• 제목/요약/키워드: pure state

검색결과 550건 처리시간 0.027초

Al(Si, Cu)합금막의 플라즈마 식각후 표면 특성 (Surface properties of Al(Si, Cu) alloy film after plasma etching)

  • 구진근;김창일;박형호;권광호;현영철;서경수;남기수
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권3호
    • /
    • pp.291-297
    • /
    • 1996
  • The surface properties of AI(Si, Cu) alloy film after plasma etching using the chemistries of chlorinated and fluorinated gases with varying the etching time have been investigated using X-ray Photoelectron Spectroscopy. Impurities of C, Cl, F and O etc are observed on the etched AI(Si, Cu) films. After 95% etching, aluminum and silicon show metallic states and oxidized (partially chlorinated) states, copper shows Cu metallic states and Cu-Cl$_{x}$(x$_{x}$ (x$_{x}$ (1

  • PDF

리튬이온 이차전지 양극활물질 $LiMn_{2-x}Cu_{x}O_{4}$의 제작과 전극특성에 관한 연구 (The study on Fabrication and Characterization of $LiMn_{2-x}Cu_{x}O_{4}$for cathode material of Lithium-ion Battery)

  • 박종광;고건문;홍세은;윤기웅;안용호;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.713-716
    • /
    • 2001
  • In many papers, the electrochemical analysis of LiMn$_2$O$_4$shows the transition results of Mn$^{3+}$ ion. Charge ordering is accompanied by simultaneous orbital ordering due to the Jahn-Teller effect in Mnl$^{3+}$ ions. To analyze the cycle performance of LiMn$_{2-x}$Cu$_{x}$ O$_4$as the cathode of 4 V class lithium secondary batteries, XRD, TGA analysis were conducted. Although the cycle performance of the LiMn$_{2-x}$Cu$_{x}$ O$_4$was improved from pure LiMn$_2$O$_4$, the discharge capacity was significantly lower than LiCoO$_2$. In this paper, We study the Electrochemical characterization and enhanced stability of Cu-doped spinels in the LiMn$_{2-x}$Cu$_{x}$ O$_4$upon initial cycling.l cycling.

  • PDF

Dynamics of a Bose-Einstein Condensate on Changing Speeds of an Atomchip Trap Potential

  • Kim, Seung Jin;Noh, Jae June;Kim, Min Seok;Lee, Jin Seung;Yu, Hoon;Kim, Jung Bog
    • Journal of the Optical Society of Korea
    • /
    • 제18권6호
    • /
    • pp.633-638
    • /
    • 2014
  • We report experimental behaviors of condensed $^{87}Rb$ atoms responding to changes in the trap potential of the atomchip. The two-types of adiabatic and non-adiabatic overall changes were implemented by changing the ramp-down speed of the chip-wire current, which can dominantly modify the one-axis magnetic field gradient. Under the adiabatic process, a pure condensate stayed in the initial spin state and collectively oscillated with both monopole and dipole modes, while an atomic cloud above the critical temperature exhibited sound waves in a dense ultracold gas. On the other hand, Bose-Einstein condensate atoms with non-adiabatic perturbation were split into spatially different positions by spin states through spin-flip. We investigated the split ratio among spin states depending on final evaporation frequency. Potential changes, of course, cause collective oscillations regardless of the changing process.

Design strategy of hybrid stay cable system using CFRP and steel materials

  • Xiong, Wen;Cai, C.S.;Xiao, Rucheng;Zhang, Yin
    • Steel and Composite Structures
    • /
    • 제13권1호
    • /
    • pp.47-70
    • /
    • 2012
  • To enhance cable stiffness, this paper proposed a combined application of carbon fiber reinforced polymers (CFRP) and steel materials, resulting in a novel type of hybrid stay cable system especially for the cable-stayed bridges with main span lengths of 1400~2800 m. In this combination, CFRP materials can conserve all their advantages such as light weight and high strength; while steel materials help increase the equivalent stiffness to compensate for the low elastic modulus of CFRP materials. An increase of the equivalent stiffness of the hybrid stay cable system could be further obtained with a reasonable increase of its safety factor. Following this concept, a series of parametric studies for the hybrid stay cable system with the consideration of stiffness and cost were carried out. Three design strategies/criteria, namely, best equivalent stiffness with a given safety factor, highest ratio of equivalent stiffness to material cost with a given safety factor, and best equivalent stiffness under a given cost were proposed from the stiffness and cost viewpoints. Finally, a comprehensive design procedure following the proposed design strategies was suggested. It was shown that the proposed hybrid stay cable system could be a good alternative to the pure CFRP or traditional steel stay cables in the future applications of super long span bridges.

저고상율 소재의 유동 및 응고현상을 고려한 레올로지 성형공정해석 (Process Analysis for Rheology Forming Considering Flow and Solidification Phenomena in Lower Solid Fraction)

  • 정영진;조호상;강충길
    • 한국정밀공학회지
    • /
    • 제18권9호
    • /
    • pp.156-164
    • /
    • 2001
  • Two-dimensional solidification analysis during rheology forming process of semi-solid aluminum alloy has been studied. Two-phase fluid flow model to investigate the velocity field and temperature distribution is proposed. The proposed mathematical model is applied to the die shape of the two types. To calculate the velocity and temperature fields during rheology forming process, the earth governing equation correspondent to the liquid and solid region are adapted. Therefore, each numerical models considering the solid and liquid region existing within the semi-solid material have been developed to predict the deflect of rheology forming gnarls. The Arbitrary Boundary Maker And Cell (ABMAC) method is employed to solve the two-phase flow model of the Navier-Stokes equation. Theoretical model on the basis of the two-phase flow model is the mixture rule of solid and liquid phases. This approach is based on the liquid and solid viscosity. The liquid viscosity is pure liquid state value, however solid viscosity is considered as a function of the shear rate, solid fraction and power law curves.

  • PDF

Fabrication and Cell Culturing on Carbon Nanofibers/Nanoparticles Reinforced Membranes for Bone-Tissue Regeneration

  • Deng, Xu Liang;Yang, Xiao Ping
    • Carbon letters
    • /
    • 제13권3호
    • /
    • pp.139-150
    • /
    • 2012
  • Poly-L-lactic acid (PLLA), PLLA/hydroxyapatite (HA), PLLA/multiwalled carbon nanotubes (MWNTs)/HA, PLLA/trifluoroethanol (TFE), PLLA/gelatin, and carbon nanofibers (CNFs)/${\beta}$-tricalcium phosphate (${\beta}$-TCP) composite membranes (scaffolds) were fabricated by electrospinning and their morphologies, and mechanical properties were characterized for use in bone tissue regeneration/guided tissue regeneration. MWNTs and HA nanoparticles were well distributed in the membranes and the degradation characteristics were improved. PLLA/MWNTs/HA membranes enhanced the adhesion and proliferation of periodontal ligament cells (PDLCs) by 30% and inhibited the adhesion of gingival epithelial cells by 30%. Osteoblast-like MG-63 cells on the randomly fiber oriented PLLA/TEF membrane showed irregular forms, while the cells exhibited shuttle-like shapes on the parallel fiber oriented membrane. Classical supersaturated simulated body fluids were modified by $CO_2$ bubbling and applied to promote the biomineralization of the PLLA/gelatin membrane; this resulted in predictions of bone bonding bioactivity of the substrates. The ${\beta}$-TCP membranes exhibit good biocompatibility, have an effect on PDLC growth comparable to that of pure CNF membrane, and can be applied as scaffolds for bone tissue regeneration.

현직 한의사의 한의진단 현황 조사 보고 (An investigative report on the clinical use of traditional diagnosis modalities among Korean Medicine Doctors)

  • 장재순;조승모;김기왕
    • 대한한의진단학회지
    • /
    • 제17권2호
    • /
    • pp.156-168
    • /
    • 2013
  • Objectives Although there have been someone who pointed out declining tendency of pure traditional diagnosis, there are no objective survey results on present state of diagnosis among Korean Medicine Doctors (KMDs). So we did a descriptive survey study to show traditional diagnostic modality usage among them. Materials and methods: 73 samples of responded questionnaire in Busan area were collected and descriptively studied. Results (1) U code (in KCD-6) usage showed low level (28.7%). (2) Diagnostic apparatuses for traditional medicine are rarely used. For example, pulse diagnosis machine was reported to be used only by 9.7 % of KMDs. (3) KMDs still prefer the treatment based on pattern identification and symptomatic therapy rather than treatments based on disease identification of modern biomedicine. Conclusion Overall, the portion of pattern identification is still high among KMDs, some kind of diagnostic methods which support pattern identification showed lack of usage.

상태감시컴포넌트를 사용한 OPRoS 프레임워크의 고장감내 기법 (State-Monitoring Component-based Fault-tolerance Techniques for OPRoS Framework)

  • 안희준;안상철
    • 제어로봇시스템학회논문지
    • /
    • 제16권8호
    • /
    • pp.780-785
    • /
    • 2010
  • The OPRoS (Open Platform for Robotic Services) framework is proposed as an application runtime environment for service robot systems. For the successful deployment of the OPRoS framework, fault tolerance support is crucial on top of its basic functionalities of lifecycle, thread and connection management. In the previous work [1] on OPRoS fault tolerance supports, we presented a framework-based fault tolerance architecture. In this paper, we extend the architecture with component-based fault tolerance techniques, which can provide more simplicity and efficiency than the pure framework-based approach. This argument is especially true for fault detection, since most faults and failure can be defined when the system cannot meet the requirement of the application functions. Specifically, the paper applies two widely-used fault detection techniques to the OPRoS framework: 'bridge component' and 'process model' component techniques for fault detection. The application details and performance of the proposed techniques are demonstrated by the same application scenario in [1]. The combination of component-based techniques with the framework-based architecture would improve the reliability of robot systems using the OPRoS framework.

Effect on 4H-SiC Schottky Rectifiers of Ar Discharges Generated in A Planar Inductively Coupled Plasma Source

  • Jung, P.G.;Lim, W.T.;Cho, G.S.;Jeon, M.H.;Lee, J.W.;Nigam, S.;Ren, F.;Chung, G.Y.;Macmillan, M.F.;Pearton, S.J.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제3권1호
    • /
    • pp.21-26
    • /
    • 2003
  • 4H-SiC Schottky rectifiers were exposed to pure Ar discharges in a planar coil Inductively Coupled Plasma system, as a function of source power, of chuck power and process pressure. The reverse breakdown voltage ($V_B$) decreased as a result of plasma exposure due to the creation of surface defects associated with the ion bombardment. The magnitude of the decrease was a function of both ion flux and ion energy. The forward turn-on voltage ($V_F$), on-state resistance ($R_{ON}$) and diode ideality factor (n) all increased after plasma exposure. The changes in all of the rectifier parameters were minimized at low power, high pressure plasma conditions.

초음속 페탈 이젝터 시스템에 관한 실험적 연구 (An Experimental Study on the Supersonic Petal Ejector System)

  • 이준희;김중배;최보규;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2145-2150
    • /
    • 2003
  • Ejector system is one of fluid machinery which can entrain the fluid in low pressure part and transport it to the higher pressure part. The ejector system has been widely used for the purpose of obtaining high-vacuum state, fluid transport, thrust augmentation, etc. It can transport a large capacity of fluid with relatively small device of no any moving parts, and thus seldom causes mechanical troubles. However, the conventional ejector system has been pointed out that its overall efficiency is quite low compared with other fluid machinery since it is derived by only the pure shear stresses. In the present study, 4, 6, and 8 lobed petal nozzles with a design Mach number of 1.7 are adopted as a primary nozzle to improve the ejector performance, and are compared with a conventional circular nozzle. The static pressures along the diffuser wall are measured to qualify the flow field inside the supersonic petal ejector system.

  • PDF