• 제목/요약/키워드: purification efficiencies

검색결과 68건 처리시간 0.024초

A Study on Water Quality Purification Function by Using Planting Concrete and Porous Concrete (다공성 콘크리트와 식생 콘크리트에 의한 수질정화기능에 관한 연구)

  • Ahn, Tae Woong;Choi, I Song;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • 제17권5호
    • /
    • pp.271-278
    • /
    • 2008
  • The purpose of this research provides the basic solution about waterfront and promotes the inherent capability, that recoveries both the river and gives the river for water quality to improve plan. In this study, we compare and analysis the slope contact between filter media of the porous concrete and planting concrete. As a result, when appling the porous concrete, it can show the removal efficiency is SS 53%, BOD 39%, COD 20%, T-N 36% T-P 42% and appling planting concrete is SS 58%, BOD42%, COD 26%, T-N 45%, T-P 53%. Therefore, planting concrete is higher removal efficiency (SS 5%, BOD 3%, COD 6%, T-N 9%, T-P 10%) than porous concrete. The experimental results show that using purification filter media on planting concrete is better than on porous concrete, because it have the higher purification filter efficiency. The quality of water improves vegetarian concrete, that can expect the increase of the self-purification capacity and improve the spectacle for providing the waterside and planting of planting concrete. In addition, it can complete and apply the research if having enough time for experimentation and accurate study for mechanism by plant, we can use both planting concrete filter media and the existing dike. As a result, we can gain the better quality of the water of the city's rivers and good economic value, that is spread by all cities applicable technologies. So it can be expected using well for future.

Adsorption Properties of Heavy Metal Elements using Zeolite (제올라이트를 이용한 중금속 원소들의 흡착 특성)

  • Shim, Sang-Kwon;Park, Jin-Tai;Kim, Tae-Sam
    • Analytical Science and Technology
    • /
    • 제13권1호
    • /
    • pp.96-100
    • /
    • 2000
  • The adsorption of heavy-elements to zeolite has been investigated at various adsorptional condition for purification of waste water. Four heavy elements, Cd, Cr, Cu and Pb, were examined, because they are concerned to the major heavy-element contamination. The adsorption efficiencies are measured at the different conditions such as adsorption times and pHs. The practical adsorption was achived and reaches to maximum within 30 minute by using of 2-g zeolite for 50 mL of heavy-element solution. The overall adsorption efficiencies for Cr and Cu are high and become better at low pH. Cd and Pb have 95% of adsorption ratio and this is lower than other two elements. Cadmium shows an abnormally low adsorption at low pH.

  • PDF

Characterization of Two Ricin Isoforms by Sodium Dodecyl Sulfate-Capillary Gel Electrophoresis and Capillary Isoelectric Focusing

  • Na, Dong-Hee;Park, Eun-Ji;Kim, Myung-Sun;Cho, Cheong-Kwan;Woo, Byung-Ho;Lee, Hye-Suk;Lee, Kang-Choon
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권12호
    • /
    • pp.4253-4257
    • /
    • 2011
  • Sodium dodecyl sulfate-capillary gel electrophoresis (SDS-CGE) and capillary isoelectric focusing (CIEF) were employed to characterize and compare ricin E purified from the small grain seeds of Ricinus communis with ricin D isoform. During the purification of ricin E using ion-exchange and size-exclusion chromatography, SDS-CGE was found to be useful for monitoring the efficiencies of purification steps. SDS-CGE showed that the molecular size of ricin E was not significantly different from that of ricin D, which was confirmed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. CIEF was useful for discriminating ricin E from ricin D based on their isoelectric points (pI). The pI values of ricin E and D were 8.6-8.8 and 7.0-7.4, respectively. This study demonstrates the usefulness of SDS-CGE and CIEF for the characterization of ricin toxins.

Performance and Operation of Biological Activated Carbon (생물활성탄접촉조의 성능과 조작)

  • Lee, Gangchoon;Yoon, Taekyung
    • Journal of Korean Society on Water Environment
    • /
    • 제22권1호
    • /
    • pp.83-90
    • /
    • 2006
  • Performance and operation of BAC in ozone-BAC advanced water treatment process were investigated using the pilot scale test plant built in D water purification plant. The performance was evaluated by the removal efficiencies of DOC, BDOC, ammonia nitrogen and THMs. The effect of EBCT on DOC removal was experimented for an effective operating condition, and the amount of attached biofilm was analyzed in various water temperatures and position of BAC. Two removal mechanisms, adsorption and biological decomposition by attached biofilm, were predominant to decrease the concentration of various contaminants. DOC was removed 40%, and the removal rate was decreased in winter time due to the lowered activity of attached biofilm. BDOC was effectively removed. THMs and ammonia nitrogen were mainly removed not in ozonation process but in BAC. Water temperature deeply influenced in removal efficiency of ammonia nitrogen. The amount of attached biofilm depended on water temperature and height of packed activated carbon column. Considering DOC removal efficiency and design EBCT of commercial BAC plant, the proper EBCT was 12.5 minutes.

Evaluation of Purification Efficiency of Passive Treatment Systems for Acid Mine Drainage and Characterization of Precipitates in Ilwal Coal Mine (일월탄광에서 유출되는 산성광산배수 자연정화시설의 정화 효율 평가 및 침전물의 특성연구)

  • Ryu, Chung Seok;Kim, Yeong Hun;Kim, Jeong Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • 제27권2호
    • /
    • pp.97-105
    • /
    • 2014
  • Artificial precipitation ponds, consisting of three steps of oxidation pond, successive alkalinity producing system (SAPS) and swamp, were constructed for the treatment of the acid mine drainage from the Iwal coal mine. The efficacies of the passive treatment system in terms of neutralization of mine water and removal of dissolved ions were evaluated by the chemical analyses of the water samples. Mine water in the mine adits was acidic, showing the pH value of 2.28-2.42 but the value increased rapidly to 6.17-6.53 in the Oxidation pond. The purification efficiencies for the removal of Al and Fe were 100%, whereas those of $SO_4$, Mg, Ca, and Mn were relatively low of 50%, 40%, 24%, and 59%, respectively. These results indicate a need for application of additional remediation techniques in the passive treatment systems. The precipitates that formed at the bottom of the mine water channels were mainly schwertmannite ($Fe_8O_8(OH)_6SO_4$) and those in the leachate water were 2-line ferrihydrite ($Fe_2O_3{cdot}0.5H_2O$).

[Retracted]Gas Mask Removal Efficiency of CO, HCl, HCN, and SO2 Gas Produced by Fire ([논문철회]화재용 방독면의 CO, HCl, HCN, SO2 연소생성물 제거효율)

  • Kong, Ha-Sung;Gong, Ye-Som;Kim, Sang-Heon
    • Fire Science and Engineering
    • /
    • 제29권4호
    • /
    • pp.57-60
    • /
    • 2015
  • The removal efficiencies by elastic fire gas mask of toxic gases CO, HCl, HCN, and $SO_2$ produced by a fire have a key role in saving lives. The elastic fire gas mask comprises a visible window, elastic hood, gas purification canister, and air vent. It does not have hair or neck thongs, which makes it easy to use and put on quickly. This research examined the removal efficiency of toxic gases by such a mask. The removal efficiencies for CO with a background concentration of 2505.0 ppm were 99.99 and 99.98% after 3.5 and 8.5 min, respectively. The residual CO concentration was drastically increased after 8.5 min. The removal efficiencies for HCl, HCN, and $SO_2$ with background concentrations of 1003.0, 399.0, and 100.3 ppm, respectively, were 100% after 20 min.

Performance Evaluation of Soil Media for Water Quality Purification at LID Application (분산형 빗물관리시설 적용을 위한 수질정화기능 여재 성능 평가)

  • Park, Chan Gi;Kim, Chun Soo;Kim, Hwang Hee;Yoo, Sung-Yeol;Jeon, Ji Hong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • 제56권6호
    • /
    • pp.85-91
    • /
    • 2014
  • In this study, the water quality purification of new medias which were NPS media, hyugato, mineral stone, charcoal for applying soil media of Integrated Management Practices (IMPs) of Low Impact Development (LID) were evaluated. The influent concentrations of COD, T-N, and T-P were 117.8 mg/L, 17.1 mg/L, and 2.062 mg/L, respectively. The infiltration capacities of NPS media, hyugoto, mineral stone, charcoal, and gravel were $7.1{\times}10m/s$, $7.3{\times}10^{-5}m/s$, $7.9{\times}10^{-5}m/s$, $6.0{\times}10^{-5}m/s$, respectively. All media meet criteria of infiltration capacity as surface soil layer at IMPs which is over $1.0{\times}10^{-5}m/s$. Maximum removal rates of COD, T-N, and T-P occurred at Charcoal with 98 % of COD removal rate, NPS with 78 % of T-N removal rate, and hyugato with 75 % fo T-P removal rate, respectively. For more high removal efficiency of all water quality item, the mixed media which is 4.5(NPS media): 1(charcoal) : 4.5 (hyugato) as volume ratio was evaluated. The infiltration capacity of mixed media was $7.9{\times}10^{-5}m/s$ and met the criteria of infiltration as surface soil layer. The water quality removal efficiencies of mixed media were very high with showing 70 % for COD, 85 % for T-N, and 71 % for T-P. The mixed media could purify the water quality of surface runoff and was recommended to used at the LID site of ground water quality problem.

Supercritical Fluid Extraction of Physiologically Active materials from Agaricus blazei Fruiting Bodies (Agaricus blazei 자실체로부터 초임계 유체를 이용한 생리활성물질 추출공정)

  • 최정우
    • KSBB Journal
    • /
    • 제15권4호
    • /
    • pp.408-410
    • /
    • 2000
  • The supercritical fluid extraction(SFE) technique was applied for the isolation and purification of nonpolar physiologically acitve mateials from Agaricus blazei fruiting bodies. the qualitative analysis of extract was accomplished by gas chromatography-mass spectrometer(GC-MS) and extract was determined as linoleic acid(cis-9 cis-12-octadecadienoic acid) In order to obtain the optimum operating conditions of supercritical fluid extraction process the various temperatures and pressures were applied for process operation. From the comparison of exraction efficiencies $50^{\circ}C and 200 kg_f/cm^2$ were determined as optimum conditions.

  • PDF

Emission After-Treatment System of Model Gas Turbine Using Catalyst (촉매를 이용한 모형가스터빈 연소기의 배기후처리 시스템)

  • Lee, Y.H.;Lee, J.S.;Bae, D.S.;Lee, D.H.
    • Journal of Power System Engineering
    • /
    • 제7권3호
    • /
    • pp.12-17
    • /
    • 2003
  • The purpose of this study is to observe the purification characteristics of NOx, CO and HC in various catalysts and excess air ratio conditions. For this purpose, we installed various catalysts on the back stream of the coaxial diffusion burner with swirler. As the result, in the case of NOx, Pt-Rh catalyst shows very high value that is more than 90%-conversion efficiency without the relation with the excess air ratio. After excess air ratio of ${\alpha}=1.14$, it shows that the conversion efficiencies were more than 80% in the every Pt catalyst in the view of conversion of every exhaust with changing of the excess air ratio.

  • PDF

Purification of Stream Water Quality by Subsurface-flow Wetland Facility (습지여상시설을 이용한 하천 수질정화)

  • Jung, Yong-Jun;Lim, Ki-Sung
    • Journal of Korean Society on Water Environment
    • /
    • 제22권3호
    • /
    • pp.456-461
    • /
    • 2006
  • The facility of constructed wet land combined with filter media was examined in order to improve the water quality of a polluted stream, which has been performed as a part of national projects. Throughout 2 years of operation for a stream, it can provide the design and operating parameters for the purpose of future construction. The influent flow rate was about 50% against the design capacity. The removal efficiencies of BOD, $COD_{Mn}$, SS, T-N and T-P were 62.9%, 47.1%, 74.8%, 22.4% and 33.5%, respectively. In order to keep this facility stable, the removal of surface filter media and supplement should be periodically conducted. In addition, the proper selection of sites is recommended not to be flooded.