• Title/Summary/Keyword: pulse waveforms

Search Result 164, Processing Time 0.024 seconds

Measurement of High Voltage and Large Current Pulse Using Laser System (레이저를 이용한 펄스형 고전압 및 대전류 측정)

  • Lee, Yoon-Seok;Chang, Yong-Moo;Kim, Jung-Tae;Koo, Ja-Yoon;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.314-317
    • /
    • 1991
  • The waveforms of high voltage and current pulse were measured using laser measuring systems. Existing potential transformer and current transformer have low measuring precision because of resonance phenomena and waveform distortion due to the magnetic saturation. But using laser measurement, it is possible to obtain clear waveforms which have no effect of distortion and harmonic resonances. And electromagnetic interferences (EMI) in the measuring of high voltage and current pulse, but the optical measuring systems are not subjet to the influence of EMI. Using laser measuring systems based upon Pockels effect and Faraday effect is not free from any errors yet, but it could replace existing measuring systems by routine experiments and error corrections. And it needs that more research and development of optical crystals and equipments would be taken.

  • PDF

Interference Analysis Among Waveforms and Modulation Methods of Concurrently Operated Pulse Doppler Radars (단일 플랫폼에서 동시 운용되는 펄스 도플러 레이다의 파형 및 변조 방식간의 간섭 분석)

  • Kim, Eun Hee;Ryu, Seong Hyun;Kim, Han Saeng;Lee, Ki Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.23-29
    • /
    • 2022
  • As the application field of radar is expanded and the bandwidth increases, the number of radar sensors operating at the same frequency is continuously increasing. In this paper, we propose a method of analyzing interference when two pulse doppler radars are operated at the same frequency with different waveform which are designed independently. In addition, we show that even for a previously designed LFM waveforms, the interference can be suppressed without affecting the performance by changing the sign of the frequency slope by increasing/decreasing, or by modulating the pulses by the different codes. The interference suppression by different slopes is more effective for similar waveform and the suppression by the codes increases as the number of pulses increases. We expect this result can be extended to the cases where multiple radars are operated at the same frequency.

A Study on the SCR Frequency Converter With a Rotating Distributor (회전접촉자를 사용한 SCR 주파수 변환기에 관한 연구)

  • Chung Yon Tack
    • 전기의세계
    • /
    • v.24 no.1
    • /
    • pp.43-53
    • /
    • 1975
  • This paper describes a converter, which combines SCR bridge type rectifier circuit with a rotating distributor. This type of converter produces an adjustable low frequency output of three phase or single phase, from three phase or single phase power source. Output-waveforms of this converter are multi-pulse in three phase output, and square wave in single phase output. Problems about the operation of static switches, a commutation and output-waveforms are investigated, and experimental results verify that frequency can be adjusted satisfactorily from zero to 20 (Hz) and the expected output-waveforms are obtained without sparking on the distributor under various loading conditions. This converter can be utilized to low speed control of A.C. motors, and other lowfrequency loads.

  • PDF

QRS detection based on maximum a-posteriori estimation (MAP Estimation을 이용한 QRS Detection)

  • 정희교;신건수;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.709-712
    • /
    • 1987
  • In this paper, a mathematical model for the purpose of QRS detection is considered in the case of the occurrence of nonoverlapping pulse-shaped waveforms corrupted with white noise. The number of waveforms, the arrival times, amplitudes, and widths of QRS complexes are regarded as random variables. The joint MAP estimation of all the unknown quantities consists of linear filtering followed by an optimization procedure. Because of time-consuming, the optimization procedure is modified so that a threshold test is obtained. The model formulation with nonoverlapping waveforms leads to a standard procedure covering a segment before as well as after an accepted event. Adaptivity of the detector is gained by utilizing past signal properties in determining threshold for QRS detection.

  • PDF

A Multipulse-Voltage Source Rectifier System with a Three-Phase Diode Circuit in order to improve the Input Current Waveforms (입력 전류 파형 개선을 위한 다펄스 3상 다이오드 전압원 정류 시스템)

  • Im, Seong-Goun;Park, Hyun-Chul;Lee, Seong-Ryong;Yu, Chul-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.853-855
    • /
    • 1993
  • In this paper, a further improved system obtaining very low distorted waveforms of input ac currents of three phase rectifier circuit is proposed. The proposed system consists of an uncomplicated 24 pulse diode bridge rectifier that is transformerless, by adding only switching circuit which consists of two switchs to conventional system. Also to optimum the effectiveness or the harmonic reduction, the optimum turn ratio of an autotransformer and the optimum switching control angle are decided by computer simulation. And then, the voltage waveform obtained has a total harmonic distortion of 8.1%, and the predominant harmonics 23th and 25th. This paper describes operation principle, analysis of the waveforms of input voltage and current. The theoretial results are verified through simulation.

  • PDF

The new reset pulse used negative ramp slope for improving the addressing characteristic in ac PDP (ac PDP에서 Addressing 특성개선을 위한 Negative Ramp Slope이 적용된 Reset Pulse에 관한 연구)

  • Choi, Hye-Rim;Jung, Sun-Wook;Kang, Jung-Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.2 s.15
    • /
    • pp.11-14
    • /
    • 2006
  • A new reset waveform with negative ramp pulse is proposed. Conventional reset waveform applied to the commercial PDP uses a positive ramp pulse. The reset waveforms, especially focused on ramp area, were examined with 2 dimensional fluid code. The proposed negative reset waveform showed much lower ignition voltage ($\sim$70V) as compared with the conventional reset waveform. When the negative ramp pulse was applied, all of the positive-charged ions are collected on the scan electrode. It is found that the ignition voltage of reset discharge due to the negative ramp pulse became lower than that of positive ramp discharge.

  • PDF

A Study on the Auto-diagnosis Plethysmograph by Novel Algorithm for Radial Pulse Detection (새로운 맥파 인식 알고리즘을 적용한 자동 맥파 시스템에 관한 연구)

  • 박승환;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.241-246
    • /
    • 1996
  • This paper describes a new system that detects radial pulse wave and allows the diagnosis of malfunctions of cardiovascular system by analyzing the waveforms with the newly proposed algorithm. The system consists of a sensor part and a data processing part within which a new detection algorithm is incorporated In acquiring radial pulse signal noninvasively, the sensor used in this system is a new combinational fiber-optic sensor which has a detecting Part and a transmitting Part. Also, In order to analyze the characteristics of pulsation quantitatively, the algorithm proposed in this paper is a method that runs in parallel with both the data of ECG and differential pulse simultaneously. these concepts are based upon the idea that thfee Q points of ECG give obious discrimination of one entire period of pulse in any abnormal cases, and newly defined feature lines at the differential counterpart can be used to recogrlize sDme significant points in one period of pulses.

  • PDF

Propagation characteristic analysis and measurement of gaussian pulse signals on the microstrip line (마이크로스트립 선로상 가우시안 펄스신호의 전파특성 해석 및 측정)

  • Rhee, Seoung-Yeop;Shin, Ho-Sub;Kim, Nam;Kwan, Weon-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.6
    • /
    • pp.1425-1432
    • /
    • 1998
  • The propagation properties of Gaussian pulse signals on the microstrip line are investigated by the Kirschning & Jansen's approximated equation to meet the frequency range of a pulse, accuracy, and geometrical requiremtns of the microstrip line. The dispersion of pulse signals is analyzed regarding to the relative permittivity .epsilon.$_{r}$, substrate height h and strip width w of the microstrip line. To verify theoretical results, several samples of 50.OMEGA. microstrip lines are fabricated. And the characteristics of pulse propagation along these lines are simple measured using VNA(Vector Network Analyzer) with time-domain analysis function. A fairly good agreement has been found between the measured pulse waveforms and computer simulations.

  • PDF

A Comparative Study of Methods of Measurement of Peripheral Pulse Waveform

  • Kang, Hee-Jung;Lee, Yong-Heum;Kim, Kyung-Chul;Han, Chang-Ho
    • The Journal of Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.98-105
    • /
    • 2009
  • Objective: Increased aortic and carotid arterial augmentation index (AI) is associated with the risk of cardiovascular disease. The most widely used approach for determining central arterial AI is by calculating the aortic pressure waveform from radial arterial waveforms using a transfer function. But how the change of waveform by applied pressure and the pattern of the change rely on subject's characteristics has not been recognized. In this study, we use a new method for measuring radial waveform and observe the change of waveform and the deviation of radial AI in the same position by applied pressure. Method: Forty-six non-patient volunteers (31 men and 15 women, age range 21-58 years) were enrolled for this study. Informed consent in a form approved by the institutional review board was obtained in all subjects. Blood pressure was measured on the left upper arm using an oscillometric method, radial pressure waves were recorded with the use of an improved automated tonometry device. DMP-3000(DAEYOMEDI Co., Ltd. Ansan, Korea) has robotics mechanism to scan and trace automatically. For each subject, we performed the procedure 5 times for each applied pressure level. We could thus obtain 5 different radial pulse waveforms for the same person's same position at different applied pressures. All these processes were repeated twice for test reproducibility. Result: Aortic AI, peripheral AI and radial AI were higher in women than in men (P<0.01), radial AI strongly correlated with aortic AI, and radial AI was consistently approximately 39% higher than aortic AI. Relationship between representative radial AI of DMP-3000 and peripheral AI of SphygmoCor had strongly correlation. And there were three patterns in change of pulse waveform. Conclusion: In this study, it is revealed the new device was sufficient to measure how radial AI and radial waveform from the same person at the same time change under applied pressure and it had inverse-proportion to applied pressure.

  • PDF

Change of the Finger Photoplethysmographic Pulse Shape According to Decrease of Harmonics (고조파 감소에 따른 지첨용적맥파 파형의 변화)

  • Han, Kyung-Sook;Nam, Tong-Hyun;Shin, Sang-Hoon;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.2
    • /
    • pp.1-12
    • /
    • 2007
  • Objectives: The aim of the present investigation was to determine whether the finger photoplethysmographic waveform of a healthy young man will become analogous to those of healthy old men when the photoplethysmographic harmonic components in the young man decrease. Methods and Results: The finger photoplethysgmoraphy was measured in 21 old men over the age of 60 years and a young men. We acquired the representative pulse waveform of old man by averaging the finger photoplethysmographic waveforms measured in the old men. after the photoplethysmographic harmonic components in the young man were diminished with notch filtering, we compared the representative pulse waveform of old man and the pulse waveforms of which the harmonic components decreased in the young man. The finger photoplethysmographic waveform of the young man became analogous to those of the old men as the photoplethysmographic harmonic components in the young man were diminished with notch filtering. Conclusions: Decrease of the second harmonic component may be a precondition of typical age-related change of the pulse waveform.

  • PDF