• 제목/요약/키워드: purification plants

검색결과 254건 처리시간 0.023초

도시녹지의 대기환경개선 효과 - 서울시 중구를 중심으로 - (Effects of Urban Greenspace on Improving Atmospheric Environment - Focusing on Jung-gu in Seoul -)

  • 조현길;조용현;안태원
    • 한국조경학회지
    • /
    • 제31권3호
    • /
    • pp.83-90
    • /
    • 2003
  • This study explored effects of urban greenspace on improving atmospheric environment, which is concerned with $CO_2$, SO$_2$ and NO$_2$ uptake, and with reduction of summer air temperatures. The site of this study was focused on Jung-gu in Seoul. Tree density and cover were 1.1 trees/100 $m^2$ and 12.5% respectively for the study area except forest lands. Atmospheric purification by greenspace was associated with changes in tree cover per unit area of each land use type. The mean $CO_2$ storage by woody plants was 19.4t/ha, and annual uptake averaged 2.2t/ha/yr for $CO_2$, 1.9kg/ha/yr for SO$_2$ and 5.0kg/ha/yr for NO$_2$. Entire tree plantings in the study area played a significant role by annually offsetting $CO_2$ emissions of about 1,830t from fossil fuel consumption by 330 persons, SO$_2$ emissions of 1,620kg by 1,080 persons, and NO$_2$ emissions of 4,230kg by 450 persons. The summer air temperature was 3.6$^{\circ}C$ cooler at a location with 54% cover of woody plants and 4.5$^{\circ}C$ cooler at a forest site with 100% cover, compared to a place with no planting. A 10% increase of woody plant cover was estimated to decrease summer air temperature by approximately 0.6$^{\circ}C$ until a certain level of canopy cover. Analyzing data from the Automatic Weather Stations in Seoul revealed that increasing tree cover decreased mean air temperature for the summer season (Jun~Aug) in a nonlinear function. Woody plant cover was the best predictive variable of summer temperature reduction. The results from this study are expected to be useful in emphasizing the environmental benefits and importance of urban greenspace enlargement, and in urging the necessity for planting and management budgets.

A Unique Strategy for Recovering Recombinant Proteins from Molecular Farming: Affinity Couture on Engineered Oilbodies

  • Seon, Jeong-Hoon;J.Steven Szarka;Maurice M. Moloney
    • Journal of Plant Biotechnology
    • /
    • 제4권3호
    • /
    • pp.95-101
    • /
    • 2002
  • Molecular faming has the potential to provide large amounts of recombinant protein for use in diagnostics and as therapeutics. Various strategies have been developed to enhance the expression level, stability, and native folding of recombinant proteins produced in plants. Few investigations into the subcellular distribution of recombinant proteins within plant cells have been published despite the potential to increase the expression level and impact the purification process. This review article discusses the current strategies used for targeting recombinant proteins to various subcellular locations and the advantages of targeting to seed oil bodies for molecular farming applications. Specifically, the affinity capture of antibodies using recombinant oilbodies is discussed.

Characteristics of Tobacco Mosaic Virus Isolated from Wasabi (Eutrema wasabi) in Korea

  • Kim, Hyung-Moo;Lee, Kui-Jae
    • The Plant Pathology Journal
    • /
    • 제15권4호
    • /
    • pp.247-250
    • /
    • 1999
  • Wasabies showing mosaic symptoms were collected and extracted for virus purification. Tobacco mosaic virus (TMV) was identified as causal agent by electron microscopy and nucleic acid and coat protein analyses. TMV strains were determined by enzyme-linked immunosorbent assay (ELISA). TMV was identified as W and C strain in wasabi. The results of host reaction indicated that this virus induced local lesions on Nicotiana tabacum cv. Bright Yellow and N. glutinosa, leaf spots on Chenopodium amaranticolor and mosaic symptoms on wasabi. Rot shape virus particles were observed and was about 300 nm in length. About 6.5 kb single RNA molecule was observed from extracted viral RNA sample and 26 KDa coat protein was detected in denatured acrylamide gel. Infection ratio of TMV was 8% for the first cultivation year, but was 22% for the second year when TMV-W antiserum was used. The results of this experiment showed that infection ratios of both TMV-W and TMV-C strains were higher compared to that of TMV-P strain.

  • PDF

위핑 유동 조건에서의 직사각형 체 주위 유동의 수력학적 분석 (Hydrodynamic Analysis of Rectangular Sieve Tray under Weeping Conditions)

  • 호산나 우위톤즈;이인원
    • 한국가시화정보학회지
    • /
    • 제15권3호
    • /
    • pp.34-40
    • /
    • 2017
  • Within fractionating devices existing in separation and purification industries, sieve trays are widely used as tower internals and their choice is due to economical attractiveness. While operating a trayed distillation tower weeping phenomenon has a critical effect on the efficiency, in this case study a weeping phenomenon was undertaken by means of numerical model in a rectangular sieve tray. Eulerian-Eulerian Computational Fluid Dynamics (CFD) method was used and the obtained CFD results are in a good agreement with the experimental data in terms of weeping rate and pressure drop.

Measurement of characteristics of plasma discharge in liquid

  • Kim, Ju-Sung;Min, Boo-Ki;Kang, Seong-Oun;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.153-153
    • /
    • 2015
  • Application of the plasma is already highlighted as a new technology in the last few years. In these days, there are lots of attempt in various application with plasma in that it is known as an effective treatment to animal, plants, material and so on. Plasma in liquid, one of new plasma applications, has advantages in ability to treat bio-cell or solutions. For example, electro-surgery, water purification, radical generation and so on. Especially, plasma discharge in solutions is very useful technique and difficult to generate due to electrolysis, vaporization and something else. In this study, we have performed plasma discharge and checked sustainability of plasma in solution(saline 0.9%). And we have measured basic characteristics of plasma in liquid. Such as electrical energy and plasma density are calculated from discharging current and voltage. Also, its thermal energy is measured with IR camera.

  • PDF

Carotenoid의 생리활성과 함량분석 (Biological Activities and Analysis of Carotenoids in Plants)

  • 김정봉;하선화;이종렬;김행훈;윤상홍;김용환
    • 한국작물학회지
    • /
    • 제48권
    • /
    • pp.72-78
    • /
    • 2003
  • Carotenoids are the major pigment of pepper (Capsicum annuum) and tomato (Lycopersicon esulentum) which are very important foods in Korea. However the analysis of carotenoids is quite complicated because of their diversity and the presence of cis-trans isomeric forms of these compounds. The objective of this review is to collect the achievements on the field of the chromatographic separation of carotenoids in food and some vegetables, to describe and critically evaluate the techniques, And to compare the benefits and shortcomings of the various chromatographic methods such as adsorption and reversed-phase HPLC and thin-layer chromatography. HPLC equipped with ultra-violet or photodiode array detection is most often employed in routine use for the analysis of carotenoids. Here, the method to analyze carotenoids by HPLC separation after solvent extration and purification from pepper powder samples done in our laboratory is also mentioned.

흡입관이 부착된 이젝터의 속도분포와 압력분포 연구 (A Study on the Velocity Profiles and Pressure Distributions in Ejector Linking Inhale Duct)

  • 이행남;박길문;이덕구;설재림
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.488-494
    • /
    • 2005
  • The ejector is used to obtain a vacuum state, and it has been applied to a lot of industry field such as a heat engine, a fluid instrument power plant. a food industry, an environment industry etc., because there is no problem even it is mixed with any kind of liquid, gas. and solid. The flow characteristics in the ejector was investigated by a PIV and a CFD. The agreement between numerical analysis and experiment shows the validity of this study and the results of this study would be useful to the engineers who design for the flow systems for heating. ventilation. air conditioning and wastewater purification plants.

분지덕트 내의 유동특성 (The Flow Characteristics in Dividing Ducts)

  • 이행남;박길문;이덕구
    • 한국유체기계학회 논문집
    • /
    • 제5권4호
    • /
    • pp.19-25
    • /
    • 2002
  • The flow characteristics in a bifurcated duct are investigated experimentally. Physical properties such as mean velocity vectors, mean vorticity, and total pressure distributions are obtained for three different Reynolds numbers (578, 620, 688) using PIV measurements and CFD analysis. Also, two different dividing ducts ($90^{\circ},\;60^{\circ}$) were selected for study. The results of this study would be useful to the engineers designing flow systems for heating, ventilation, air conditioning and waste-water purification plants.

물관련 설비를 이용한 소수력발전 성능분석 (Performance Analysis for Small Hydro Power at Existing Water Treatment Facilities)

  • 박완순;이철형
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.134-137
    • /
    • 2008
  • A methodology to evaluate the performance analysis for small hydropower at existing water treatment facilities has been studied. It consists of two main parts; flow duration function which can describe existing water treatment facilities and performance analysis to estimate the output characteristics of small hydro power plants. The output performance characteristics for Mi-ho reservoir, Sum-kang low dam, Sun-cheon sewage treatment plant and Nam-dong purification plant were analyzed, using developed model. According to the simulation results, the predicted data show that the data were in good agreement with measured results. Also, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power at existing water treatment facilities.

  • PDF

PIV기법을 이용한 분기 사각덕트네의 유동특성에 관한 실험적 연구 (An Experimental Study on the Flew Characteristics in Dividing Rectangular Duet by using a PIV Technique)

  • 이행남;박길문;이덕구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권6호
    • /
    • pp.1195-1202
    • /
    • 2001
  • The flow characteristics in a bifurcated duct are investigated experimentally. Physical properties such as mean velocity vectors, mean x-y stress distributions, mean vorticity and total pressure distributions are Obtained for three different Reynolds numbers(578, 620, 688) Using PIV measurements and CFD analysis. Also, three different rates of discharge Q=26.11 l/min, Q=28.11 $\ell$/min, Q=31.17 $\ell$/min) were selected foy experimental conditions. The results of this study would be useful to the engineer in designing the flow systems for heating, ventilation, air conditioning and wastewater purification plants.

  • PDF