• 제목/요약/키워드: push test

검색결과 392건 처리시간 0.024초

강섬유 보강 초고성능 콘크리트의 전단 전달 모델 (Shear Transfer Strength Evaluation for Ultra-High Performance Fiber Reinforced Concrete)

  • 이지형;홍성걸
    • 한국공간구조학회논문집
    • /
    • 제15권2호
    • /
    • pp.69-77
    • /
    • 2015
  • Ultra High Performance Fiber Reinforced Concrete (UHPFRC) has a outstanding tensile hardening behaviour after a crack develops, which gives ductility to structures. Existing shear strength model for fiber reinforced concrete is entirely based on crack opening behavior(mode I) which comes from flexural-shear failure, not considering shear-slip behavior(mode II). To find out the mode I and mode II behavior on a crack in UHPFRC simultaneously, maximum shear strength of cracked UHPFRC is investigated from twenty-four push-off test results. The shear stress on a crack is derived as variable of initial crack width and fiber volume ratio. Test results show that shear slippage is proportional to crack opening, which leads to relationship between shear transfer strength and crack width. Based on the test results a hypothesis is proposed for the physical mechanics of shear transfer in UHPFRC by tensile hardening behavior in stead of aggregate interlocking in reinforced concrete. Shear transfer strength based on tensile hardening behavior in UHPFRC is suggested and this suggestion was verified by comparing direct tensile test results and push-off test results.

초고성능 콘크리트에 대한 Perfobond Rib 전단연결재 거동 평가 (Evaluation of Shear Strength of Perfobond Rib in Ultra High Performance Concrete)

  • 강재윤;정우태
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.5015-5020
    • /
    • 2015
  • 기존에 제안된 Perfobond rib connector의 강도평가식은 압축강도가 약 50 MPa 이하의 콘크리트 강도 범위에 대한 Push-out test의 결과로 유도된 것으로서, 압축강도 80 MPa 이상의 초고성능 콘크리트에 대한 전단 연결재 성능 평가를 위하여 Perfobond rib 연결재의 전단강도를 파악하기 위한 Push-out test를 수행하였다. Perfobond rib connector의 제작변수는 관통홀의 지름 및 개수이며, 강섬유가 혼입된 180 MPa의 콘크리와 강섬유를 혼입하지 않은 압축강도 80 MPa의 콘크리트를 적용하여 콘크리트 강도 변화에 대한 전단강도 변화를 검토하였다. 실험결과, 콘크리트 강도와 홀의 개수가 증가함 따라 전단강도가 증가하며, 다웰 효과에 의한 전단강도 증가율도 큰 것으로 나타났다. 기존에 다른 연구자들이 제안한 강도식으로 계산된 예측치와 비교한 결과, 실험값은 Oguejiofor & Hosain[2]이 제안한 강도식에 근접한 결과를 보였다.

Experimental studies of headed stud shear connectors in UHPC Steel composite slabs

  • Gao, Xiao-Long;Wang, Jun-Yan;Yan, Jia-Bao
    • Structural Engineering and Mechanics
    • /
    • 제74권5호
    • /
    • pp.657-670
    • /
    • 2020
  • Due to the high compressive and tensile strength of ultra-high performance concrete (UHPC), UHPC used in steel concrete composite structures provided thinner concrete layer compared to ordinary concrete. This leaded to the headed stud shear connectors embedded in UHPC had a low aspect ratio. In order to systematic investigate the effect of headed stud with low aspect ratio on the structural behaviors of steel UHPC composite structure s this paper firstly carried out a test program consisted of twelve push out specimens. The effects of stud height, aspect ratio and reinforcement bars in UHPC on the structural behaviors of headed studs were investigated. The push out test results shows that the increasing of stud height did not obviously influence the structural behaviors of headed studs and the aspect ratio of 2.16 was proved enough to take full advantage of the headed stud strength. Based on the test results, the equation considering the contribution of weld collar was modified to predict the shear strength of headed stud embedded in UHPC. The modified equation could accurately predict the shear strength of headed stud by comparing with the experimental results. On the basis of push out test results, bending tests consisted of three steel UHPC composite slabs were conducted to investigate the effect of shear connection degree on the structural behaviors of composite slabs. The bending test results revealed that the shear connection degree had a significantly influence on the failure modes and ultimate resistance of composite slabs and composite slab with connection degree of 96% in s hear span exhibited a ductile failure accompanied by the tensile yield of steel plate and crushing of UHPC. Finally, analytical model based on the failure mode of composite slabs was proposed to predict the ultimate resistance of steel UHPC composite slabs with different shear connection degrees at the interface.

푸쉬업 플러스 운동과 키네시오 테이핑 적용이 견관절 근막동통증후군의 통증과 기능에 미치는 효과 (The Effect of Push-up Plus Excercise with Kinesio-Taping on the Pain and Function in Myofascial Pain Syndrome of Shoulder)

  • 송현승;김은비;김태원;김진영;유성훈;김윤환
    • 대한정형도수물리치료학회지
    • /
    • 제18권1호
    • /
    • pp.31-37
    • /
    • 2012
  • Background: The purpose of this study was conducted to investigate the effects of Push-up plus exercise with kinesio taping on the pain and shoulder motor function in patient with shoulder myofacial pain syndrome. Methods: The patients with myofacial pain syndrome were randomly divided 2 groups. kinesio taping group (n=20) was taken physical therapy program and kinesio taping. Push-up plus exercise with taping group (n=22) was taken physical therapy and kinesio taping with Push-up plus exercise. The kinesio taping applied on upper trapezius and levator scapulae. The Push-up plus exercise performed in standing position and qudripad position during 10 seconds on 15 time, 3 set per each positions. We mearsured the pain degree using PPT, VAS, MPSSI and shoulder motor function using CSA before and after experiment. The significant test of PPT, VAS, MPSSI, CSA according to applying the kinesio taping and Push-up plus exercise between groups used ANCOVA. Results: In the result following analysis, there was significance on PPT (F=7.378, p=.016), VAS (F=13.071, p=.031), CSA (F=5.302, p=.026) between kinesio taping group and Push-up plus exercise with tapping group. Then, Push-up plus exercise with kinesio taping group has significance on the PPT, VAS, CSA in patients with myofacial pain syndrome. Conclusions: It may suggest that kinesio taping combined with Push-up plus exercise will be helpful of the pain and shoulder function improvement in the patients with myofacial pain syndrome.

  • PDF

다양한 접착 시스템 및 포스트의 표면 처리가 섬유 강화 포스트의 접착 강도에 미치는 영향 (Effect of different adhesive systems and post surface treatments on the push-out bond strengths of fiber-reinforced post)

  • 김민우;안진희;김이경;심혜원
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.218-225
    • /
    • 2016
  • 목적: 본 연구에서는 자가-접착 레진 시멘트의 접착 강도에 포스트의 표면 처리와 접착 시스템이 미치는 영향을 조사하고자 하였다. 재료 및 방법: 비슷한 치근 길이를 가진 48개의 사람 상악 단근치를 사용하여 160개의 시편을 제작하고 접착 시스템에 따라 4개의 군으로 분류하였다(no adhesive, Adper Single Bond 2, Clearfil SE Bond, Clearfil S3). 각 군은 포스트 표면 처리 방식에 따라 다시 4개의 군으로 세분하였다(no treatment, sandblast, silane, sandblast and silane). 포스트를(Parapost Fiber White) Rely X Unicem을 사용하여 접착하였다. 치아를 장축에 수직으로 1 mm 두께로 절단 하였다. Push-out test를 0.5 mm/분의 crosshead speed로 시행하였다. 2-way ANOVA, 1-way ANOVA 검정을 시행하였고 Tukey test를 통한 사후 검정을 시행하였다(${\alpha}=0.05$). 결과: Tukey test를 통한 사후 검정에서 접착 시스템에 따른 차이가 나타났다. Clearfil SE Bond가 가장 높은 접착 강도를 나타내었다. 결론: 상아질에 Clearfil SE bond를 사용하고 포스트를 실란 처리시 가장 높은 접착 강도를 나타내었다.

Application of single-well push-drift-pull tests using dual tracers (SF6 and salt) for designing CO2 leakage monitoring network at the environmental impact test site in Korea

  • Kim, Hong-Hyun;Lee, Seong-Sun;Ha, Seung-Wook;Lee, Kang-Kun
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.1041-1052
    • /
    • 2018
  • A single-well push-drift-pull tracer test using two different tracers ($SF_6$ and salt) was performed at the Environmental Impact Test (EIT) site to determine suitable locations for monitoring wells and arrange them prior to artificial $CO_2$ injection and leak tests. Local-scale estimates of hydraulic properties (linear groundwater velocity and effective porosity) were obtained at the study site by the tracer test with two tracers. The mass recovery percentage of the volatile tracer ($SF_6$) was lower than that of the non-volatile tracer (salt) and increased drift time may make degassing of $SF_6$ intensified. The $CO_2$ leakage monitoring results for both unsaturated and saturated zones suggest that the $CO_2$ monitoring points should be located near points at which a high concentration gradient is expected. Based on the estimated hydraulic properties and tracer mass recovery rates, an optimal $CO_2$ monitoring network including boreholes for monitoring the unsaturated zone was constructed at the study site.

Investigation of pipe shear connectors using push out test

  • Nasrollahi, Saeed;Maleki, Shervin;Shariati, Mahdi;Marto, Aminaton;Khorami, Majid
    • Steel and Composite Structures
    • /
    • 제27권5호
    • /
    • pp.537-543
    • /
    • 2018
  • Mechanical shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface in composite beams. Steel pipe as a new shear connector is proposed in this research and its performance to achieve composite strength is investigated. Experimental monotonic push-out tests were carried out for this connector. Then, a nonlinear finite element model of the push-out specimens is developed and verified against test results. Further, the finite element model is used to investigate the effects of pipe thickness, length and diameter on the shear strength of the connectors. The ultimate strengths of these connectors are reported and their respective failure modes are discussed. This paper comprises of the push-out tests of ten specimens on this shear connector in both the vertical and horizontal positions in different reinforced concretes. The results of experimental tests are given as load-deformation plots. It is concluded that the use of these connectors is very effective and economical in the medium shear demand range of 150-350 KN. The dominant failure modes observed were either failure of concrete block (crushing and splitting) or shear failure of pipe connector. It is shown that the horizontal pipe is not as effective as vertical pipe shear connector and is not recommended for practical use. It is shown that pipe connectors are more effective in transferring shear forces than channel and stud connectors. Moreover, based on the parametric study, a formula is presented to predict the pipe shear connectors' capacity.

다양한 지지면에서 푸쉬업 플러스 운동이 20대 건강한 성인의 어깨 안정화 근육 두께에 미치는 영향 (Effect of push-up plus exercise on shoulder stabilization muscle thickness in healthy adults in their twenties on various support surfaces)

  • 정진규;박재철
    • 대한물리치료과학회지
    • /
    • 제29권3호
    • /
    • pp.48-55
    • /
    • 2022
  • Background: The purpose of this study is to examine the effect of push-up plus exercise on the changes in the thickness of the trapezius trapezius, serratus anterior and pectoralis major muscles involved in shoulder stability in various support surfaces. Design: Randomized controlled trial. Methods: The thickness change of the shoulder stabilizing muscle was measured using an ultrasound device. Corresponding t-test was performed to confirm the change within the group before the experiment and after 5 weeks. And one-way ANOVA was used to confirm the change between groups after 5 weeks. As a post hoc test, the least significant difference test was performed, and the significance level was set to a=0.05. Results: Changes in the thickness of the trapezius muscle within the group were significantly different between UPEG and SPEG after 5 weeks (p<0.05), and there was a significant difference between groups after 5 weeks (p<0.05). Changes in the thickness of the serratus anterior and pectoralis major muscle within the group were significantly different after 5 weeks in PEG, UPEG and SPEG (p<0.05), and the changes between the groups were significantly different in the serratus anterior muscle after 5 weeks (p<0.05). Conclusion: From the results of this study, it was found that the push-up exercise on an unstable support surface was effective for strengthening the trapezius upper and serratus anterior. This study intends to suggest the possibility of application as basic data for a push-up plus exercise program in clinical practice.

Push-Pull Type 철도차량 Jerking 현상 해석 (Dynamic Analysis of Jerking in Push-Pull Type Train)

  • 김영준;박상규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.502-509
    • /
    • 1998
  • The scheme to reduce jerking phenomena in one push-pull type trainset was proposed. To simulate the jerking between coaches, dynamic analysis model was made. This model could analyze longitudinal dynamic behavior between locomotives and coaches caused by spring and damping characteristics of couplers and center pivots; characteristic curves of traction and braking. To validate the analysis results, tests were conducted in the same driving and braking condition. Comparison of longitudinal acceleration between simulation and test results shows a good agreement. To minimize the jerking phenomena, lots of dynamic simulations were conducted with varying driving/braking effort curve. From the results of simulations, an efficient and economic way to reduce jerking phenomena was found to be to reduce slope of tractive effort curve and synchronize braking time between locomotives and coaches. Test results show that this way could reduce the jerking Phenomena. To express jerkins Phenomena quantitatively, maximum peak to peak values of acceleration were used.

  • PDF

Study on push-out test and bond stress-slip relationship of circular concrete filled steel tube

  • Yin, Xiaowei;Lu, Xilin
    • Steel and Composite Structures
    • /
    • 제10권4호
    • /
    • pp.317-329
    • /
    • 2010
  • According to the results of 9 circular concrete filled steel tube (CFT) push-out tests, a new theoretical model for average bond stress versus free end slip curve is proposed. The relationship between verage bond stress and free end slip is obtained considering some varying influential parameters such as slenderness ratio and diameter-to-thickness ratio. Based on measured steel tube strain and relative slip at different longitudinal positions, the distribution of bond stress and relative slip along the length of steel tube is obtained. An equation for predicting the varying bond-slip relationship along longitudinal length and a position function reflecting the variation are proposed. The presented method can be used in the application of finite element method to analyze the behavior of CFT structures.