed over 20 mSv per year. In order to minimize exposure to radiation, each person engaged in a radiation-related industry must adhere to the individual safety management guidelines more thoroughly. In addition, systematic education and continuous guidance aimed at increasing the awareness of safety must be provided.

  • PDF

A System for Thermal Distortion Analysis of Hull Structures by Solar Radiation (선체의 태양복사 열변형 해석을 위한 전처리시스템)

  • Ha, Yunsok;Lee, Donghoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.4
    • /
    • pp.275-281
    • /
    • 2016
  • One of the most important things for quality to meet ship-production schedule is an accuracy control. A ship is assembled by welding through whole production process, so it is important that loss by correction will not happen as much as possible by using some engineering skills like reverse design, reverse setting and margin for thermal shrinkage. These efforts are a quite effective in fabrication stages, but not in erection stages. If a ship block which consists of common steel is exposed to directional solar radiation, its dimensional accuracy will change high as time by its thermal expansion coefficient. Therefore, the measuring work would be often done at dawn or evening even with having a very accurate device. In this study, an FE analysis method is developed to solve this problem. It can change measured data affected by solar thermal distortion to ones not, even though ship-block is measured at an arbitrary time. It will use the time when measuring, the direction of block and the weather record by satellites. It is confirmed by a comparison between measured data of a ship-block and the result by suggested analysis method. Furthermore, a pre-processing system is also developed for fast application of the suggested analysis method.

Modeling Phased Array Ultrasonic Testing of a Flat-Bottom Hole in a Single Medium

  • Park, Joon-Soo;Kim, Hak-Joon;Song, Sung-Jin;Seong, Un-Hak;Kang, Suk-Chull;Choi, Young-Hwan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.6
    • /
    • pp.467-474
    • /
    • 2005
  • The expanded multi-Gaussian beam model has recently been developed that can calculate the radiation beam field from a single, rectangular transducer with great computational efficiency. In this study, this model is adopted to calculate the radiation beam field for a phased array transducer with various time delays to achieve steering and/or focusing. The calculation beam fields are compared to those obtained by well known Rayleigh-Sommerfeld integral that provides the exact solution in order to explore the validity of the expanded multi-Gaussian beam model And then, this study proposes a complete ultrasonic measurement model including the expanded beam model, far-field scattering model and system efficiency, Using the proposed model, phased array ultrasonic testing signals for a flat-bottomed hole with/without focusing were performed.

Synthesis of a Novel Compound from Gallic Acid and Linoleic Acid and its Biological Functions

  • Jo, Cheo-Run;Jeong, Ill-Yun;Lee, Na-Young;Kim, Kwan-Soo;Byun, Myung-Woo
    • Food Science and Biotechnology
    • /
    • v.15 no.2
    • /
    • pp.317-320
    • /
    • 2006
  • Octadeca-9,12-dienyl-3,4,5-hydroxybenzoate (GA-LA) was chemically synthesized from gallic acid and linoleic acid ester, and its biological functions were tested. Radical-scavenging activity of GA-LA was comparable to those of gallic and ascorbic acids at 0.24 mM, and tyrosinase inhibition effect was higher than that of ascorbic acid. Gallic and linoleic acids did not show any tyrosinase activity. Results of cyclooxygenase (COX) inhibition effect indicate GA-LA has higher selectivity in COX-1 inhibition. GA-LA from gallic and linoleic acids could be used as functional reagent for antioxidative, skin-whitening, and anti-inflammatory effects in food, pharmaceutrical, and cosmetic industries.

Governmental Science and Technology Policy-Making on Technology-Intensive Industry Based on Allison's Models : Focused on the Nuclear and Radiation Field (앨리슨모형을 기반으로 한 기술집약적 산업의 정부 과학기술 정책결정: 원자력 및 방사선 분야를 중심으로)

  • Cha, Seokki
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.4
    • /
    • pp.507-514
    • /
    • 2018
  • Technology-intensive industries can be used as a major growth engine for resource poor country in the territories. For example, in the case of Korea, nuclear power and radiation technology industry was highly developed, and it was possible to obtain national interests such as solving energy problems within the country and exporting nuclear power plants. On the other hand, there are cases where national damage is caused by erroneous governmental policy-making on technology-intensive sectors. In this study, we analyzed cases of misguided governmental policy-making for technology-intensive industry and three factors were identified. And we tried to develop a rational policy-making model using three types of allison's model in combination. The results of this study are expected to be useful for rational governmental policy-making processes for technology-intensive industries.

Ground High/Low Temperature Test for FA-50 Aircraft (FA-50 경공격기 전기체 지상 고/저온시험)

  • Ahn, Jong Hoon;Kim, Tae Ho;Woo, Seung Cheol;Cho, Young Kyun;Kim, Do Wan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The ground high/low temperature test objective is to check the normal ground operation of FA-50 aircraft in the extreme ground ambient conditions. The aircraft was exposed in climatic conditions of the basic climatic category according to the MIL-HDBK-310. For verified normal operation in the extreme high temperature, the high temperature test was performed in the hot regional type conditions and accentuated solar radiation heat. This test was performed at the test chamber in ADD where is in Haemi. This paper was described about the test procedure of FA-50 high/low temperature including preparation, testing and results.

  • PDF

Commissioning and Validation of a Dedicated Scanning Nozzle at Samsung Proton Therapy Center

  • Chung, Kwangzoo;Han, Younyih;Ahn, Sung Hwan;Kim, Jin Sung;Nonaka, Hideki
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.267-271
    • /
    • 2016
  • In this study, we present the commissioning and validation results of a dedicated scanning nozzle. The dedicated scanning nozzle is installed in one of the two gantry treatment rooms at Samsung Proton Therapy Center. Following a successful completion of the acceptance test, the commissioning process including the beam data measurement for treatment planning system has been conducted. Extended measurements have been conducted as a validation of the clinical performance of the nozzle and various quality assurance protocols have been prepared.