• Title/Summary/Keyword: radiation degradation

Search Result 290, Processing Time 0.029 seconds

The Effects on the Crystal Structure of LDPE thin film exposed Radiation (방사선이 LDPE박막의 결정구조에 미치는 영향)

  • 강전홍;김한준;유광민;박강식;김종석;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.181-184
    • /
    • 2000
  • LDPE pelet is distilled to make 0.5 Wt% solutions and fabricated as LDPE thin film by dropping the solution onto glass substrate, and then annealed the film to be crystalline. The structure is observed as crystalline regions and non-crystalline regions. The crystalline region is exposed at radiation and as the result, there appeared degradation at the total region of the crystal structure. It is considered therefore that radiation exposure at the crystal structure is badly effected on insulation property and lifetime of materials.

  • PDF

Structural Changes in $^{60}Co\;\gamma-Ray$ Irradiated Poly(vinylidene fluoride) ($^{60}Co\;\gamma$-선 조사에 의한 Poly(Vinylidene fluoride)의 구조적 변화)

  • Lee, Chung;Kim, Ki-Yup;Kim, Pyeong-Jong;Kim, Jin-Ah;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.437-440
    • /
    • 2004
  • The radiation-induced changes taking place in poly(vinylidene fluoride)(PVDF) exposed to $^{60}Co\;\gamma-ray$ irradiation were investigated in correlation with the applied doses. Samples were irradiated in air at room temperature by $^{60}Co\;\gamma-ray$ to doses in the range of 200 to 1000 kGy. Various properties of the irradiated PVDF were studied using nm, differential scanning calorimetry(DSC) and gel fraction. $^{60}Co\;\gamma-ray$ irradiation was found to induce changes in chemical, thermal, structural properties of PVDF and such changes vary depending on the radiation dose.

  • PDF

Electrical Characteristics of IGBT for Gate Bias under $\gamma$ Irradiation (게이트바이어스에서 감마방사선의 IGBT 전기적 특성)

  • Lho, Young-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.1-6
    • /
    • 2009
  • The experimental results of exposing IGBT (Insulated Gate Bipolar Transistor) samples to gamma radiation source show shifting of threshold voltages in the MOSFET and degradation of carrier mobility and current gains. At low total dose rate, the shift of threshold voltage is the major contribution of current increases, but for more than some total dose, the current is increased because of the current gain degradation occurred in the vertical PNP at the output of the IGBTs. In the paper, the collector current characteristics as a function of gate emitter voltage (VGE) curves are tested and analyzed with the model considering the radiation damage on the devices for gate bias and different dose. In addition, the model parameters between simulations and experiments are found and studied.

Radiation Effect to Each Phase of Morphology on a Low Density Polyethylene Irradiated to $C_0^{60}\gamma$. ray (Co$^{60}\gamma$.gamma.선이 저밀도 폴리에티렌의 각상에 미치는 조사효과)

  • 김봉흡;강도열;김재환
    • 전기의세계
    • /
    • v.23 no.5
    • /
    • pp.54-60
    • /
    • 1974
  • Proposals were mode on how to differentiate radiation effects in morphological phases of polyethylene and discussions were developed with the results obtained on a low density polyethylene, SOCAREX, specified by number average molecular weight; overbar Mn=5,400, density; 0.92, and degree of branch; 3.4/100 carbon atom, which was irradiated to Co$^{60}$ .gamma. ray at the dose rate of 0.5 Mrad/hr in ambient temperature under the pressure of 10$^{-5}$ Torr. or 1 atm. respectively. The effect to crystalline phase in possibly deduced from dose dependent variation of relative area between (110) and (200) peaks on X ray diffraction spectrum and that, the effects to amorphous phase can be understood through dose dependent relaxation behaviours of .betha. peak on internal friction characteristics of the specimen. The results obtained thus far indicate that, in crystalline phase, relative crystallinity shows a rather rapid decrease up to 20 Mrad with increasing dose, however, little change of crystallinity can be observed in the region between 20-200 Mrad, and degradation appears to be more predominant than crosslinking up to 60 Mrad. While in amorphous phase the indication also shows that degradation is only predominant up to 20 Mrad. Furthermore several correlations can be seen with amenable explanation between dose dependent behaviours observed in both phases.

  • PDF

A Theoretical Approach on the Migration of a Chelating Radionuclide in Porous Medium (다공성 매질에서의 착화하는 방사성핵종의 이동에 대한 이론적 접근)

  • Baik, Min-Hoon;Lee, Kun-Jai
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.2
    • /
    • pp.49-59
    • /
    • 1992
  • A new model was developed in order to investigate the effects of chelating agents on the migration of a radionuclide in the form of ion or chelate. The migration behavior of the chelated radionuclide was analyzed by formulating a convective-dispersion transport equation which included a degradation of chelating agent and chelated radionuclide. The mathematical model was analytically solved and checked with the existing retardation factor. The results show that the migration velocity of the chelated radionuclide was much faster than the ionic one due to the decreased retardation. Therefore, it was concluded that a new remedial action should be developed to reduce the generation and release of chelating agents from the nuclear power plant into the environment.

  • PDF

Physicochemical Properties and Antioxidant Effects of Fucoidans Degraded by Hydrogen Peroxide under Electron Beam at Various Irradiation Doses

  • Jeong, Gyeong-Won;Choi, Yoo-Sung
    • Applied Chemistry for Engineering
    • /
    • v.33 no.3
    • /
    • pp.322-327
    • /
    • 2022
  • Fucoidans were degraded by hydrogen peroxide under the electron beam (2.5 MeV) with various radiation doses (5 kGy, 10 kGy, 15 kGy, and 20 kGy) at room temperature. The degradation property was analyzed with a gel permeation chromatography (GPC-MALLS) method. An average molecular weight of fucoidan decreased from 99,956 at the irradiation dose of 0 kGy to 6,725 at the irradiation dose of 20 kGy. The solution viscosity of fucoidans showed a similar pattern to the molecular weight change. The number of chain breaks per molecule (N) increased with increasing the irradiation dose and concentration of hydrogen peroxide. The radiation yield of scission value markedly increased with increasing the irradiation dose up to 15 kGy. Also a 10% hydrogen peroxide concentration was more efficient than that of 5%. The structures of degraded fucoidan samples were studied with Fourier transform infrared spectroscopy (FT-IR). The results showed that the degradation process did not significantly change the chemical structure or the content of sulfate group. The sulfur content of each sample was determined with an Elemental Analyzer. With increasing the concentration of hydrogen peroxide, the ratios of sulfur/carbon, hydrogen/carbon, and nitrogen/carbon slightly decreased. The antioxidant activities of fucoidans were investigated based on hydroxyl radical scavenging activities. The ability of fucoidan to inhibit the hydroxyl radical scavenging activity was depended on its molecular weight.

Development and Evaluation of a Thimble-Like Head Bolus Shield for Hemi-Body Electron Beam Irradiation Technique

  • Shin, Wook-Geun;Lee, Sung Young;Jin, Hyeongmin;Kim, Jeongho;Kang, Seonghee;Kim, Jung-in;Jung, Seongmoon
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.3
    • /
    • pp.152-157
    • /
    • 2022
  • Background: The hemi-body electron beam irradiation (HBIe-) technique has been proposed for the treatment of mycosis fungoides. It spares healthy skin using an electron shield. However, shielding electrons is complicated owing to electron scattering effects. In this study, we developed a thimble-like head bolus shield that surrounds the patient's entire head to prevent irradiation of the head during HBIe-. Materials and Methods: The feasibility of a thimble-like head bolus shield was evaluated using a simplified Geant4 Monte Carlo (MC) simulation. Subsequently, the head bolus was manufactured using a three-dimensional (3D) printed mold and Ecoflex 00-30 silicone. The fabricated head bolus was experimentally validated by measuring the dose to the Rando phantom using a metal-oxide-semiconductor field-effect transistor (MOSFET) detector with clinical configuration of HBIe-. Results and Discussion: The thimble-like head bolus reduced the electron fluence by 2% compared with that without a shield in the MC simulations. In addition, an improvement in fluence degradation outside the head shield was observed. In the experimental validation using the inhouse-developed bolus shield, this head bolus reduced the electron dose to approximately 2.5% of the prescribed dose. Conclusion: A thimble-like head bolus shield for the HBIe- technique was developed and validated in this study. This bolus effectively spares healthy skin without underdosage in the region of the target skin in HBIe-.

Development of underwater 3D shape measurement system with improved radiation tolerance

  • Kim, Taewon;Choi, Youngsoo;Ko, Yun-ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1189-1198
    • /
    • 2021
  • When performing remote tasks using robots in nuclear power plants, a 3D shape measurement system is advantageous in improving the efficiency of remote operations by easily identifying the current state of the target object for example, size, shape, and distance information. Nuclear power plants have high-radiation and underwater environments therefore the electronic parts that comprise 3D shape measurement systems are prone to degradation and thus cannot be used for a long period of time. Also, given the refraction caused by a medium change in the underwater environment, optical design constraints and calibration methods for them are required. The present study proposed a method for developing an underwater 3D shape measurement system with improved radiation tolerance, which is composed of commercial electric parts and a stereo camera while being capable of easily and readily correcting underwater refraction. In an effort to improve its radiation tolerance, the number of parts that are exposed to a radiation environment was minimized to include only necessary components, such as a line beam laser, a motor to rotate the line beam laser, and a stereo camera. Given that a signal processing circuit and control circuit of the camera is susceptible to radiation, an image sensor and lens of the camera were separated from its main body to improve radiation tolerance. The prototype developed in the present study was made of commercial electric parts, and thus it was possible to improve the overall radiation tolerance at a relatively low cost. Also, it was easy to manufacture because there are few constraints for optical design.

Photocatalytic Degradation of Methyl tert-Butyl Ether (MTBE): A review

  • Seddigi, Zaki S.;Ahmed, Saleh A.;Ansari, Shahid P.;Yarkandi, Naeema H.;Danish, Ekram;Oteef, Mohammed D.Y.;Cohelan, M.;Ahmed, Shakeel;Abulkibash, Abdallah M.
    • Advances in environmental research
    • /
    • v.3 no.1
    • /
    • pp.11-28
    • /
    • 2014
  • Advanced oxidation processes using UV and catalysts like $TiO_2$ and ZnO have been recently applied for the photocatalytic degradation of MTBE in water. Attempts have been made to replace the UV radiation by the solar spectrum. This review intends to shed more light on the work that has been done so far in this area of research. The information provided will help in crystallizing the ideas required to shift the trend from UV photocatalysis to sunlight photocatalysis. The careful optimization of the reaction parameters and the type of the dopant employed are greatly responsible for any enhancement in the degradation process. The advantage of shifting from UV photocatalysts to visible light photocatalysts can be observed when catalysts like $TiO_2$ and ZnO are doped with suitable metals. Therefore, it is expected that in the near future, the visible light photocatalysis will be the main technique applied for the remediation of water contaminated with MTBE.

Radiation-induced Degradation and Immune Toxicity Reduction of Endosulfan (감마선 조사에 의한 endosulfan의 면역독성 저감)

  • Kim, Hyun-Joo;Kim, Tae-Hoon;Ham, Jun-Sang;Kim, Kee-Hyuk;Jo, Cheo-Run
    • Food Science and Preservation
    • /
    • v.19 no.3
    • /
    • pp.451-454
    • /
    • 2012
  • Endosulfan is an organochlorine pesticide that is widely used throughout the world for higher agricultural production. Its extreme toxicity, however, has caused health and environment concerns that have led to an interest in detoxification. In this study, the radiolytic degradation of endosulfan was investigated. Endosulfan in methanol solution (100 ppm) was irradiated at 0, 10, 30, and 50 kGy, and subsequent changes in immune toxicity and degradation of endosulfan were observed. The concentration of endosulfan that was used in this experiment did not affect the cell proliferation. The irradiation of endosulfan decreased the production of NO, indicating a decrease in the immune toxicity of endosulfan by irradiation. The concentration of endosulfan was significantly reduced by irradiation in a dose-dependent manner. The results suggest that gamma irradiation can degrade endosulfan and can reduce its immune toxicity.