• Title/Summary/Keyword: quantitative-correlation

Search Result 1,462, Processing Time 0.031 seconds

COMPARATIVE HISTOMORPHOMETRIC ANALYSIS OF MANDIBLE AND ILIAC BONE ON BONE DENSITY (하악골과 장골의 조직형태계측 비교)

  • Yoo, So-Jeong;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.12-25
    • /
    • 2000
  • To demonstrate possible influences of general bone density on the mandible, histomorphometric analysis was carried out in mandibles and iliac bones and the correlation of the two bone densities was tested. Comparison of bony density in women and men over 60 years in the mandible was carried out too. Quantitative computed tomography(QCT) was taken in cross-section of mandibles at the same site where histomorphometric analysis was peformed to evaluate the reliability of QCT. The analysis included 40 cadavers with no known diseases affecting the bones. The subjects consisted of 15 females and 25 males with a mean age of 60.3 years. Spearman correlation analysis and Wilcoxon rank sum test was performed. The results were as follows. 1. There was statistically no correlation between the mandible and iliac bone in the values of corrected cortical width(CCW), cortical porosity(POR) in cortex, and total bone volume(TBV), mean trabecular plate thickness(MTPT), mean trabecular plate density(MTPD), and mean trabecular plate separation(MTPS) in trabecular bone. 2. Comparison of women and men over 60 years, men had statistically higher bone density than women except fir POR of buccal and lingual cortex, and WTPD of alveolar trabeculae in mandible. 3. There was statistically significant correlation between TBV of trabecular bone and CT No., but not between POR and CT No. in mandible. According to the results above, there was no correlation between mandible and iliac bone density and between mandibular bony density and age. Further studies are required to support the results. A more noninvasive method to be able to measure the bone density of mandible should be developed and it is necessary to accumulate data on the normal values of bone density of mandible according to age and sex. Further study should be carried out about QCT to measure mandibular bony density using QCT.

  • PDF

Students' Levels of Cognitive Conflict by Provided Quantitative Demonstration and Qualitative Demonstration (정량적 현상제시와 정성적 현장제시에 의한 학생들의 인지갈등 정도)

  • Kim, Ji-Na;Choi, Hyuk-Joon;Kwon, Jae-Sool
    • Journal of The Korean Association For Science Education
    • /
    • v.22 no.1
    • /
    • pp.12-21
    • /
    • 2002
  • The purpose of this study is to understand middle school students' levels of cognitive conflict for the students provided quantitative demonstration and qualitative demonstration after the pre-test. 297 middle school students were selected from one school in Pusan. Action-reaction problem of mechanics and electric bulbs in parallel problem of electricity were used in the demonstration and the pre-test. Students' cognitive conflict levels were investigated using the developed items by Kwon(1999) et al. We compared cognitive conflict levels between quantitative demonstration group and qualitative demonstration group. In addition to, we compared cognitive conflict levels between students who changed their preconceptions and the students who adhered to their preconceptions. We investigated correlation between levels of faith with preconceptions and cognitive conflict levels. The study generated the following results. First, students who selected incorrect choice in pre-test showed the higher levels of cognitive conflict in quantitative demonstration group than qualitative demonstration group and students who selected correct choice in pre-test showed higher levels of cognitive conflict in qualitative demonstration group than quantitative demonstration group. Second, students who changed their preconceptions were higher levels of cognitive conflict than students who adhered their preconceptions. Third, students who selected incorrect choice in pre-test showed positive correlation between levels of faith with preconceptions and levels of cognitive conflict, and students who selected incorrect choice in pre-test showed negative correlation between levels of faith with preconceptions and levels of cognitive conflict.

Quantitative Analysis of Thyroid Blood Flow and Static Imaging in the Differential Diagnosis of Thyroid Nodules

  • Song, Li-Ping;Zhang, Wen-Hong;Xiang, Yang;Zhao, Na
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6331-6335
    • /
    • 2013
  • Objective:To evaluate the performance of combined quantitative analysis of thyroid blood flow and static imaging data in the differential diagnosis of thyroid nodules. Method: Thyroid blood flow and static imaging were performed in 165 patients with thyroid nodules. Patients were divided into a benign thyroid nodule group (BTN, n=135) and a malignant thyroid nodule group (MTN, n=30) based on the results of post-surgical pathologic examination. Carotid artery thyroid transit times (CTTT), perfusion ratio of thyroid nodule blood/thyroid blood (TNB/TB), and perfusion ratio of thyroid nodule blood/carotid artery blood (TNB/CAB) were measured using thyroid blood flow imaging. The ratios between thyroid nodule and ipsilateral submandibular gland (TN/SG) and thyroid nodule and normal thyroid tissue (TN/T) were measured from thyroid static imaging. The differences between the BTN and MTN groups were compared. Results: 1) CTTT was markedly lower in the MTN group than the BTN group, the difference being statistically significant. 2) TNB/TB and TNB/CAB were both significantly higher in MTN than BTN groups. 3) TN/T was significantly lower in MTN group than BTN group. 4) TN/SG was lower in MTN group than BTN group, but the difference was not statistically significant. 5) Using the combination of CTTT and TN/T, the sensitivity, specificity and accuracy were 93.1%, 95.3% and 94.9% respectively for the diagnosis of MTN. Using the combination of CTTT, TNB/TB and TN/T, the sensitivity, specificity and accuracy changed to 89.7%, 100%, and 98.1% respectively. 6) Correlation analysis demonstrated a significant correlation between TN/T and TNB/TB (r=-0.384, P=0.036) and TNB/CAB (r=-0.466, P=0.009) in the MTN group. Conclusion: The combination of quantitative markers from thyroid blood flow and thyroid static imaging had high specificity and accuracy in differential diagnosis of benign and malignant thyroid nodules, thus providing an important imaging diagnostic approach.

Quantitative Analysis of Lower Nose and Upper Lip Asymmetry in Patient with Unilateral Cleft Lip Nose Deformity using 3D camera (3D camera를 이용한 일측성 구순비변형환자에서의 비하부 및 상구순 비대칭의 정량적 분석)

  • Oh, Tae suk;Koh, Kyung suk;Kim, Tae gon
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.702-706
    • /
    • 2009
  • Purpose: Analysis of lower nose and upper lip asymmetry in patients with unilateral cleft lip nose deformity has been proceeded through direct measurement and photo analysis. But there are limitation in presenting real image because of its 2 dimensional trait. The authors analyzed such an asymmetry using 3D VECTRA system (Canfield, NJ, USA) in quantitative way. Methods: In 25 Patients with unilateral cleft lip nose deformity(male 12, female 13, age ranging from 4 to 19), patients with right side deformity were 10 and left were 15. Analysis of asymmetry was proceeded through 3D VECTRA system. After taking 3 dimensional photo, alar area, upper lip area, nostril perimeter, nostril area, Cupid's bow length, nostril height and nostril width were measured. Correlation coefficient and inter data quotients were calculated. Results: In nostril perimeter, maximal difference of cleft side and non - cleft side was 39.3%, asymmetric quotient Qasy = Qcl/Qncl(Qcl, value of cleft side; Qncl, value of non - cleft side) was ranged from 0.84 to 1.85 and in seven cases the length of cleft side was smaller. In nostril area, maximal difference was 69.6% and in 13 cases cleft side was smaller. In lower nasal area, maximal difference was 37.2% asymmetric quotient Qasy = Qcl/Qncl was ranged from 0.47 to 2.03 and in 20 cases cleft side was smaller. The correlation coefficients of nostril perimeter and area were 0.8345. Conclusion: Using 3D VECTRA system, the authors can measure nostril perimeter and lower nasal area that could not been measured with previous methods. Asymmetry of midface was analyzed through area comparison in quantitative way. Futhermore, post operative change can be measured in quantitative method.

A study on the correlation between the result of electrical resistivity survey and the rock mass classification values determined by the tunnel face mapping (전기비저항탐사결과와 터널막장 암반분류의 상관성 검토)

  • 최재화;조철현;류동우;김학규;서백수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.265-272
    • /
    • 2003
  • In this study, the rock mass classification results from the face mapping and the resistivity inversion data are compared and analyzed for the reliability investigation of the determination of the rock support type based on the surface electrical survey. To get the quantitative correlation, rock engineering indices such as RCR(rock condition rating), N(Rock mass number), Q-system based on RMR(rock mass rating) are calculated. Kriging method as a post processing technique for global optimization is used to improve its resolution. The result of correlation analysis shows that the geological condition estimated from 2D electrical resistivity survey is coincident globally with the trend of rock type except for a few local areas. The correlation between the results of 3D electrical resistivity survey and the rock mass classification turns out to be very high. It can be concluded that 3D electrical resistivity survey is powerful to set up the reliable rock support type.

  • PDF

GALAXY CORRELATION IN A BUBBLY UNIVERSE

  • Ryu, Dong-Su
    • Publications of The Korean Astronomical Society
    • /
    • v.7 no.1
    • /
    • pp.25-30
    • /
    • 1992
  • Recent redshift surveys suggest that most galaxies may be distributed on the surfaces of bubbles surrounding large voids. To investigate the quantitative consistency of this qualitative picture of large-scale structure, we study analytically the clustering properties of galaxies in a universe filled with spherical shells. In this paper, we report the results of the calculations for the spatial and angular two-point correlation functions of galaxies. With ${\sim}20%$ of galaxies in clusters and a power law distribution of shell sizes, $n_{sh}(R){\sim}R^{-{\alpha}}$, ${\alpha}\;{\simeq}\;4$, the observed slope and amplitude of the spatial two-point correlation function ${\xi}_{gg}(r)$ can be reproduced. (It has been shown that the same model parameters reproduce the enhanced cluster two-point correlation function, ${\xi}_{cc}(r)$). The corresponding angular two-point correlation function $w({\theta})$ is calculated using the relativistic form of Limber's equation and the Schecter-type luminosity function. The calculated w(${\theta}$) agrees with the observed one quite well on small separations (${\theta}{\lesssim}2deg$).

  • PDF

A case-based reasoning application to new product launch strategy (신제품 출시 전략에의 사례기반 추론 응용)

  • 이재식;이민철
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.10a
    • /
    • pp.35-38
    • /
    • 1996
  • It's a rather difficult for new product launch strategy establishment to be settled down because we must know the correlation between the quantitative and the qualitative information. Therefore, we introduce you case-based reasoning system that use its correlation and new product launch's experience in the past. Using the real cases, this system evaluates the performance as we compare human expert's new product sales forecasting with system's.

  • PDF

Quantitative Analysis of Crack Patterns of Fiber Reinforced Cement Composites based on Fractal (프랙탈 이론에 기초한 섬유보강시멘트 복합체의 균열패턴의 정량분석)

  • 원종필;김성애
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.333-338
    • /
    • 2001
  • Fractal geometry is a non-Euclidean geometry which has been developed to quantitative analysis irregular or fractional shapes. Fractal dimension of irregular surface has fractal values ranging from 2 to 3 and of irregular line profile has fractal values ranging from 1 to 2. In this paper, quantitative analysis of crack growth patterns during the fracture processing of fiber-reinforced cement composites based on fractal geometry. The fracture behaviors of fiber reinforced mortar beams subjected to three-point loading in flexure. The beams all had a single notch depth, but varing volume fractions of polypropylene, cellulose fibers. The crack growth behaviors, as observed through the image processing system, and the box counting method was used to determine the fractal dimension, Df. The results showed that the linear correlation exists between fractal dimension and fracture energy of the fiber reinforced cement mortar.

  • PDF

Comparison of Spectral Data of Metabolites Collected from Bruker and Varian 600 MHz Spectrometers

  • Kang, Woo-Young;Chae, Young-Kee
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.13 no.1
    • /
    • pp.7-14
    • /
    • 2009
  • The spectral data were collected from the two 600 MHz spectrometers from the two major manufacturers, Broker and Varian. The samples were prepared to create standard curves for quantitative measurements of metabolite concentrations. Instead of employing one-dimensional $^1H$ experiments, the two-dimensional $^1H-^{13}C$ HSQC experiments were performed for better separation of resonances. For some resonances, the high salt condition hindered the linear correlation between the intensity and actual metabolite concentration. Excluding overlapped ones, most resonances showed good linearity. Although the Varian spectrometer showed better linearity, both spectrometers were able to generate acceptable standard curves. From this data, we could identify resonances that could be used to better quantify the concentrations of the particular metabolites. With these standard curves, the quantitative measurements of the metabolites from the real samples will be facilitated.

A Study on the Quantitative Visualization of Rayleigh-Bernard Convection Using Thermochromic Liquid Crystal (감온액정을 이용한 Rayleigh-Bernard 대류의 정량적 가시화에 관한 연구)

  • 배대석;김진만;권오봉;이동형;이연원;김남식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.395-404
    • /
    • 2003
  • Quantitative data of the temperature and velocity were obtained simultaneously by using liquid crystal tracer. PIV(Particle Image Velocimety) based on a grey-level cross-correlation method was used for visualizing and analysis of the flow field. The temperature gradient was obtained by applying the color-image processing to a visualized image, and a neural-network a1gorithm was applied to the color-to-temperature calibration. This simultaneous measurement was applied to the Rayleigh-Bernard convection. This paper describes the method, and presents the quantitative visualization of Rayleigh-Bernard convection and the effect of aspect ratio and viscosity. Also the experimental results were compared with the numerical results.