• 제목/요약/키워드: radiation attenuation

검색결과 265건 처리시간 0.025초

조파역내 오염물 이동특성 평가 실험 (Experiments for the Characteristic Evaluation of Pollutant Transport in Tidal Influenced Region)

  • 박건형;김기철;정성희;서경석
    • 방사선산업학회지
    • /
    • 제4권4호
    • /
    • pp.391-395
    • /
    • 2010
  • The characteristics for pollutant transport in tidal influenced area was investigated using tidal wave hydraulic scale model. Hydraulic scale model was composed of the tidal generator, attenuation area and channel. Also, wave height, current meter and conductivity meter were used with the measured instruments in hydraulic scale model. NaCl with a tracer was used to evaluate the advection phenomena under the different velocity profiles. The arrival time of the maximum concentration in the condition of the relatively fast velocity was measured about 30 seconds faster than ones in the conditions of low velocity. The measured concentrations of the tracer were shown in the detection points of the flow direction consecutively.

Nordic research and development cooperation to strengthen nuclear reactor safety after the Fukushima accident

  • Linde, Christian;Andersson, Kasper G.;Magnusson, Sigurdur M.;Physant, Finn
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.647-653
    • /
    • 2019
  • A comprehensive study of photon interaction features has been made for some alloys containing Pd and Ag content to evaluate its possible use as alternative gamma radiations shielding material. The mass attenuation coefficient (${\mu}/{\rho}$) of the present alloys was measured at various photon energies between 81 keV - 1333 keV utilizing HPGe detector. The measured ${\mu}/{\rho}$ values were compared to those of theoretical and computational (MCNPX code) results. The results exhibited that the ${\mu}/{\rho}$ values of the studied alloys are in same line with results of WinXCOM software and MCNPX code results at all energies. Moreover, Pd75/Ag25 alloy sample has the maximum radiation protection efficiency (about 53% at 81 keV) and lowest half value layer, which shows that Pd75/Ag25 has superior gamma radiation shielding performance among the compared other alloys.

An extensive investigation on gamma ray shielding features of Pd/Ag-based alloys

  • Agar, O.;Sayyed, M.I.;Akman, F.;Tekin, H.O.;Kacal, M.R.
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.853-859
    • /
    • 2019
  • A comprehensive study of photon interaction features has been made for some alloys containing Pd and Ag content to evaluate its possible use as alternative gamma radiations shielding material. The mass attenuation coefficient (${\mu}/{\rho}$) of the present alloys was measured at various photon energies between 81 keV-1333 keV utilizing HPGe detector. The measured ${\mu}/{\rho}$ values were compared to those of theoretical and computational (MCNPX code) results. The results exhibited that the ${\mu}/{\rho}$ values of the studied alloys are in the same line with results of WinXCOM software and MCNPX code results at all energies. Moreover, Pd75/Ag25 alloy sample has the maximum radiation protection efficiency (about 53% at 81 keV) and lowest half value layer, which shows that Pd75/Ag25 has superior gamma radiation shielding performance among the other compared alloys.

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

A Monochromatic X-Ray CT Using a CdTe Array Detector with Variable Spatial Resolution

  • Tokumori, Kenji;Toyofuku, Fukai;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.411-414
    • /
    • 2002
  • The CdTe semiconductor detector has a higher detection efficiency for x-rays and $\square$amma rays and a wider energy band gap compared with Si and Ge semiconductor detectors. Therefore, the size of the detector element can be made small, and can be operated at room temperature. The interaction between a CdTe detector and incident x-rays is mainly photoelectric absorption in the photon energy range of up to 100 keV. In this energy range, Compton effects are almost negligible. We have developed a 256 channel CdTe array detector system for monochromatic x-ray CT using synchrotron radiation. The CdTe array detector system, the element size of which is 1.98 mm (h) x 1.98 mm (w) x 0.5 mm (t), was operated in photon counting mode. In order to improve the spatial resolution, we tilted the CdTe array detector against the incident parallel monochromatic x-ray beam. The experiments were performed at the BL20B2 experimental hutch in SPring-8. The energy of incident monochromatic x-rays was set at 55 keV. Phantom measurements were performed at the detector angle of 0, 30 and 45 degrees against the incident parallel monochromatic x-rays. The linear attenuation coefficients were calculated from the reconstructed CT images. By increasing the detector angle, the spatial resolutions were improved. There was no significant difference between the linear attenuation coefficients which were corrected by the detector angle. It was found that this method was useful for improving the spatial resolution in a parallel monochromatic x-ray CT system.

  • PDF

폐암 환자에서 방사선치료가 세포성 면역반응에 미치는 영향 (The Effect of Radiation Therapy on Cellular Immune Response in Patients with Squamous Cell Lung Carcinoma)

  • 어수택;김철현;정연태;김용훈;박춘식;이희발;허승재
    • Tuberculosis and Respiratory Diseases
    • /
    • 제38권1호
    • /
    • pp.25-33
    • /
    • 1991
  • The immune staus is known to be decreased in malignant disease and radiation therapy (RT), used as a therapeutic tool, further decrease this-attenuated immune status. We measured the number of peripheral lymphocytes, its subsets and lymphoblast transformation for PPD, PHA, monoclonal antibodies including anti-CD3 and anti-CD2 before and after RT in 19 patients with squamous cell lung cancer to search the fine mechanism behind the RT-induced attenuation of lymphoblast transformtion for mitogens and antigen. The results were as follows; 1) The number of lymphocytes and its subsets decreased significantly after RT, but the percentages of lymhocyte subsets did not change aftr RT except interleukin-2 receptor positive T lymphocytes. 2) The function of lymphoctes, measured by lymphoblast tranformation for PHA and PPD, decrased after RT and the compositions of PBMC used for lymphoblast transformtion were not different before and after RT. 3) The mitosis of lymphocytes to anti-CD2 or anti-CD3 decreased significantly after RT. And IL-2 plus anti-CD3 increased the mitosis than that of anti-CD3 only after RT, but before RT there was no difference. In conclusion, we suggested the fine mechanism behind the RT-induced attenuation of immune response might be the dysfunction of lymphocytes in terms of impaired synthesis of IL-2 rather than the decrease of circulating lymphocyte numbers.

  • PDF

GSM 단말기에서 두부 팬텀 조건하의 방사 전력 최적화를 위한 단말기 구조에 관한 연구 (A Study on GSM Handset Structure for Radiation Power Optimization under Head Phantom)

  • 양부영;김정민;육종관
    • 한국전자파학회논문지
    • /
    • 제18권7호
    • /
    • pp.689-697
    • /
    • 2007
  • 본 논문에서는 폴더형 휴대 단말기에서 머리와 단말기가 인접해지는 통화 조건에서의 방사 전력을 향상시킬 수 있는 방법을 제시하였다. 향상된 방사 성능을 분석하기 위해 자유 공간에 EUT만 있을 경우와 머리 팬텀이 함께 있을 경우에 EUT의 TRP를 측정하였고 단말기의 구조 중 팬텀 조건에서의 TRP(Total Radiated Power) 감쇄에 영향을 주는 요소들을 가인자로 설정하고 변경 실험을 하였다. TRP의 가인자 중 실제로 영향을 주는 것으로 나타난 인자들은 안테나의 길이와 위치, 폴더의 각도, 안테나 주변의 그라운드 연결 방법이었고 이 부분들을 개선하여 팬텀 적용시 TRP의 감쇄가 개선전보다 약 5 dB 향상될 수 있음을 확인할 수 있었다.

Improving the brittle behavior of high-strength shielding concrete blended with lead oxide, bismuth oxide, and tungsten oxide nanoparticles against gamma ray

  • Mohamed Amin;Ahmad A. Hakamy;Abdullah M. Zeyad;Bassam A. Tayeh;Ibrahim Saad Agwa
    • Structural Engineering and Mechanics
    • /
    • 제85권1호
    • /
    • pp.29-53
    • /
    • 2023
  • High-strength shielding concrete against gamma radiation is a priority for many medical and industrial facilities. This paper aimed to investigate the gamma-ray shielding properties of high-strength hematite concrete mixed with silica fume (SF) with nanoparticles of lead dioxide (PbO2), tungsten oxide (WO3), and bismuth oxide (Bi2O3). The effect of mixing steel fibres with the aforementioned binders was also investigated. The reference mixture was prepared for high-strength concrete (HSCC) containing 100% hematite coarse and fine aggregate. Thirteen mixtures containing 5% SF and nanoparticles of PbO2, WO3, and Bi2O3 (2%, 5%, and 7% of the cement mass, respectively) were prepared. Steel fibres were added at a volume ratio of 0.28% of the volume of concrete with 5% of nanoparticles. The slump test was conducted to workability of fresh concrete Unit weight water permeability, compressive strength, splitting tensile strength, flexural strength, and modulus of elasticity tests were conducted to assess concrete's engineering properties at 28 days. Gamma-ray radiation of 137Cs emits photons with an energy of 662 keV, and that of 60Co emits two photons with energies of 1173 and 1332 keV were applied on concrete specimens to assess radiation shielding properties. Nanoparticles partially replacing cement reduced slump in workability of fresh concrete. The compressive strength of mixtures, including nanoparticles was shown to be greater, achieving 94.5 MPa for the mixture consisting of 7.5 PbO2. In contrast, the mixture (5PbO2-F) containing steel fibres achieved the highest values for splitting tensile, flexural strength, and modulus of elasticity (11.71, 15.97, and 42,840 MPa, respectively). High-strength shielded concrete (7.5PbO2) showed the best radiation protection. It also showed the minimum concrete thickness required to prevent the transmission of radiation.

방사선 차폐용 중량콘크리트의 기초 특성 (Properties of Heavyweight Concrete for Radiation Shielding)

  • 양승규;엄태선;이종열;김용호;우상익;김태봉
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.561-564
    • /
    • 2008
  • 콘크리트는 방사선 차폐용 구조물에 광범위하게 사용되고 있는 재료 중의 하나이다. 특히, 중량콘크리트는 중장비 또는 엘리베이터의 무게중심 등으로도 일부 사용되지만, 일반적으로 방사선 차폐 구조물에 주로 사용된다. 중량콘크리트는 일반 콘크리트 대비 높은 밀도뿐만 아니라, 콘크리트 배합적으로도 특별한 조성을 갖는다. 중량콘크리트를 구성하는 재료 중, 특히 중요한 것이 골재의 선정이다. 목표로 하는 콘크리트 밀도를 얻기 위해서는 실험 등에 의해 적절한 골재의 선정이 무엇보다도 중요하다. 그러나, 국내 실정에 적합한 중량골재원 및 이에 대한 참고자료가 많지 않은 상황으로, 지속적인 연구개발 및 관심이 필요한 상황이다. 따라서, 본 연구에서는 국내 실정에 적합한 방사선 차폐용 고밀도 중량콘크리트의 실용화를 목적으로, 골재 및 기타 재료의 적합성 시험, 콘크리트 기초 물성시험 등을 통하여 고밀도 중량콘크리트의적용 가능성을 검토하였다.

  • PDF

6 MV 광자선의 투과성필터와 Wedge 선속을 이용한 부비강의 균등선량계획 (Homogeneous Dose Planning to Paranasal Sinus with the Partial Attenuation filters and Wedged Beams in 6 MV Photon Beam)

  • 최태진;이호준;김옥배
    • Radiation Oncology Journal
    • /
    • 제11권1호
    • /
    • pp.183-191
    • /
    • 1993
  • The homogeneous dose planning is one of the most important roles in radiation therapy. But, it is not easy to obtain a homogeneous dose to paranasal sinus region including the ethmoidal sinus with conventional irradiation techniques. In this experimental study, the authors tried to get a homogeneous dose at PNS region, but the nasal cartirage does not exceed the tolerance dose, with anterior-posterior beam and two both lateral wedged beams. Used three fields were shielded with full thickness of blocks to preserve the eye-balls and with blocks of one half value layer to create a homogeneous dose at the whole treatment volume. The dose computations are based on the three dimensonal structure with modified scatter contributions of partial shielders and attenuated beams in 6 MV photon beams. The dose distributions of mid-plane is examined with Kodak verification films and teflon-embedded TLD rod (1 mm diameter and 6 mm length) to confirm the computed dose. In our study, the whole PNS regions have shown within $85{\%}$ of the resultant isodose curves with relatively homogeneous dose distribution. The results of dose computation and measurements are agree well within $5{\%}$ uncertainties.

  • PDF