• Title/Summary/Keyword: radial motion

Search Result 303, Processing Time 0.031 seconds

Characteristics of Spray from Pressure-Swirl Nozzle with Different Liquid Properties and Nozzle Geometries (액체의 물성치와 노즐의 형상 변화에 따른 압력스월 노즐의 분무 특성)

  • Choe, Yun-Cheol;Jeong, Ji-Won;Kim, Deok-Jul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1813-1820
    • /
    • 2001
  • The purpose of this study was to investigate the significant characteristics in atomization process of industrial etching spray fur the design or Precise pressure-swirl nozzles. The experiment was carried out with different viscosities and densities of the liquid. The macro characteristics of liquid spray, such as the spray angle and breakup process were captured by PMAS and the micro characteristics of liquid spray. such as droplet size and velocity measurements were obtained by PDA. The droplet axial and radial velocity and SMD were measured along axial and radial direction. The RMS of two velocities was measured along radial direction. It was found that the fluid with higher kinematic viscosity resulted in the larger SMD and the lower mean droplet velocity. And we could divide breakup processes into three regions that is atomization, non-dilution and dilution one in spray of pressure-swirl nozzle. The radial as well as axial velocity of droplet played an important role in the atomization process of higher kinematic viscosity fluid.

Organizartion of Measurin System of Circular Motion Accuracy of Machining Center (머시닝센터의 원운동정도 측정시스템의 구성)

  • 김영석;낭궁석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.305-311
    • /
    • 1993
  • In recent years, it has been variously developed for testing the accuracy of circular motion of NC machine tools, for example Telescoping Ball Bar Method by Bryan,Circular Test Method by Knapp and r $_{- \theta}$ Mathod by Tsutsumi etc., but it is not yet settled in the code of measuring methods of motion errors of NC machine tools, because of errors of measuring units and sensors, and also especially the difficulties of centering of measuring units. In this paper, in use of magnetic type linear scale with resolution of 0.5 .mu. m and tick pulses come out from computer, it has become possible for detecting of linear displacement of radial errors and measuring of revolution angle of circular motion of NC machine tools.

  • PDF

Development of System for Measurement and Evaluation for Machine tool Spindle (공작기계 주축 스핀들 종합오차 측정 및 평가기술개발)

  • 신현장;이석원;박희재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.1005-1008
    • /
    • 1995
  • The spindle is a very important part of machine tool. The evaluation of spindle motion is required for improving the performance of machine tools. The evaluation tools have been developed for precison spindle by the reversal technique, and 3D error map motion of spindle is proposed. This technique makes us understand the total movement of spindle more easily. The proposed technique has been successfully applied to practical machine tools, giving high potentials for the spindle performance measurement.

  • PDF

Screw Motion and Control of Conductive Rod by Rotating a Spiral Electrodynamic Wheel (동전기 휠을 이용한 전도성 환봉의 나선형 운동과 제어)

  • Jung, Kwang-Suk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.9
    • /
    • pp.882-887
    • /
    • 2011
  • A spiral electrodynamic wheel is proposed as an actuator for the contactless conveyance of a conductive rod. When rotating the wheel around the rod, a radial force, a tangential force, and an axial force are generated on the rod and cause a screw motion of the rod. The rotation of the rod is the inevitable result due to traction torque of the wheel and the unintended motion to be excluded. However, the rotating speed of the rod should be measured without mechanical contact to be cancelled out through the controller, so the electrodynamic wheel is used as a sensor measuring the rotating speed of the rod indirectly as well as an actuator. In this paper, we model the magnetic forces by the proposed wheel theoretically and compare the derived model with simulation result by Maxwell, and analyze influences on the magnetic forces by key parameters constituting the wheel. The feasibility of the conveyance system is verified experimentally.

Evaluation and Analysis of Dynamic Characteristics in Tilt Actuator for High Density Optical Storage Devices (고밀도 광저장 기기용 틸트 액추에이터 동특성 분석 및 평가)

  • 김석중;이용훈;최한국
    • Journal of KSNVE
    • /
    • v.10 no.4
    • /
    • pp.584-595
    • /
    • 2000
  • We design a new actuator for high density optical device in order to control the radial tilting motion. The newly designed actuator makes it possible to control the tilting motion actively, while the coventional actuator compress tilting motion with passive spring. First of all, We present 3-dimensional modeling of actuator and accomplish the modal analysis and magnetic analysis of actuator. Due to these results, a new designed actuator has performance of high sensitivity and high second resonance frequency. Secondly, We present the 3-DOF dynamic modeling of the 4-wire spring type actuator. sensitivity analysis is performed to consider the assembling error, such as the difference of mass center and force center. From these results, the sensitivities of rotation due to the assembly error are revealed and design criteria of rotation is presented. And experimental results of a newly designed actuator are presented and compared with theoretical results. Finally, We propose a dynamic tilt compensation and high acceleration actuator for high density optical storage devices.

  • PDF

Coasting and Post-impact Motion of a Vehicle With Tire Blowout (타이어 펑크 차량의 주행 및 충돌후 거동)

  • Han, Inhwan;Lim, Sanghyun;Park, Jong-Chan;Choi, Jihun
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.5
    • /
    • pp.503-512
    • /
    • 2014
  • In this paper, various tire blow-out force experiment data were collected and analyzed to obtain approximate values of related coefficients such as rolling resistance, self-aligning torque, cornering stiffness, and radial stiffness for the analysis of the motion of vehicles with tire blow-outs. These coefficients related to tire blow-outs were input into a vehicle accident analysis program to simulate and examine the effects of tire blow-outs. Various configurations and velocities of vehicle collisions without tire blow-outs were also used as reference to establish collision events of vehicle collisions with tire blow-outs. For the events, the simulation analysis was performed and collision characteristics were obtained. Consideration of tire blow-outs or damages suggested in this study will greatly contribute to more reliable vehicle accident reconstructions.

Isolated Anterior Dislocation of the Radial Head in Adult - A Case Report - (성인에서 발생된 요골 두 급성 전방 탈구 - 증례 보고 -)

  • Heo, Youn-Moo;Kim, Woo-Sik;Kim, Sung-Hun;Jeon, Teak-Soo;Kim, Sang-Bum;Oh, Byung-Hak
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.131-135
    • /
    • 2007
  • We report an isolated anterior dislocation of the radial head in a 23-year-old man after a fall on the outstretched arm. At the time of the injury, the patient's elbow was in a position of mild flexion and pronation which was suddenly further pronated as he fell down. The radial head was incarcerated by the lateral portion of brachialis muscle, and annular ligament was interposed between capitellum and radial head. Open reduction was performed. During 12 months follow-up, reduction of radial head was well maintained without a limitation of range of motion.

A study for measurement of radial artery oxygen saturation system using photoelectric plenthysmography (광전용적맥파를 이용한 요골동맥 산소포화도 측정 시스템의 연구)

  • Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.3
    • /
    • pp.11-18
    • /
    • 2010
  • In this study, the pulse of radial artery and oxygen saturation are detected using photoelectric plethysmograph method. Using our device designed reflection type, we can detect the reflected light by radial artery and by switching circuit, we can also separate to 625nm band signal and 940nm band signals. The separated signals are converted as a pulse data by the pulse signal processing circuit. In this study, the reflection type of oxygen saturation calculation method is applied instead of the transmission type because of the reflection type sensor is used to measure the radial artery. As a result, we can detect about 97% accuracy of the oxygen saturation compare with the conventional method. For the accurate signals, the wrist band with sensor was designed and fixed on the radial artery. As a result, this wrist band type sensor was applicable to prevent position errors from motion artifact and could increase the accuracy during the measuring.

Short- to mid-term outcomes of radial head replacement for complex radial head fractures

  • Baek, Chung-Sin;Kim, Beom-Soo;Kim, Du-Han;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.4
    • /
    • pp.183-189
    • /
    • 2020
  • Background: The purpose of the current study was to investigate short- to mid-term outcomes and complications following radial head replacement (RHR) for complex radial head fractures and to identify factors associated with clinical outcomes. Methods: Twenty-four patients with complex radial head fractures were treated by RHR. The mean age of the patients was 49.8 years (range, 19-73 years). Clinical and radiographic outcomes were evaluated for a mean follow-up period of 58.9 months (range, 27-163 months) using the visual analog scale (VAS) score for pain, the Mayo elbow performance score (MEPS), the quick disabilities of the arm, shoulder and hand (Quick-DASH) score, and serial plain radiographs. Complications were also evaluated. Results: At the final follow-up, the mean VAS score, MEPS, and Quick-DASH score were 0.6±1.1, 88.7±11.5, and 19.4±7.8, respectively. The mean range of motion was 132.7° of flexion, 4.7° of extension, 76.2° of pronation, and 77.5° of supination. Periprosthetic lucency was observed in six patients (25%). Heterotopic ossification was observed in four patients (16.7%). Arthritic change of the elbow joint developed in seven patients (29.2%). Capitellar wear was found in five patients (20.8%). Arthritic change of the elbow joint was significantly correlated with MEPS (P=0.047). Four cases of complications (16.6%) were observed, including two cases of major complications (one stiffness with heterotopic ossification and progressive ulnar neuropathy and one stiffness) and two cases of minor complications (two transient ulnar neuropathy). Conclusions: RHR for the treatment of complex radial head fractures yielded satisfactory short- to mid-term clinical outcomes, though radiographic complications were relatively high.