• 제목/요약/키워드: pumping-current

검색결과 188건 처리시간 0.026초

Bi-2223 팬케익부하 충전용 히터-트리거 스위칭 장치의 설계 및 제작 (Design and Fabrication of Heater-triggered Switching System for the Charging of Bi-2223 Pancake Load)

  • 김영식;윤용수;배덕권;안민철;임대준;김호민;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.43-48
    • /
    • 2004
  • This paper deals with design and fabrication of heater-triggered switching system for the high-Tc superconducting (HTS) power supply with series-connected double-pancake load. Amongst all components, heater triggering is the most important element for the performance of HTS power supply. To fabricate the optimal heater-triggered system, its characteristics have been analysed through the simulation and expriment. The thermal analysis of switching parts of the Bi-2223 solenoid according to the heater input was carried out. Based upon the analysis, 8A electromagnet current and 1.5A DC Heater current were optimally derived, and 8s and 20s for the pumping period were selected in this experiment. In the experiment. the maximum pumping current reached about 24A with Bi-2223 pancake load of 6mH.

내부 승압 전원 발생기와 기판 인가 전원 발생기의 펌핑 수단을 공유한 전원 전압 발생기 (A Unified Voltage Generator Which Merges the Pumping Capacitor of Boosted Voltage Generator and Substrate Voltage Generator)

  • 신동학;장성진;전영현;이칠기
    • 대한전자공학회논문지SD
    • /
    • 제40권11호
    • /
    • pp.45-53
    • /
    • 2003
  • DRAM에서 사용되는 내부 승압 전원 전압과 기판인가 전원 전압 발생기를 공유함으로써 단일 Charge Pump에서 승압 전원과 기판 전원을 동시에 발생시키는 회로를 설계하였다. 이 회로는 0.14um의 DRAM 공정을 사용하여 기존 보다 전력 소모를 30%, 전체 면적을 40% 그리고 Pumping capacitor 면적을 29.6% 각각 감소하였으며 또한 전류 공급 효율을 13.2% 향상 시켰다. Charge Recycling 기법을 적용하여 Pumping capacitor의 Precharge 구간 동안 소모되는 전류를 75% 감소하였다.

초전도자석 충전을 위한 BSCCO 히터트리거 스위치의 특성 연구 (Study on the Characteristics on the Heater-Triggered Switch for the Charging of a Superconducting Magnet)

  • 김영식;배덕권;안민철;윤용수;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.196-199
    • /
    • 2003
  • Characteristics of a heater-triggered switch has been analyzed through the simulations and experiments. It was for the charging of Bi-2223 double pancake load with 1.7 mH and two heaters were used. The timing of the sequential control and the heating current with two heaters are important factors to generate pumping-current. The thermal analysis of the switch considering the heater input and time was carried out. Based on the analysis just mentioned. heater-triggered switch was fabricated. Characteristic analysis was carried out through two modes having different sequential timing controls. Maximum pumping-current reached 18 A and the pumping rate was 113 mA/s at that time.

  • PDF

저온초전도전원장치의 시스템 특성해석 및 요소실험 (Characteristic Analysis and Experiments on Components of Low-Tc Power Supply)

  • 윤용수;주민석;고태국
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권2호
    • /
    • pp.76-81
    • /
    • 2004
  • This paper deals with characteristic analysis and experiments on components of low-Tc(LTS) power supply. A LTS power supply consists of two exciters, a rotor, a stator, and an LTS magnet. The power supply has eight rotating poles, which make rotational magnetic flux. These flux penetrate superconducting sheets and cause currents which charge an LTS load. In this experiment, a 25.8mH LTS magnet was used, and rotor revolutions from 30 to 300rpm were used. In order to measure the pumping-current with respect to the magnet flux changes, a hall sensor was installed at the center of the LTS magnet. The experimental observations have been compared with the theoretical predictions. In this experiment, the pumping-current has reached about 372A.

초전도 Power Supply의 전류펌핑 과정에서 발생하는 조기 퀜치발생 진단 (A study on the Detection of Premature Quench Generated in the Process of Current Pumping in a Superconducting Power Supply)

  • 김호민;배준한;노정섭;심기덕;장원갑;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.244-246
    • /
    • 1997
  • This paper is to analyze the Premature Quench characteristics of a rotating magnet type superconducting fluxpump and consider the method of detecting and protecting this premature quench. Practically, there is contact resistance between the fluxpump and the load, namely the S.C. magnet. The thermal increase due to the contact resistance cause the premature quench before the charging current amounts to the critical current of S.C magnet. Therefore, this paper is devoted to solving the heat equation on contact region using cylindrical coordinates and to calculating the rate of thermal increase during the current is pumped up. Doing so, the predictive value of the maximum pumping current is obtained. It has been verified that the results of simulation are coincident with those of experiment. It must be considered essentially to minimize the contact resistance in designing the S.C fluxpump system in order to protect the premature quench and improve the maximum pumping current.

  • PDF

새로운 형태의 영구전류모드용 초전도 전원장치의 제작 및 운전특성 (The Fabrication and Operational Characteristics of a Novel Type Superconducting Power Supply for Persistent Current Mode)

  • 김호민;윤용수;고태국;한태수;장승찬;오상수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권12호
    • /
    • pp.771-777
    • /
    • 2000
  • This paper deals with the design and fabrication of a novel superconducting power supply system, and characteristics have been investigated through experiments. Superconducting power supply consists of rotating and static parts, and superconducting magnet. In this experiment, superconducting foils were placed in parallel within the static part of the machine, pumping currents were measured with respect to rotor speeds and excitation currents. In addition, in order to observe the rotating flux distribution in the superconducting foils, several hall-sensors were placed in it. With the flux distribution acquired, effect of the flux on the superconducting foil during the process of current pumping has been discussed. Also, the general operational characteristics of the superconducting power supply system have been investigated on the basis of the current and voltage data, and magnetic field values acquired through the experiments.

  • PDF

TFT -LCD 구동 IC용 커패시터 내장형 DC-DC 변환기 설계 (A DC-DC Converter Design with Internal Capacitor for TFT-LCD Driver IC)

  • 임규호;강형근;이재형;손기성;조기석;백승면;성관영;이용진;박무훈;하판봉;김영희
    • 한국정보통신학회논문지
    • /
    • 제10권7호
    • /
    • pp.1266-1274
    • /
    • 2006
  • 본 논문에서는 TFT-LCD 구동 IC 모듈의 소형화측면에서 유리한 DC-DC 변환기 회로인 펌핑 커패시터 내장형 비중첩 부스트-클락 전하펌프 (Non-overlap Boosted-Clock Charge Pump: NBCCP) 회로가 제안되었다 .2VDC 전압으로 스윙하는 비중첩 부스트-클럭의 사용으로 기존의 펌핑 커패시터 내장형 크로스-커플드 전하펌프에 비해 펌핑 단의 수를 반으로 줄일 수 있었고, 전하 펌핑 노드의 펌핑된 전하가 입력 단으로 역류되는 현상을 방지하였다 . 그 결과 제안된 펌핑 커패시터 내장형 비중첩 부스트-클럭 전하펌프 회로는 기존의 펌핑 커패시터 내장형 크로스-커플드 전하펌프에 비해 펌핑 전류가 증가하였고, 레이아웃 면적은 감소되었다. 제안된 TFT-LCD 구동 IC용 DC-DC 변환기 회로를 $0.18{\mu}m$ Triple-Well CMOS 공정을 사용하여 설계하고, 테스트 칩을 제작 중에 있다.

A Simple ZVZCS Sustain Driver for a Plasma Display Panel

  • Yi Kang-Hyun;Han Sang-Kyoo;Choi Seong-Wook;Kim Chong-Eun;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • 제6권4호
    • /
    • pp.298-306
    • /
    • 2006
  • A high efficiency and low cost sustain driver for a plasma display panel (PDP) utilizing a current pumping method is proposed. The main concept of the proposed circuit is using the current source to charge and discharge the panel. As a result, all power switches can achieve zero voltage switching (ZVS) and every auxiliary switch can also achieve zero current switching (ZCS). Since the inductor current can compensate for the discharge current, the current stress of all the power switches can be reduced considerably. Furthermore, it has features such as a simpler structure, less mass, lower cost, and lower electromagnetic interference than in previous circuits.

PV Water Pumping 시스템을 위한 BLDC 모터 제어 (Brushless DC Motor Control for Photovoltaic Water-Pumping System)

  • 김성남;최성호;조정민;전기영;이승환;한경희
    • 전기학회논문지P
    • /
    • 제50권3호
    • /
    • pp.109-116
    • /
    • 2001
  • In this paper, we adapted BLDC motor to PV water pumping systems to maintain high efficiency in the wide speed area. Also, to design confidence we adapted the vector control that drive the maximum torque at each speed limit. We designed optimal gain value of current, speed and pressure PI controller. Inverter gate pulse used Space Vector PWM to reduce torque pulsation of BLDC motor. According to, it was improve general matters of high water storage tank method by direct water supply pumping method.

  • PDF

Evanescent-field Q-switched Yb:YAG Channel Waveguide Lasers with Single- and Double-pass Pumping

  • Bae, Ji Eun;Choi, Sun Young;Krankel, Christian;Hasse, Kore;Rotermund, Fabian
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.180-185
    • /
    • 2021
  • A femtosecond-laser inscribed Yb:YAG surface channel waveguide (WG) laser with single-walled carbon nanotubes deposited on the top surface of the WG was passively Q-switched by evanescent field interaction. Q-switched operation of the 14-mm-long compact Yb:YAG WG laser was achieved near 1031 nm with two different pumping schemes (single- and double-pass pumping) with an output coupling transmission of 91%. The Q-switched pulse characteristics depending on the absorbed pump power were investigated for both pumping geometries and analyzed in detail based on theoretical modeling. The best performances (energy/pulse duration) for each configuration were 204.4 nJ/75 ns at a repetition rate of 1.87 MHz, and 201.1 nJ/81 ns at 1.75 MHz for single- and double-pass pumping, respectively.