• Title/Summary/Keyword: quadrupole MS

Search Result 99, Processing Time 0.023 seconds

Simultaneous Determination of Anthraquinone, Flavonoids, and Phenolic Antidiabetic Compounds from Cassia auriculata Seeds by Validated UHPLC Based MS/MS Method

  • Girme, Aboli;Saste, Ganesh;Chinchansure, Ashish;Joshi, Swati;Kunkulol, Rahul;Hingorani, Lal;Patwardhan, Bhushan
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.82-89
    • /
    • 2020
  • A systematic isolation and characterization study for Cassia auriculata (CA) seeds resulted in identifying antidiabetic compounds 1,3,8-trihydroxyanthraquinone and quercetin, quercetin-3-O-rutinoside, gallic acid, caffeic acid, ferulic acid, and ellagic acid. The ultra-high-performance liquid chromatography based triple quadrupole mass spectrometry methodology was developed and validated for simultaneous identification and confirmation of these compounds from CA seeds. Multiple reaction monitoring (MRM) based quantification method was developed with MRM optimizer software for MS1 and MS2 mass analysis. The method was optimized on precursor ions and product ions with the ion ratio of each compound. The calibration curves of seven bioactive analytes showed excellent linearity (r2 ≥ 0.99). The quantitation results found precise (RSD, < 10 %) with good recoveries (84.58 to 101.42%). The matrix effect and extraction recoveries were found within the range (91.66 to 102.11%) for the CA seeds. This is the first MS/MS-based methodology applied to quantifying seven antidiabetic compounds in CA seeds and its extract for quality control purposes.

Toxicoproteomics in the Study of Aromatic Hydrocarbon Toxicity

  • Cho, Chang-Won;Kim, Chan-Wha
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.3
    • /
    • pp.187-198
    • /
    • 2006
  • The aromatic hydrocarbons (AHs), which include benzene, polycyclic aromatic hydrocarbons, and dioxin, are important chemical and environmental contaminants in industry that usually cause various diseases. Over the years, numerous studies have described and evaluated the adverse health effects induced by AHs. Currently, "Omics" technologies, transcriptomics and proteomics, have been applied in AH toxicity studies. Proteomics has been used to identify molecular mechanisms and biomarkers associated with global chemical toxicity. It could enhance our ability to characterize chemical-induced toxicities and to identify noninvasive biomarkers. The proteomic approach (e.g. 2-dimensional electrophoresis [2-DE]), can be used to observe changes in protein expression during chemical exposure with high sensitivity and specificity. Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) and electrospray ionization-quadrupole (ESI-Q)-TOF MS/MS are recognized as the most important protein identification tools. This review describes proteomic technologies and their application in the proteomic analysis of AH toxicity.

Metabolomics Approach for Classification of Medicinal Plants

  • Lee, Dong-Ho
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.5-5
    • /
    • 2010
  • Selection of specific medicinal sources as well as bioactive compounds is important for the preparation of medicine and related products with good quality. It is necessary to pay close attention for choosing correct medicinal sources, particularly in case of medicinal plants, because of their diversity, which can affect the quality and efficacy of medicine. Discrimination of plants based on morphological or genetic characteristics has been used as a conventional classification method of pharmaceutical sources so far; however, more need demands more general methods for accurate quality assessment of medicinal plants. In this study, ultra performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/Q-TOF MS) technique applied to this metabolic profiling is a powerful tool due to its higher sensitivity, resolution, and speed compared to conventional HPLC technique. The metabolite profiling of several medicinal plants including Panax ginseng was carried out using UPLC/Q-TOF MS and total metabolites were then subsequently applied to various statistical tools to compare the patterns. The developed metabolomics tool with UPLC/Q-TOF MS successfully identified and classified the samples tested according to their origins.

  • PDF

Determination of the Intracellular Concentrations of Metabolites in Escherichia coli Collected during the Exponential and Stationary Growth Phases using Liquid Chromatography-Mass Spectrometry

  • Park, Chang-Hun;Park, Chang-Hun;Lee, Youn-Jin;Lee, Sang-Yup;Oh, Han-Bin;Lee, Jin-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.524-530
    • /
    • 2011
  • In the present study, we demonstrate that SRM LC-MS/MS method developed by Luo et al. (ref. 10) can be successfully applied to the quantitative analysis of intracellular metabolites in E. coli that are collected at the exponential and stationary growth phases. A focus is given on measuring the changes in the concentrations of intracellular metabolites in batch cultures, which were induced during both the dynamically changing exponential and stationary growth phases. The following intracellular metabolites are quantified in the exponential and stationary phases of E. coli growth, using the SRM mode of a triple quadrupole mass spectrometer: glucose-1-phosphate, fructose-1,6-bisphosphate, phosphoenolpyruvate, pyruvate, acetyl-coenzyme A, 6-phosphogluconate, ribulose-5-phosphate, xylulose-5-phosphate, erythrose-4-phosphate. The determined intracellular metabolite concentration profiles are shown to be in a good agreement with the growth profiles of E. coli, which clearly indicates that SRM LC-MS/MS can be successfully used for following the metabolite changes induced at different growth stages.

Mass Spectrometry-Based Analytical Methods of Amatoxins in Biological Fluids to Monitor Amatoxin-Induced Mushroom Poisoning

  • Choi, Jin-Sung;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.95-105
    • /
    • 2022
  • Amatoxin-induced mushroom poisoning starts with nonspecific symptoms of toxicity but hepatic damage may follow, resulting in the rapid development of liver insufficiency and, ultimately, coma and death. Accurate detection of amatoxins, such as α-, β-, and γ-amanitin, within the first few hours after presentation is necessary to improve the therapeutic outcomes of patients. Therefore, analytical methods for the identification and quantification of α-, β-, and γ-amanitin in biological samples are necessary for clinical and forensic toxicology. This study presents a literature review of the analytical techniques available for amatoxin detection in biological matrices, and established an inventory of liquid chromatography (LC) techniques with mass spectrometry (MS), ultraviolet (UV) detection, and electrochemical detection (ECD). LC-MS methods using quadrupole tandem mass spectrometry, time-of-flight mass spectrometry, and orbitrap MS are powerful analytical techniques for the identification and determination of amatoxins in plasma, urine, serum, and tissue samples, with high sensitivity, specificity, and reproducibility compared to LC with UV and ECD, enzyme-linked immunoassay, and capillary electrophoresis methods.

Putative multiple reaction monitoring strategy for the comparative pharmacokinetics of postoral administration Renshen-Yuanzhi compatibility through liquid chromatography-tandem mass spectrometry

  • Sun, Yufei;Feng, Guifang;Zheng, Yan;Liu, Shu;Zhang, Yan;Pi, Zifeng;Song, Fengrui;Liu, Zhiqiang
    • Journal of Ginseng Research
    • /
    • v.44 no.1
    • /
    • pp.105-114
    • /
    • 2020
  • Background: Exploring the pharmacokinetic (PK) changes of various active components of single herbs and their combinations is necessary to elucidate the compatibility mechanism. However, the lack of chemical standards and low concentrations of multiple active ingredients in the biological matrix restrict PK studies. Methods: A putative multiple reaction monitoring strategy based on liquid chromatography coupled with mass spectrometry (LC-MS) was developed to extend the PK scopes of quantification without resorting to the use of chemical standards. First, the compounds studied, including components with available reference standard (ARS) and components lacking reference standard (LRS), were preclassified to several groups according to their chemical structures. Herb decoctions were then subjected to ultrahigh-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry analysis with appropriate collision energy (CE) in MS2 mode. Finally, multiple reaction monitoring transitions transformed from MS2 of ultrahigh-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry were used for ultrahigh-performance liquid chromatography coupled with triple quadrupole mass spectrometry to obtain the mass responses of LRS components. LRS components quantification was further performed by developing an assistive group-dependent semiquantitative method. Results: The developed method was exemplified by the comparative PK process of single herbs Radix Ginseng (RG), Radix Polygala (RP), and their combinations (RG-RP). Significant changes in PK parameters were observed before and after combination. Conclusion: Results indicated that Traditional Chinese Medicine combinations can produce synergistic effects and diminish possible toxic effects, thereby reflecting the advantages of compatibility. The proposed strategy can solve the quantitative problem of LRS and extend the scopes of PK studies.

Analysis of Marker Substances in Samul-tang by HPLC-MS/MS (HPLC-MS/MS에 의한 사물탕의 지표성분 분석)

  • Yu, Young-Beob;Kim, Mi-Jung;Huang, Dae-Sun;Ha, Hye-Kyeong;Ma, Jin-Yeul;Shin, Hyeun-Kyoo
    • The Korea Journal of Herbology
    • /
    • v.22 no.2
    • /
    • pp.97-102
    • /
    • 2007
  • Objectives : This study presents a high performance liquid chromatography - electrospray ionization-mass spectrometer (HPLC-MS/MS) methods for the quantitative and qualitative analysis of various active components in Samul-tang, which is composed of four crude herbs. Methods : HPLC-ESI-MS/MS for the determinations of paeoniflorin and 5-HMF (5-hydroxymethyl 2-furaldehyde) in the Samul-tang, the separation method was performed on an COSMOS1L 5C18-AR-Il (2.0 X 150 mm I.D.) column by gradient elution with 0.1% acetic acid and 5% CH3CN in water (A)-0.1% acetic acid and 5% H20 in CH3CN (B) as the mobile phase at a flow-rate of 300 ${\mu}L/min$ with detection at quadrupole mass spectrometer. The all marker substances were always detected as the base peaks in the positive ion mode. Results : The paeoniflorin of Paeoniae Radix in Samul-tang showed a strong base peak [M+H2O]+ in the positive detection mode to give the following as; paeoniflorin (498.109 [M+H2O]+, 479.8 [M]+, 301 [M-glucose]+, 179.3 [glucose]+). Based on the HPLC retnetion time and MS of standard compounds confirmed the identity of active compounds in Rehmanniae Radix Preparata as follows; 5-HMF (127.0[M+H]+, 109.3 [M-OH]+) in the positive ion mode. Conclusion : According to the above results, HPLC-ESI-MS method permits assignment of tentative structures such as paeoniflorin and 5-HMF in the Samul-tang.

  • PDF

Accurate Analysis of Chromium in Foodstuffs by Using Inductively Coupled Plasma Mass Spectrometry with a Collision-Reaction Interface

  • Lee, Seung Ha;Kim, Ji Ae;Choi, Seung Hyeon;Kim, Young Soon;Choi, Dal Woong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1689-1692
    • /
    • 2013
  • Food is a common source of chromium (Cr) exposure. However, it is difficult to analyze Cr in complex food matrices by using inductively coupled plasma mass spectrometry (ICP-MS) because the major isotope, $^{52}Cr$, is masked by interference generated by the sample matrix and the plasma gas. Among the systems available to minimize interference, the recently developed collision-reaction interface (CRI) has a different structure relative to that of other systems (e.g., collision cell technology, octopole reaction system, and dynamic reaction cell) that were designed as a chamber between the skimmer cone and quadrupole. The CRI system introduces collision or reaction gas directly into the plasma region through a modified hole of skimmer cone. We evaluated the use of an CRI ICP-MS system to minimize polyatomic interference of $^{52}Cr$ and $^{53}Cr$ in various foodstuffs. The $^{52}Cr$ concentrations measured in the standard mode were 2-3 times higher than the certified values. This analytical method based on an ICP-MS system equipped with a CRI of helium gas was effective for Cr analysis in complex food matrices.

Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of ε-Acetamidocaproic Acid in Rat Plasma

  • Kim, Tae Hyun;Choi, Yong Seok;Choi, Young Hee;Kim, Yoon Gyoon
    • Toxicological Research
    • /
    • v.29 no.3
    • /
    • pp.203-209
    • /
    • 2013
  • A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of ${\varepsilon}$-acetamidocaproic acid (AACA), the primary metabolite of zinc acexamate (ZAC), in rat plasma by using normetanephrine as an internal standard. Sample preparation involved protein precipitation using methanol. Separation was achieved on a Gemini-NX $C_{18}$ column ($150mm{\times}2.0mm$, i.d., 3 ${\mu}m$ particle size) using a mixture of 0.1% formic acid-water : acetonitrile (80 : 20, v/v) as the mobile phase at a flow rate of 200 ${\mu}l/min$. Quantification was performed on a triple quadrupole mass spectrometer employing electrospray ionization and operating in multiple reaction monitoring (MRM) and positive ion mode. The total chromatographic run time was 4.0 min, and the calibration curves of AACA were linear over the concentration range of 20~5000 ng/ml in rat plasma. The coefficient of variation and relative error at four QC levels were ranged from 1.0% to 5.8% and from -8.4% to 6.6%, respectively. The present method was successfully applied for estimating the pharmacokinetic parameters of AACA following intravenous or oral administration of ZAC to rats.

A Dilute-and-Shoot LC-MS/MS Method for Screening of 43 Cardiovascular Drugs in Human Urine

  • Pham, Thuy-Vy;Lee, Gunhee;Mai, Xuan-Lan;Le, Thi-Anh-Tuyet;Nguyen, Thi Ngoc Van;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • A simple, specific, and economical LC-MS/MS method was investigated for the screening of 43 prescribed antihypertensive and related drugs in human urine. The urine samples were simply prepared by diluting and mixing with internal standard before directly introduced to the LC-MS/MS system, which is fast, straightforward, and cost-effective. Fractional factorial, Box-Behnken, and I-optimal design were applied to screen and optimize the mass spectrometric and chromatographic factors. The analysis was carried out on a triple quadrupole mass spectrometer system utilizing multiple reaction monitoring with positive and negative electrospray ionization method. Chromatographic separation was performed on a Thermo Scientific Accucore RP-MS column (50 × 3.0 mm ID., 2.6 ㎛) using two separate gradient elution programs established with the same mobile phases. Chromatographic separation was performed within 12 min. The optimal method was validated based on FDA guideline. The results indicated that the assay was specific, reproducible, and sensitive with the limit of detection from 0.1 to 50.0 ㎍/L. The method was linear for all analytes with coefficient of determination ranging from 0.9870 to 0.9981. The intra-assay precision was from 1.44 to 19.87% and the inter-assay precision was between 2.69 and 18.54% with the recovery rate ranges from 84.54 to 119.78% for all drugs measured. All analytes in urine samples were stable for 24 h at 25℃, and for 2 weeks at -60℃. The developed method improves on currently existing methods by including larger number of cardiovascular medications and better sensitivity of 12 analytes.