• 제목/요약/키워드: pumping effect

검색결과 288건 처리시간 0.031초

전자냉동 김치독의 열유동 및 성능 특성 (Heat Flow and Cooling Performance of an Electronic Refrigerating Kimchi Jar)

  • 송규석;김경환;이승철;고철균;이재헌;오명도
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.928-936
    • /
    • 1999
  • The electronic refrigerating kimchi jar operates with a low noise because it contains no compressor but it consumes more energy than that of an refrigerator with compressor. In this paper, the heat flow characteristics and cooling performance of an electronic refrigerating kimchi jar are studied by means of experiments. When the storage temperature is kept in a range of $-5.7^{\circ}C$ to $4.1^{\circ}C$. in the case of three ambient temperatures; $12.7^{\circ}C$, $22.3^{\circ}C$ and $32.2^{\circ}C$, the cooling performance of $20{\ell}$ kimchi jar is investigated. The experiments show that the temperature difference that exists between kimchi jar and its ambient provides a measure of the coefficient of performance of kimchi jar. It is also found that ratio of net pumping heat to the heat pumping rate of thermoelectric module is independent of the temperature difference.

Investigation of Endurance Degradation in a CTF NOR Array Using Charge Pumping Methods

  • An, Ho-Myoung;Kim, Byungcheul
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권1호
    • /
    • pp.25-28
    • /
    • 2016
  • We investigate the effect of interface states on the endurance of a charge trap flash (CTF) NOR array using charge pumping methods. The endurance test was completed from one cell selected randomly from 128 bit cells, where the memory window value after 102 program/erase (P/E) cycles decreased slightly from 2.2 V to 1.7 V. However, the memory window closure abruptly accelerated after 103 P/E cycles or more (i.e. 0.97 V or 0.7 V) due to a degraded programming speed. On the other hand, the interface trap density (Nit) gradually increased from 3.13×1011 cm−2 for the initial state to 4×1012 cm−2 for 102 P/E cycles. Over 103 P/E cycles, the Nit increased dramatically from 5.51×1012 cm−2 for 103 P/E cycles to 5.79×1012 cm−2 for 104 P/E cycles due to tunnel oxide damages. These results show good correlation between the interface traps and endurance degradation of CTF devices in actual flash cell arrays.

Development of Minimally Invasive Mid-infrared Lipolysis Laser System for Effective Fat Reduction

  • Lee, Ji-Young;Ryu, Han Young;Seo, Young-Seok
    • Medical Lasers
    • /
    • 제10권2호
    • /
    • pp.82-89
    • /
    • 2021
  • Background and Objectives Due to changes in diet and lifestyle, the number of obese people worldwide is steadily increasing. Obesity has an adverse effect on a healthy life, so it needs treatment and improvement. Research related to this is continuously being conducted. Materials and Methods The laser system to compact designed using 808 nm laser diode and Neodymium Yttrium orthovanadate generates a 1064 nm wavelength, the periodically polarized nonlinear crystal pumping laser beam. The pulsed 1064 nm wavelength beam passing through the AO Q-switch is used as the pumping light of the nonlinear optical crystal and is irradiated to the periodic polarized nonlinear optical crystal with a quasi-phase matching period. Nonlinear optical crystals use an oven to control the temperature to generate the desired 1980 nm and 2300 nm wavelengths. Results The 1980 nm and 2300 nm wavelengths generated by temperature control of nonlinear optical crystals are effective for lipolysis. A fiber catheter was used so that the laser could be directly irradiated to the fat cells. In particular, the new wavelength (1980 nm, 2300 nm) can increase the fat reduction effect with low energy (1.3 W). When a laser with a combination wavelength of 1980 nm and 2300 nm was used, an average lipolysis effect of 20% was obtained. Conclusion A mid-infrared lipolysis laser system with excellent absorption of fat and water has been developed. We conducted a princlinical study to confirm the efficacy and safety of the lipolysis laser system, and obtained good results for lipolysis with low energy.

배수펌프장의 효율적인 운영을 위한 퍼지모형의 적용 (Application of the Fuzzy Models for the Efficient Operation of Pumping Station)

  • 김윤태;심재현;정재학;안재찬
    • 한국방재학회 논문집
    • /
    • 제4권3호
    • /
    • pp.51-60
    • /
    • 2004
  • 최근 도시지역의 수해요인은 내수침수불량에 기인하기 때문에 유수지 및 배수펌프장을 신설하여 유수지로 유입되는 유출량을 하천으로 강제배수하게 된다. 그러나 하수관거의 용량이 부족하여 유수지로 미처 유입되기 전에 하수관거의 역류로 침수피해가 자주 발생하고 있다. 따라서 본 연구에서는 도시 내배수 체계의 조사방법을 제시, 하수관거의 위험도를 평가하고 개선할 수 있는 방안을 제시하였다. 또한 배수펌프의 가동대수를 단순한 수위기준에서 변화시켜 실무에서 전문가가 아니더라도 사용할 수 있는 전산모형 8개를 개발하여 제시하였고, 지속기간, 설계빈도, 시간분포 등을 변화시켜 유수지 수위의 적정 조절여부를 검토하였다. 그리고 강제적인 배수에 의해 하류부의 수위영향이 예견되기 때문에 해당 유역의 수위를 안전하게 유지하면서도 하류부에 수위영향을 최소화할 수 있는 방안에 대해서도 검토하였다. 연구결과 Fuzzy 모형이 기존의 운영방법보다 더 효과적으로 유수지의 수위를 저하시킬 수 있었으며, 하류부 수위는 약 8cm 정도 감소시킬 수 있었다.

농촌지역의 질산성질소 거동 해석을 위한 모델 개발 및 현장 적용 (Model Development for Analysis of Nitrate Leaching and Its Field Application in a Rural Area)

  • 석희준;전철민
    • 자원환경지질
    • /
    • 제42권6호
    • /
    • pp.561-574
    • /
    • 2009
  • 본 연구에서는 농업지역에서의 양수, 관개, 탈질작용을 고려한 불포화대 및 포화대 지하수 흐름 및 용질이동 모델인 VSFRT2D(Variably Saturated Flow and Reactive Transport model)를 개발하였다. VSFRT2D는 Richards equation을 지하수 흐름 지배방정식으로 이용하며, Thornthwaite 방법을 이용하여 강수가 일어나지 않을 때 지표면 증발산량 계산 절차를 포함하는 새로운 모델을 개발함으로써 기존의 불포화대 모델을 개선하였다. 또한 Monod kinetics에 기반한 생분해 기작을 네 개의 비선형 오염물 거동식과 세 종류의 미생물 거동식을 이용함으로서 탈질작용을 이 모델에 반영하였다. 개발된 모델을 질산성질소로 오염된 홍성 지역의 현장 관측 자료에 적용하였다. 본 연구에서는 강수, 양수, 증발산, 관개, 비료 투여 및 다양한 생분해 과정들이 지하수 흐름 및 오염물 거동에 미치는 효과들을 확인하기 위하여 각각의 과정을 개별적으로 나누어서 수치 모의한 후 각각의 결과를 상호 비교하였다. 수치 모의 결과 이 지역에서의 질산성 질소 농도 변화는 생분해에 의한 영향은 매우 미미하게 나타났다. 반면에 관개에 의한 양수, 강수, 질소 비료 시비에 의해서는 크게 영향을 받았다.

볼기근 근력강화 운동과 병행한 발목관절 펌핑 운동이 엉덩관절 전치환술 환자의 허벅지 둘레, 보행능력, 통증 수준에 미치는 영향 (Effect of Adding Ankle-Joint-Pumping Exercise to Gluteal-Muscle-Strengthening Exercise on Thigh Swelling, Gait ability and Pain level in Patients With Total Hip Arthroplasty )

  • 이현국;김선엽
    • 대한물리의학회지
    • /
    • 제19권2호
    • /
    • pp.17-28
    • /
    • 2024
  • PURPOSE: This study was conducted to investigate the effect of gluteal muscle strengthening exercises (GMSE) with ankle joint pumping exercises (AJPE) on thigh swelling, gait ability, and pain level in patients who underwent total hip arthroplasty. METHODS: A total of 38 patients who had undergone total hip replacement surgery >1 week prior participated in this study. Participants were randomly assigned to a group that performed only GMSE (CG; n = 19) and a group that performed GMSE and AJPE (EG; n = 19). The CG group performed GMSE for 30 min, and the EG group performed GMSE for 30 min followed by AJPE for 15 min. Exercises were performed five times a week, for a total of 20 times over 4 weeks in both groups. Thigh swelling (thigh size), 10 m walking test (10MWT) and timed up and go test (TUG) results, pain level (visual analogue scale, VAS) scores, Short Form 36 health survey (SF-36), and hip outcome scale (HOS) scores were evaluated before and after the intervention. RESULTS: After 4 weeks of intervention, significant differences were observed in the thigh size, 10MWT, TUG, VAS, SF-36, HOS before and after intervention in both groups (p < . 05). However, only thigh size showed a significant interaction between group and measurement time (p < . 05). CONCLUSION: GMSE combined with AJPE might be effective in improving the gait ability and pain level in patients with total hip arthroplasty, and GMSE may be more effective in improving thigh swelling and gait ability than GMSE without AJPE.

단기통 4사이클 스파아크 점화기관 흡.배기 과정의 시뮬레이션 (Simulation of the gas exchange process for single-cylinder 4-stroke cycle spark ignition engine)

  • 윤건식;유병철
    • 오토저널
    • /
    • 제7권1호
    • /
    • pp.24-34
    • /
    • 1985
  • The study of unsteady gas exchange processes in the inlet and exhaust systems of the single-cylinder 4-stroke cycle spark ignition engine is presented in this paper. The generalized method of characteristics including friction, heat transfer, change of flow area and entropy gradients was used for solving the equations defining the gas exchange process. The path line calculation was also conducted to allow for calculation of the gas composition and entropy change along the path lines, and of the variable specific heat due to the change of temperature and composition. As the result of the simulation, the properties at each point in the inlet and exhaust pipe, pressure and temperature in the cylinder, and charging efficiency were obtained. Pumping loss and residual gas fraction were also computed. The effect of engine speed, exhaust and inlet pipe length on the pumping loss and charging efficiency were studied showing that the results were in agreement with what has been known from experiments.

  • PDF

수직격판이 있는 용기 내의 지균류 (Geostrophic Flows in a Container with a Vertical Plate)

  • 최윤환;서용권
    • 한국해양공학회지
    • /
    • 제13권4호통권35호
    • /
    • pp.124-131
    • /
    • 1999
  • In this paper, we show the numerical and experimental results of two-dimensional fluid motions inside a rectangular container with a vertical plate subjected to a background rotation added by a rotational oscillation. In the PIV experiment we apply a new algorithm, NTSS, to the velocity calculation. In the numerical computation, the linear Ekman-pumping model was used to take the bottom friction effect into account. It was found that it showed good agreement with the experimental results at low ${\epsilon}$ number.

  • PDF

PIV를 이용한 바탕회전하에서 회전요동하는 직사각형 용기 내의 유동해석 (Study on Fluid Flow in a Rectangular Container Subjected to a Background Rotation with a Rotational Oscillation Using PIV System)

  • 서용권;최윤환;김성균;이두열
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.845-851
    • /
    • 2000
  • In this paper, we show the numerical and the experimental results of two-dimensional fluid motions inside a rectangular container subjected to a background rotation added by a rotational oscillation. In the PlY experiment we apply a new algorithm, new three step search(NTSS), to the velocity calculation. In the numerical computation, the linear Ekman-pumping model was used to take the bottom friction effect into account. It was found that it well produces the experimental results at low e number.

Simulation for the effect of vertical groundwater flux on the subsurface temperature distribution

  • 신지연;이강근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2006년도 총회 및 춘계학술발표회
    • /
    • pp.383-386
    • /
    • 2006
  • Subsurface temperature is affected by heat advection due to groundwater advection. Temperature-depth profile can be perturbed especially when there are significant vertical groundwater flux caused by external force such as injection or extraction. This research is to clarify the change of subsurface temperature distribution when the 40m x l0m sandy aquifer is stimulated by two different vertical flux($case1:\;{\pm}10^{-5}m^3/s,\;case2:\;{\pm}4{\times}10^{-5}m^3/s$) using a program called HydroGeoSphere. The resulting temperature distribution contour map shows pumping causes vertical attraction of water from deeper and warmer place which result in rising up isotherm. Additionally more injection/extraction rate, more vertical groundwater flux leads to faster Increase in temperature near the pumping well.

  • PDF