• Title/Summary/Keyword: quality measurement

Search Result 4,470, Processing Time 0.032 seconds

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

A Study of variables Related to Nursing Productivity (간호생산성에 관한 연구: 관련변수의 검증을 중심으로)

  • 박광옥
    • Journal of Korean Academy of Nursing
    • /
    • v.24 no.4
    • /
    • pp.584-596
    • /
    • 1994
  • The objective of the study is to explore the relationships between the variables of nursing productivity on the framework of system del in the tertiary university based care hospital in Korea. Productivity is basically defined as the relation-ship between inputs and outputs. Under the proposition that the nursing unit is a system that produces nursing care output using personal and material resources through the nursing intervention and nursing care management. And this major conception of nursing productivity system comproises input, process and output and feed-back. These categorized variables are essential parts to produce desirable and meaningful out-put. While nursing personnel from head nurse to staff nurses cooperate with each other, the head nurse directs her subordinates to achieve the goal of nursing care unit. In this procedure, the head nurse uses the leadership of authority and benevolence. Meantime nursing productivity will be greatly influenced by environment and surrounding organizational structures, and by also the operational objectives, the policy and standards of procedures. For the study of nursing productivity one sample hospital with 15 general nursing care units was selected. Research data were collected for 3 weeks from May 31 to June 20 in 1993. Input variables were measured in terms of both the served and the server. And patient classification scores were measured drily by degree of nursing care needs that indicated patent case-mix. And also nurses' educational period for profession and clinical experience and the score of nurses' personality were measured as producer input variables by the questionnaires. The process varialbes act necessarily on leading input resources and result in desirable nursing outputs. Thus the head nurse's leadership perceived by her followers is defined as process variable. The output variables were defined as length of stay, average nursing care hours per patient a day the score of quality of nursing care, the score of patient satisfaction, the score of nurse's job satis-faction. The nursing unit was the basis of analysis, and various statistical analyses were used : Reliability analysis(Cronbach's alpha) for 5 measurement tools and Pearson-correlation analysis, multiple regression analysis, and canonical correlation analysis for the test of the relationship among the variables. The results were as follows : 1. Significant positive relationship between the score of patient classification and length of stay was found(r=.6095, p.008). 2. Regression coefficient between the score of patient classification and length of stay was significant (β=.6245, p=.0128), and variance explained was 39%. 3. Significant positive relationship between nurses’ educational period and length of stay was found(r=-.4546, p=.044). 5. Regression coefficient between nurses' educational period and the score of quality of nursing care was significant (β=.5600, p=.029), and variance explained was 31.4%. 6. Significant positive relationship between the score of head nurse's leadership of authoritic characteristics and the length of stay was found (r=.5869, p=.011). 7. Significant negative relationship between the score of head nurse's leadership of benevolent characteristics and average nursing care hours was found(r=-.4578, p=.043). 8. Regression coefficient between the score of head nurse's leadership of benevolent characteristics and average nursing care hours was significant(β=-.6912, p=.0043), variance explained was 47.8%. 9. Significant positive relationship between the score of the head nurse's leadership of benevolent characteristics and the score of nurses' job satis-faction was found(r=.4499, p=050). 10. A significant canonical correlation was found between the group of the independent variables consisted of the score of the nurses' personality, the score of the head nurse's leadership of authoritic characteristics and the group of the dependent variables consisted of the length of stay, average nursing care hours(Rc²=.4771, p=.041). Through these results, the assumed relationships between input variables, process variable, output variables were partly supported. In addition it is also considered necessary that-further study on the relationships between nurses' personality and nurses' educational period, between nurses' clinical experience including skill level and output variables in many research samples should be made.

  • PDF

Development of a Method to Measure the Radiation Isocenter Size of Linear Accelerators and Quantitative Analysis of the Radiation Isocenter Size for Clinac 21EX Linear Accelerator (선형가속기 방사선 중심점의 크기 측정 방법 개발과 Clinac 21EX 선형가속기의 방사선 중심점 크기 분석)

  • Jeon, Ho-Sang;Nam, Ji-Ho;Park, Dahl;Kim, Yong-Ho;Kim, Won-Taek;Kim, Dong-Won;Ki, Yong-Kan;Kim, Dong-Hyun
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.131-139
    • /
    • 2011
  • A method to get a size of the radiation isocenter of linear accelerators using star-shot images was presented and a computer program was developed to automate the method. Accuracy of the method was verified. The developed program was used to measure sizes of the radiation isocenters for a Clinac 21EX (Varian, USA) using data of quality assurance (QA) performed from June 2008 to December 2010. To calculated the size of radiation isocenter, positions of two points on each central ray of the star-shot image were found and the equation of the central ray was determined using the positions of two points. Using the equations of central rays the radius of the minimum circle intersecting all the central rays, which is one half of the size of radiation isocenter, was calculated. The program measured x-intercepts and y-intercepts of the central rays within errors of 0.084 mm and sizes of radiation isocenters within 0.053 mm. All the errors were less than the spatial resolution of star-shot images 0.085 mm. The radiation isocenter sizes of Clinac 21EX were $0.33{\pm}0.27mm$, $0.71{\pm}0.36mm$, $0.50{\pm}0.16mm$ for collimator, gantry and couch respectively. During the measurement period all the measured sizes were less than 2.0 mm and within tolerance. The developed program could calculate the size of radiation isocenters and it would be helpful to routine QA.

Reading Deviations of Glass Rod Dosimeters Using Different Pre-processing Methods for Radiotherapeutic in-vivo Dosimetry (유리선량계의 전처리 방법이 방사선 치료 선량 측정에 미치는 영향)

  • Jeon, Hosang;Nam, Jiho;Park, Dahl;Kim, Yong Ho;Kim, Wontaek;Kim, Dongwon;Ki, Yongkan;Kim, Donghyun;Lee, Ju Hye
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.92-98
    • /
    • 2013
  • The experimental verification of treatment planning on the treatment spot is the ultimate method to assure quality of radiotherapy, so in-vivo skin dose measurement is the essential procedure to confirm treatment dose. In this study, glass rod dosimeter (GRD), which is a kind of photo-luminescent based dosimeters, was studied to produce a guideline to use GRDs in vivo dosimetry for quality assurance of radiotherapy. The pre-processing procedure is essential to use GRDs. This is a heating operation for stabilization. Two kinds of pre-processing methods are recommended by manufacturer: a heating method (70 degree, 30 minutes) and a waiting method (room temperature, 24 hours). We equally irradiated 1.0 Gy to 20 GRD elements, and then different preprocessing were performed to 10 GRDs each. In heating method, reading deviation of GRDs at same time were relatively high, but the deviation was very low as time went on. In waiting method, the deviation among GRDs was low, but the deviation was relatively high as time went on. The meaningful difference was found between mean reading values of two pre-processing methods. Both methods present mean dose deviation under 5%, but the relatively high effect by reading time was observed in waiting method. Finally, GRD is best to perform in-vivo dosimetry in the viewpoint of accuracy and efficiency, and the understanding of how pre-processing affect the accuracy is asked to perform most accurate in-vivo dosimetry. The further study is asked to acquire more stable accuracy in spite of different irradiation conditions for GRD usage.

One Year Follow-up for Successfully Treated Children with Accommodative Dysfunction (조절이상이 성공적으로 치료된 어린이에 대한 1년 후의 추적검사)

  • Shin, Hoy Sun;Youk, Do Jin;Sung, Duk Yong;Park, Sang Chul;Lee, Sun Haeng
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.169-174
    • /
    • 2010
  • Purpose: The purpose of this study is to evaluate the long-term stability of the improved symptoms and accommodative functions after completion of accommodative therapy. Methods: Seven children (mean age${\pm}$SD: $12{\pm}1.41$ years) who were successfully treated with a vision therapy program for either accommodative insufficiency or infacility were followed for 1 year. The visual symptoms of the subjects were measured by the College of Optometrists in Vision Development Quality of Life (COVD-QOL) checklist, and this was followed by measurement of the monocular and binocular accommodative facility with ${\pm}2.00$ D flipper lens. Results: The mean visual symptoms at the 1 year follow-up examination ($15.14{\pm}8.59$) showed a small increase, but there was no significant difference (p=0.446) from post-therapy ($11.86{\pm}7.22$). There was small regression in the monocular (left eye, $13.86{\pm}3.93cpm$) and binocular ($11.14{\pm}3.13cpm$) accommodative facility at the 1 year follow-up examination, but there were no significant different from the monocular ($15.86{\pm}4.14cpm$, p=0.147) and binocular ($13.21{\pm}3.76cpm$, p=0.066) accommodative facility measurements at post-therapy. Also, every subject met the normative values of ${\geq}7$ cpm for monocular accommodative facility and ${\geq}5$ cpm for binocular accommodative facility in the long-term. Conclusions: There was long-term maintenance of the improved visual symptoms and accommodative functions, and so it is clear that the positive therapeutic effects persist with accommodative therapy.

Comparison of pH, Water Holding Capacity and Color among Meats from Korean Native Chickens

  • Jung, Samooel;Kim, Hyun Joo;Lee, Hyun Jung;Seo, Dong Won;Lee, Jun Heon;Park, Hee Bok;Jo, Cheorun;Nam, Ki Chang
    • Korean Journal of Poultry Science
    • /
    • v.42 no.2
    • /
    • pp.101-108
    • /
    • 2015
  • This study investigated the initial pH measured at 15 min post-mortem, ultimate pH, water holding capacity (WHC), and color of meats obtained from five lines of Korean native chicken (KNC) for the development of breed for high-quality meat. In addition, the effect of sex was examined. In total, 595 $F_1$ progeny (Black [B], Grey-Brown [G], Red-Brown [R], White [W] and Yellow-Brown [Y]) from 70 full-sib families were used. Chickens were slaughtered at 20 wk of age and the measurement traits of all breast and thigh meats from 595 chickens were analyzed. The initial pH at 15 min post-slaughter of the breast and thigh meats was affected by the line and sex of Korean native chicken (P<0.05). However, there was no line and sex effect on ultimate pH and WHC of the breast and thigh meat except that the ultimate pH of thigh meat had line effect. Except for the $L^*$ value of breast meat, the meat color was significantly affected by line and sex (P<0.05). The ultimate pH showed consistently negative correlation with the $L^*$ value and positive correlation with the $a^*$ value in breast and thigh meats. Based on the results, we concluded that the line W in male chickens and the line G and W in female chickens may be good candidates for the selection to develop breed for high-quality meat because these lines showed property of high initial pH or/and ultimate pH.

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.

Validation of the Korean Version of the St. George's Respiratory Questionnaire for Patients with Chronic Respiratory Disease (한국어판 세인트조지 호흡기설문의 타당도와 신뢰도 검정)

  • Kim, Young Sam;Byun, Min Kwang;Jung, Wou Young;Jeong, Jae Hee;Choi, Sang Bong;Kang, Shin Myung;Moon, Ji Ae;Han, Jung Suk;Nam, Chung-Mo;Park, Moo Suk;Kim, Se Kyu;Chang, Joon;Ahn, Chul Min;Kim, Sung Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.2
    • /
    • pp.121-128
    • /
    • 2006
  • Background: The "health-related quality of life" (HRQL) for patients with chronic respiratory disease has been emphasized, because chronic respiratory disease (CRD) is chronic and progressive, and it finally causes disability. HRQL instruments may be useful for monitoring patients' progress or for determining the most appropriate choice of treatment. We describe the adapting St George's Respiratory Questionnaire (SGRQ), which is a self-administered questionnaire developed by Jones et al. (1991), into the Korean version for covering three domains of health for the patients suffering with airways disease. Method: We obtained the original SGRQ from the author after gaining permission. For adaptation, we created an expert panel and translated the original questionnaire into Korean language. The translated questionnaire was then back-translated by bilingual experts and we compared it with the original questionnaire. After correction and feasibility testing, 74 patients with chronic respiratory disease (COPD, asthma, destroyed lung) completed the Korean version of the SGRQ. The clinical status of each patients was evaluated concurrently with measurement of their health status. Result: The Korean version of the SGRQ was acceptable and easy to understand. Cronbach's alpha reliability coefficient was 0.92 for the overall scale and 0.63 for the "Symptoms", subscale, 0.87 for the "Activity", subscale, and 0.89 for the "Impacts" subscales. The correlation coefficients between the overall score and the Borg scale score, oxygen saturation, and forced expiratory volume in one second ($FEV_1$) were 0.52, -0.32 and -0.26, respectively. These results support that the Korean SGRQ was correlated with other measurements. Conclusion: The Korean SGRQ was reliable and valid for patients with chronic respiratory disease, such as COPD, asthma, and destroyed lung. The SGRQ score was well correlated with other respiratory measurements as well. Although further studies should complete the adaptation work, our results suggest that the SGRQ may be used in Korea and also for international studies involving Korean CRD patients.

A Study of Family Caregiver's Burden for the Terminally III Patients (지역사회 말기질환자 가족 부담감에 관한 연구)

  • Han, Sung-Suk;Ro, You-Ja;Yang, Soo;Yoo, Yang-Sook;Kim, Sek-Il;Hwang, Hee-Hyung
    • Journal of Home Health Care Nursing
    • /
    • v.10 no.1
    • /
    • pp.58-72
    • /
    • 2003
  • The purpose of this study was to describe the perceived burden of the terminally III patients's caregiver and to analyze relationship between the perceived burden and the various demographics, illness characteristics, family relationships, and economic factor of the family & patients. The sample of 132 caregivers who care for the terminally III patients Kyung-Gi province, Seoul, Korea. The period of this study was from August to September, 2002. The perceived burden of the family caregiver was measured by the burden scale(20 items, 4 point scale) developed by Montgomery et al. (1985). The Data was analyzed using SAS-program by t-test and ANOVA. The results were as follows; 1. The mean of the family caregiver's burden score was 3.02. The score showed that caregivers perceive severe the level of burden. The hight items of the family caregiver's burden were' I feel it is painful to watch patient's diseases'(3.77). 'I feel afraid for what the future holds for my patients'(3.66), 'I feel it reduced to amount of privacy time'(3.64). 2. The caregiver's burden was significantly related to patient's gender(F=3.17, p= 0.0020), patient's job(F=2.49, p=0.0476), caregiver's age(F=4.29, p=0.0030), and caregiver's job(F=2.49, p=0.0476). 3. The caregiver's burden according to illness characteristics showed no significant difference. 4. The caregiver's burden was significantly associated with patient's family relationship (F=4.05, p=0.0041), patient's care mean period in a day(F=47.18,

  • PDF

Research on the Quality Properties of Olive Oils Available in Korea (국내 유통되는 올리브오일의 품질특성 실태조사)

  • Kim, Hyeon-Wee;Bae, Soo-Kyung;Yi, Hai-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1064-1071
    • /
    • 2003
  • An investigation of various olive oils available in Korea was carried out to assess their quality properties such as color, oxidative stability, fatty acid composition, tocopherol content, sterol content and benzo(a)pyrene content. In color measurement, by using a Lovibond color scale and Hunter color difference meter, both a and b values of extra virgin olive oil were higher than those of pure olive oil by Tintometer (Lovibond PFX995). However, extra virgin olive oil showed higher a value and lower L value than pure olive oil by the Hunter color difference meter. In the rancimat test, the induction period of extra virgin olive oil $(38.03{\sim}8.47hr)$ was longer than that of pure olive oil $(32.40{\sim}9.94hr)$. In fatty acid composition, C18:1 $(72.01{\sim}78.53wt%)$ was present in the greatest amount, with lesser amounts of C18:2 $(4.88{\sim}10.36wt%)$ and C18:3 $(0.56{\sim}1.09wt%)$. The tocopherol content ranged from ${\alpha}-Toc\;4.09{\sim}13.89mg/100g$, ${\beta}-Toc\;0.57{\sim}1.34mg/100g$, and ${\gamma}-Toc$ $3.41{\sim}8.03mg/100g$, and ${\alpha}-tocopherol$ was found to be the main isomer in all oil samples. Therefore, there was little difference in the fatty acid composition and tocopherol content among the different types of olive oils. In sterol content, ${\beta}-sitosterol$ $(124.52{\sim}19.33mg/100g)$ and campesterol $(1.10{\sim}0.62mg/100g)$ of extra virgin olive oil were higher than that of pure olive oil $({\beta}-sitosterol\;92.68{\sim}17.44mg/100g,\;campesterol\;0.59{\sim}0.35mg/100g)$. Benzo(a)pyrene was found in almost all samples, with $0.287{\sim}0.106{\mu}g/kg$ in extra virgin olive oil and $1.204{\sim}2.130{\mu}g/kg$ in pure olive oil.