• Title/Summary/Keyword: radial pulse

Search Result 193, Processing Time 0.023 seconds

Analysis of Pulse Wave Parameters According to Aging for Arteriosclerosis Evaluation (동맥경화 평가를 위한 연령별 맥파 주요인자 분석)

  • Lee, Na-Ra;Lee, Seung-Wook;Kim, Soo-Byeong;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.79-89
    • /
    • 2011
  • Objectives : The aim of this study is to propose the W area of pulse (AW) as a new index which can confirm the arteriosclerosis by analyzing parameters of 5-level pressure pulse waveform measurement system for normotensive group according to aging. Methods : We measured radial pulse waveforms of normotensive group (20 to 60 years old) using 3-dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea). And then we analyzed various parameters for sclerosis of the arteries such as Height (h1, h2, h3, h4, h5), Time (t1, t2, t3, t4, t5), AW, AW rate, Total area of pulse (At) and Augmentation Index (AIx). Results : As a result of analyzing parameters according to the aging, h2, h3, AS (systolic area rate to AT), AIx and AW were increased but t2/t, t3/t, t5/t and AD (diastolic area rate to AT) were decreased. Conclusions : We checked blood vessel conditions for normotensive group according to aging and confirmed various parameters. Also, we found that AW was analogous to AIx which has been used for diagnosing arteriosclerosis. Furthermore, we confirmed the usefulness of AW as a new parameter for checking vessel condition and characteristic compared with the AIx.

Development of Blood Pressure Measuring System using piezoelectric and photo sensor (광센서와 압력센서를 이용한 맥박측정시스템 개발)

  • Choi, Young-Suk;Kim, Kyung-Jae;Hong, Woo-Heon;Ryu, Jeong-Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.149-154
    • /
    • 2009
  • By increasing people's average life span, interest for health is highly growing. According to hoping to check their body condition, people have a medical checkup periodically to check their condition. But, they can prevent disease or are able to make a health care through checking people's pulse or blood pressure. In this paper, two different pulse measurement systems were developed, one system using a photosensor which is able to measure transmissivity's change through blood volume and another system using a piezo-electric sensor which can measure pulse when it measures radial artery's pressure in the wrist are realized. We compared two systems each other.

High-Order Surface Gradient Coil Design Using Target Field Approach

  • Lee, J.K.;Yang, Y.J.;Jeong, S.T.;Choi, H.J.;Cho, Z.H.;Oh, C.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.19-24
    • /
    • 1996
  • The purpose of this paper is to design high-order (or radial) surface gradient coil (SGC), which can provide multi-dimensional spatial selection. Although the spatial Selection with High-Order gradienT (SHOT) can provide a 2-D selection with only one selective RF pulse, the high-order gradient pro- duced by conventional cylindrical-shape coils has not been clinically useful due to the large selection size caused by the limited radial gradient intensity. However, by using the proposed high-order SGCs located near the imaging region, the size of volume selection can be reduced to a clinically useflll size of 1-2 cm in diameter by applying stronger radial gradient field with much less gradient driving power. So far radial SGCs have been designed by using the field component method and may cause distortion in the selection shapes. In this paper, by using the target field approach for the coil design, selected volumes became almost circular. A 40 cm-by-40 cm $z^2$_surface gradient coil has been designed and implemented by using the target field approach. Phantom and volunteer studies have been performed Experimental results using spatially localized MRI show good agreement to the theoretically predicted behavior.

  • PDF

A Theoretical Study of Photothermal Pulsed Radiometry Method for the Thermal Diffusivity Measurement (재료의 열확산계수 결정을 위한 광열복사법의 이론적 연구)

  • Yook, Hyung-Kyu;Yoo, Jai-Suk;Kim, Hyun-Jung;Lee, Kwang-Jai
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.27-34
    • /
    • 2005
  • We analyze in detail axially symmetric theoretical study for the photothermal pulsed radiometry of a cylindrical model. The theoretical solutions describe the transient infrared radiation from the sample heated by short-duration pulsed heating. In the conventional transmission radiometry technique, the excitation source and the detector are on opposite sides of the sample, otherwise in the new single ended radiometry technique, the excitation source and the detector are on same sides of the sample. The analytical solution described for photothermal radiometry in this study would not need to cut or polish samples to measure the thermal diffusivity. Therefore the radial area and axial thickness of samples are not limited. The effects of excitation pulse duration and the area of heat source are discussed.

Vibration and Acoustic Noise characteristic on SRM with compensating winding that two stage commutation is used at commutation action (2단계 소호전압방식을 적용한 보상권선형 SRM의 진동.소음특성)

  • Lee, Jong-Gun;Jung, Tae-Uk;An, Young-Joo;Hwang, Young-Moon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.55-57
    • /
    • 1999
  • SRM Drives generate large vibration and acoustic noise because it is rotated by step pulse mmf and switching commutation mechanism. The main vibration source of SRM Drive is generated by rapidly variation of radial force when phase winding current is extinguished for commutation action. So the rapidly variation of radial force is repressed firstly to reduce vibrating force of SRM Drive. This paper suggests the vibration reduction method that SRM Drive with unidirect-short compensation winding is excited by a two stage commutation method at commutation period. This reduction effect of vibration is verified with the result obtained in the test of prototype machine.

  • PDF

A study on the pulse wave factor according to BMI and period of sterility on female (난임 여성의 체질량지수(BMI), 불임기간에 따른 맥파 연구)

  • Kim, Gyeong-Cheol;Kim, Yi-Soon
    • Korean Journal of Oriental Medicine
    • /
    • v.18 no.2
    • /
    • pp.139-149
    • /
    • 2012
  • Objectives : This is the study to understand of the pulse wave factor according to BMI and period of sterility on female, and to confirm the relationship of pulse wave factor among left and right inch, bar and cubit. Methods : The Questions and measurement of the pulse wave were operated with subjects(76 sterile females using on public health center). The measurement of the pulse wave was operated in 6 part of left and right inch, bar and cubit. The pulse wave was prior measured in part of left bar (i.e. interior pulsation part of radial process styloides in left hand), and next was measured in part of left inch and bar. And the pulse wave was operated samely in part of right inch, bar and cubit. Results : The results were as follows. The pulse energy of 6 part of left and right inch, bar and cubit was showed statistical significance and decreased in order of left inch, right inch, left cubit, right cubit, left inch, right bar. The left and right inch and cubit were showed numerical value of normal range, but left and right bar were showed lower pulse eneregy than normal range. Also left and right cubit were showed lower than left and right inch, and higher than left and right bar. In BMI, The pulse energy of left and right inch, cubit and the average of right hand was not showed statistical significance in the range of low-weight, normal, over-weight and obesity. But in the left and right bar and the average of left hand, the pulse energy of over-weight and obesity group were showed significantly higher than low-weight group. And the pulse wave factor was divided the pattern of h1 showing high numerical value in inch (Ap, As, Aw) and the pattern of Wm showing high numerical value in bar and cubit (RAI, Ad) Conclusions : The low pulse energy of bar was significant observation on the setting of oriental medical diagnostic index on sterilitas. Also, in the numerical value pattern of diverse pulse wave factor, it was divided the pattern of high numerical value in inch and the pattern of high numerical value in bar and cubit. On this, we think that the studies need in the future.

Achievement of 3-D Pulse Waves of Pulse Diagnostic Apparatus by using Multi-Hall Devices (다중 홀소자를 이용한 맥진기의 3차원 파형 획득 연구)

  • Choi, S.D.;Kim, M.S.;Ahn, M.C.;Choi, Y.G.;Kim, G.W.;Park, D.H.;Hwang, D.G.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.4
    • /
    • pp.216-220
    • /
    • 2006
  • The electric signals for the voltage as a function of distance between Hall devices and permanent magnets over the radial artery were investigated. The electric sgnals, that means signals of arterial pulse wave, were differentiated by the hardware of circuits and then were changed to differential signals as magnetic field. The 3-D images simulated by the software as function fo the intensity of differential signals were achieved. It shows that these system can apply to pulse diagnostic apparatus of porthble type medical instrument.

Effects of bee venom acupuncture on heart rate variability, pulse wave, and cerebral blood flow for types of Sasang Constitution (봉약침 자극이 사상체질별 건강인의 심박변이도, 맥파, 뇌혈류에 미치는 영향)

  • Lee, Sang-Min;Kim, Koo;Oh, Seung-Yun;Kwon, Young-Mi;Joo, Jong-Cheon
    • Journal of Pharmacopuncture
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 2009
  • 1. Objectives To evaluate effects of bee venom acupuncture on cardiovascular system and differences according to each constitution. 2. Methods Heart rate variability, pulse wave and the velocity of cerebral blood flow were measured before bee venom acupuncture(BVA), right after and after 30 minuets, had been applied to 20 subjects. 3. Results 1. BVA did not have effects on measurement variables of heart rate variability. 2. BVA had effects on pulse wave, showing total time, radial augmentation index up and height of percussion wave, time to percussion wave, sum of pulse pressure down. 3. BVA did not have effects on the cerebral blood flow velocity when considering not Sasang Constitution. 4. Considering Sasang Constitution, BVA demonstrates different responses in time to preincisura wave, mean blood flow velocity, peak systolic velocity and end diastolic velocity. 4.Conclusion From those results, the following conclusions are obtained. Cause BVA alters pulse wave and makes differences in the cerebral blood flow velocity according to Sasang Constitution. Various methods of BVA treatment are needed considering Sasang Constitution.

The thermal analysis of te-based media for the optical recording (광기록에 이용되는 Te-based media에 대한 열적 해석)

  • 이성준;천석표;이현용;정홍배
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.64-70
    • /
    • 1995
  • We discussed the thermal analysis for a recording media with the variation of the laser pulse duration, the laser power and the temperature distribution in order to optimize the Te-based antireflection structure from the computer calculations. In the case that the radial heat diffusion is negligible, we can calculate the maximum temperature of the recording layer at the center of the spot by the Simple Model. The temperature profile of the recording layer is obtained from the Numerical Model by considering the total specific heat and the latent heat. As a result, the effect of the heat sinking acting as a thermal loss for the hole formation could be minimized by introducing the pulse with the hole formation duration(.tau.) below the thermal time constant(.tau.$_{D}$) of a dielectric layer. These requirments can be satisfied by using the dielectric thickness of the 2nd ART(Anti-Reflection Trilayer) condition or the dielectric materials with a low thermal diffusivity.y.

  • PDF

Localized Electro-chemical Micro Drilling Using Ultra Short Pulses (초단펄스 전해 국부화를 이용한 미세구멍 가공)

  • 안세현;류시형;최덕기;주종남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.213-220
    • /
    • 2003
  • By the localization of electro-chemical dissolution region, we succeeded in a few micrometer size hole drilling on stainless steel with the radial machining gap of about 1 ${\mu}{\textrm}{m}$. Tens of nanosecond duration voltage pulses were applied between WC micro-shaft and stainless steel in the 0.1 M $H_2SO_4$ solution. Pt balance electrode was used to drill the high aspect ratio micro-hole without generation of Cr oxide layer on the machined surface. The effects of applied voltage, pulse duration, and pulse period on localization distance were investigated according to machining time. We suggested the taper reduction technique especially brought up on blind-hole machining. High quality micro-holes with 8 ${\mu}m$ diameter with 20 ${\mu}m$ depth and 12 ${\mu}m$ diameter with 100 ${\mu}m$ depth were drilled on 304 stainless steel foil. The various hole shapes were also produced including stepped holes and taper free holes.