• 제목/요약/키워드: quality standard

검색결과 5,705건 처리시간 0.037초

인체건강보호를 위한 수질환경 및 먹는물 기준에 대한 외국의 도출근거 연구 : 1,4-Dioxane, Formaldehyde, Hexachlorobenzene를 대상으로 (Studies on the Derivation Basis of Surface Water Quality Standards for Human Health Protection and Drinking Water Standards in Foreign Countries: 1,4-Dioxane, Formaldehyde, and Hexachlorobenzene)

  • 곽진일;안윤주
    • 한국물환경학회지
    • /
    • 제29권6호
    • /
    • pp.842-846
    • /
    • 2013
  • In 2012, the Korean Ministry of Environment (MOE) added 3 new water quality standards for the protection of human health; specifically, regarding 1,4-dioxane, formaldehyde, and hexachlorobenzene. In this study, we assimilated the water quality standards of these 3 substances from other countries, with respect to surface water quality standards for human health protection and drinking water standards. We subsequently investigated how these standard values were derived. 1,4-Dioxane is managed as an environmental standard for human health in Japan, and as a drinking water quality standard in WHO, New Zealand, and Japan with respect to both carcinogenic and non-carcinogenic effects. In New York, the oncogenic effects of formaldehyde in drinking water intake is considered, whereas WHO, Australia, New Zealand, and Japan also assess the non-carcinogenic effects of formaldehyde when setting their standards. USEPA and New York have a water quality standard for human health protection with respect to hexachlorobenzene based on carcinogenic effects. This study focuses on deriving water quality standards for the 3 new substances, or obtaining baseline information to revise the values of existing substances in the future.

한국제조기업 품질관리활동의 동적 분석 (An Dynamic Analysis of Quality Control in Korean Manufacturing Industry)

  • 이순룡;이광재
    • 산업경영시스템학회지
    • /
    • 제10권16호
    • /
    • pp.183-195
    • /
    • 1987
  • The effectiveness of quality control is contingent to adaptability to the present circumstance. The objectives of this study are to provide empirical data to carry out qualify control effectively. To accomplish this purpose, an empirical study was made by questionaire (mailing survey method, Feb. to Mar. in 1987). The sample is the 167 companies in Korean manufacturing industry. The main findings out of the analysis are as follows the stage of quality control is concentrated in appraisal phase, the company standard is equiped gradually in non-KS marked company and the need of economic evaluation about quality control is increased gradually. With a view to analysing of relationship between quality control and it's effect factors (company standard, KS mark, computer based information system), the methods of $\chi$$^2$ test are used. The company standard have a significant difference in top manager's altitude to duality control, operation stage of quality control. operation scope of qualify control and quality budgeting system but is insignificant with economic evaluation about duality control. Otherwise, KS mark is insignificant with the equality control activity except for operation scope. The quality information system based in computer have a significant difference in operation stage, operation scope and economic evaluation. Therefor, for the purpose of attaining effectiveness of quality control through the economic evaluation about quality control, the company standard and computer based duality information system must be utilized in quality control activity.

  • PDF

RAND 방법으로 합의한 임상진료지침의 정의와 질 평가 기준 (Consensus on definition and quality standard of clinical practice guideline using RAND method)

  • 지선미;김수영;신승수;허대석;김남순
    • 보건행정학회지
    • /
    • 제20권2호
    • /
    • pp.1-16
    • /
    • 2010
  • Background : Clinical practice guidelines are an increasingly familiar part of clinical practice. Moreover, rigorously developed evidence based guidelines has been widely used. However, in Korea, some of published documents as clinical practice guidelines have shown considerable disparity in structure, contents and quality. This is mainly because there is no consensus on the definition and quality standard of clinical practice guidelines. The purpose of this study was to draw consensus on the definition and the quality standard about clinical practice guidelines. Method : We developed a questionnaire about the definition of clinical practice guidelines with inclusion criteria(23 items) and the quality standard(30 items). We selected 9 experts who had prior experience in developing and implementing guidelines. Rating methods for appropriateness of items were adopted from the RAND method. Consensus was drawn in three rounds. Results : Of the 47 items agreed, 40 items were determined to be appropriate. Clinical practice guidelines were defined as "scientifically and systematically developed statements to assist practitioners and patients on making decisions about appropriate health care for specific clinical circumstances." Narrative reviews, systematic reviews or health technology assessment without recommendations, translation of foreign guidelines, guidelines for patients only and training manuals were not considered as clinical practice guidelines. For the quality standard of clinical practice guidelines, 27 items were deemed necessary. Conclusions : The consensus on the definition with inclusion criteria and the quality standard of clinical practice guidelines carries an important meaning as the first attempt to draw a general agreement in our society. The unique achievement of the consensus reflects the current status of clinical practice guidelines that there has been a high tendency to adapt foreign guidelines. We hope efforts of this kind will continue to bring improvement in clinical practice guidelines.

연구개발 결과물의 품질 향상을 위한 연구개발 표준 프로세스 정의 및 프로젝트 프로세스 조정 (Defining and Tailoring R&D Standard Process to Improve the Quality of R&D Outcomes)

  • 류원옥;정효택
    • 대한산업공학회지
    • /
    • 제43권2호
    • /
    • pp.112-119
    • /
    • 2017
  • Korea's national R&D projects are increasing year by year. However, it is necessary to improve the quality of R&D result. In this paper, we introduce the developing and adjusting the R&D standard process based on process approach in ETRI. It is expected that the definition of R&D standard process will contribute to improve customer satisfaction and quality of R&D result through standardization and continuous improvement activities.

간호표준 적용이 근${\cdot}$골격장애 환자의 간호질에 미치는 효과 (The effect of using a Nursing Standards on the Quality of Nursing care in Musculo-skeletal Disorder Patients)

  • 최순옥
    • 간호행정학회지
    • /
    • 제9권1호
    • /
    • pp.89-101
    • /
    • 2003
  • Purpose : this study was to examine the effect of using a nursing standards for the quality of nursing care in musculo-skeletal patients. Method : The approach to nursing quality assurance evaluation was selected process-outcome framework. The subjects ware 100 case of musculo-skeletal patients in orthopedic surgery nursing care unit of E. university hospital in seoul. The data of a control group were collected from 23 December 2001 to 20 March 2002 and an experimental group were collected from 1 June to 25 August 2002. The instruments used for this study were a nursing care standards in musculo-skeletal disorder patients developed by the investigator and an evaluation tool for the quality of nursing care in orthopedic surgery patients developed by soon-ook Choi in 1995. It's reliability is Cronbach alpha=.8628. The data were analyzed by means of $x^1$-test, t-test, ANOVA with SPSS program. Results : This study are as fellows : 1. Scores of the quality of nursing care in standard 1 in the experimental group were higher than those of the control group with no significant difference(t=-8.793, p=.000), scores of the quality of nursing care in standard 2 in the experimental group were higher than those of the control group with significant difference(t=-8.793, p=.000) and standard 3 in the experimental group were higher than those of the control group with significant difference(t=-10.550, p=.000). scores of the quality of nursing care in standard 4 in the experimental group were higher than those of the control group with significant difference(t=-8.793, p=.000). scores of the quality of nursing care in standard 4 in the experimental group were higher than those of the control group with no significant difference(t=-1.833, p=.070). 2. Scores of the quality of nursing care in criteria 28 of 33 criteria in the experimental group were higher than those of the control group with significant difference in 12 criteria(p<.05 ). 3. Scores of the quality of nursing care in standard 1 to standard 4(process evaluation); the experimental group were higher than those of the control group with significant difference(t=-10.704, p=.000). scores of the quality of nursing care in standard 5(outcome evaluation); the experimental group were higher than those of the control group. but no significant difference(t=-1.833, p=.070). 4. Scores of the quality of nursing care in experimental group were higher than those of the control group with significant difference(t=-10.794, p=.000). Conclusion : Through this study, I'm sure that using a nursing care standards in musculo-skeletal disorder patients improve quality of nursing care and nursing care standards are effective nursing care.

  • PDF

국방품질경영시스템인증심사부적합및원인에관한분석연구 (A Analysis Study on Cause and Nonconformity of Certification Audit Defence Quality Management System)

  • 노재용;이상복
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2010년도 춘계학술대회
    • /
    • pp.16-23
    • /
    • 2010
  • This research analyzed about inconsistence and cause of the audit result on national defense quality management system in certification company. Direction of research analyzes corelation with distribution by items at national defense quality management system standard by Investigated number and occurrence of examination report slight and critical incongruity on 2008 and 2009. Study finding slight and critical incongruity happened to first examination average 10.2 items, renewal examination average 7.0 items. By incongruity occurrence appeared high in item that there are a lot of examination item shares of standard requirement, it was studied by correlative thing between the examination with standard. Factor of incongruity occurrence was proved to comprehension insufficiency for quality management system, quality procedure insufficiency, didn't fulfil proceedings, business was unripe. In this papers, we contribute to propose direction for improvement of national defense quality management system comprehensive faculty elevation and national defense quality certification in this treatise.

  • PDF

감자 품질평가 현황과 전망 (Prospects and Status on Quality of Potato)

  • 김숭열
    • 한국작물학회지
    • /
    • 제47권
    • /
    • pp.135-139
    • /
    • 2002
  • The standard of quality was required to promote the consumption of potato and produce the high quality processing products. It will contribute the stability for processing products and the marketability of potato. The quality was determined based on size of tuber and content of dry matter. Even though the criteria of potato quality was involved many characters of tubers, the most important things were grading and packing of potato to create the consumption. For processing of raw materials, the standard of tubers had create between producer and processor according to size of tuber and content of dry matter. The evaluation of quality was performed over the standard to enhance the control of quality. In addition, the seed potato should be taken the evaluation to disease in the field during the period of cultivation and managed under the strict regulation in storage before release to farmer. Then, the producer of seed potato will make a good relationship to farmer with high quality tubers.

연구개발 표준 프로세스의 개발­E 연구원의 사례를 중심으로­ (Development of R&D Standard Processes for E Research Institute)

  • 박종근;성기순;김해숙
    • 품질경영학회지
    • /
    • 제31권4호
    • /
    • pp.127-149
    • /
    • 2003
  • With the rapid change in today's R&D environment and the enlargement of the expected quality level for R&D outcomes, it has become increasingly necessary to effectively define the R&D standard processes tailored for our organization and projects. To meet this needs, we defined the R&D standard processes based on the standards for systems and software engineering and our traditional work methods and applied them to our ongoing projects. We will improve our defined R&D standard processes continuously by monitoring of the processes and the feedback of the application results. In this paper, we introduce the R&D standard processes developed by E Research Institute and the requirements and approaches used for their development. We compare our defined R&D standard processes with ISO/IEC 15288 which is the first international standard for systems engineering.

우리나라, 미국 및 유럽의 대기환경기준 강도에 관한 비교 연구 (A Comparative Study on the Ambient Air Quality Standard Strength among Korea, the U.S.A. and the EU)

  • 박민빈;이태정;이은선;김동술
    • 한국대기환경학회지
    • /
    • 제32권6호
    • /
    • pp.559-574
    • /
    • 2016
  • Based on air quality monitoring data ('10~'14) of Suwon City provided by the Korean Department of Environment, a fundamental statistic for 5 criteria pollutants such as $SO_2$, CO, $NO_2$, $O_3$, and $PM_{10}$ was initially investigated. The purpose of this paper was to review the ambient air quality standards(AAQS) of Korea, the U.S.A. and the EU and further to assess the degree of standard strength by the achievability of the AAQS comparing each national standard. Since the level and the way of standards for each air pollutant are various among countries, it is difficult to determine the degree of relative attainment using the same set of data above. Further when all the areas having bad air quality for a specific pollutant are classified as non-attainment case, it is more difficult to assess the degree of standard strength. Thus we introduced a new concept called the average concentration distance (ACD) to quantitatively estimate the strength. As results, the Korean 1-hr $NO_2$ AAQS is slightly stronger than the US standard and weaker than the EU standard. The Korean $O_3$ standard is strongest; however, the Korean $PM_{10}$ standard is weakest. Furthermore the equivalent levels of 8-hr $O_3$ standards in the U.S.A. and the EU were respectively estimated as 97.5 and 95.7 percentiles of the Korean standard with maintaining the existing standard of 60 ppb.

강재 파이프서포트의 압축하중 시험에 따른 안전 및 품질관리 기준 개선에 관한 연구 (A Study on Improvement of Safety & Quality Management Standard Based on Compression Tests of Steel Pipe Supports)

  • 오병한;최병정
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.94-103
    • /
    • 2018
  • As of July 1, 2017, the method of quality management of construction equipment had been changed completely. In case of manufacturing and distributing pipe supports, the support length according to the safety certification standard shall be not more than 6 m and the compressive strength shall be not less than 40,000 N at the maximum height. However, the field tests for the quality control standard were usually performed at 3.5 m when the length of the pipe supports is 3.5 m to 4.0 m, and the compression strength was specified to be more than 35,300 N. This difference in the two standards can cause confusion in practice. In this study, the compression load of the pipe supports was tested and found to be more than 30% defective. Therefore, it is necessary to review the modification of the safety certification and quality standards to improve the standard requirements.