• Title/Summary/Keyword: pumping time

Search Result 306, Processing Time 0.021 seconds

Extending the Pressure Limit for Turbomolecular Pump up to 133 Pa by using Conductance-Reducer and Measuring the Pressure Differences in Vacuum Chamber (확장한 진공용기 내부의 압력구배 측정)

  • Hong, S.S.;Khan, Wakil;Kang, S.W.;Yun, J.Y.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • A dynamic flow system has been developed which can be used for vacuum gauge calibration by comparison method - a calibration method in which the reading of the gauge under calibration is compared to another calibrated vacuum gauge called the "secondary standard" - and other vacuum-related experiments. The chamber of the calibration system is pumped by a turbomolecular pump (TMP), backed by a scroll pump. As maximum acceptable pressure at the inlet of a TMP is 0.1 Pa, above which the TMP decelerates, the pumping speed decreases and it becomes more difficult to adjust pressure under such circumstances. In the present work, high pressures of up to 133 Pa have been generated in the chamber of the newly developed dynamic flow control system by installing a well-designed conductance-reducer in the by-pass line and, at the same time, operating the TMP in safe mode. In addition, the gas flow and pressure distribution within the chamber have been investigated for the entire pressure range (0.1 Pa ~ 133 Pa) while generating pressure dynamically. Maximum deviations in pressure (1.6 %) were observed at point C on the chamber, which is close to the gas inlet port on the top of the chamber.

A Surveying on the Sewage System in Seoul (수도권 하수방제 방식에 관한 조사 연구)

  • 남궁악
    • Water for future
    • /
    • v.15 no.2
    • /
    • pp.11-22
    • /
    • 1982
  • This study is to find out the reasonable drainage system of sewerage in connection with the geographical conditions, the form of city, and the problem of sewerage in and around Seoul. (1) In supplying the sewerage sewer, the separating system is desirable in connection with the problem of sewerage disposal in future. However, in the existing urban district, the conjunction system is used because of the large amount invested according to the diversion of the sewer of the separation system and the influence of the traffic communication. The sewer of the separating system should be used in the case of the fundamental reconstruction of structure as the redevelopment of the urban district or the subway and new-development of area. Therefore, the separating system should be used completely until the goal year. (2) Drainage area was divided for the natural flowing, considering that the 38 streams and topography paly a role of the main stream of drainage. There are the branches, Guyui, Dug-island, Jayang, Hannam, Banpo, Amsa whose divisions are impossible. In these branches, the drain planning was suggested a forced control method by using the exiting pond age and the pumping station. (3) The best available method which improbes the water quality in Han river is as follows. The sewerage is catched and carried to the sewerage disposal plant by establishing the intercept sewer in both or one side of stream. At the same time, the groudwater volume which springs in each stream is drained separatively.

  • PDF

Groundwater Flow Model for the Pollutant Transport in Subsurface Porous Media Theory and Modeling (지하다공질(地下多孔質) 매체(媒體)속에서의 오염물질이동(汚染物質移動) 해석(解析)을 위한 지하수(地下水)흐름 모형(模型))

  • Cho, Won Cheal
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.3
    • /
    • pp.97-106
    • /
    • 1989
  • This paper is on the modeling of two-dimensional groundwater flow, which is the first step of the development of Dynamic System Model for groundwater flow and pollutant transport in subsurface porous media. The particular features of the model are its versatility and flexibility to deal with as many real-world problems as possible. Points as well as distributed sources/sinks are included to represent recharges/pumping and rainfall infiltrations. All sources/sinks can be transient or steady state. Prescribed hydraulic head on the Dirichlet boundaries and fluxes on Neumann or Cauchy boundaries can be time-dependent or constant. Sources/sinks strength over each element and node, hydraulic head at each Dirichlet boundary node and flux at each boundary segment can vary independently of each other. Either completely confined or completely unconfined aquifers, or partially confined and partially unconfined aquifers can be dealt with effectively. Discretization of a compound region with very irregular curved boundaries is made easy by including both quadrilateral and triangular elements in the formulation. Large-field problems can be solved efficiently by including a pointwise iterative solution strategy as an optional alternative to the direct elimination solution methed for the matrix equation approximating the partial differential equation of groundwater flow. The model also includes transient flow through confining leaky aquifers lying above and/or below the aquifer of interest. The model is verified against three simple cases to which analytical solutions are available. The groundwater flow model shall be combined with the model of pollutant transport in subsurface porous media. Then the combined model, with the applications of the Eigenvalue technique and the Dynamic system theory, shall be improved to the Dynamic System Model which can simulate the real groundwater flow and the pollutant transport accurately and effectively for the analyses and predictions.

  • PDF

Installation Technology and Behavior of Silty Clay Filled Geotextile Tube (실트질 점토 채움 시 지오텍스타일 튜브의 거동 및 시공 방법에 관한 연구)

  • Shin, Eun-Chul;Oh, Young-In
    • Journal of the Korean Geosynthetics Society
    • /
    • v.1 no.1
    • /
    • pp.13-21
    • /
    • 2002
  • Geotextile tubes hydraulically or mechanically filled with dredged materials have been applied in hydraulic and coastal engineering in recent years(detached breakwater, groins and jetty). The geotextile tubes are made of sewn geosynthetics sheets. If the sandy soil is use to fill material, these inlets should be spaced closely to assure uniform filling of the tubes because sandy soil and geosynthetic is very pervious. However, the clayey soil or contaminated slurry is used, the inlets can be located relatively long distance. The fine clayey particles tend to rapidly blind the fabric slowing down water escape through the geotextile. This paper presents a field test result of a geotextile tube in the land reclamation project for the Songdo New City construction site. The dredged silty clay was dredged by the dredging ship and hydraulically pumped into the geotextile tube. The height of geotextile tube was measured at every filling stage and also measured width and diameter of geotextile tube with the elapsed time. Based on the test results, if the clayey filling material is used, the pumping step must be divided 3~4 stages for drainage and sediment. After complete drainage, the height of the geotextile tube reduces by approximately 50%.

  • PDF

The Effect of Decentralized Rainwater Tank System on the Reduction of Peak Runoff - A Case Study at M Village - (빗물저류조의 분산배치에 따른 첨두유출 저감효과 분석 - M 마을 사례 -)

  • Han, Moo-Young;Kum, So-Yoon;Mun, Jung-Soo;Kwak, Dong-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.1
    • /
    • pp.65-73
    • /
    • 2012
  • Recently climate change and increase of surface runoff caused the urban flooding. Traditional way of dealing with urban flooding has been to increase the sewer capacity or construction of pumping stations, however, it is practically almost impossible because of time, money and traffic problems. Multipurpose DRMS (Decentralized Rainwater Management System) is a new paradigm proposed and recommended by NEMA (National Emergency Management Agency) for both flood control and water conservation. Suwon City has already enacted the ordinance on sound water cycle management by DRMS. In this study, a flood prone area in Suwon is selected and analysis of DRMS has been made using XP-SWMM for different scenarios of RT installation with same total rainwater tank volume and location. Installing one rainwater tank of 3,000$m^3$ can reduce the peak flow rate by 15.5%. Installing six rainwater tanks of 500$m^3$ volume in the area can reduce the peak flow rate by 28%. Three tanks which is concentrated in the middle region can reduce peak rate more than evenly distributed tanks. The method and results found from this study can be used for the design and performance prediction of DRMS at a flood prone area by supplementing the existing sewer system without increase of the sewer capacity.

Hydrologic Characterization through Ground Water Monitoring in a Coastal Aquifer (해안 대수층에서 지하수 장기 모니터링을 통한 수리 특성 조사)

  • Shim, Byoung-Ohan;Lee, Chol-Woo
    • Economic and Environmental Geology
    • /
    • v.44 no.3
    • /
    • pp.239-246
    • /
    • 2011
  • Groundwater in small islands is used as main water resource but the overuse of groundwater may cause seawater intrusion and temperature decrease in geothermal wells. This study aimed to characterize the hydrogeology of Maeum-ri area in Seokmo Island of Ganghwagun using long-term monitoring at groundwater wells and geothermal wells. In the monitoring period seasonal water level change, consistent drop or increase of water levels are not detected. The groundwater temperature about 10m below ground surface shows year cycle variation having two to five months difference with ambient temperature cycle. The storativity was calculated by tidal method. The storativity estimated by adapting tidal efficiency factor showed some larger values than that by using tidal time lag. The result suggested that the tidal method assuming several assumptions on aquifer condition may produce broad ranges but the calculated ranges at this application are reasonable. The similar shape of groundwater level change and tidal effects was observed at several wells clustered east-south-east direction which may implicate the distribution of vertical fracture system strongly related with groundwater flow channels. The applied methodology and study results will bc valuable to evaluate optimal pumping rate for the preservation of groundwater resources, and to manage geothermal development.

Proposal of Design Criteria on Multi-functional Tunnel for the Urban Traffic Tunnel to Flooding Bypass (도심지 홍수저감과 교통량 분담을 위한 다기능 대심도 터널 설계 기준 방안 제시)

  • Kwon, Soonho;Kim, Junghwan;Chung, Gunhui
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3518-3524
    • /
    • 2015
  • Spatial and time variation of the precipitation in Korea is high, therefore, more than 2/3 of the annual precipitation is concentrated during the rainy season. Climate change also causes the intensive rainfall in the area of dense population, thus the occurrence frequency of the heavy flood in the impervious area has been increased. Therefore, the structural food mitigation measures such as the construction of the higher design frequency stormwater pipes, pumping stations, and/or detention ponds. The flood bypass tunnel or retention storage is also one of the efficient structures to mitigate flood damage in the urban area. However, the economic feasibility has been controversial because the flood bypass tunnel might be used once or twice a year. To solve the problem, the multi-functional tunnel for the urban traffic and flooding bypass has been considered. In this study, the design criteria of the road and water tunnel has been analysed and the composite design criteria is proposed for the multi-functional tunnel which is expected to be constructed.

Method for Flood Runoff Analysis of Main Channel Connected with Interior Floodplain : I. Application for Analysis of Inundation Area in Interior Floodplain (제내지와 하도를 연계한 하천유역의 홍수유출해석: I. 제내지 침수해석에의 적용)

  • Jang, Su Hyung;Yoon, Jae Young;Yoon, Yong Nam;Kim, Won Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1B
    • /
    • pp.79-88
    • /
    • 2006
  • In this study, a methodology is developed for flood runoff analysis considering the interaction between interior floodplain and channel. Riparian lowland is modeled as storage areas by HEC-RAS and is connected with main channel through gravity drainage structure and pumping stations. As a result, we were able to compute the difference between runoff into the interior floodplain and delayed runoff to main channel from interior floodplain. This allowed us to compute the storage change in the interior floodplain and corresponding inundation areas. Furthermore, the levee is modeled as a lateral structure and the flood from the main channel to interior floodplain is modeled by installing a weir on top of it. In addition, levee breach is also modeled so that flooding from main channel to interior floodplain can be considered. Computed flooding depth in the storage areas are compared with elevation to identify the inundated areas and flood maps can then be produced for a desired time or for the extent of flooding given a flooding depth. Output from this modeling effort can provide many useful information for flood planning such as flow depth in main channel, flooding depth and area in interior floodplain. The method was applied to Sapgyo river basin and the comparison with observed flood events showed that it can reproduce the observation fairly well, hence proving the utility of the method.

Traffic Forecasting Model Selection of Artificial Neural Network Using Akaike's Information Criterion (AIC(AKaike's Information Criterion)을 이용한 교통량 예측 모형)

  • Kang, Weon-Eui;Baik, Nam-Cheol;Yoon, Hye-Kyung
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.7 s.78
    • /
    • pp.155-159
    • /
    • 2004
  • Recently, there are many trials about Artificial neural networks : ANNs structure and studying method of researches for forecasting traffic volume. ANNs have a powerful capabilities of recognizing pattern with a flexible non-linear model. However, ANNs have some overfitting problems in dealing with a lot of parameters because of its non-linear problems. This research deals with the application of a variety of model selection criterion for cancellation of the overfitting problems. Especially, this aims at analyzing which the selecting model cancels the overfitting problems and guarantees the transferability from time measure. Results in this study are as follow. First, the model which is selecting in sample does not guarantees the best capabilities of out-of-sample. So to speak, the best model in sample is no relationship with the capabilities of out-of-sample like many existing researches. Second, in stability of model selecting criterion, AIC3, AICC, BIC are available but AIC4 has a large variation comparing with the best model. In time-series analysis and forecasting, we need more quantitable data analysis and another time-series analysis because uncertainty of a model can have an effect on correlation between in-sample and out-of-sample.

The Role of Intra-Aortic Balloon Pump in Coronary Artery Bypass Surgery (관상동맥 우회술에서의 대동맥내 풍선 펌프의 역할)

  • 박성식;김기봉
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.282-286
    • /
    • 1997
  • In the era of coronary artery bypass grafting, the intraaortic balloon pump (IABP) is more widely used and its indication has been ex anded. We perf'orbed retrospective clinical analysis on the patients who have received IABP pre andfor postoperatively during the course of CABG. From January 1981 to June 1995, total 322 patients have received CABG at the Seoul National University Hospital and among them 50 patients (15.5%) were supported by IABP during the course of the operation. The mean age at the time. of the operation was 57.2 years (39∼ 75 years) and the male to female ratio was 33 : 17. The preoperative diagnosis was unstable angina in 33 (66%), stable angina in 7 (14%) and postinfarct angina in 8 patients(16%). As for the indications of the IABP, there were 13 cases(26%) with left main disease, 13 (26%) with class IV angina, 12 (24%) with difficulty in CPB weaning, 6 (12%) with postinfarct angina and 3 (6%) with severe LV dysfunction. In the remaining 3 cases, one patient was operated on after PTCA failure in emergency basis, another was a patient with AMI, and the other was one who had postoperative low c rdiac output syndrome. All IABPS were introduced via femoral artery and among them 45 cases (90%) percutaneously. The mean postoperative assist time was 22.3 hours (0.5 ∼ 168 hours) and IABP could be removed within 48 hours in most of them (44150). The operative mortality was 6.1% (3 cases) and postoperative morbidity was only one with lower extremity ischemia. The more general application of the IABP during the course of the CABG ,especially in patients with high preoperative risk factors or difficulty in CPB weaning is a good measure of protecting and recovering myocardial function with minimal risk.

  • PDF