• Title/Summary/Keyword: pulsed Nd : YAG laser

Search Result 276, Processing Time 0.026 seconds

Stabilization of Output Pulses from a Passively Q-switched Nd:YVO4 Laser Pumped by a Continuous-wave Laser Diode (연속 발진 다이오드 레이저로 여기된 수동형 Q-스위치 Nd:YVO4 레이저의 출력 펄스 안정화)

  • Ahn, Seung-In;Park, Yune-Bae;Yeo, Hwan-Seop;Lee, Joon-Ho;Lee, Kang-In;Yi, Jong-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.276-280
    • /
    • 2009
  • A Cr:YAG crystal was used as a saturable absorber for passive Q-switching of a Nd:$YVO_4$ laser which was pumped by a 1-W continuous wave laser diode. The first surface of the Cr:YAG was high-reflection coated for the pump wavelength. The high-reflection coating improved the absorption efficiency of the pump beam in the Nd:$YVO_4$ through double pass absorption. It also prevented pump beam induced partial bleaching of the Cr:YAG. The peak-to-peak pulse fluctuation of passively Q-switched laser output was approximately 4 %. The minimum pulse-width was measured to be 7.11 ns. Also, the average pulse repetition rate was 9 kHz and the maximum output power was 16.27 mW.

A Study on configuration of a laser resonator with high alignment stability (높은 정렬 안정성을 갖는 레이저 공진기 구성에 관한 연구)

  • 차혁진
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.279-288
    • /
    • 2000
  • The variations of output energy due to tilt output coupler for different types of pulsed Nd:YAG laser resonators were compared by measuring FWHM (full width at half maximum) which means the width of angle displacement where maximum output energy decreases to half value. We proposed a new configuration of pulsed solid-state laser resonator which had high FWHM for tilting of output coupler and which was little sensitive for tilting of rear optics. We proved that our laser resonator had high alignment stability using ABeD ray matrix method because the ray matrix of such a resonator corresponded to unit matrix. atrix.

  • PDF

Optimal operating characteristics of single-elliptical Nd:YAG laser (단일타원 펄스형 Nd:YAG 레이저의 최적동작에 관한 연구)

  • Kwak, Byung-Goo;Kim, Dong-Hyun;Jung, Jong-Han;Cho, Jung-Soo;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1756-1758
    • /
    • 1996
  • In order to optimize the operational characteristics of single elliptical pulsed Nd:YAG laser designed and fabricator compactly, it is very important to design the resonator shape and the PFN(Pulse Forming Network) suitably. We have been shown that the EMTP(Electro-Magnetic Transient Program) simulation. was used effectively in designing PFN. And Next, we have been compared current pulse width, laser beam profile and damping parameter with laser output energy. In this paper, we have suggested the optimalization of PFN design and the best operational condition.

  • PDF

Fatigue Properties of Ti-Ni Shape Memory Alloy Wire Welded by Nd: YAG Laser

  • Kim, Y.S.;Kim, J.D.;Kil, B.L.
    • International Journal of Korean Welding Society
    • /
    • v.3 no.1
    • /
    • pp.39-44
    • /
    • 2003
  • The welded specimens were made by butt welding of the 2 wires of 50mm length using the pulsed YAG laser. The laser welded wires were tested for investigating the shape memory effect and the ability of super elasticity. The fatigue properties of the welded wires were investigated using the rotary bending fatigue tester specially designed for wires. Moreover, the effect of defocusing distance during laser welding on the static and fatigue properties was Investigated. The shape memory effect and super elasticity of the laser welded wires were approximately identical with that of base metal at the test temperature below 353K. However, the welded wires were broken within elastic limit at the test temperature above 353k. Under the cyclic bending loading conditions, the welded wires could be useful only below the elastic limit, while the base metal had sufficient fatigue life even the stress induced M-phase region. The fatigue strength of the welded wires was about half of that of the base metal. The deterioration of the static and fatigue properties in the welded wires was proven to be from the large difference of the transformation behavior between the base metal and welded part that is caused by vaporization of Ni-content at the welded part during the welding process. The defocusing distance below 3mm acted more largely on lowering the strength of the welded wires than that of 6mm or 8mm.

  • PDF

C-Ring Stress Corrosion Test for Inconel 600 Tube and Inconel 690 welded by Nd:YAG Laser (Nd:YAG 레이저로 용접한 인코넬 600관과 인코넬 690의 C링 응력 부식시험)

  • 김재도;문주홍;정진만;김철중
    • Proceedings of the KWS Conference
    • /
    • 1998.10a
    • /
    • pp.288-291
    • /
    • 1998
  • Inconel 600 alloy is used as the material of nuclear steam generator tubing because of its mechanical properties, formability, and corrosion properties. According to reports, the life time of nuclear power plants decreases because of the pitting, intergranular attack, primary water stress corrosion cracking(PWSCC), and intergranular stress corrosion cracking(IGSCC), and denting in the steam generator. The SCC test is very important because of SCC appears in various environment such as solutions, materials, and stress. The C-Rig specimen was made of the steam generator welded sleeve repairing by the pulsed Nd:YAG laser. In the corrosion invironment, corrosion solutions are Primary Water, Caustic, and Sulfate solution and corrosion time is 1624-4877hr. The permitted stress is 30-60ksi.In this C-Ring SCC test is the relationship between corrosion depth, crack and corrosion environment is evaluated. SCC was happens in Sulfate and Corrosion solution but doesn't happen in Primary Water. The corrosion time and stress is very affected by the severely environment of Sulfate or Caustic solution. The microstructure observation indicates that SCC causes interganular failure in the grain boundary of vertical direction.

  • PDF

A STUDY ON WELD POOL MONITORING IN PULSED LASER EDGE WELDING

  • Lee, Seung-Key;Na, Suck-Joo
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.595-599
    • /
    • 2002
  • Edge welding of thin sheets is very difficult because of the fit-up problem and small weld area In laser welding, joint fit-up and penetration are critical for sound weld quality, which can be monitored by appropriate methods. Among the various monitoring systems, visual monitoring method is attractive because various kinds of weld pool information can be extracted directly. In this study, a vision sensor was adopted for the weld pool monitoring in pulsed Nd:YAG laser edge welding to monitor whether the penetration is enough and the joint fit-up is within the requirement. Pulsed Nd:YAG laser provides a series of periodic laser pulses, while the shape and brightness of the weld pool change temporally even in one pulse duration. The shutter-triggered and non-interlaced CCD camera was used to acquire a temporally changed weld pool image at the moment representing the weld status well. The information for quality monitoring can be extracted from the monitored weld pool image by an image processing algorithm. Weld pool image contains not only the information about the joint fit-up, but the penetration. The information about the joint fit-up can be extracted from the weld pool shape, and that about a penetration from the brightness. Weld pool parameters that represent the characteristics of the weld pool were selected based on the geometrical appearance and brightness profile. In order to achieve accurate prediction of the weld penetration, which is nonlinear model, neural network with the selected weld pool parameters was applied.

  • PDF

Effect of Pulse Shapes on Weld Defects in Pulsed Laser Welding of Stainless Steel

  • Kim, Jong-Do;Kil, Byung-Lea;Kim, Young-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1270-1278
    • /
    • 2004
  • This paper describes the effectiveness of laser pulse shaping in eliminating weld defects such as porosity, cracks and undercuts in pulsed Nd:YAG laser welding. A large porosity was formed in a keyhole mode of deeply penetrated weld metal of any stainless steel. Solidification cracks were present in STS 310S with above 0.017%P and undercuts were formed in STS 303 with about 0.3%S. The conditions for the formation of porosity were determined in further detail in STS 316. With the objectives of obtaining a fundamental knowledge of formation and prevention of weld defects, the fusion and solidification behavior of a molten puddle was observed during laser spot welding of STS 310S through a high speed video photographing technique. It was deduced that cellular dendrite tips grew rapidly from the bottom to the surface, and consequently residual liquid remained at the grain boundaries in wide regions and enhanced the solidification cracking susceptibility. Several laser pulse shapes were investigated and optimum pulse shapes were proposed for the reduction and prevention of porosity and solidification cracking.

A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Cervical Cementum (Nd:YAG 레이저조사가 치경부 백악질에 미치는 영향에 관한 주사전자현미경적 연구)

  • Choi, Bok;Lee, Jeong-Yeon;Shin, Keum-back
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.4
    • /
    • pp.415-425
    • /
    • 2000
  • In order to obtain the basic data concerning the optimal lasing conditions in using Nd:YAG laser as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum, the author selected 36 human teeth having no cervical abrasion and caries (; 12 anteriors, 12 premolars. 12 molars) extracted due to periodontal diseases, and divided them into 4 groups as Group I, II, III and IV (; each group of 3 anteriors, 3 premolars, 3 molars), and prepared a cementum specimen with thickness of $1.0mm{\pm}0.2mm$ sectioned longitudinally at the middle of mesio-distal thickness (; Group I) or horizontally at 1mm-2mm below the cemento-enamel junction (; Group II, III, IV) from each tooth of each group by low speed diamond wheel saw, and treated them with 0.5 M ethylene diamine tetraacetic acid (; EDTA, pH=7.4) for 2 minutes for elimination of remnants during tooth-sectioning. And the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (; wavelength 1064nm. pulse duration $120{\mu}sec$, fiber diameter $320{{\mu}m}$) to cementum surfaces in triplicates of one experiment under the following lasing conditions: 1. stationary mode of fiber in contact to cementum surfaces without air-spray (; Group I )/with air-spray (; Group II), 2. unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec without air-spray (; Group III)/with air-spray (; Group IV), 3. energy per pulse (mJ/pulse) [; energy density ($J/cm^{2}$)] in order of 1.0W/10Hz (100J/pulse); $124J/cm^{2}$, 0.5W/10Hz (50mJ/pulse); $62J/cm^{2}$, 0.4W/10Hz (40mJ/pulse); $50J/cm^{2}$, 0.3W/10Hz (30mJ/pulse); $37J/cm^{2}$, 4. exposure time of 1 second. And the author applied the platinum coating on surfaces of cementum specimens, and evaluated the characteristics of ultrastructural change on surfaces of cementum using the scanning electron microscopy. In general the ultrastructural loss of cervical cementum irradiated under the same lasing condition of laser energy density occurred least in specimens of Group IV. And especially, the ultrastructural loss of cervical cementum irradiated under the laser energy density of $37J/cm^{2}$ almost did not occur in specimens of Group IV. Therefore, it is considered that the pulsed Nd:YAG laser should be applied with the lasing conditions of unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec with air-spray and of laser energy density within $37J/cm^{2}$ as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum.

  • PDF

Weldability of Pure Titanium Thin plate for LPG Re-Condenser by Nd:YAG Laser - Physical Constant and Welding Parameter - (LPG 재응축기용 순티타늄 박판의 Nd:YAG 레이저 용접성(I) - 순티타늄의 물성과 용접변수 -)

  • Kim, Jong-Do;Gwak, Myeong-Seop;Lee, Chang-Je;Kim, Chang-Su
    • Proceedings of the KWS Conference
    • /
    • 2007.11a
    • /
    • pp.363-365
    • /
    • 2007
  • Titanium and its alloys have excellent corrosion resistance, high strength to weight ratios and high temperature creep properties, which make them using many various fields of application. Responding to these needs, welding processes for titanium are also being used including TIG, MIG, resistance welding, plasma arc welding, diffusion welding, electron beam welding and laser welding. In this study, It is possible to get sound beads without humping bead and spatter with the decrease of peak power according to increase of pulse width and change of welding speed for heat input control at pulsed Nd:YAG laser welding of titanium plates for Lap welding.

  • PDF

The Spatial Coherence Characteristics of Wavefront of NBUR Nd:YAG Laser Output Beam (NBUR Nd:YAG 레이저 위상파면의 공간적 가간섭성 특성)

  • 박대윤;최승호;이승걸
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.288-295
    • /
    • 1995
  • We have studied about spatial wavefront analysis of a pulsed laser output beam by means of an imaging unstable ring resonator with an infinite Fresnel number. We have constructed a Newtonian telescope type NBUR (Negative Branch Unstable Ring) Nd:YAG laser with 4 plane mirrors. Provided that the NBUR resonator is under self imaging condition, the resonator could be reduced diffraction effects which were occuring to the beam transmitting through the circular aperture of scraper mirror in the resonator. We have observed enhancement in the spatial coherence of wavefronts of laser beam due to the iterative round trips of the self imaging beam inside the ring resonator. The information on the spatial wavefronts was determined by the fringe patterns from Mach-Zehnder interferometer and the fringe analysis by means of the Fourier transform method showed the distortion of wavefronts of less than 0.2), In comparison with a standing wave type resonator, we have confirmed that the spatial coherence of the NBUR Nd:YAG laser output beam was enhanced as much as 75%. s 75%.

  • PDF