• Title/Summary/Keyword: radial

Search Result 5,360, Processing Time 0.044 seconds

RADIAL COLOR GRADIENT IN A GLOBULAR CLUSTER 1. M68

  • Yi, Su-Kyoung;Chun, Mun-Suk
    • Journal of Astronomy and Space Sciences
    • /
    • v.7 no.2
    • /
    • pp.105-111
    • /
    • 1990
  • Stars in M 68 from the observed-magnitude diagrams with CCD were integrated to find any radial gradient. The result shows that M 68 has a slightly bluer core. The main cause of these calculated radial color variations seems to come from the random distribution of ginants.

  • PDF

NEW CARDINAL FUNCTIONS RELATED TO ALMOST CLOSED SETS

  • Cho, Myung Hyun;Moon, Mi Ae;Kim, Junhui
    • Honam Mathematical Journal
    • /
    • v.35 no.3
    • /
    • pp.541-550
    • /
    • 2013
  • In this paper, we strengthen the properties of approximation by points (AP) and weak approximation by points (WAP) considered by A. Pultr and A. Tozzi in 1993 to define ${\kappa}$-AP and ${\kappa}$-WAP for an infinite cardinal ${\kappa}$. We also strengthen the properties of radial and pseudoradial to define ${\kappa}$-radial and ${\kappa}$-pseudoradial for an infinite cardinal ${\kappa}$. These allow us to consider new cardinal functions related to almost closed sets; AP-number, WAP-number, radial number, and pseudoradial number. We study their properties and show the relationships between them. We also provide some examples around ${\kappa}$-AP and ${\kappa}$-WAP which are closely connected with ${\kappa}$-radial and ${\kappa}$-pseudoradial.

A STUDY ON κ-AP, κ-WAP SPACES AND THEIR RELATED SPACES

  • Cho, Myung Hyun;Kim, Junhui
    • Honam Mathematical Journal
    • /
    • v.39 no.4
    • /
    • pp.655-663
    • /
    • 2017
  • In this paper we define $AP_c$ and $AP_{cc}$ spaces which are stronger than the property of approximation by points(AP). We investigate operations on their subspaces and study function theorems on $AP_c$ and $AP_{cc}$ spaces. Using those results, we prove that every continuous image of a countably compact Hausdorff space with AP is AP. Finally, we prove a theorem that every compact ${\kappa}$-WAP space is ${\kappa}$-pseudoradial, and prove a theorem that the product of a compact ${\kappa}$-radial space and a compact ${\kappa}$-WAP space is a ${\kappa}$-WAP space.

Effects of Cadmium on Radial Growth and Dry Mass Production of Ectomycorrhizal Fungi

  • Kim, Chang-Gi;Power, Sally Anne;Bell, John Nigel Berridge
    • The Korean Journal of Ecology
    • /
    • v.27 no.5
    • /
    • pp.301-306
    • /
    • 2004
  • The sensitivity to Cd of three ectomycorrhizal fungi, Paxillus involutus, Suillus bovinus and Rhizopogon subcaerulescens, was assessed and compared in terms of radial growth and dry mass production, using both agar and liquid culture. The radial growth of S. bovinus and R. subcaerulescens was significantly reduced at the lowest concentration (0.1mg Cd/L). The 50% effective concentration (EC$_{50}$) values calculated from radial growth rates of the ectomycorrhizal fungi showed that the sensitivity of the fungi to Cd was greatest in S. bovinus and lowest in R. subcaerulescens. Cadmium addition also significantly decreased dry mass production of the ectomycorrhizal fungi. The sensitivity of the fungi to Cd in terms of dry mass production, was greatest in S. bovinus and lowest in P. involutus. Higher growth rates of P. involutus and melanisation of R. subcaerulescens appeared to contribute to reduced Cd toxicity.

Precise Measurement Method of Radial Artery Pulse Waveform using Robotic Applanation Tonometry Sensor (로보틱 토노메트리 센서를 이용한 요골 동맥 파형 정밀 측정 방법)

  • Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 2017
  • In this paper, a novel measurement method of radial artery pulse waveform using robotic applanation tonometry (RAT) was present to reduce the errors by the pressing direction of the vessel. The RAT consisted of an array of pressure sensors and 2-axis tilt sensor, which was attached to the universal joint with a linear spring and five-DOF robotic manipulator with a one-axis force sensor. Using the RAT mechanism, the pulse sensor could be manipulated to perpendicularly pressurize the radial artery. A pilot experimental result showed that the proposed mechanism could find the optimal pressurization angles of the pulse sensor within ${\pm}3^{\circ}$standard deviations. Coefficient values of variation of maximum pulse peaks extracted from the pulse waveforms were 4.692, 6.994, and 11.039 % for three channels with the highest magnitudes. It is expected that the proposed method can be helpful to develop more precise tonometry system measuring the pulse waveform on the radial artery.

Finite Element Analysis on the Shaft Fitting to Inner Raceway of Radial Ball Bearing (레이디얼 볼베어링의 내륜 끼워맞춤에 관한 유한요소해석)

  • Ko, Byung-Du;Lee, Ha-Sung
    • Design & Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.45-51
    • /
    • 2012
  • The main goal of this paper is to establish an interference tolerance for determining optimal amount of clearance in the shaft-bearing system supported by radial ball bearings. The 2-D frictional contact model was employed for the FE analysis between the shaft and the inner raceway. Several examples were simulated using different material properties for the solid shaft. Efforts were focused on the deformation applied in the radial direction to select suitable bearings. The analysis results showed that the initial axial preload applied on the bearings plays a significant role to reduce bearing fatigue life. The proposed design parameters obtained by numerical simulations can approximately predict a rate of bearing life reduction as a function of shaft diameter ratio. This analysis can also be used to calculate the optimal initial radial clearance in order to obtain a shaft-bearing system design for high accuracy and long life.

  • PDF

Design of Combined Radial and Axial 4-pole Electromagnetic Bearing (I) - with Uncoupled Bias Flux - (반경방향-축방향 일체형 4극 전자기 베어링의 설계 (I) - 바이어스 자속 독립형 -)

  • Kim Ha-Yong;Kim Seung-Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1561-1566
    • /
    • 2005
  • In this paper, a new compact active magnetic bearing(AMB) is proposed in which radial and axial bearings are integrated in one bearing unit. It consists of four U-shaped cores circumferentially connected by yokes and two-layer coils for radial and axial controls. For the radial control action, it has the same principle as conventional homopolar AMBs, while for the axial control, it uses the Lorentz force generated by the interaction of the bias flux for radial control and the axial control flux. The proposed structure makes it easy to design a compact AMB because it has no disk for axial control. This paper introduces the proposed structure, principle, and design process based on the magnetic flux analysis. By using a control algorithm with feedforward action to compensate the coupled flux effect, the feasibility of the proposed AMB is experimentally verified.

Design of Radial Force Control System for BLSRM (베어링리스 SRM의 축방향 지지력 제어 시스템 설계)

  • Park, Tae-Hub;Wang, Huijun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.865_866
    • /
    • 2009
  • In this paper, a novel structure Bearingless SRM with hybrid stator poles is proposed. The motor torque can be controlled independently from radial force control. Analytical models of torque and radial force for proposed structure are explained. Based on these models, control scheme of desired radial force is proposed. In this control method, the magnitude of force can be controlled in arbitrary direction and magnitude by selecting some combinations of radial force windings. The validities of structure and control method are verified by the experimental results when motor is at standstill and running.

  • PDF

Multi-Point Radial Artery Pulse Wave Transducer using Pneumatic System (공압 방식에 의한 다지점 요골 맥파 검출 장치)

  • 이종진;정민석;황성하;이종현;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.243-248
    • /
    • 2001
  • A radial artery pulse wave is well known as a good mans to diagnose human body condition in th field of Chinese medical science. Information about constitution as well as organs can be obtained by detecting the artery pulse wave. Recently, the information about the human body constitution may be utilized in accelerating the recovery process of the patient on the basis of comprehensive diagnosis. A radial artery pulse wave is considered as one of promising means in examining the human body constitution. Since the examination has been conducted by the feeling of finger, the diagnosis may occasionally have uncertainty or fatal error. In this paper, a new measuring system is suggested and developed to examine the pattern of a pulse wave correctly. The system is composed of four pressure vessels, pressure sensors and air supplying pumps. One of them is utilized for appropriately pressing the radial artery, three of them for detecting pressure change in several mmHg level. The detected data is shown and discussed.

  • PDF