Characterization of New Avalanche Photodiode Arrays for Positron Emission Tomography

  • Song, Tae-Yong;Park, Yong;Chung, Yong-Hyun;Jung, Jin-Ho;Jeong, Myung-Hwan;Min, Byung-Jun;Hong, Key-Jo;Choe, Yearn-Seong;Lee, Kyung-Han
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.45-45
    • /
    • 2003
  • The aim of this study was the characterization and performance validation of new prototype avalanche photodiode (APD) arrays for positron emission tomography (PET). Two different APD array prototypes (noted A and B) developed by Radiation Monitoring Device (RMD) have been investigated. Principal characteristics of the two APD array were measured and compared. In order to characterize and evaluate the APD performance, capacitance, doping concentration, quantum efficiency, gain and dark current were measured. The doping concentration that shows the impurity distribution within an APD pixel as a function of depth was derived from the relationship between capacitance and bias voltage. Quantum efficiency was measured using a mercury vapor light source and a monochromator used to select a wavelength within the range of 300 to 700 nm. Quantum efficiency measurements were done at 500 V, for which the APD gain is equal to one. For the gain measurements, a pencil beam with 450 nm in wavelength was illuminating the center of each pixel. The APD dark currents were measured as a function of gain and bias. A linear fitting method was used to determine the value of surface and bulk leakage currents. Mean quantum efficiencies measured at 400 and 450 nm were 0.41 and 0.54, for array A, and 0.50 and 0.65 for array B. Mean gain at a bias voltage of 1700 V, was 617.6 for array A and 515.7 for type B. The values based on linear fitting were 0.08${\pm}$0.02 nA 38.40${\pm}$6.26 nA, 0.08${\pm}$0.0l nA 36.87${\pm}$5.19 nA, and 0.05${\pm}$0.00 nA, 21.80${\pm}$1.30 nA in bulk surface leakage current for array A and B respectively. Results of characterization demonstrate the importance of performance measurement validating the capability of APD array as the detector for PET imaging.

  • PDF

MDCT의 관전압, 관전류, 슬라이스 두께 변화에 따른 팬텀의 선량 분포 측정 (Dose Measurements using Phantoms for Tube Voltage, Tube Current, Slice Thickness in MDCT)

  • 이창래;전성수;남소라;조효민;정지영;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제18권3호
    • /
    • pp.139-143
    • /
    • 2007
  • 본 연구는 MDCT (multi-detector computed tomography) 파라미터 변화에 따른 환자선량을 측정하고 평가 하고자 하였다. MDCT 파라미터의 다양한 변화에 의한 환자선량은 MDCT (GE light speed plus 4 slice, USA)와 model 2026C electrometer (RADICAL 2026C, USA), 그리고 head와 body의 CT선량 표준팬텀(standard polymethylmethacrylate)을 사용하여 측정 하였다. 그 결과 환자선량 $CTDI_w$ 값은 관전압과 관전류가 증가할수록 선형적으로 증가하였고 beam collimation이 증가 할수록 감소하였다. 따라서 관전압, 관전류는 환자의 피폭선량에 직접적인 영향을 주고 슬라이스 두께는 영향이 적은 것을 알 수 있었다. 임상의 전형적인 MDCT 복부 scan에서 120 kVp, 180 mAs, 20 mm collimation과 0.75 pitch의 조건하에 $CTDI_w$$CTDI_{vol}$의 측정값은 각각 20.2 mGy, 26.9 mGy이었고 스캔 길이가 271.3 mm인 환자의 DLP와 유효선량은 각각 $729.1\;mGy{\cdot}cm$, 10.9 mSv였다.

  • PDF

Screen printing method로 제작된 의료용 광도전체 필름의 Tickness의 따른 X선 검출 특성 평가 (The study of X-ray detection characteristic and fabrication photoconductor film thickness for Screen printing method)

  • 이영규;윤민석;김동혁;천송이;정복동;강상식;박지군;문치웅;남상희
    • 한국방사선학회논문지
    • /
    • 제3권2호
    • /
    • pp.11-16
    • /
    • 2009
  • $HgI_2$의 경우 타 광도전체 물질(a-Se, a-Si, Ge, etc)등에 비해 X선 민감도가 우수하며, 낮은 인가전압에서 구동이 용이한 특성을 가지고 있다. 이러한 특징을 바탕으로 본 연구에서는 HgI2 (Mercury Iodide) 기반의 평판형 디지털 방사선 광도전체 필름을 두께에 따른 구현에 관한 연구를 수행하였다. 본 연구에서는 기존의 PVD(Physical Vapor Deposition)방법의 두꺼운 대면적 필름제조가 어려운 문제점을 해결하기 위해 Screen printing 방법을 사용하였다. 바인더의 종류로는 PVB (Polyvinylbutyral)와 DGME (Diethylene Glycol Monobutyl Ether)와 계면활성제 역할을 하는 DGMEA (Diethylene Glycol Monobutyl Ether Acetate)로 제작하는 바인더를 사용하여 Screen Printing법을 이용하여 각각의 다른 두께를 가지는 다결정의 HgI2 (Mercury Iodide) 필름을 제작하였다. 제작된 필름의 전기적 특성을 dark current, X-선 sensitivity와 SNR(Signal to -Noise Rate) 등을 측정하여 정량적으로 평가 하였다. 그 결과 DG계 200um의 근사하게 제작한 HgI2 (Mercury Iodide) 필름의 전기적특성이 가장 좋게 측정되었다. 얻어진 결과로 볼 때 HgI2 기반의 의료용 광도전체 필름은 기존의 a-Se(Amnorphous seleinum: a-se)를 이용한 디지털 방사선 광도전체 필름의 대체 적용에 대해 충분한 가능성을 보였다.

  • PDF

식품중 불법함유된 발기부전치료제 성분 검출을 위한 동시분석법 연구 (Simultaneous Identification/Determination System for Sildenafil, Homosildenafil, Vardenafil and Tadalafil as Adulterants in Foods)

  • 장재희;박건상;박혜경;구용의;최윤주;황인경;김대병
    • 한국식품위생안전성학회지
    • /
    • 제18권4호
    • /
    • pp.195-201
    • /
    • 2003
  • 본 연구에서는 국내 ${\cdot}$ 외에서 유통되는 건강관련식품 중 성기능 개선 및 효과에 대하여 광고 ${\cdot}$ 판매하고 있는 제품들에 대하여 최근 의약품으로 허가된 발기부전치료제인 sildenafil, vardenafil, tadalafil 및 sildenafil의 유사물질인 homosildenafil을 대상으로 정성과 정량을 위한 동시분석법을 개발하고 유통 제품 중의 함량을 분석하여 함유 실태를 파악하고자 하였다. 네 가지 성분을 확인할 수 있는 TLS와 LC/MS 분석방법을 개발하였으며, LC/PDA를 사용한 동시 정량분석법을 개발하고, 건강보조식품 등 건강관련 식품중 sildenafil 등 4종 물질에 대해 총 35개의 시료를 분석한 결과 sildenafil이 7종에서 0.4 mg/g~360.9 mg/g, homosildenafil이 7종에서 2.2 mg/g~336.0 mg/g, tadalafid이 2종에서 각각 19.2mg/g, 429.3mg/g로 검출되었으며, 본 여구에서 개발한 동시분석법을 유통식품에 적용 가능하였다.

변형근치유방절제술 환자의 Ion chamber 변화에 따른 디지털 흉부 영상의 화질 평가 (Evaluation of Image Quality for Diagnostic Digital Chest Image Using Ion Chamber in the Total Mastectomy)

  • 이진수;고성진;강세식;김정훈;박형후;김동현;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제13권3호
    • /
    • pp.204-210
    • /
    • 2013
  • 변형근치유방절제술을 시행한 환자는 일반 여성에 비해 수술로 인한 양측 유방의 두께 차이가 나타나게 되고 이에 따른 감약 차가 생기게 된다. 이에 본 연구는 디지털 영상 특성평가의 객관적인 기준이 되는 MTF를 측정하여 변형근치유방절제술을 시행한 환자들의 흉부촬영에서 적합한 Ion chamber 조합의 기준을 제시하고자 하였다. 디텍터에 위치한 chamber에 좌측 1, 우측 2, 가운데 3으로 번호를 지정하고 엣지팬텀을 부착하여 실험 영상을 획득하였다. 획득한 영상의 해상력 특성 평가는 Matlab(R2007a)를 이용하여 50% MTF 공간주파수의 해상력 평가와 흡수선량을 측정하였다. 실험결과에서 1+3과 2+3조합의 평균 노출조건, 공간주파수, 흡수선량은 각각 2.745 mAs, 1.925 lp/mm, 0.668 mGy로 다른 조합과 비교하여 적은 선량으로 높은 해상력 특성과 높은 DQE를 나타내었다. 따라서 변형근치유방절제술을 시행한 환자의 디지털 흉부영상의 촬영에서는 본 연구에서 제시하는 chamber 조합은 피폭선량 감소와 영상 화질의 향상에 대한 보상이 가능하여 향후 임상에서 적용 및 활용 가능한 chamber 기준이 될 것으로 사료된다.

6 MV 광자선과 6 MeV 전자선 하에서 TLD 기판 위에 얹힌 금속 박막의 효과 (The Effects of Metal Plate loaded on TLD chip in 6 MV Photon and 6 MeV Electron Beams)

  • Kim, Sookil;Byungnim Min
    • 한국의학물리학회지:의학물리
    • /
    • 제10권1호
    • /
    • pp.41-46
    • /
    • 1999
  • 본 실험은 의료용 가속기로부터 나오는 6MV 광자선과 6 MeV 전자선을 고체 팬텀위의 LiF 열형광 선량계 (TLD-l00)에 쪼여서 수행하였다. TLD-l00의 방사선 반응감도를 증가시키기 위해 TLD-l00 기판 (표면적 3.2 $\times$ 3.2 $\textrm{mm}^2$) 위에 같은 면적의 금속박막 (주석 혹은 금)을 얹어서 실험하였다. SSD l00cm, 방사선장의 크기 10$\times$10 $\textrm{cm}^2$의 조건 하에서 표면 흡수선량을 측정하였다. 측정결과 각 금속들로 인하여 TLD-l00 의 신호강도가 증강된 것이 관측되었다. 그리고 표면 흡수선량이 방사선량에 따라서 매우 선형적인 값을 가지는 것으로 나타났다 .6 MV 광자선의 경우 1 mm 의 금속박막을 TLD-l00 에 얹은 결과 표면 흡수선량이 각 각 14%, 56% 증가되었다 .6MeV의 전자선의 경우에는 금박막은 TL 반응감도가 13% 증가되었으나 주석의 경우에는 전혀 변화가 없었다. 금속박막을 얹은 TLD-l00의 방사선량 반응감도는 금속박막의 전자 입자밀도에 따라 증가하는 것으로 관측되었다. 이것은 TLD-l00보다 큰 전자밀도를 가진 부가물질(금속박막 )로부터 TLD-l00으로 산란전자가 유입되는 데 기인하는 것으로 보인다. 이 결과로부터 금속박막을 얹은 TL 선량계가 치료광자선용 증폭 선량계로서의 역할을 할 수 있을 것임을 시사한다. 즉 금속박막으로 인해서 TLD-l00 의 방사선 량 반응감도가 증가되었으므로 높은 감도의 보다 작은 TL 선량계의 개발이 가능하게 되었다.

  • PDF

THE NONDESTRUCTIVE MEASUREMENT OF THE SOLUBLE SOLID AND ACID CONTENTS OF INTACT PEACH USING VIS/NIR TRANSMITTANCE SPECTRA

  • Hwang, I.G.;Noh, S.H.;Lee, H.Y.;Yang, S.B.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.210-218
    • /
    • 2000
  • Since the SSC(soluble solid contents) and titratable acidity of fruit are highly concerned to the taste, the need for measuring them by non-destructive technology such as NIR(Visual and Near-infrared) spectroscopy is increasing. Specially, in order to grade the quality of each fruit with a sorter at sorting and packing facilities, technologies for online measurement satisfying the tolerance in terms of accuracy and speed should be developed. Many researches have been done to develop devices to measure the internal qualities of fruit such as SSC, titratable acidity, firmness, etc. with the VIS(Visual)/NIR(Near Infrared) reflectance spectra. The distributions of the SSC, titratable acidity, firmness, etc. are different with respect to the position and depth of fruit, and generally the VIS/NIR light can interact with fruit in a few millimeters of pathlength, and it is very difficult to measure the qualities of inner flesh of fruit. Therefore, to measure the average concentrations of each quality factor such as SSC and titratable acidity with the reflectance-type NIR devices, the spectra of fruit at several positions should be measured. Recently, the interest about the transmittance-type VIS/NIR devices is increasing. NIR light can penetrate through the fruit about 1/10-1/1,000,000 %. Therefore, very intensive light source and very sensitive sensor should be adopted to measure the transmitted light spectra of intact fruit. The ultimate purpose of this study was to develop a device to measure the transmitted light spectra of intact fruit such as apple, pear, peach, etc. With the transmittance-type VIS/NIR device, the feasibility of measurement of the SSC and titratable acidity in intact fruit cultivated in Korea was tested. The results are summarized as follows; A simple measurement device which can measure the transmitted light spectra of intact fruit was constructed with sample holder, two 500W-tungsten halogen lamps, a real-time spectrometer having a very sensitive CCD array sensor and optical fiber probe. With the device, it was possible to measure the transmitted light spectra of intact fruit such as apple, pear and peach. Main factors affecting the intensity of transmitted light spectra were the size of sample, the radiation intensity of light source and the integration time of the detector. Sample holder should be designed so that direct light leakage to the probe could be protected. Preprocessing method to the raw spectrum data significantly influenced the performance of the nondestructive measurement of SSC and titratable acidity of intact fruit. Representative results of PLS models in predicting the SSC of peach were SEP of 0.558 Brix% and R2 of 0.819, and those in predicting titratable acidity were SEP of 0.056% and R2 of 0.655.

  • PDF

방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구 (A Study on Chest X-ray Using Ancillary Device for Child Radiography)

  • 이도병;이소미;최현우;김종기;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권1호
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.

저준위 토양시료를 이용한 콤프턴 연속체 억제의 측정 및 몬테카롤로 시뮬레이션 평가 (Measurement and Monte Carlo Simulation evaluation of a Compton Continuum Suppression with low level soil Sample)

  • 장은성;이효영
    • 한국방사선학회논문지
    • /
    • 제12권2호
    • /
    • pp.123-131
    • /
    • 2018
  • 본 연구는 점 선원인 $^{60}Co$, $^{137}Cs$ 및 혼합부피선원을 이용하여 피크 대 컴프턴 비율, 연속체 배경 스펙트럼을 감소시키기 위해 저 에너지 peak부터 고 에너지 peak에서 측정된 측정치와 PENELOPE와 비교하였다. 또한, 저에너지 부근에서의 변화를 통해 후방산란, 컴프턴 단(compton edge)의 효율 변화를 PENELOPE와 비교하였다. 혼합부피 선원에서 나온 결과를 토양시료에 적용하여 억제와 비 억제(unsuppressed)모드에서 토양시료의 최소검출한계치가 얼마큼 감소하였는지 확인하고자 한다. $^{60}CO$(1,173 keV)의 저에너지 영역의 컴프턴 억제가 상당히 되었으며, $^{137}Cs$(661 keV) 피크에 대한 Compton edge의 RF는 2.8이다. 특히, $^{60}Co$ 선원은 1,173.2keV와 1,332.5 keV의 coincidence 감마선을 방출하므로 컴프턴 억제는 대략 21% 감소하였다. 60Co 선원에서 방출되는 1,173keV와 1,332keV의 compton edge의 RF는 3.2, 3.4였으며 피크대 컴프턴 edge비율은 8:1로 향상되었다. 그리고, PENELOPE와 비교했을 때 불확도는 2% 이내로 잘 일치하였다. Compton unsuppressed 모드에서 661 keV, 1,173 keV 및 1,332 keV의 MDA 값은 각각 0.535, 0.173 및 0.136Bq/kg이었으나, Compton suppressed 모드에서는 0.121, 0.00826 및 0.00728B/kg로 감소하였다. 따라서, Compton suppres sed는 배후방사능과 검출기 자체에 함유된 방사능을 줄일 수 있었다.

X선을 이용한 면적선량계의 교정 연구 (Calibration Examination of Dose Area Product Meters using X-ray)

  • 정재은;정홍문;원도연;권대철
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.37-42
    • /
    • 2017
  • 엑스선을 이용한 방사선검사에서 전리함 방식의 면적선량계를 이용하여 흡수선량과 면적선량을 측정하고, 교정계수를 측정하였다. 간접선량측정법은 엑스선발생장치의 방사부에 검출기를 설치, 측정치를 조사부위에서의 선량으로 산출하였다. 교정계수를 산출하기 위해 사용된 기기는 엑스선 발생장치로 (DK-550R/F, DongKang Medical Co. Ltd., Seoul, Korea)를 이용하였고, 교정계수를 위한 교정방법은 면적선량계와 교정선량계를 연결하고 관전압 70 kV, 관전류 500 mA, 0.158 sec로 79 mAs 조건을 이용하였다. 면적선량계 (PD-8100, Toreck Co. Ltd. Japan)을 이용하였고, 기준선량계는 반도체검출기 (DOSIMAX plus A, Scanditronix, $Wellh{\ddot{o}}fer$, Germany)를 이용하였다. 면적선량계를 전리함의 다중조리개 전면에 설치 후 정확한 선량 측정을 위해 기준선량계를 이용하여 선량계의 교정계수를 구하였다. 실험적으로 노출하여 측정된 값과 교정선량계에서 나온 값에 각각의 교정계수를 곱하여 산출하였다. 교정계수는 1.045로 산출되었다. 전리함 방식의 면적선량계에서 관전압에 따른 교정계수를 산출하기 위해 흡수선량과 면적선량을 구하여 교정상수를 산출하였다. 면적선량계의 교정계수를 구하여 정확한 면적선량을 산출하여야 한다.