• Title/Summary/Keyword: push test

Search Result 392, Processing Time 0.025 seconds

Effective Utilization of DLNA Functions in Home Media Devices (홈 미디어 기기의 DLNA 소프트웨어 효율적 적용)

  • Kang, Ki-Cheol;Kim, Se-Young;Kim, Dae-Jin
    • Journal of Broadcast Engineering
    • /
    • v.17 no.1
    • /
    • pp.37-48
    • /
    • 2012
  • These days many DLNA home media network services start in home network area. DLNA networking softwares included in DLNA media devices contains all of server, renderer and controller functions. But a home media device in home media network environment not uses all of DLNA functions but uses only limited functions. Using all of integrated DLNA functions wastes networking and processing resources especially in home media network, because a home media device uses very limited functions. For example, a smart-TV has a main role of playback and a network attached storage has a main role of media content storage. In this paper, we analyze integrated DLNA networking softwares and design DLNA software models representing each home media device so as to utilize device resources efficiently. And we implement DLNA softwares for smart-TV and smart-phone and test resource efficiency.

Evaluation of Osseointegration around Tibial Implants in Rats by Ibandronate-Treated Nanotubular Ti-32Nb-5Zr Alloy

  • Nepal, Manoj;Li, Liang;Bae, Tae Sung;Kim, Byung Il;Soh, Yunjo
    • Biomolecules & Therapeutics
    • /
    • v.22 no.6
    • /
    • pp.563-569
    • /
    • 2014
  • Materials with differing surfaces have been developed for clinical implant therapy in dentistry and orthopedics. This study was designed to evaluate bone response to titanium alloy containing Ti-32Nb-5Zr with nanostructure, anodic oxidation, heat treatment, and ibandronate coating. Rats were randomly assigned to two groups for implantation of titanium alloy (untreated) as the control group and titanium alloy group coated with ibandronate as the experimental group. Then, the implants were inserted in both tibiae of the rats for four weeks. After implantation, bone implant interface, trabecular microstructure, mechanical fixation was evaluated by histology, micro-computed tomography (${\mu}CT$) and the push-out test, respectively. We found that the anodized, heat-treated and ibandronate-coated titanium alloy triggered pronounced bone implant integration and early bone formation. Ibandronate-coated implants showed elevated values for removal torque and a higher level of BV/TV, trabecular thickness and separation upon analysis with ${\mu}CT$ and mechanical testing. Similarly, higher bone contact and a larger percentage bone area were observed via histology compared to untreated alloy. Furthermore, well coating of ibandronate with alloy was observed by vitro releasing experiment. Our study provided evidences that the coating of bisphosphonate onto the anodized and heat-treated nanostructure of titanium alloy had a positive effect on implant fixation.

A Study on Correlation among Physical Fitness, Diet Intakes and Serum Lipid in Middle Aged Women. (중년여성의 체력, 식이섭취와 혈청지질과의 상관관계에 대한 연구)

  • 안창순
    • The Korean Journal of Food And Nutrition
    • /
    • v.6 no.4
    • /
    • pp.255-267
    • /
    • 1993
  • This study was performed to investigate the correlations among physical anthropometric measurement, diet intakes, physical fitness test, and serum lipids in eight sedentary women(control group), and twenty seven exercising women(aerobic groups), aged 35~45 years. The results of the study are as follows : 1) systolic blood pressure(SBP) and diastolic blood pressure(DBP) of aerobic groups were lower than serf entary. Pulse rate was decreased according to the length of aerobic periods. Muscular endurance and jump power of all subjects were stronger than standard range, and those of aerobic exercising groups were stronger than control group. Muscular power of the upper half of the body In all subjects were lower than standard range. 2) Daily calorie intakes of all subjects were in the ring: of recommended dietary allowances (RDA) for Koreans. But daily protein Intakes were higher than RDA. daily cholestrol intakes of all subjects were slightly less than 200~300 mg: which is normal consumption of Koreans. 3) There was a significant positive correlation between serum 7G and daily protein intakes. It was considered that excessive protein intake converted to serum 7G. There was not a significant correlation between serum TC and dietary TC. Therefore, dietary TC seemed to have not much effect on serum TC. Physical fitness was negatively related to serum TG, TC, LDL-C, but positively related to HDL-C, HDL-C /TC. It was found that the serum lipids could be changed better according to improving the physical fitness. There were significant positive correlations between SBP and serum TC, LDL-C. (According to this results), the higher SBP, the higher serum TC, LDL-C tended to be. There was a significant positive correlations between sit up and weightloss nth exercise r=0.7(p<0.001), push ups and weightless with exercise r=0.5(p<0.001). It was considered that muscle strength could be improved according to the weightloss. 4) The purpose of exercise in aerobic groups was rather promoting health than reducing body fatness. Most of al1 subjects (83.2%) drank caffeine-contained beverage therefore, we should concern about that absorption of Fe could be Interrupted and blood pressure could be elevated by caffeine.

  • PDF

Laboratory Experiments for the Force and Load with Pseudo-Dynamic Test: Ex-vivo Study for the Manual Therapy

  • Choi, Wansuk;Choi, Taeseok;Heo, Seoyoon;Lee, Wooram
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.4
    • /
    • pp.1889-1896
    • /
    • 2019
  • Background: Because of the lack of accurate values for applied forces in manual therapy, manual therapists relies on the magnitude of the individual's perception during applying the force. However, excessive loading maneuvers carry risks for patients. Objective: To establish the relationship between the maximal force applied to swine skin with the specific region, sex, and baseline parameters of the subject. Design: Ex-vivo Study and laboratory Experimental research Methods: 3.5 kg of Korean pork sirloin that is a piece of swine was handled and it was set 3 dimensions; #A; #B; #C. Forty-seven participants who has no experience in physical therapy randomly carried out the experiment, indicated to push each place of the pressure spots with same posture and process under supervision from the instructor who has over 15 years of manual therapy, and we measured the pressure force in each time. Results: The biggest pressure force was recorded in spot #A, and #B was represented after #C. Pressure on #A showed certain statistic relation with height (r=.317, p<.05) and weight (r=.434, p<.01); pressure on #B showed certain relation which has statistical meaning with only height (r=.401, p<.01); pressure on #C emerged to have statistic relationship with height (r=.308, p<.05)and weight (r=.428, p<.01). The age aspect revealed relation with pressure on #A, #B and #C, but that was not statistically significant. Conclusions: It can be inferred that there is the most loss of pressure in the area where cartilage is like an island in the middle.

The Effects of Various Directions of Handle Grip on the Upper Limb Muscle Activity of Wheelchair Attendants during Ramp Climbing

  • Ahn, Su-Hong;Lee, Su-Kyoung
    • PNF and Movement
    • /
    • v.16 no.3
    • /
    • pp.415-424
    • /
    • 2018
  • Purpose: This study aimed to determine the effects of various wheelchair handling directions on the upper limb muscle activities of wheelchair attendants while climbing a ramp. Methods: For the study participants, healthy males over 20 years of age were chosen, and the order of the direction of wheelchair handle grip was determined using a randomized method. The handling directions for pushing the wheelchair up a ramp included a general grip with ulnar deviation, a medial grip with wrist pronation, and a neutral grip with a neutral wrist. The muscle activities in the participants' upper limbs were measured using surface electromyography. For statistical data processing, SPSS 18.0 was used to perform repeated measures ANOVA in order to compare the muscle activity among the intervention groups. A contrast test was also conducted among the participants. The significance level (${\alpha}$) was set to 0.05. Results: There was a significant difference between groups using a general grip and a medial grip in the biceps brachii, triceps brachii, and flexor carpi radialis muscles (p<0.05). There was also a significant difference between using a general grip and a neutral grip in the biceps brachii and flexor carpi radialis muscles (p<0.05), and there was a significant difference between using a medial grip and a neutral grip in the biceps brachii and extensor carpi radialis brevis muscles (p<0.05). Conclusion: In this study, the wheelchair assistants' wrist muscle activity was the lowest with a neutral grip while ascending a ramp. Accordingly, this study proposes that wheelchair assistants push wheelchairs up ramps with a neutral grip.

Experimental and numerical study on shear studs connecting steel girder and precast concrete deck

  • Xia, Ye;Chen, Limu;Ma, Haiying;Su, Dan
    • Structural Engineering and Mechanics
    • /
    • v.71 no.4
    • /
    • pp.433-444
    • /
    • 2019
  • Shear studs are often used to connect steel girders and concrete deck to form a composite bridge system. The application of precast concrete deck to steel-concrete composite bridges can improve the strength of decks and reduce the shrinkage and creep effect on the long-term behavior of structures. How to ensure the connection between steel girders and concrete deck directly influences the composite behavior between steel girder and precast concrete deck as well as the behavior of the structure system. Compared with traditional multi-I girder systems, a twin-I girder composite bridge system is more simplified but may lead to additional requirements on the shear studs connecting steel girders and decks due to the larger girder spacing. Up to date, only very limited quantity of researches has been conducted regarding the behavior of shear studs on twin-I girder bridge systems. One convenient way for steel composite bridge system is to cast concrete deck in place with shear studs uniformly-distributed along the span direction. For steel composite bridge system using precast concrete deck, voids are included in the precast concrete deck segments, and they are casted with cast-in-place concrete after the concrete segments are erected. In this paper, several sets of push-out tests are conducted, which are used to investigate the heavier of shear studs within the voids in the precast concrete deck. The test data are analyzed and compared with those from finite element models. A simplified shear stud model is proposed using a beam element instead of solid elements. It is used in the finite element model analyses of the twin-I girder composite bridge system to relieve the computational efforts of the shear studs. Additionally, a parametric study is developed to find the effects of void size, void spacing, and shear stud diameter and spacing. Finally, the recommendations are given for the design of precast deck using void for twin I-girder bridge systems.

Bond-slip behaviour of H-shaped steel embedded in UHPFRC

  • Huang, Zhenyu;Huang, Xinxiong;Li, Weiwen;Chen, Chufa;Li, Yongjie;Lin, Zhiwei;Liao, Wen-I
    • Steel and Composite Structures
    • /
    • v.38 no.5
    • /
    • pp.563-582
    • /
    • 2021
  • The present study experimentally and analytically investigated the push-out behaviour of H-shaped steel section embedded in ultrahigh-performance fibre-reinforced concrete (UHPFRC). The effect of significant parameters such as the concrete types, fibre content, embedded steel length, transverse reinforcement ratio and concrete cover on the bond stress, development of bond stress along the embedded length and failure mechanism has been reported. The test results show that the bond slip behaviour of steel-UHPFRC is different from the bond slip behaviour of steel-normal concrete and steel-high strength concrete. The bond-slip curves of steel-normal concrete and steel-high strength concrete exhibit brittle behaviour, and the bond strength decreases rapidly after reaching the peak load, with a residual bond strength of approximately one-half of the peak bond strength. The bond-slip curves of steel-UHPFRC show an obvious ductility, which exhibits a unique displacement pseudoplastic effect. The residual bond strength can still reach from 80% to 90% of the peak bond strength. Compared to steel-normal concrete, the transverse confinement of stirrups has a limited effect on the bond strength in the steel-UHPFRC substrate, but a higher stirrup ratio can improve cracking resistance. The experimental campaign quantifies the local bond stress development and finds that the strain distribution in steel follows an exponential rule along the steel embedded length. Based on the theory of mean bond and local bond stress, the present study proposes empirical approaches to predict the ultimate and residual bond resistance with satisfactory precision. The research findings serve to explain the interface bond mechanism between UHPFRC and steel, which is significant for the design of steel-UHPFRC composite structures and verify the feasibility of eliminating longitudinal rebars and stirrups by using UHPFRC in composite columns.

The Effects of Neck Traction and Foot Type on Plantar Pressure Distribution during Walking (경추 견인기 부착 여부에 따른 발 형태별 보행 시 족저압에 미치는 영향)

  • Hong, Miran;Yi, Kyoungock
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.4
    • /
    • pp.321-335
    • /
    • 2020
  • Objective: The purpose of this study was to investigate the effect of neck traction and foot type on plantar pressure distribution during walking. Method: Total of 24 data were collected from women working with a computer for more than 6 hours every day. Three groups by foot type were divided: Pes Planus, normal foot, and Pes Cavus. Depending on the foot type and cervical traction, plantar pressure variables were measured; CA, MF, PP, and CT. Each variable was divided into 12 masks. MANOVA was performed for the difference of plantar pressure variables by foot type, and a paired t-test was performed for the cervical traction within groups. Results: The total CA decreased in the Pes Planus (p<.001) and Pes Cavus (p<.05) groups. MF increased in the big toe (p<.01) and 2nd toe (p<.05) of the normal foot, and MF-3rd metatarsal decreased (p<.01). The MF-2nd toe (p<.01) and 3rd toe (p<.05) of Pes Cavus decreased. The PP decreased in 2nd toe (p<.05), 3rd toe (p<.01), and 4th toe (p<.05) of the Pes Cavus. In normal foot, the PP-3rd metatarsal (p<.05) and PP-4th metatarsal (p<.01) reduced. In Pes Planus, PP decreased in the hindfoot (p<.05). In Pes Cavus group wearing a neck-tractor, the CT-hindfoot increased (p<.05). Conclusion: There was a significant change in the plantar pressure change by foot type after neck traction. When walking with a neck-tractor, the heel impact was alleviated in the Pes Planus, and the Pes Cavus showed the smooth and effective propulsion in the push-off. Overall, weight acceptance was effectively performed when walking with neck-traction. It was also found that the neck-tractor corrects the alignment of the neck, thereby creating a more stable gait pattern.

Effect of irrigation protocols on smear layer removal, bond strength and nanoleakage of fiber posts using a self-adhesive resin cement

  • Rodrigo Stadler Alessi;Renata Terumi Jitumori ;Bruna Fortes Bittencourt;Giovana Mongruel Gomes ;Joao Carlos Gomes
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.3
    • /
    • pp.28.1-28.13
    • /
    • 2023
  • Objectives: This study aimed to investigate the effect of the application method of 2% chlorhexidine (CHX) and its influence on the adhesion of fiberglass posts cemented with a self-adhesive resin cement. Materials and Methods: Sixty human mandibular premolars were endodontically treated and divided into 5 groups (n = 12), according to the canal irrigant and its application method: 2 groups with conventional syringe irrigation (CSI)-2.5% sodium hypochlorite (NaOCl) (control) and 2% CHX- and 3 groups with 2% CHX irrigation/activation-by passive ultrasonic irrigation (PUI), Easy Clean file, and XP-Endo Finisher file. Two roots per group were evaluated for smear layer (SL) removal by scanning electron microscopy. For other roots, fiber posts were luted using a self-adhesive resin cement. The roots were sectioned into 6 slices for push-out bond strength (BS) (7/group) and nanoleakage (NL) (3/group). Data from SL removal were submitted to Kruskal-Wallis and Student-Newman-Keuls tests (α = 0.05). Data from BS and NL were evaluated by 2-way analysis of variance and Tukey's test (α = 0.05). Results: For SL removal and BS, the CHX irrigation/activation promoted better values than CSI with CHX (p < 0.05), but it was not significantly different from CSI with NaOCl (p > 0.05). For NL, the lowest values were obtained by the chlorhexidine irrigation/activation groups (p < 0.05). Conclusions: Active 2% CHX irrigation can be used to improve the post space cleaning and adhesion before fiber post cementation with self-adhesive resin cements.

Preflight Calibration Results of Wide-Angle Polarimetric Camera (PolCam) onboard Korean Lunar Orbiter, Danuri

  • Minsup Jeong;Young-Jun Choi;Kyung-In Kang;Bongkon Moon;Bonju Gu;Sungsoo S. Kim;Chae Kyung Sim;Dukhang Lee;Yuriy G. Shkuratov;Gorden Videen;Vadym Kaydash
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.293-299
    • /
    • 2023
  • The Wide-Angle Polarimetric Camera (PolCam) is installed on the Korea's lunar orbiter, Danuri, which launched on August 5, 2022. The mission objectives of PolCam are to construct photometric maps at a wavelength of 336 nm and polarization maps at 461 and 748 nm, with a phase angle range of 0°-135° and a spatial resolution of less than 100 m. PolCam is an imager using the push-broom method and has two cameras, Cam 1 and Cam 2, with a viewing angle of 45° to the right and left of the spacecraft's direction of orbit. We conducted performance tests in a laboratory setting before installing PolCam's flight model on the spacecraft. We analyzed the CCD's dark current, flat-field frame, spot size, and light flux. The dark current was obtained during thermal / vacuum test with various temperatures and the flat-field frame data was also obtained with an integrating sphere and tungsten light bulb. We describe the calibration method and results in this study.