• Title/Summary/Keyword: radiation cooling

Search Result 388, Processing Time 0.028 seconds

Study on Analysis Technique Comparison and Evaluation of High Thermal Conductivity Concrete with Magnetite Aggregates and Steel Powder (자철광 및 철분말을 혼입한 고열전도 콘크리트의 열전도 평가 및 해석기법 비교에 대한 연구)

  • Lee, Hack-Soo;Kim, Min-Kyu;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.315-321
    • /
    • 2014
  • Concrete as a construction material is widely used in nuclear vessel and plant for excellent radiation shielding. However the isolation characteristics in concrete may affect adversely in the case of fire and melt-down in nuclear vessel since temperature cooling down is very difficult from outside. This study is for development of high thermal conductive concrete, and its mechanical and thermal properties are evaluated. Magnetite aggregates with volume ratio of 42.3% (maximum) and steel powder of 1.5% are replaced with normal aggregates and thermal properties are evaluated. Thermal conductivity little increases by 30% addition of magnetite but rapidly increases afterwards. Finally thermal conductivity is magnified to 2.5 times in the case of 42.3% addition of magnetite. Steel powder has a positive effect on high thermal conduction to 106~113%. Several models for thermal conduction like ACI, DEMM, and MEM are compared with test results and they are verified to reasonably predict the thermal conductivity with increasing addition of magnetite aggregates and steel powder.

Optimum Management of Greenhouse Environment by the Shading Coat and Two-fluid Fogging System in Summer Season (차광제와 이류체 포그시스템을 이용한 고온기 시설내 환경관리)

  • Kim, Sung Eun;Lee, Jae Eun;Lee, Sang Don;Kim, Hak Sun;Chun, Hee;Jeong, Woo Ri;Lee, Moon Haeng;Kim, Young Shik
    • Journal of Bio-Environment Control
    • /
    • v.24 no.1
    • /
    • pp.34-38
    • /
    • 2015
  • This research was conducted to establish efficient methods to overcome high temperature and low humidity with light selective shading agent and two-fluid fogging system in greenhouses in hot season. There were four experimental treatments; not treated (Non), fogging by two-fluid fogging system (Fog), spraying onto the greenhouse surface with shading coating agent (Coat), and using fogging and coating together (F&C). The amount of solar radiation entered into the greenhouses was higher in Non, and then Fog, Coat, and F&C in descending order. Fog was more efficient to lower the air temperature and also raise relative humidity than Coat treatment. The crop temperature was about $6^{\circ}C$ higher in Control than the other treatments. F&C revealed as the most efficient method to control the environment inside the greenhouse, but fogging system seemed to be more economic. In stand-alone greenhouses spraying coating agent may be the appropriate choice because of their structural limitations, mainly eave height.

Seasonal Variability of Thermal Structure and Heat Flux in the Juam Reservoir (주암호의 계절별 수온 구조와 열수지 변화)

  • Sun, Youn-Jong;Cho, Cheol;Kim, Byong-Chun;Huh, In-Aa;Yoon, Jun-Heon;Chang, Nam-Ik;Cha, Sung-Sik;Cho, Yang-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.3 s.104
    • /
    • pp.277-285
    • /
    • 2003
  • Temperature profiles were observed to understand seasonal variation of thermal structures in the Juam reservoir from March 2000 to May 2001. Heat flux which affects thermal structures was calculated by observed water temperature and meteorological data. Temperature became homogeneous vertically by convection due to the surface cooling in winter. Maximum heat loss through the surface (109.45W/$m^2$) occurred in December. There was a horizontal gradient of water temperature in winter. The temperature was $3^{\circ}C$ at upstream and $5^{\circ}C$ near the dam. The surface temperature increased by the increase of solar radiation in spring and summer. Maximum heat gained through the surface was 101.95 W/$m^2$ in July. Maximum surface temperature was $29^{\circ}C$ in August, whereas the bottom water was $7^{\circ}C.$ Surface mixed layer became thicker and its temperature decreased by surface heat loss in fall and winter.

Assessment on Thermal Transmission Property of Wall Through a Scaled Model Test (축소모형 실험을 통한 벽체의 열관류 측정)

  • Chang, Yoon-Seong;Kim, Sejong;Shim, Kug-Bo;Lee, Sang-Joon;Han, Yeonjung;Park, Yonggun;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.884-889
    • /
    • 2015
  • Appropriate evaluation of thermal insulation property of structural member and valid control of cooling/heating energy are important for improving building's energy efficiency. The typical heating system of house in Korea is the floor heating one. The radiation heating system is not only appropriate to climate and geographic conditions of Korea, but also advantageous to provide emotional comfort by the warm feeling of floor. Based on living conditions in Korea, scaled models of the wooden house and concrete house were designed. The ceiling was made of styrofoam insulation and the four sided walls and bottom were made of plywood and concrete, respectively. The floor was heated by heating film. Indoor vertical temperature distributions by floor heating system were measured by thermocouple, and surface temperatures on walls were measured by infrared thermography. Also, thermal insulation property of wooden wall was evaluated to build database for improving energy efficiency of wooden building. It is expected that collected data during tests of various types of floor and wall composition could be referenced for evaluating thermal environment of actual conditions of houses.

Experimental Investigation of Variable Emittance Material Based on (La, Sr)MnO3 ((La, Sr)MnO3을 이용한 가변 방사율 소재에 관한 연구)

  • Han, Sunwoo;Choi, Bongsu;Song, Tae-Ho;Kim, Sun Jin;Lee, Bong Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.583-590
    • /
    • 2013
  • Variable emittance radiators can be used in a thermal management system in space because their total emittance changes depending on the temperature of the system. When the temperature of the system decreased, the emittance also decreased so as to minimize the heat loss to the environment. In contrast, when the temperature of the system increased, the emittance also increased such that radiation cooling could occur. Thermochromic materials, whose emittance is a function of the temperature, are often used in variable emittance radiators because no additional parts are needed. In this study, we fabricated a variable-emittance coating by using a sol-gel method based on LSMO ($La_{1-x}Sr_xMnO_3$) and experimentally characterized the emittance change with respect to temperature. Furthermore, we also examined the stability of LSMO film in space environments by exposing it to extremely low pressure and temperature.

Validation of a New Design of Tellurium Dioxide-Irradiated Target

  • Fllaoui, Aziz;Ghamad, Younes;Zoubir, Brahim;Ayaz, Zinel Abidine;Morabiti, Aissam El;Amayoud, Hafid;Chakir, El Mahjoub
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1273-1279
    • /
    • 2016
  • Production of iodine-131 by neutron activation of tellurium in tellurium dioxide ($TeO_2$) material requires a target that meets the safety requirements. In a radiopharmaceutical production unit, a new lid for a can was designed, which permits tight sealing of the target by using tungsten inert gaswelding. The leakage rate of all prepared targets was assessed using a helium mass spectrometer. The accepted leakage rate is ${\leq}10^{-4}mbr.L/s$, according to the approved safety report related to iodine-131 production in the TRIGA Mark II research reactor (TRIGA: Training, Research, Isotopes, General Atomics). To confirm the resistance of the new design to the irradiation conditions in the TRIGA Mark II research reactor's central thimble, a study of heat effect on the sealed targets for 7 hours in an oven was conducted and the leakage rates were evaluated. The results show that the tightness of the targets is ensured up to $600^{\circ}C$ with the appearance of deformations on lids beyond $450^{\circ}C$. The study of heat transfer through the target was conducted by adopting a one-dimensional approximation, under consideration of the three transfer modes-convection, conduction, and radiation. The quantities of heat generated by gamma and neutron heating were calculated by a validated computational model for the neutronic simulation of the TRIGA Mark II research reactor using the Monte Carlo N-Particle transport code. Using the heat transfer equations according to the three modes of heat transfer, the thermal study of I-131 production by irradiation of the target in the central thimble showed that the temperatures of materials do not exceed the corresponding melting points. To validate this new design, several targets have been irradiated in the central thimble according to a preplanned irradiation program, going from4 hours of irradiation at a power level of 0.5MWup to 35 hours (7 h/d for 5 days a week) at 1.5MW. The results showthat the irradiated targets are tight because no iodine-131 was released in the atmosphere of the reactor building and in the reactor cooling water of the primary circuit.

Time-dependent Evolution of Accretion Disk Mass in a Black Hole Microquasar Candidate A0620-00 (블랙홀 마이크로퀘이사 후보 A0620-00의 강착원반 질량의 시간적 진화)

  • Kim, Soon-Wook
    • Journal of the Korean earth science society
    • /
    • v.29 no.7
    • /
    • pp.579-585
    • /
    • 2008
  • The time-dependent evolution of disk mass for outburst limit cycle in a black hole microquasar is calculated based on the non-linear hydrodynamic model of thermally unstable accretion disk. The physical parameters such as black hole mass, disk size and mass transfer rate are adopted to reproduce the historical 1975 outburst observed in a prototype black hole X-ray nova A0620-00. The time-dependent effect of irradiation from the central hot region to the disk is considered in two ways: direct irradiation and indirect irradiation reflected from hot accretion flow above the disk. The accretion disk thermal instability model can account for the bolometric luminosity appropriate to typical characteristics of system luminosity observed in X-ray transients during the whole cycle of the outburst evolution. The maximum mass of the accretion disk, ${\sim}4.03{\times}10^{24}g$, is achieved at the ignition of an outburst, and the minimum value, ${\sim}8.54{\times}10^{23}g$, is reached during the cooling decay to quiescence. The disk mass varies ${\sim}5$ times during outburst limit cycle.

Structural Design and Thermal Analysis of a Module Coil for a 750 kW-Class High Temperature Superconducting Generator for Wind Turbine (풍력 터빈용 750 kW 급 고온초전도 발전기 모듈의 코일 구조 설계 및 열 해석)

  • Tuvdensuren, Oyunjargal;Go, Byeong-Soo;Sung, Hae-Jin;Park, Min-Won
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.2
    • /
    • pp.33-40
    • /
    • 2019
  • Many companies have tried to develop wind power generators with a larger capacity, smaller size and lighter weight. High temperature superconducting (HTS) generators are more suitable for wind power systems because they can reduce volume and weight compared with conventional generators. However, the HTS generator has problems such as huge vacuum vessel and the difficulty of repairing the HTS field coils. These problems can be overcome through the modularization of the HTS field coil. The HTS module coil require a current leads (CLs) for deliver DC current, which causes a large heat transfer load. Therefore, CLs should be designed optimally for reducing the conduction and Joule heat loads. This paper deals with a structural design and thermal analysis of a module coil for a 750 kW-class HTS generator. The conduction and radiation heat loads of the module coils were analysed using a 3D finite element method program. As a result, the total thermal load was less than the cooling capacity of the cryo-cooler. The design results can be effectively utilized to develop a superconducting generator for wind power generation systems.

Intercomparison of Shortwave Radiative Transfer Models for Aerosol-laden Atmospheres (에어러솔 대기에서 단파 영역에서의 복사전달모델들의 상호비교)

  • Yoo, Jung-Moon;Jeong, Myeong-Jae;Lee, Kyu-Tae;Kim, Jhoon;Rhee, Ju-Eun;Hur, Young-Min;Kim, Bo-Mi;Lee, Yun-Gon;Lee, Jae-Hwa;Yoon, Jong-Min;Lee, Won-Hak
    • Journal of the Korean earth science society
    • /
    • v.29 no.2
    • /
    • pp.128-139
    • /
    • 2008
  • Intercomparison among the three radiative transfer models (RTMs) which have been used in the studies for COMS, was carried out on the condition of aerosol-laden atmospheres. Also the role of aerosols in the atmospheric radiation budget was analyzed. The results (hereafter referred to as H15) from Halthore et al.'s study (2005) were used as a benchmark to examine the models. Aerosol Radiative Forcing (ARF) values from the three RTMs, calculated under two conditions of Aerosol Optical Thickness (AOT=0.08, 0.24), were systematically underestimated in comparison to H15 in the following shortwave components; 1) direct and diffuse irradiance at the surface, 2) diffuse upward fluxes at the surface and the top of the atmosphere, and 3) atmospheric absorbance. The ARF values for the direct and diffuse fluxes at the surface was $-10{\sim}-40Wm^{-2}$. The diffuse upward values became larger with increasing both AOT and Solar Zenith Angle (SZA). Diffuse upward/downward fluxes at the surface were more sensitive to the SZA than to the atmospheric type. The diffuse downward values increased with increasing AOT and decreasing SZA. The larger AOT led to surface cooling by exceeding the reduction of direct irradiance over the enhancement of diffuse one at the surface. The extinction of direct solar irradiance was due mainly to water vapor in tropical atmospheres, and to both ozone and water vapor in subarctic atmospheres. The effect of water vapor in the tropics was $3{\sim}4$ times larger than that of the ozone. The absorbance values from the three RTMs agree with those from H15 within ${\pm}10%$.

Estimation of the Required Number of Fan Coil Unit for Surplus Solar Energy Recovery of Greenhouse (온실의 잉여 태양에너지 회수용 FCU 소요대수 검토)

  • Yun, Sung-Wook;Choi, Man Kwon;Kim, Ha Neul;Kang, Donghyeon;Lee, Siyoung;Son, Jinkwan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.83-88
    • /
    • 2016
  • In this study, previously reported surplus solar energy-related study result and current status of fan coil unit (FCU) for cooling and heating installed in the current sites were briefly examined and then a method to determine the number of FCUs required to recover surplus solar energy was schematically proposed to provide basic data for researchers and technical engineers in this field. The maximum, mean, and minimum outside temperatures during the experiment period were about $28.2^{\circ}C$, $4.4^{\circ}C$, and $-11.5^{\circ}C$, respectively. The horizontal surface solar radiation level outside the greenhouse was in a range of $0.8-20.5MJ{\cdot}m^{-2}$ and mean and total solar radiation were $10.8MJ{\cdot}m^{-2}$ and $1,187.5MJ{\cdot}m^{-2}$. The mean temperature and relative humidity in the greenhouse during the daytime were in a range of 18.8-45.5 and 53.5-77.5%. The total surplus solar energy recovered from the greenhouse during the experiment period was approximately 6,613.4MJ, which could supplement about 6.7% of the total heating energy 98,600.2 MJ. In addition, the number of FCUs installed for heating varies case to case, although similar FCUs are used. Thus, it is necessary to study the installation height, orientation and installation distance as well as the appropriate number of FCUs from the efficient and economical viewpoints. The required numbers of FCUs for surplus solar energy recovery were 8.4-10.9units and 6.1-8.0units based on air mass and circular flow rate that passed through the FCUs. Considering calculation methods and the risks such as efficiency and use environments of FCUs, it was found that about nine units (one unit per $24m^3$ approximately) needed to be installed. The required number of FCUs for surplus solar energy recovery was around one unit per $24m^3$ approximately.