• 제목/요약/키워드: pulse-energy

검색결과 1,308건 처리시간 0.026초

Nd:YAG 레이저조사가 치경부 백악질에 미치는 영향에 관한 주사전자현미경적 연구 (A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Cervical Cementum)

  • 최복;이정연;신금백
    • Journal of Oral Medicine and Pain
    • /
    • 제25권4호
    • /
    • pp.415-425
    • /
    • 2000
  • In order to obtain the basic data concerning the optimal lasing conditions in using Nd:YAG laser as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum, the author selected 36 human teeth having no cervical abrasion and caries (; 12 anteriors, 12 premolars. 12 molars) extracted due to periodontal diseases, and divided them into 4 groups as Group I, II, III and IV (; each group of 3 anteriors, 3 premolars, 3 molars), and prepared a cementum specimen with thickness of $1.0mm{\pm}0.2mm$ sectioned longitudinally at the middle of mesio-distal thickness (; Group I) or horizontally at 1mm-2mm below the cemento-enamel junction (; Group II, III, IV) from each tooth of each group by low speed diamond wheel saw, and treated them with 0.5 M ethylene diamine tetraacetic acid (; EDTA, pH=7.4) for 2 minutes for elimination of remnants during tooth-sectioning. And the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (; wavelength 1064nm. pulse duration $120{\mu}sec$, fiber diameter $320{{\mu}m}$) to cementum surfaces in triplicates of one experiment under the following lasing conditions: 1. stationary mode of fiber in contact to cementum surfaces without air-spray (; Group I )/with air-spray (; Group II), 2. unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec without air-spray (; Group III)/with air-spray (; Group IV), 3. energy per pulse (mJ/pulse) [; energy density ($J/cm^{2}$)] in order of 1.0W/10Hz (100J/pulse); $124J/cm^{2}$, 0.5W/10Hz (50mJ/pulse); $62J/cm^{2}$, 0.4W/10Hz (40mJ/pulse); $50J/cm^{2}$, 0.3W/10Hz (30mJ/pulse); $37J/cm^{2}$, 4. exposure time of 1 second. And the author applied the platinum coating on surfaces of cementum specimens, and evaluated the characteristics of ultrastructural change on surfaces of cementum using the scanning electron microscopy. In general the ultrastructural loss of cervical cementum irradiated under the same lasing condition of laser energy density occurred least in specimens of Group IV. And especially, the ultrastructural loss of cervical cementum irradiated under the laser energy density of $37J/cm^{2}$ almost did not occur in specimens of Group IV. Therefore, it is considered that the pulsed Nd:YAG laser should be applied with the lasing conditions of unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec with air-spray and of laser energy density within $37J/cm^{2}$ as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum.

  • PDF

펨토초 레이저가 조사되는 동안의 금속 박막내의 비평형 에너지 전달 현상에 대한 수치해석 연구 (Numerical Investigation on Nonequilibrium Energy Transfer in Thin Metal Film Structures during the Irradiation of Femtosecond Pulse Laser)

  • 심형섭;이성혁
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.367-373
    • /
    • 2007
  • The present study investigates numerically nonequilibrium energy transfer between electrons and phonons in metal thin films irradiated by ultrashort pulse lasers and it also provides the temporal and spatial variations of electron and phonon temperatures using the well-established two-temperature model(TTM) on the basis of the Boltzmann transport equation(BTE). This article predicts the crater shapes in gold film structures, and compares the results by using two-dimensional energy transport equation. From the results, it is found that nonequilibrium energy transfer between electrons and phonons takes place, and the equilibrium time increases with the increase of laser fluence. On the other hand, above threshold fluence the ablation time doesn't change nearly with increasing fluences. Compared with one-dimensional TTM, it also reveals that the temporal distributions of electron and phonon temperatures at the top surface estimated by using two-dimensional TTM have a similar tendency. The results show that two-dimensional TTM can simulate the crater shape of metals during the irradiation of femtosecond pulse lasers and the absorbed energy is propagated to z-direction faster than to r-direction.

Golay 코드를 사용한 초음파펄스압축법 개발 (Development of Ultrasonic Pulse Compression Using Golay Codes)

  • 김영환;김영길
    • 비파괴검사학회지
    • /
    • 제14권3호
    • /
    • pp.185-193
    • /
    • 1994
  • 범용의 초음파탐상장치에서는 탐촉자를 구동하기 위하여 높은 전압의 좁은 펄스를 사용하는데, 이 펄스의 평균 출력에는 제한이 따른다. 과도하게 높은 전압은 탐촉자를 파괴시키고, 지나치게 긴 펄스는 분해능을 감소시킨다. 긴 폭의 의사렌덤신호를 사용한 펄스압축은 상호관계를 이용하여 분해능을 감소시키지 않고 신호대 잡음비를 개선할 수 있다. 본 연구에서는 Golay 코드를 사용한 초음파펄스압축법을 개발하였다. 이론적으로 펄스압축에서의 신호 특성 및 신호대 잡음비를 계산하기 위하여 Golay 코드의 등 가임펄스를 제안하였고, 이를 실험적으로 증명해 보였다. 렌덤한 잡음신호에 대하여 S/N 비가 Golay 코드의 제곱근에 비례하였고, 이 방법은 고분자, 플래스틱, 고무와 같은 흡수가 큰 재료에서 유용함을 알 수 있었다.

  • PDF

빔 중첩율에 따른 티타늄 합금의 펨토초 레이저 어블레이션 (The Femto Second Laser Induced Ablation on the Titanium Alloy for Various Beam Overlap Ratio)

  • 정일영;강경호;김재도
    • 한국정밀공학회지
    • /
    • 제27권11호
    • /
    • pp.17-23
    • /
    • 2010
  • Titanium alloy is one of the hard processing materials made by the traditional manufacturing method because of the excellent mechanical strength. Ablation of titanium alloy is investigated by using a femtosecond laser which is a regenerative amplified Ti:sapphire laser with 1kHz repetition rate, 184fs pulse duration time and 785nm wavelength. Experiments are carried out under various ablation conditions with different pulse overlap ratios for the rectangular shape and micro hole. Test results show that the ablation characteristic according to pulse overlap ratio of titanium alloy seems to be as non-linear type at the different zone of energy fluence. The optimal condition of rectangular shape processing is obtained at the laser peak power 1.3mW, pulse overlap ratio of 90%, beam gap of $1\;{\mu}m$. The micro hole has a good quality from the pulse overlap ratio of 99% at the same laser peak power. With the optimal processing condition, the fine rectangular shape and micro hole without burr and thermal damage are achieved.

이중펄스 로켓모타의 격막형 펄스분리장치 설계 및 성능평가 (The Design & Analysis of Pulse Separation Device with Thermal Barrier Type for Dual Pulse Rocket Motor)

  • 김진용;권태하;이원복;조원만;이방업;정규동;이영우
    • 한국군사과학기술학회지
    • /
    • 제18권1호
    • /
    • pp.93-99
    • /
    • 2015
  • The dual pulse rocket motor(DPRM) distributes the propellant energy effectively via pulse separation device(PSD) to improve the range and terminal velocity of the missile. There are two types of PSD such as bulk head type and thermal barrier type. A subscale thermal barrier type DPRM was designed, manufactured, and tested. The results showed good understanding of the characteristics of the PSD and will be applied to the design of the full scale DPRM.

펄스방전을 이용한 미생물제거 및 금속산화물 제거특성에 관한 연구 (A Study on the Removal Characteristics of microbe and metal-oxide using pulse discharging)

  • 정종한;김수원;김휘영;이유수;전진안;정현주;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1818-1820
    • /
    • 2003
  • In this study, we developed friendly-environment device through various applications of pulse power system and studied research about pulse energy transfer characteristics. We have studied the mutual relation between characteristics of the load impedance and consumed power of the pulse power system. The consumed power means electrical power from the wall plug. For changing the load impedance, we could change elecrode length. As results, we can get electrical characteristics between pulse generator and load. When the pulse energy was triggered the microbes, caused waste water, they were almost removed in the waste water.

  • PDF

DC/DC 전력 컨버터의 전류모드 PWM 제어기의 방사선 영향 (Effects of the Irradiated Current Mode PWM Controller of DC/DC Power Converter)

  • 노영환;황의성;노경수;푸파논;캄푸는;한창운
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.685-692
    • /
    • 2011
  • DC/DC switching power converters produce DC output voltages from different DC input sources. The converters can be used in regenerative braking of DC motors to return energy back in the supply, resulting in energy savings for the systems containing frequent stops. The current mode DC/DC converter is composed of a PWM (pulse width modulation) controller, a MOSFET, and inductor, etc. Pulse width modulation is applied to control and regulate the total output voltage. It is shown that the variation of threshold voltage at MOSFET and the offset voltage increase caused by radiation effects make the PWM pulse unstable. In the PWM operation, the missing pulses, the changes in pulse width, and a change in the period of the output waveform are studied by simulation program with integrated circuit emphasis (SPICE) and experiments.

  • PDF

플래시 램프로 펌핑한 Nd:YAG 레이저의 $1.444{\mu}m$ 출력 특성 (Output Characteristics of a Flashlamp pumped Nd:YAG Lasers at 1.444 nm)

  • 이희철;김규욱;김동현;공승환;김용평
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권12호
    • /
    • pp.606-610
    • /
    • 2006
  • We investigated the output characteristics of Nd:YAG lasers at wavelength of 1444 nm, which were pumped by 450 Xe-flashlamp, 700 torr Xe-flashlamp and 700 torr Kr-flashlamp. With a Xe-flashlamp of 700 torr of gas pressure, the pulse energy of 0.738 J was obtained with repetition rate of 9.16 Hz and pumping pulse width of 400 ms. In case pumping pulse width of 5 ms and repetition rate of 1 Hz, 700 torr Kr-flashlamp showed the highest pulse energy of 1.44 J.

A scintillation detector configuration for pulse shape analysis

  • Van Chuan, Phan;Hoa, Nguyen Duc;Hai, Nguyen Xuan;Anh, Nguyen Ngoc;Dien, Nguyen Nhi;Khang, Pham Dinh
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1426-1432
    • /
    • 2018
  • This paper presents a neutron detector configuration using EJ-301 scintillation liquid, a R9420 photo-multiplier and a homemade preamplifier. The detector qualities which include the energy linearity, efficiency response and neutron/gamma discrimination are guaranteed for neutron detection in the energy range from 0 to 3000 keVee. Regarding the neutron/gamma discrimination capability, four pulse shape discrimination (PSD) methods which are the threshold crossing time (TCT), pulse gradient analysis (PGA), charge comparison (CC) and correlation pattern recognition (CPR), were evaluated and discussed; among of these, the CPR method provides the best neutron/gamma discrimination.

HARD X-RAY PULSATIONS IN GX 1+4

  • AGRAWAL P. C.;PAUL B.;RAO A. R.;CHANDA R. K. MAN
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.219-221
    • /
    • 1996
  • The x-ray pulsar GX 1+4 was observed by us in four balloon- borne experiments carried out from Hyderabad, India during 1991-1995 period with a hard x-ray telescope. The x-ray telescope consists of two collimated large area xenon-filled proportional counters with an effective area of $2400 cm^2$, a field of view of $5^{\circ}{\times}5^{\circ}$ and sensitive in the energy band of 20 - 100 keV. The pulsar was detected in bright state in two of the four experiments and x-ray pulsations with 120 second period were detected clearly. Pulsation period, rate of change of period with time, pulse fraction, pulse profile and energy spectra of the source were determined from these studies. During March 1995 observation, the x-ray pulse of GX 1+4 was found to be double-peaked compared to a single-peak pulse profile detected in December 1993. Details of these results are presented and their interpretation discussed in terms of the current accretion models of x-ray binaries.

  • PDF