• Title/Summary/Keyword: radiation dose

Search Result 5,019, Processing Time 0.039 seconds

Korean Clinical Imaging Guidelines for the Appropriate Use of Chest MRI (한국형 흉부 MRI 영상 진단 정당성 권고안)

  • Jiyoung Song;Bo Da Nam;Soon Ho Yoon;Jin Young Yoo;Yeon Joo Jeong;Chang Dong Yeo;Seong Yong Lim;Sung Yong Lee;Hyun Koo Kim;Byoung Hyuck Kim;Kwang Nam Jin;Hwan Seok Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.562-574
    • /
    • 2021
  • MRI has the advantages of having excellent soft-tissue contrast and providing functional information without any harmful ionizing radiation. Although previous technical limitations restricted the use of chest MRI, recent technological advances and expansion of insurance coverage are increasing the demand for chest MRI. Recognizing the need for guidelines on appropriate use of chest MRI in Korean clinical settings, the Korean Society of Radiology has composed a development committee, working committee, and advisory committee to develop Korean chest MRI justification guidelines. Five key questions were selected and recommendations have been made with the evidence-based clinical imaging guideline adaptation methodology. Recommendations are as follows. Chest MRI can be considered in the following circumstances: for patients with incidentally found anterior mediastinal masses to exclude non-neoplastic conditions, for pneumoconiosis patients with lung masses to differentiate progressive massive fibrosis from lung cancer, and when invasion of the chest wall, vertebrae, diaphragm, or major vessels by malignant pleural mesothelioma or non-small cell lung cancer is suspected. Chest MRI without contrast enhancement or with minimal dose low-risk contrast media can be considered for pregnant women with suspected pulmonary embolism. Lastly, chest MRI is recommended for patients with pancoast tumors planned for radical surgery.

The Treatment of LNAPL(BETXlMTBE) Contaminated Groundwater Applying Photo-assisted Fenton Reaction with Various Fe(III) Chelator (Photo-assisted Fenton 반응에 다양한 Fe(III) chelator를 적용한 LNAPL(BTEX/MTBE)오염 지하수 처리에 관한 연구)

  • Park, Jong-Hun;Do, Si-Hyun;Lee, Hong-Kyun;Jo, Young-Hoon;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.26-32
    • /
    • 2009
  • In this study, the degradation of BTEX (benzene, toluene, ethylbenzene, xylene) was tested in both (Fe$^{3+}$+chelating agent)/H$_2$O$_2$system [Fe(III) 1 mM, oxalate 6 mM, H$_2$O$_2$ 3%, and pH 6] and UV/(Fe3++ chelating agent)lHzOz system [UV dose 17.4 kWhlL, Fe(III) 1mM, oxalate 6 mM,H$_2$O$_2$ 1%, and pH 6]. The types of chelating agents used in experiments were catechol, NTA, gallic, acetyl acetone, succinic, acetate, EDTA, citrate, malonate, and oxalate and the optimum chelating agent for BTEX degradation was determined. The results showed that acetate was the optimum chelating agent for BTEX degradation in both (Fe$^{3+}$+chelating agent)/H$_2$O$_2$ and UV/(Fe$^{3+}$+chelating agent)/H$_2$O$_2$ system, and UV radiation enhanced the degradation of BTEX with any types of chelating agents. Moreover, UV/(Fe$^{3+}$+chelating agent)/H$_2$O$_2$ system, which chelating agent was acetate, removed effectively mixtures of BTEX and MTBE (methyl tert-butyl ether) when the concentration of both BTEX and MTBE was 200 mg/L, respectively. In this system, BTEX was degraded completely and 85% of MTBE was degraded at the reaction time of 180 min. Therefore, UV/((Fe$^{3+}$+chelating agent)/H$_2$O$_2$ system with acetate as a chelating agent removed not only BTEX but also BTEX and MTBE, effectively.

Preservation of Kimchi by ${\gamma}-Ray$ Irradiation (감마선 조사에 의한 김치저장에 관한 연구)

  • Kang, Se-Sik;Lee, Jong-Seok;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.11 no.1
    • /
    • pp.71-77
    • /
    • 1988
  • To improve the storage method for kimchi, optimal ripening kimchi was irradiated with doses of 1, 3, 5kGy Co-60gamma radiation, followed by the microbiological, physicochemical and senosory evaluations during storage at $5^{\circ}C$. 1. Total aerobic count increased in the beginning of storage and then decreased slowly as the number of total lactobacilli (anaerobe) increased. The above, total aerobic and lactobacilli were reduced by 1 to 3 log cycles with irradiation and at the 90th day after storage the number of total lactobacilli remained $1.30{\times}10^{8}$ per ml in 3 kGy irradiated group. Irradiation treatment at 3 kGy sterilized coliforms and molds contaminating the sample as the level of $2.0{\times}10^{4}$ per ml and $5.4{\times}10^{2}$ per ml respectively and no apparent growth was observed in both control and 1 kGy irradiated groups after 20 days of storage. The population of yeast, $3.5{\times}10^{3}$ per ml initially, increased steadily during kimchi storage and at 90 days of storage the number was shown to be $5.6{\times}10^{4}$ per ml and $6.5{\times}10^{2}$ per ml in control and 3 kGy irradiated groups, respectively. 2. In the physicochemical changes during kimchi storage, pH, acidity and volatile acid of non-irradiated control at the 45th day after storage were 4.0, 0.7% and 0.066%, while those of 3 kGy irradiated group were 4.2, 0.59 and 0.06% at the 90th day of storage, respectively. The reducing sugar content of all stored samples changed inversely total acidity content, indicating irradiation delayed the changes of them. The amount of ascorbic acid decreased gradually with the storage time and irradiation dose increase. Textural parameters of 3 kGy irradiated group were superior to those of other groups at the latter stage of storage. 3. Sensory evaluations showed that 3 kGy irradiation was the optimum dose level to extend the shelf-life of kimchi more than two months as compared to control.

  • PDF

Effects of Sea Buckthorn (Hippophae rhamnoides L.) Fruit Extract on Ultraviolet-induced Apoptosis of Skin Fibroblasts (UV조사에 의해 유도된 피부섬유아세포의 세포사에 미치는 Sea Buckthorn (Hippophae rhamnoides L.) 열매추출물의 영향)

  • Hwang, In Sik;Koh, Eun Kyoung;Kim, Ji Eun;Lee, Young Ju;Kwak, Moon Hwa;Go, Jun;Sung, Ji Eun;Song, Sung Hwa;Hwang, Dae Youn
    • Journal of Life Science
    • /
    • v.24 no.5
    • /
    • pp.467-475
    • /
    • 2014
  • Sea buckthorn (Hippophae rhamnoides L.) is a well-known and rich source of biologically active compounds, such as flavonoids, carotenoids, steroids, vitamins, tannins, and oleic acid. The effects of sea buckthorn fruit extract (SBFE) on ultraviolet (UV)-induced cell death was investigated in SK-MEL-2 cells cotreated with UV and a low concentration (LoC), medium concentration (MeC), or high concentration (HiC) of SBFE. Cell viability gradually decreased in accordance with an increase in the UV dose. The cell viability of the UV+SBFE cotreated cells increased significantly compared to that of UV+vehicle-treated cells during the application of an appropriate UV radiation dose (400 mJ). In addition, the number of 4',6-diamidino-2-phenylindole (DAPI), propidium iodine (PI)-, and annexin V-stained apoptotic cells was higher in the UV+vehicle-treated cells than in the UV untreated cells. The decrease of apoptotic cell numbers varied in each treated group, but it was most significant in the SBFE-treated group. The number of PI-stained cells dramatically decreased in accordance with the concentration of SBFE, and the maximum decrease was detected in the UV+HiC-treated group. In addition, Bax expression increased and Bcl-2 expression decreased in the SBFE-treated group compared with the UV-only treated group. The level of caspase-3 remained constant in all the groups. These results suggest that SBFE may contribute to a recovery from UV-induced cell death through the regulation of apoptotic protein expression and that it may have potential therapeutic utility in ameliorating UV-induced skin ageing.

Preliminary Investigations of the Dosimetric Properties of a Normoxic Polymethacrylic Acid Gel Dosimeter Using a Respiration-Motion Simulator (호흡모의움직임장치를 이용한 정상산소 폴리메타크릴산 겔 선량계의 선량특성)

  • Park, Chae Hee;Cho, Yu Ra;Cho, Kwang Hwan;Park, Ji Ae;Kim, Kyeong Min;Kim, Kum Bae;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.138-144
    • /
    • 2012
  • Dose distribution throughout the clinical organ range of motion was analyzed using a respiratory-motion simulator that was equipped with a polymer gel dosimeter and EBT2 film. The normoxic polymer gel dosimeter was synthesized from gelatin, MAA, HQ, THPC and HPLC. The gel dosimeter and EBT2 film were irradiated with Co-60 gamma rays that were moved along the x-axis and y-axis in ${\pm}1.5cm$ steps at five-second intervals. The field size was $5{\times}5cm^2$. The SSD was 80 cm and set to 10 Gy at a depth of 2 cm. The PDD at a depth of 50 mm was 75.2% in the ion chamber, 82.3% in the static state and 86.1% in the dynamic state in the gel dosimeter. The penumbra for the dynamic state target, which was measured using the gel dosimeter, averaged 10.89 mm, this is a 40.5% increase over the penumbra of the static state target of 7.74 mm. In addition, when measuring with gel dosimetry, the value for the penumbra is 36.6% smaller in the static state and 29.4% smaller in the dynamic state compared to measuring with film. The aim of this study was to investigate the dosimetric properties of a normoxic polymethacrylic acid gel dosimeter in static and dynamic states and to evaluate the potentiality as a relative dosimeter for dynamic therapeutic radiation.

Radurization Effect of Korean Mackerel (한국산 고등어의 방사선 조사효과)

  • CHO S. J.;CHOE Y. K.;LEE S. Y.;BYUN S. M.;CHUNG J. R.
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.3
    • /
    • pp.219-226
    • /
    • 1985
  • To investigate potential application of radurization technique as an effective tool for controlling histamine accumulation, histamine contents were determined in fresh Korean mackerel meat samples irradiated at six dose levels of gamma radiation up to 1 Mrad during 35 day-storage at $0^{\circ},\;5^{\circ}\;and\;10^{\circ}C$. Total bacterial counts, total volatile bases and trimethylamine contents were also estimated. The minimum and maximum doses for Korean mackerel were determined to be 0.2 and 0.5 Mrad, respectively. Irradiation induced redening of fish muscle tissue and redening appeared to be dose dependent. At low doses, this redening contributed positively to the overall sensory qualities. At 0.5 and 1.0 Mrad, on the other hand, meat samples were excessively redened to the extent that red and white muscle layers were not readily distinguishable. No appreciable histamine accumulation occured during entire 35 day-storage in fresh mackerel meats, whether irradiated or not, when they were kept at ice temperature. At $5^{\circ}C$, histamine started to accumulate slightly during late storage in the samples irradiated at low doses. Even in the unirradiated samples, the histamine accumulation did not exceed the level of 10.0 mg per 100g meat until the 28th day at $5^{\circ}C$. At $10^{\circ}C$, however, histamine accumulation in the unirradiated was phenomenal from very early storage and the values reached 827.5 mg per 100g meat by the 35th day, while histamine accumulation in the irradiated was severely suppressed. Irradiation invariably brought about a significant reduction of initial microflora, disrupting normal spoilage pattern. This was reflected in the suppression of not only histamine but also total volatile bases and trimethylamine accumulation during post-irradiation storage at refrigerated temperatures.

  • PDF

Evaluation of Image According to Exposure Conditions using Contrast-Detail Phantom for Chest Digital Radiography (흉부 디지털 방사선 촬영 시 C-D phantom을 이용한 촬영조건에 따른 영상 평가)

  • Lee, In-Ja;Kim, You-Hyun;Kim, Chang-Nam;Lee, Chang-Yeob;Park, Kye-Yeon
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.25-32
    • /
    • 2009
  • To find out proper photographing conditions in the chest DR imaging, the evaluation of images using the C-D phantom was carried out on relationship of identification capability, graininess, and exposure ratio. The conclusions were obtained as follows. 1. The patient's entrance skin Exposure (ESE) was decreased as tube voltage was increased. 2. According to the tube voltage change, the C-D phantom's identification capability of the exposure conditions was most visible at 110 kVp. 3. The identification capability according to the exposure ratio (mAs) change was most visible at 90 kVp for 0.5 times of low exposure ratio and at 110 kVp for 1.5 times. Therefore, it is known that the images were able to be better identified at a high exposure than a low exposure. 4. The graininess according to the exposure ratio at tube voltage of 110 kVp resulted in the best thing at 1.5 times of ratio when the exposure ratio was 1.5 times increased and the tube voltage was changed, the graininess showed the best result at 110 kVp. Therefore, the patient's exposure dose was low when kVp was increased and the adequate kVp was found to be 110. The image was better identified when exposure ratio was 1.5 times compared to 1.0 times. The graininess was also good when the exposure ratio became 1.5 times. The tube voltage was good at 110 kVp. However, once the exposure ratio is increased, the amount of radiation dose that the patients received get increased, so that the exposure condition has to be thoroughly considered.

  • PDF

Histological Changes in the Normal Tissues of Rat after Local Application of the Holmium-166-Chitosan Complex attached to Biodegradable Solid Material (생분해성 고형물에 흡착시켜 실험동물에 국소 투여한 홀미움- 166-키토산 복합체의 투여량, 기간 및 부위에 따른 조직의 괴사 정도와 양상)

  • Lee, Jong-Seok;Jeon, Dae-Geun;Cho, Wan-Hyung;Lee, Soo-Yong;Oh, Jung-Moon;Kim, Jin-Wook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.190-199
    • /
    • 2003
  • Purpose: The aim of this study was to find out a clinically appliable method to insert a biodegradable solid material containing holmium-166-chitosan complex into the surgical field, and to evaluate the histological changes in the normal tissues after ${\beta}$ -ray irradiation from holmium-166 according to the dose, period and type of tissues. Materials and Methods: 3.0 mCi, 50 ${\mu}l$ of the liquid state $^{166}$Ho-chitosan complex was attached to the absorbable gelatin sponge. The radiation activity measured by dose caliberator was 1.5 mCi. These $^{166}$Ho-chitosan complex containing absorbable gelatin sponges were inserted into the thigh muscles and over the femur bones of the Wistar rats. The cases were evaluated at 2 weeks after insertion, and 4, 6 weeks with respect to the histological changes of the soft tissues and bone, the depth of the tissue necrosis, and the changes of the $^{166}$Ho-chitosan complex containing absorbable gelatin sponges. Results: At 2 weeks, the muscles showed coagulation necrosis, degenerating myocytes, regenerating myocytes, intermuscular edema, and inflammatory cells. The necrosis depth was 3.3 mm. In the bones, there was no osteocyte in the lacuna of cortex (empty lacuna), marrow fibrosis, inflammation. The necrosis depth was 2.9 mm. At 4 weeks, in the muscle, calcification and increased fibrosis with necrosis depth by 3.3 mm were the additional findings. In the bone, marrow fibrosis with necrosis depth by 3.3 mm were detected. At 6 weeks, soft tissue shrinkage, increased fibrosis and granulation tissue formation, and nearly resolving inflammatory reaction were the findings. Conclusion: The local application of the $^{166}$Ho-chitosan complex attached to biodegradable gelatin material with surgery in the laboratory animals resulted in no mortality and morbidity, and satisfactory tissue necrosis. Holmium-166 can be applied to the treatment of the malignant tumor patients.

  • PDF

A Case of Pharmacokinetics of Cisplatin in Concurrent Chemoradiation for Hemodialysis Patient with Advanced Head and Neck Cancer (혈액 투석을 받는 두경부암 환자의 동시화학방사선요법에서 Cisplatin의 약력학 조사 1예)

  • Jeon, Youn-Joo;Shim, Byoung-Yong;Kim, Hyung-Wook;Lee, Sang-Hun;Lee, Ho-Sang;Park, Cheol-Whee;Kim, Su-Zy;Kuh, Hyo-Jeong;Kim, Hoon-Kyo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.2
    • /
    • pp.153-156
    • /
    • 2007
  • Objectives : We study the feasibility and pharmacokinetics of cisplatin concurrent chemoradiation for advanced head and neck cancer patient undergoing hemodialysis. Materials and Methods : A 57-year old male with end stage renal disease developed stage III external auditory canal cancer. Complete resection surgery was done. Postoperative 6 months, local recurrence was occurred. Despite excision and adjuvant radiotherapy, local tumor was recurred. We decided to treat a cisplatin concurrent chemoradiotherapy. Cisplatin was administered at a dose of $20mg/m^2$ for 30 min. Hemodialysis was started 30 min after completion of the cisplatin infusion and performed for 4 hours. Hemodialysis was performed on day 3 and 5 of chemotherapy. Plasma samples were collected at specified times after administration of cisplatin. Result : At the end of the third cycle of cisplatin concurrent chemoradiotherapy, the tumor size was markedly decreased. The maximum plasma concentrations of plasma platinum and free platinum were 0.74 and $0.37{\mu}g/ml$ respectively. The area under the curve of plasma platinum and free platinum were 94.7 and $11.3{\mu}g{\cdot}h/ml$ respectively. Conclusion : We report a case of Cisplatin concurrent chemoradiation for hemodialysis patient with advanced head and neck cancer and suggest full dose cisplatin concurrent chemoradiotherpay is tolerable for these patients.

Study on Optimized Dispensing of F-18 FDG Auto Dispenser (F-18 FDG 자동분주기의 분주 최적화에 관한 연구)

  • Ji, Bong-Geun;Lee, Sang-Hun;Kim, Jong-Eon;Kim, Won-Tae;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.377-384
    • /
    • 2016
  • This is a study on the optimized dispensing of the auto dispenser used for the purpose of reducing the exposure dose and accurate radiation dose of radioisotope with regard to the PET/CT practitioners. The research method was to find the optimized dispensing method through evaluating the results according to the syringe type, dispensing rate, and vial pressure and through the application of corrected values. As a result of this study, 9.38 mCi has been dispensed on average in the case of 5 ml syringe, and the reproducibility close to 10 mCi was shown at the dispense of 9.55 mCi in the case of 3 ml syringe. In the evaluation according to the dispensing rate, the quantity of radioisotope close to 10 mCi was dispensed at the rate of 5 mm/min when the measurement was carried out by increasing the rate by 5 mm/min units in the order of 5, 10, 15 and 20 mm/min. In the evaluation result according to the vial pressure before/after the use of Needle filter, it was measured to be 9.53 mCi before use and 9.84 mCi after use confirming that the dispensing after using Needle filter showed the optimal value. In addition, in the evaluation of radioactivity before/after the application of corrected values according to the increase in dispense frequency, it was measured 9.53 mCi before correction and 10.07 mCi after correction confirming that the value with correction applied was closer to the quantitative value. Thus, a good optimized method was confirmed to use a 3 ml syringe with dispensing rate of 5 mm/min, to use a Needle filter at dispensing, and to set the corrected value of [$y=0.097{\times}x$] according to the dispensing frequency of equipment.