• Title/Summary/Keyword: quality assurance system

Search Result 643, Processing Time 0.027 seconds

A Study on the Property of NEPE System Propellant with Respect to the Size of RDX (RDX 입도에 따른 NEPE계 추진제 특성 연구)

  • Jang, Myungwook;Kim, Taekyu;Han, Haeji;Yun, Jaeho;Son, Hyunil
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.3
    • /
    • pp.40-45
    • /
    • 2018
  • The propellant tile and crack which account for the greatest proportion of solid rockets are profoundly affected by viscosity and mechanical properties of solid propellant. In this paper solid propellant with nitrate ester polyester(NEPE) system has been researched for the viscosity, mechanical properties and burning properties with size and mixing ratio of RDX. the viscosity of propellant was changed significantly depending on the size of RDX and mixing ratio, and mechanical properties of NEPE system propellant were also varied. Considering both lower viscosity and stable mechanical properties, the optimum size and mixing ratio of RDX can be identified as the main factors to the NEPE system propellant.

Designing a Modular Safety Certification System for Convergence Products - Focusing on Autonomous Driving Cars - (융복합제품을 위한 모듈방식의 안전인증체계 설계 -자율주행 자동차를 중심으로-)

  • Shin, Wan-Seon;Kim, Ji-Won
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.4
    • /
    • pp.1001-1014
    • /
    • 2018
  • Purpose: Autonomous driving cars, which are often represent the new convergence product, have been researched since the early years of 1900 but their safety assurance policies are yet to be implemented for real world practices. The primary purpose of this paper is to propose a modular concept based on which a safety assurance system can be designed and implemented for operating autonomous driving cars. Methods: We combine a set of key attributes of CE mark (European Assurance standard), E-Mark (Automobile safety assurance system), and A-SPICE (Automobile software assurance standard) into a modular approach. Results: Autonomous vehicles are emphasizing software safety, but there is no integrated safety certification standard for products and software. As such, there is complexity in the product and software safety certification process during the development phase. Using the concept of module, we were able to come up with an integrated safety certification system of product and software for practical uses in the future. Conclusion: Through the modular concept, both international and domestic standards policy stakeholders are expected to consider a new structure that can help the autonomous driving industries expedite their commercialization for the technology advanced market in the era of Industry 4.0.

A novel method for determining dose distribution on panoramic reconstruction computed tomography images from radiotherapy computed tomography

  • Hiroyuki Okamoto;Madoka Sakuramachi;Wakako Yatsuoka;Takao Ueno;Kouji Katsura;Naoya Murakami;Satoshi Nakamura;Kotaro Iijima;Takahito Chiba;Hiroki Nakayama;Yasunori Shuto;Yuki Takano;Yuta Kobayashi;Hironori Kishida;Yuka Urago;Masato Nishitani;Shuka Nishina;Koushin Arai;Hiroshi Igaki
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.129-137
    • /
    • 2024
  • Purpose: Patients with head and neck cancer (HNC) who undergo dental procedures during radiotherapy (RT) face an increased risk of developing osteoradionecrosis (ORN). Accordingly, new tools must be developed to extract critical information regarding the dose delivered to the teeth and mandible. This article proposes a novel approach for visualizing 3-dimensional planned dose distributions on panoramic reconstruction computed tomography (pCT) images. Materials and Methods: Four patients with HNC who underwent volumetric modulated arc therapy were included. One patient experienced ORN and required the extraction of teeth after RT. In the study approach, the dental arch curve (DAC) was defined using an open-source platform. Subsequently, pCT images and dose distributions were generated based on the new coordinate system. All teeth and mandibles were delineated on both the original CT and pCT images. To evaluate the consistency of dose metrics, the Mann-Whitney U test and Student t-test were employed. Results: A total of 61 teeth and 4 mandibles were evaluated. The correlation coefficient between the 2 methods was 0.999, and no statistically significant difference was observed (P>0.05). This method facilitated a straightforward and intuitive understanding of the delivered dose. In 1 patient, ORN corresponded to the region of the root and the gum receiving a high dosage (approximately 70 Gy). Conclusion: The proposed method particularly benefits dentists involved in the management of patients with HNC. It enables the visualization of a 3-dimensional dose distribution in the teeth and mandible on pCT, enhancing the understanding of the dose delivered during RT.

Development of Novalis Quality Assurance Protocol for Radiosurgery (방사선수술을 위한 노발리스 품질관리 프로토콜 개발)

  • Lee, Dong-Joon;Lee, Kyung-Nam;Lee, Suk;Lee, Sang-Hoon;Kim, Dae-Hong
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.99-112
    • /
    • 2010
  • In Republic of Korea, there are many Quality Assurance protocol for general radiation treatment machine such as linac. However, Quality Assurance protocol for radiosurgery treatment system is not ready perfectly. One of the radiation treatment machine for radiosurgery, novalis system needs to suitable Quality Assurance protocol for using it right way during radiation treatment and maintaining suitable accuracy for daily, weekly, monthly and annually periods. Therefore, in this article, we develop Quality Assurance protocol for novalis system. We collected and analysed domestic and foreign novalis Quality Assurance protocol. After that, we selected essential QA items and each tolerance range for developing proper QA protocol, and we made anatomical phantom for execution of selected QA items and evaluation of overall state of QA, and then, we use this measured value as a reference. Quality Assurance items are consisted of Mechanical accuracy QA part and Radiation delivery QA part. Mechanical accuracy QA part is comprised of radiation generation machine part, assistive devices part and multi-leaf collimator part. Radiation delivery QA part is divided into radiation isocenter accuracy and dosimetric evaluation. After that, developed novalis QA tables are made by using these QA items. These novalis QA tables would be used to good standard in order to maintain apt accuracy for radiosurgery in daily, weekly, monthly and annually periods.

Quality assurance algorithm using fuzzy reasoning for resistance spot weldings (퍼지추론을 이용한 저항 점용접부위의 품질평가 알고리듬)

  • Kim, Joo-Seok;Lee, Jae-Ik;Lee, Sang-ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.3
    • /
    • pp.644-653
    • /
    • 1998
  • In resistance spot weld, the assurance of weld quality has been a long-standing problem. Since the weld nuggets if resustance spot welding form between the workpieces, visual detection of defects in usually impossible. Welding quality of resistance spot welding can be verified by non destructive and destructive inspections such as X-Ray inspection and testing of weld strength. But these tests, in addition to being time-consuming and costly, can entail risks due to sampling basis. The purpose of this study is the development of the monitoring system based on fuzzy inference, aimed at diagonosis of quality in resistance spot welding. The fuzzy inference system consists of fuzzy input variables, fuzzy membership functions and fuzzy rules. For inferring the welding quality(strength), the experimental data of the spot welding were acquired in various welding conditions with the monitoring system designed. Some fuzzy input variables-maximum, slop and difference values of electrode movement signals-were extracted from the experimental data. It was confirmed that the fuzzy inference values of strength have a .${\pm}$5% error in comparison with actual values for the selected welding conditions(9-10.5KA, 10-14 cycle, 250-300 $kg_f$). This monitoring system can be useful in improving the quality assurance and reliability of the resistance spot welding process.

A STUDY ON THE INTRODUCTION OF THE PAY ADJUSTMENT SYSTEM FOR THE VOLUNTARY ASSURANCE OF QUALITY BY THE CONTRACTORS

  • Byung-Ok Noh;Sang-Beom Lee;Jai-Dong Koo
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.521-525
    • /
    • 2011
  • Although the Korean construction industry has risen rapidly, the quality of the buildings is not met with the industry standard compared to the potential of the technology development and the cost of maintenance has been increased. The user's request for quality have been increased, but in the current building construction, the contractors only follow the specifications of design, material and technology, and their main concern is whether they are in right track with the specification or not. Thus, the necessity of developing technology has been ignored and sufficient opportunities for the development have not been provided as well. In the developed countries, in contrast, the quality assurance and the payment regulation system has been utilized for the active response to the changes of users' request. As a result of this, the maintenance cost has been decreased and the development of construction technology has been improved. Therefore the pay adjustment system is needed to create the improvement of the quality of the buildings by the contractors' earnest building construction. In order to introduce the pay adjustment system suitable to the Korean construction industry, this study presented the logical method of adjusting the construction cost and making payment with the pay adjustment index that is created based on the result of the performance test, after making a set of the indicators of the building performance standard and applied them to the targeted building.

  • PDF

The direction of duality Assurance Policy in the management of industries (기업경영에 있어서의 품질보증의 방향)

  • 황의철
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.12 no.20
    • /
    • pp.91-95
    • /
    • 1989
  • The activities of Quality assurance, in the past, were attached too much importance to the functions and performanced of products. Because of these practices, in general. product safeties were usually minimized corenen more disregarded from the central points. Qualify assurance should he accepted as one of a major management policies to satisfied with the users needs.

  • PDF

A Study on the shift to the reliability-based defense quality policy (신뢰성 기반의 국방 품질정책 전환을 위한 방안 연구)

  • Jeong, Younggkwon;Yoo, Hanjoo;Song, Gwangsuk
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.2
    • /
    • pp.193-210
    • /
    • 2018
  • Purpose: The purpose of this study is to escape from the existing defense quality policy focused on government-led quality assurance for mass-produced items and to secure quality reliability of weapon systems through a defense quality policy paradigm shift based on designing a verification systems anchored on reliability through the enhancement of military supply quality control in the development stage, the enhancement of quality responsibility of the manufacturing contractor and other methods. Methods: For the shift to the quality-based defense quality policy, the status and the problems of the status quo are analyzed and the direction of future defense quality policy is suggested based on literature review of the concept of reliability and reliability in the field of defense, on case studies of global corporations and their quality policies, on the background on quality assurance in defense, and on case studies of quality policies in other government organizations, Results: Based on the case studies of quality policies in global corporations and other government agencies, the importance of preventive quality control from the early development stages, quality control based on the reliability of the materials and parts, and shift of the quality policy to a certification system to achieve these objectives were highlighted. Conclusion: To secure reliability of weapon system quality, the quality policy must be shifted to a system focused on reliability-based design and verification and there is a further need to enhance the operational efficiency and capacity of DTaQ based on studies and evaluation of weapon system reliability.

A Designing Method of Network Quality Assurance Test Bed Design under Next-generation Network Environment (NGN(Next Generation Network)의 네트워크 품질 보증을 위한 테스트베드 모델 설계)

  • Chung, Ji Moon
    • Journal of Digital Contents Society
    • /
    • v.13 no.4
    • /
    • pp.625-629
    • /
    • 2012
  • This paper is presented to prepare NGN quality assurance management process under the quality system test methodology. The process should be drawn for NGN quality measurement framework of multimedia traffic. NGN test bed management process model are QoS measurement metrics, measurement interval meter above, and measuring tools, measuring equipment, measurement methods and measurement results from a series of processes for the analysis and methodology. This model, NGN quality assurance activities should be utilized in the future. Quality target level only when themselves constantly measured and managed, does not guarantee the communication quality of service. It is sensitive to the importance of NGN network technology paradigm for research on quality management in the NGN.

Quality Assurance Strategy for AGO Program in Korea (AGD(통합치과전문임상의)교육 프로그램 질 보장 방안)

  • Shin, Je-Won
    • The Journal of the Korean dental association
    • /
    • v.48 no.11
    • /
    • pp.790-796
    • /
    • 2010
  • Currently, KDA adopted new post-graduated program; advanced education general dentistry(AGD) for 3 years preparation. The AGO program provides the resident the opportunity to deliver the highest quality of comprehensive dental care to the broadest range of the population with a knowledge, comfort, and ease in treating the high risk patient. The purpose of this article is to study the assurance systems of AGO programs in USA and Japan and to suggest a piece of advice whether we choose the way of AGO program assurance system in Korea.