• 제목/요약/키워드: quartz crystal oscillator

검색결과 19건 처리시간 0.037초

수정진동자를 사용한 점탄성 유체의 점성계수와 전단 탄성계수 측정에 관한 이론해석 (Theoretical Analysis for the Measurement of Viscosity and Shear Modulus of Viscoelastic Fluids by Using a Quartz Crystal Oscillator)

  • 서용권;김영한
    • 대한기계학회논문집B
    • /
    • 제32권7호
    • /
    • pp.487-496
    • /
    • 2008
  • Quartz crystal oscillator is frequently used in measuring a very small amount of mass attached to or adsorbed on the surface of an electrode on the quartz plate. The physical principle is that the resonance frequency of the shear vibration of the quartz caused by an applied electric field is a function of the mass. Recently, effort has been tried to measure physical properties of viscoelastic fluids, such as viscosity and shear modulus. This paper presents useful formula that can be used in estimating the properties of viscoelastic fluids. Important finding in this analysis is that the formula can produce multiple values for the physical properties of the viscoelastic materials.

Construction of Low Noise Electrochemical Quartz Crystal Microbalance

  • 황의진;임영란
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권1호
    • /
    • pp.39-42
    • /
    • 1996
  • A new oscillator for electrochemical quartz crystal microbalance (EQCM) was developed by using an operational amplifier without any LC component. The home-made EQCM using this oscillator showed only 0.02 Hz frequency noise at 0.3 s gate time when a 6 MHz AT-cut crystal was used. Pb underpotential deposition on gold substrate in nitric acid media was examined to demonstrate the performance of this EQCM. The derivative of frequency change could be obtained without averaging multiple scans.

A CMOS Temperature Control Circuit for Crystal-on-Chip Oscillator

  • Park, Cheol-Young
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.103-106
    • /
    • 2005
  • This paper reports design and fabrication of CMOS temperature sensor circuit using MOSIS 0.25um CMOS technology. The proposed circuit has a temperature coefficient of $13mV/^{\circ}C$ for a wide operating temperature range with a good linearity. This circuit may be applicable to the design of one-chip IC where quartz crystal resonator is directly mounted on CMOS oscillator chips.

  • PDF

수정진동자를 이용한 메탈 삽입 테프론 다이어프램 압전소자모듈의제조 및 특성 (Fabrication and characteristic of metal insertedteflon diaphragm piezoeletric device module using quartz crystal oscillator)

  • 김경민;박성현;김성우;손원근;신병철
    • 센서학회지
    • /
    • 제19권2호
    • /
    • pp.149-154
    • /
    • 2010
  • Top of the alumina body which is made according to plan has been printed using a screen printer equipment in order to print an electrode pattern. The electrode is connected with the quartz crystal oscillator of the piezoelectricity method which has a piezoelectric characteristic. The pressure contact department has been experimented using three type of the teflon. The teflon is good for pressure delivery vector but it is bad restitution. So we devised the structure which inserts the metal in the teflon. Bottom of the module is connected with the signal processing department which is planned in advance and then has investigated to characteristic. Therefore we have got the best output-voltage and frequency characteristic follows in the pressure.

수정 진동자를 이용한 근접장광학계 (Near-Field Scanning Optical Microscope) 제작 및 특성연구 (A study on the feedback control system for near field scanning optical microscope based on the tuning fork oscillator)

  • 윤선현
    • 한국광학회지
    • /
    • 제10권4호
    • /
    • pp.267-272
    • /
    • 1999
  • 근접장광학계 (Near-Field Scanning Optical Microscope :NSOM)의 표본과 팁의 거리 유지를 위해 소리굽쇠모양의 수정발진자 (tuning forktype quartz crystal unit)의 한쪽 다리에 광섬유를 고정시키고 광섬유 팁을 수정발진자와 같이 진동하게 만들어 사용하였다. 수정 진동자는 광섬유 팁이 시료에 얼마나 가까이 갔느냐에 따라 진폭이 바뀌게 되고 이 변화를 일반적인 방법인 레이저 빛에 의하여 읽어내는 것이 아니라 바로 수정 발진자의 임피던스 변화에 따른 전압 변화를 측정하여 알아냈다. 팁이 표면에 접근함에 따라 수정발진자 진동폭의 변화와 팁을 통해 들어오는 빛의 세기 변화 등을 측정하여 계의 감도를 조사하였다.

  • PDF

수정진동자를 이용한 메로시아닌 색소 LB막의 광반응 특성 (The analysis of the optical response of merocyanine LB films using QCM)

  • 강기호;김정명;장정수;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.434-436
    • /
    • 2000
  • In this study, we investigate the optical characteristics of merocyanine dye Langmuir-Blodgett(LB) film using the oscillation characteristics of quartz crystal. As results, the resistance and frequency shift at the parallel resonance under the UV irradiation is to be going down. This behaviour of resistance and frequency is different from the case of general mass adsorption into the organic film on the quartz crystal. Generally the frequency decrease of quartz crystal oscillator, which has been considered as mass loading, goes along with the resistance increase. Thus it has been suggested that the J-aggregate dissociation in merocyanine dye LB film by UV irradiation give rise to transformation of oscillation characteristics of quartz crystal.

  • PDF

소금용액에 포함된 글루코오스 농도의 전기화학적 측정 (Electrochemical Determination of Glucose Concentration Contained in Salt Solution)

  • 김영한
    • 한국항만학회지
    • /
    • 제14권4호
    • /
    • pp.475-479
    • /
    • 2000
  • A possibility of the implementation of a quartz crystal sensor to the determination of chemical oxygen demand is examined by checking the electrochemical behavior of the sensor in a glucose solution. Since the surface of a quartz crystal has to be oxidized, a relatively active metal is coated on the surface of a usual 9 MHz AT-cut crystal. The electrochemical behavior is investigated by measuring the changes of current, resonant frequency and resonant resistance while a constant potential is applied. The crystal is installed in a specially designed container, and a quartz crystal analyzer is utilized to measure the frequency and resistance simultaneously. The variations of the measurements are examined at different concentrations of glucose solution, and a proper relation between the concentrations of glucose solution, and a proper relation between the concentration and the measurements is analyzed. As a result, it is found that a linear relation between the concentration of less than 900 ppm and the peak current when a constant potential of -180 mV (SSCE) is applied. The relation can be utilized for the determination of glucose concentration in sea water, and considering a direct relation between gluose concentration and chemical oxygen demand tells a possibility of the measurement of chemical oxygen demand using quartz crystal oscillators.

  • PDF

전극형상을 고려한 수정진동자 해석 기법 연구 (FEM analysis of Quartz oscillator considering dimensions of electrode)

  • 박승배;김종정;이덕훈;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.543-546
    • /
    • 2001
  • So far, the design methods of quartz crystal resonator have been developed. Recently, as the electronic package and semiconductor modules become smaller, the need to minimize the sizes of crystal components grows larger. but Minimizing crystal plate sizes has limitations because its temperature-frequency characteristics is worse and unwanted resonances occur. so appropriate design of electrode size and crystal plates is necessary. In this palter, Two-dimensional governing equations for electroded piezoelectric crystal plates with general symmetry have been solved from deduced equations from three-dimensional equations of linear piezoelectricity in most cases. In practice, electroded piezoelectric crystal plates have three-dimensional geometry, so simplified 2-dimensional equations and 2-D modeling are insufficient for explaining its resonance modes and characteristics. So, three-dimensional FEM(finite element method) analysis is done and its effectiveness is verified from analyzing practical crystal resonator model.

  • PDF

해양오염 감지를 위한 활성탄 코팅 센서에 관한 연구 (A Study on an Activated Carbon Coated Sensor for the Detection of Marine Pollution)

  • 최광재;김영한
    • 한국항만학회지
    • /
    • 제14권3호
    • /
    • pp.373-378
    • /
    • 2000
  • Oil spill in sea water is the most frequent and significant problem of marine pollution. As an early detection sensor of the pollution, an activated carbon coated quartz crystal is prepared and examined for its performance of detection sensitivity and stability. Powdered activated carbon and phenol resin is coated on the surface of the sensor and the sensor is baked for an hour. Adsorption of acetone dissolved in water and salt water is measured using frequency shift of quartz crystal at different concentrations of solute material. The outcome indicates that the sensor preparation is adequate and the measurement of solute concentration is stable and sensitive enough to be implemented on the monitoring of solute concentration is stable and sensitive enough to be implemented in the monitoring of organic pollution of sea water.

  • PDF