• Title/Summary/Keyword: quality coefficient

Search Result 2,436, Processing Time 0.036 seconds

Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator (CLINAC 1800 선형가속기의 15 MV X-선의 특성)

  • Kim, Kye-Jun;Lee, Jong-Young;Park, Kyung-Ran
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.131-141
    • /
    • 1991
  • A comprehensive set of dosimetric measurements has been made on the Varian Clinac 1800 15 MV photon beam. Beam quality, percentage depth dose, dose in the build up region, output, symmetry and flatness, transmission through iead (Cerrobend), tray attenuation, isodose curves for the open and wedged fields were measured using 3 dimensional water phantom dosimetry system (including film densitometer system) and polystyrene phantoms. These dosimetric measurements sufficiently characterized the beam to permit clinical use. The depth dose characteristics of photon beam is $d_{max}$ of 3.0 cm and percentage depth dose of $76.8\%$ at 10 cm,100 cm source-surface distance, field size of $10\times10\;cm^2$ for 15 MV X-ray beam. The Output factors ranged 0.927 for $4\times4\;cm^2$ field to 1,087 for $35\times35\;cm^2$ field. The build-up level of maximum dose was at 3.0 cm and surface dose was approximately $15.5\%$ for a field size $10\times10\;cm^2$ The stability of output is $within\pm1\%$ and flatness and symmetry are $within\pm3\%$. The half value thickness (HVL) of lead is 13 mm, which corresponds to an attenuation coefficient of $0.053\;mm^{-1}$. These figures compare facorably with the manufacturesr`s specifications.

  • PDF

Photosynthetic Characteristics and Primary Production by Phytoplankton with Different Water Quality of Influent in Open Waters of Constructed Wetlands for Water Treatment (수질정화용 인공습지 개방수역에서 유입수질에 따른 식물플랑크톤의 광합성특성 및 유기물생산력)

  • Choi, Kwang-Soon;Hwang, Gil-Son;Kim, Dong-Sub;Kim, Sea-Won;Kim, Ho-Joon;Joh, Seong-Ju;Park, Je-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.1
    • /
    • pp.61-71
    • /
    • 2007
  • The photosynthetic characteristics and primary production by phytoplankton in open waters of two wetlands (the Banwol and the Donghwa wetland) of Sihwa Constructed Wetland with different water chemistry were investigated to provide the information for the wetland management considering the water treatment efficiency. During the study period (from March to October, 2005) the primary productivity in open waters ranged from 481 to 11,275 mgC $m^{-2}$ $day^{-1}$, which is very high compared with the eutrophic level of 600mgC $m^{-2}$ $day^{-1}$. From the analysis of the photosynthesis-irradiance (P-I) model parameters, the photosynthetic characteristics may be affected by different concentration and ratio of nutrient (N and P) between two wetlands. Assimilation number (AN) was higher in the Donghwa wetland (average AN: 8.5gC $gChl^{-1}$ $hr^{-1}$) with high P and low N/P ratio than the Banwol wetland (average AN: 5.8gC $gChl^{-1}$ $hr^{-1}$) with high N and high N/P ratio. This result indicates that AN may be concerned with phosphorus than nitrogen and low NIP ratio. Positive correlation (R=0.81) was observed between the initial slope and AN, implying that AN was high in case of phytoplankton having more active photosynthesis ability under low light. On the other hand, maximum photosynthesis (Pmax) was related positively with chlorophyll a concentration showing correlation coefficient of 0.47. In this study, considering the high primary production through phytoplankton photosynthesis in open waters of Sihwa Constructed Wetland, the produced organic matter by phytoplankton may affect the water quality within wetland and its efficiency of water treatment. Also, the photosynthetic characteristics may be affected by different nutrient enrichment (especially phosphorus) of wetlands. This study suggests that the production by phytoplankton and its characteristics in open water of constructed wetland for water treatment should be considered to improve the removal efficiency of organic matter.

Effect of Sample Preparations on Prediction of Chemical Composition for Corn Silage by Near Infrared Reflectance Spectroscopy (시료 전처리 방법이 근적외선분광법을 이용한 옥수수 사일리지의 화학적 조성분 평가에 미치는 영향)

  • Park Hyung-Soo;Lee Jong-Kyung;Lee Hyo-Won;Hwang Kyung-Jun;Jung Ha-Yeon;Ko Moon-Suck
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.26 no.1
    • /
    • pp.53-62
    • /
    • 2006
  • Near infrared reflectance spectroscopy (NIRS) has been increasingly used as a rapid, accurate method of evaluating some chemical compositions in forages. Analysis of forage quality by NIRS usually involves dry ground samples. Costs might be reduced if samples could be analyzed without drying or grinding. The objective of this study was to investigate effect of sample preparations and spectral math treatments on prediction ability of chemical composition for corn silage by NIRS. A population of 112 corn silage representing a wide range in chemical parameters were used in this investigation. Samples of com silage were scanned at 2nm intervals over the wavelength range 400-2500nm and the optical data recorded as log l/Reflectance(log l/R) and scanned in overt-dried grinding(ODG), liquid nitrogen grinding(LNG) or intact fresh(IF) condition. Samples were analysed for neutral detergent fiber(NDF), acid detergent fiber(ADF), acid detergent lignin(ADL), crude protein(CP) and crude ash content were expressed on a dry-matter(DM) basis. The spectral data were regressed against a range of chemical parameters using modified partial least squares(MPLS) multivariate analysis in conjunction with four spectral math treatments to reduce the effect of extraneous noise. The optimum calibrations were selected on the basis of minimizing the standard error of cross validation(SECV). The results of this study show that NIRS predicted the chemical parameters with very high degree of accuracy(the correlation coefficient of cross validation$(R^2cv)$ range from $0.70{\sim}0.95$) in ODG. The optimum equations were selected on the basis of minimizing the standard error of prediction(SEP). The Optimum sample preparation methods and spectral math treatment were for ADF, the ODG method using 2,10,5 math treatment(SEP = 0.99, $R^2v=0.93$), and for CP, the ODG method using 1,4,4 math treatment(SEP = 0.29. $R^2v=0.91$).

Characteristics and Risk Assessment of Heavy Metals in the Stormwater Runoffs from Industrial Region Discharged into Shihwa Lake (시화호 산업지역 강우유출수 내 중금속 유출특성 및 위해성 평가)

  • Ra, Kongtae;Kim, Joung-Keun;Lee, Jung-Moo;Lee, Seung-Yong;Kim, Eun-Soo;Kim, Kyung-Tae
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.4
    • /
    • pp.283-296
    • /
    • 2014
  • The distribution of heavy metals in the stormwater runoffs from industrial sites around Shihwa Lake that implements the total pollutant load management system (TPLMS) was studied to characterize the temporal changes of metal concentrations and to assess the ecological risk in dissolved and particulate phases of the selected metals. The dissolved Co and Ni concentration demonstrated first flush and tended to decrease with increasing of the duration of rainfall. The intensity of precipitation was found to be the main controlling factor of particulate metals in the stromwater runoffs. The particulate concentration of Pb accounted for 97.2% so the particulate phase was its main form. Other metals followed the sequence: Pb>Cu>Cd>Co>Zn>Ni. The particulate-dissolved partitioning coefficient ($K_d$) indicated that the $K_d$ of Pb were bigger than that of other metals because the metal Pb in the stormwater runoffs is quickly removed into the particulate phase. In a single day rainfall event, total runoff fluxes for total metals as the sum of dissolved and particulate forms through only two sewer outlets were 2.21 kg for Co, 30.5 kg for Ni, 278.3 kg for Cu, 398.3 kg for Zn, 0.39 kg for Cd and 40.0 kg for Pb, respectively. Given the annual rainfall, the number of rain days and the basin area for total pollutant load management system (TPLMS) of Shihwa area, enormous amount of non-point metal pollutants were entered into Lake with any treatment. The dissolved metals (e.g., Ni, Cu and Zn) in the stormwater runoffs exceeded the acute water quality criteria. Additionally, all metals were significantly enriched in the particulate phase and exceeded the PEL criteria of sediment quality guidelines (SQGs). These results indicated that the heavy metals in the stormwater runoffs may pose a very high ecological risk to the coastal environments and ecosystem.

Determination of Appropriate Exposure Angles for the Reverse Water's View using a Head Phantom (두부 팬텀을 이용한 Reverse Water's View에 관한 적절한 촬영 각도 분석)

  • Lee, Min-Su;Lee, Keun-Ohk;Choi, Jae-Ho;Jung, Jae-Hong
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.187-195
    • /
    • 2017
  • Early diagnosis for upper facial trauma is difficult by using the standard Water's view (S-Water's) in general radiograph due to overlapping of anatomical structures, the uncertainty of patient positioning, and specific patients with obese, pediatric, old, or high-risk. The purpose of this study was to analyze appropriate exposure angles through a comparison of two different protocols (S-Water's vs. reverse Water's view (R-Water's)) by using a head phantom. A head phantom and general radiograph with 75 kVp, 400 mA, 45 ms 18 mAs, and SID 100 cm. Images of R-Water's were obtained by different angles in the range of $0^{\circ}$ to $50^{\circ}$, which adjusted an angle at 1 degree interval in supine position. Survey elements were developed and three observers were evaluated with four elements including the maxillary sinus, zygomatic arch, petrous ridge, and image distortion. Statistical significant analysis were used the Krippendorff's alpha and Fleiss' kappa. The intra-class correlation (ICC) coefficient for three observers were high with maxillary, 0.957 (0.903, 0.995); zygomatic arch, 0.939 (0.866, 0.987); petrous ridge, 0.972 (0.897, 1.000); and image distortion, 0.949 (0.830, 1.000). The high-quality image (HI) and perfect agreement (PA) for acquired exposure angles were high in range of the maxillary sinus ($36^{\circ}-44^{\circ}C$), zygomatic arch ($33^{\circ}-40^{\circ}$), petrous ridge ($32^{\circ}-50^{\circ}$), and image distortion ($44^{\circ}-50^{\circ}$). Consequently, an appropriate exposure angles for the R-Water's view in the supine position for patients with facial trauma are in the from $36^{\circ}$ to $40^{\circ}$ in this phantom study. The results of this study will be helpful for the rapid diagnosis of facial fractures by simple radiography.

Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT - (복부-골반 CT검사 시 피폭선량 최적화에 관한 프로토콜 연구)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.245-251
    • /
    • 2017
  • This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using $CTDI_{VOL}$, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In $CTDI_{VOL}$ value, the 2 phase showed 26% decrease in abdomen, 1.8~59.5% decrease in pelvis for 100~250 mA, 12.7%~30% increase in pelvis for 300~400 mA. Also, DLP value showed 53% decrease in abdomen and 41~81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200~250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2 phase exam for smaller exposure dose with same image quality.

A Comparative Study regarding Health Condition and Work Stress of Nurses Working in Cancer Ward and General Ward (암병동간호사와 일반병동간호사의 건강상태와 직무스트레스 비교 연구)

  • Kim, Hyun-Sook
    • Asian Oncology Nursing
    • /
    • v.1 no.2
    • /
    • pp.191-203
    • /
    • 2001
  • The health of a nurse is very important because her mental and physical health can influence toward nursing patients directly, Especially, Cancer patients are growing annually. Also, terminal cancer patients' nursing and dead place are increasingly using hospital and the period of nursing for cancer patients are increasing. Nursing for cancer patients are different with acute disease. Therefore, I analysed comparing nurses' health working in cancer and general ward so that nurses working at cancer ward could be developed as a professional nurse, and I wanted to establish the foundation of nursing administration and reasonable manpower management to supply good quality of nursing to patients. In my research, I selected 117 nurses working in cancer ward and 134 nurses working in general word to analyse the stress rate and nurse's health comparing nurses working in general ward and cancer ward. The survey was conducted of nurses working in cancer ward nurses in 2 university hospitals, nurses working in a cancer hospital, and general ward nurses working in 3 public hospital. Also, the data was collected from Sep. 13, 2001 to Sep. 28, 2001. As health measuring tool, I used Cornell Medical Index(CMI) which are developed to fit Koreans by Ko Ungrin and Park Hang-bas (1980) using Cornell Medical Services which were designed by Weiser, Brosman, Mittelman, Wechler, Wolff in Cornell University(1945). As working stress measuring tool, I used Questionaries which were designed by Kim Mae-ja and Ku Mi-ok(1984) and then developed by Bae In-sook(1996). For managing the data, I used frequency, percentage, ${\chi}^2$ verification, t-test, and F-test (ANOVA). And in the case of significant data(p<.05). I did Duncan's test for post verification. The mutual relation between health condition and working stress rate have been conducted using Pearson's Correlation Coefficient. Followings are the results of my research. 1. Two groups showed significant differency at age after testing homogeneous character between two groups (${\chi}^2$ =9.919, p=.007). 2. Comparing two group's health condition, cancer ward(average 19.35${\pm}$18.34) were higher than general ward(14.42${\pm}$10.59) and showed statistical significant differency(p=.009). And, comparing two group's mental condition, cancer ward(9.00${\pm}$9.79) were higher than general ward(7.13${\pm}$6.35) and statistically no differency. 3. After comparing two group's working stress rate, the rate of cancer ward nurse's working stress(3.36${\pm}$.50) is higher than general ward nurse (3.32${\pm}$.48). There are no significant differency. However, in the detailed verification test, there were significant differency at inappropriate compensation (t=3.254, p=.001) and medication issue (t=2.170, p=.031). 4. After comparing health condition at general points, physical health condition showed significant differency at age(p=.020), the number of children (p=.015), religion (p=.015), position(p=.005), career(p=.008), working satisfaction(p=.003), activity after office hour(p=.045); and mental health condition showed significant differency at position(p=.010), career (p=.017), working satisfaction (p=.003). 5. After comparing the working stress rate according to general points, there were significant differency at working satisfaction (F=5.285, p=.006), predicted nursing(F=3.822, p=.023). 6. At the relation of health condition and working stress rate between two groups. physical and mental condition showed significant relation with working stress rate. i.e, if a nurse's health condition is not good, she are feeling much more stress than others. After considering all the factors in my research, I found that the health condition and stress rate of cancer ward nurses is much higher than general ward nurses. Considering that cancer ward nurses is necessary to care for increasing cancer patients with mental and physical nursing, the less stress for cancer ward nurses is very important to develop nursing quality and working efficiency by keeping good health condition, specializing cancer ward nurses. Therefore, we need following studies to find the factors which are effecting to cancer ward nurses' health and specialization. Also, we need to improve managing working condition to decrease working stress by improving working condition.

  • PDF

A Study on the Technology Collaboration between the Main Supplier and Buyer under the Dynamic Environment: The Focus on the Performance of New Product Development (역동적 환경 하에 구매사/주공급사 간의 기술협력은 신제품 개발 프로젝트 성과를 향상시키는가?)

  • Lee, Younsuk;Ham, Minjoo;Moon, Seongwuk
    • Journal of Technology Innovation
    • /
    • v.23 no.3
    • /
    • pp.397-432
    • /
    • 2015
  • This paper investigates the effects of technology collaboration between the main supplier and buyer on buyer's new product development under dynamic environment. Based on 428 Korean manufacturing firms, we conducted regression analysis. The technology collaboration between the main supplier and buyer is adopted as a independent variable and quality, cost and lead time performance of new product development projects are used as dependents variables. Environment dynamic is also used as a moderate variables. We found that the in general, technology collaboration is positively associated with the performance of buyers' new product development, but in the high degree of dynamic environment, technology collaboration is negatively associated with the performance of buyers' new product development unlike our expectation. Thus, we divide our sample into two groups; shipbuilding industry with the low degree of environment dynamic and electronic and IT device industry with the high degree of environment dynamic and conducted a post hoc analysis. As a result, in ship building industry, the technology collaboration is significant to improve NPD projects performance, while in electronic and IT device industry, the technology collaboration with a main supplier is not significant as well as coefficient is negative. In that, under the highly dynamic condition with the fast change of technology and products obsolescence the NPD collaboration with the main supplier does not works unlike a stable environment. This implies that the NPD attributes of buyer are different by their environmental factor and the fit between given environmental feature and the collaboration synergy is critical factor for improving the effect of NPD collaboration between supplier and buyer.

Analysis on Longitudinal Dose according to Change of Field Width (선속 폭(Field Width) 변화에 따른 종축선량 분석)

  • Jung, Won-Seok;Back, Jong-Geal;Shin, Ryung-Mi;Oh, Byung-Cheon;Jo, Jun-Young;Kim, Gi-Chul;Choi, Tae-Gu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.109-117
    • /
    • 2011
  • Purpose: To analyze the accuracy of tumor volume dose following field width change, to check the difference of dose change by using self-made moving car, and to evaluate practical delivery tumor dose when tomotherapy in the treatment of organ influenced by breathing. Materials and Methods: By using self-made moving car, the difference of longitudinal movement (0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm) was applied and compared calculated dose with measured dose according to change of field width (1.05 cm, 2.50 cm, 5.02 cm) and apprehended margin of error. Then done comparative analysis in degree of photosensitivity of DQA film measured by using Gafchromic EBT film. Dose profile and Gamma histogram were used to measure degree of photosensitivity of DQA film. Results: When field width were 1.05 cm, 2.50 cm, 5.02 cm, margin of error of dose delivery coefficient was -2.00%, -0.39%, -2.55%. In dose profile of Gafchromic EBT film's analysis, the movement of moving car had greater motion toward longitudinal direction and as field width was narrower, big error increased considerably at high dose part compared to calculated dose. The more field width was narrowed, gamma index had a large considerable influence of moving at gamma histogram. Conclusion: We could check the difference of longitudinal dose of moving organ. In order to small field width and minimize organ moving due to breathing, it is thought to be needed to develop breathing control unit and fixation tool.

  • PDF

Microwave Dielectric Properties of $PbWO_{4}-TiO_{2}-CuO-B_{2}O_{3}$ Ceramics ($PbWO_{4}-TiO_{2}-CuO-B_{2}O_{3}$ 세라믹의 고주파 유전특성)

  • 이경호;최병훈
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.143-148
    • /
    • 2001
  • PbWO$_4$ can be densified at 85$0^{\circ}C$ and it shows fairy good microwave dielectric properties; dielectric constant($\varepsilon$$_{r}$) of 21.5, quality factor(Q $\times$f$_{0}$) of 37,224 GHz, and temperature coefficient of resonant frequency($\tau$/suf f/) of -31ppm/$^{\circ}C$. Due to its low sintering temperature, PbWO$_4$ can be used as a multilayered chip component at microwave frequency with high electrical performance by using high conductive electrode metals such as Ag and Cu. However, in order to use this material for microwave communication devices, the $\tau$$_{f}$ of PbWO$_4$ must be stabilized to near zero with high Q$\times$f$_{0}$. In present study, PbWO$_4$ was modified by adding TiO$_2$, B$_2$O$_3$, and CuO in order to improve the microwave dielectric properties without increasing the sintering temperature. The addition of TiO$_2$ increased the $\tau$$_{f}$ and $\varepsilon$$_{r}$, due to its high rr(200ppm/$^{\circ}C$) and $\varepsilon$$_{r}$(100). However, the addition of TiO$_2$ reduced the Q$\times$f$_{0}$ value. When the mot ratio of PbWO$_4$ and TiO$_2$ was 0.913:7.087, near zero $\tau$$_{f}$(0.2ppm/$^{\circ}C$) was obtaibed with $\varepsilon$$_{r}$=22.3, and Q$\times$f/$_{0}$=21,443GHz. With this composition, various amount of B$_2$O$_3$ and CuO were added in order to improve the quality factor. The addition, of B$_2$O$_3$ decreased the $\varepsilon$$_{r}$. However, increased Q$\times$f$_{0}$ and $\tau$$_{f}$. When 2.5 wt% of B$_2$O$_3$ was added to the 0.913PbWO$_4$-0.087TiO$_2$ ceramic, $\tau$$_{f}$ =8.2, $\varepsilon$$_{r}$=20.3, Q$\times$f$_{0}$=54784 GHz. When CuO added to the 0.913PbWO$_4$-0.087TiO$_2$ ceramic, $\tau$$_{f}$ was continuously decreased. And $\varepsilon$$_{r}$ . and Q$\times$f$_{0}$ were increased up to 1.0 wt% then decreased. At 0.1 wt% of CuO addition, the 0.913PbWO$_4$-7.087Ti0$_2$ Ceramic Showed $\varepsilon$$_{r}$=23.5, $\tau$$_{f}$=4.4ppm/$^{\circ}C$, and Q$\times$f$_{0}$=32,932 GHz.> 0/=32,932 GHz.X>=32,932 GHz.> 0/=32,932 GHz.

  • PDF