• Title/Summary/Keyword: pulse wave factor

Search Result 49, Processing Time 0.022 seconds

A Literature Study on the Diagnostic Factors and Value as a Syndrome of Damjeok (담적의 진단요소 및 증후군으로서의 가치에 대한 문헌고찰)

  • Yun-Seo Lim;Gi-Hwan Rho;Gyu-Ho Choi;Sang-Hyun Lee;Seo-Hyung Choi
    • The Journal of Korean Medicine
    • /
    • v.44 no.3
    • /
    • pp.170-188
    • /
    • 2023
  • Objectives: The purpose of this study is to investigate the diagnostic factors of Damjeok in the literature. Methods: This study used the databases of five (Mediclassics, RISS, KMbase, OASIS, CNKI) to analyze diagnostic factors of Damjeok. Literatures published by May 2023 were assessed and we classified 91 literatures dealing with diagnostic factors by 5 categories, 'characteristics', 'location', 'symptom', 'pulse wave & tongue feature', and 'eating habits & lifestyle'. Results: Damjeok is mainly formed at the stomach in the form of lump or hard seed, and it can be observed in other regions or even the whole body by its trait of floating. Damjeok mainly shows symptoms of the digestive system and also causes various symptoms associated with the respiratory system and infection, musculoskeletal system, urogenital system, neuropsychiatric system and cardiovascular system. Regarding pulse wave and tongue feature, a slippery wave and greasy coated tongue are typical features of Damjeok. Additionally, bad eating habits and a lack of exercise have been described as a factor that cause and aggravate Damjeok. Conclusions: The two most important factors in the diagnosis of Damjeok are abdominal stiffness by physical examination and digestive symptoms, and these correspond to the definition of a syndrome. Diagnostic factors based on literature evidence will provide clues to the clinical diagnosis of Damjeok syndrome.

The Single Phase Converter of Power Factor Collection Type with Simple Switching Method (간이 스위칭법에 의한 단상 역률개선형 컨버터)

  • 문경희;고강훈;김은수;곽동걸;조판제;이현우
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.323-326
    • /
    • 1999
  • For decrease the harmonic current components of the power source, a first method is insert the choke coil that used the choke input type rectifier, the booster chopper circuit and buck chopper circuit. And the several method are studying like as the PWM(Pulse Width Modulation) converter and the active filter type which is used the high frequency switching and the sinusoidal wave formed input current. In this type, there are many problem as a low efficiency, increased the noise, the high leakage current and cost up by the high frequency switching. For improve this problems, the partial resonan method is used on the booster inducter and lossles snubber condenser. This method decreased the distortion factor has lower harmonic components than the hard switching and there is no switching loss by the ZCS(Zero Current Switching) at switch turn-on and the ZVS(Zero Voltage Swithcing) at switch turn-off

  • PDF

Analysis, Design and Implementation of an Interleaved Single-Stage AC/DC ZVS Converters

  • Lin, Bor-Ren;Huang, Shih-Chuan
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.258-267
    • /
    • 2012
  • An interleaved single-stage AC/DC converter with a boost converter and an asymmetrical half-bridge topology is presented to achieve power factor correction, zero voltage switching (ZVS) and load voltage regulation. Asymmetric pulse-width modulation (PWM) is adopted to achieve ZVS turn-on for all of the switches and to increase circuit efficiency. Two ZVS half-bridge converters with interleaved PWM are connected in parallel to reduce the ripple current at input and output sides, to control the output voltage at a desired value and to achieve load current sharing. A center-tapped rectifier is adopted at the secondary side of the transformers to achieve full-wave rectification. The boost converter is operated in discontinuous conduction mode (DCM) to automatically draw a sinusoidal line current from an AC source with a high power factor and a low current distortion. Finally, a 240W converter with the proposed topology has been implemented to verify the performance and feasibility of the proposed converter.

A Systemic Review of Pulse Contour Analysis and Fourier Spectrum Analysis on the Photoplethysmography of Digit (지첨용적맥파의 파형분석과 주파수분석에 대한 문헌적 연구)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.1
    • /
    • pp.48-60
    • /
    • 2007
  • Palpation of the pulse has been used in Korean traditional medicine since ancient times to assess physical health. Pulse wave contour may be obtained by measuring arterial pressure or blood volume change of skin. The latter is called as Photoplethysmography(PPG) or digital volume pulse(DVP). The PPG signal is measured by a device comprising an infrared light sourece and a photodetector. Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. The contour of the PPG is formed as a result of a complex interaction between the left ventricle and the systemic circulation. It usually exhibits an early systolic peak and an early diastolic peak. the first peak is formed mainly by pressure trasmitted along a direct path from the left ventricle to the finger. The second peak is formed in part by pressure transmitted along the aorta and large arteries to sites of impedance mismatch in the lower body. The contour of the PPG is sensitive to changes in arterial tone and is influenced by ageing and large artery stiffness. Measurements taken directly from the PPG or from its second derivative can be used to assess these properties. In some mathematical approaches, the extraction of periodic components using frequency analysis was tried to analysis of the PPG. But we don't understand yet what kind of factor in the cardiovascular system or human body is related with the respective specific Fourier components of PPG. This review describes the background to measurement principles, representative contour, contour analysis and frequency domain analysis of PPG, and current and future.

  • PDF

An Integrated Circuit design for Power Factor Correction (역률 개선 제어용 집적회로의 설계)

  • Lee, Jun-Sung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.5
    • /
    • pp.219-225
    • /
    • 2014
  • This paper describes an IC for Power Factor Correction. It can use electrical appliances which convert power from AC to DC. The power factor can be influenced not only phase difference of voltage and current but also sudden change of current waveform. This circuit enables current wave supplied to load by close to sinusoidal and minimum phase difference of voltage and current waveform. A self oscillated 10[kHz]~100[kHz] pulse signal converted to PWM waveform and it chops rectified full wave AC power which flows to load device. The multiplier and zero current detector circuit, UVLO, OVP, BGR circuits were designed. This IC has been designed and whole chip simulation use 0.5[um] double poly, double metal 20[V] CMOS process.

A study on the PWM(pulse witdh modulation) current source Inverter with utility (태양광발전 연계 시스템에 의한 PWM 전류형 인버어터에 관한 연구)

  • Hwang, Lak-Hoon;Choi, Ho-Kyu;Sin, Yang-Ho;Lee, Chun-Sang;Kim, Ju-Rae;Jo, Sang-Rou;Jo, Moon-Taeck
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1020-1022
    • /
    • 2001
  • because the output of solar cell is direct, it is necessary to install D/A converter system for A.C load, and in case of driving utility line system, it is possible to drive system relation when the system supplies sinusodal current ant voltage having unit power factor. As the characteristics of the soar cell output the is influenced by dailysunight charge, for more electric power it is essential to control the direction toward the san so that the driving point of solar cell can always operate near maximum output point. PWM modulation device among electric power converters must have stable modulation at anytime when it includes noise-factors such as noise-wave and noises on electric voltage wave, a synchronous signal system. In dealing with synchronous signal for control and control signal by microprocessor, it is necessary to compensate it because there is time difference between sample paint and carrier wave. On this papers, single phase PWM current type invertor controled the solar cell having typical voltage dropping character has optimun short current in short, reduces D.C reactance, composes controller for modulation and keeps lower harmonic and high power factor keeping maximum output of solar cell according daily sunlight charge variation.

  • PDF

A Study about Correlation between Hot Flush and Pulse Wave Velocity(PWV)/Ankle-Brachial Index(ABI) in the Climacteric Women (갱년기 여성의 안면홍조와 맥파 전달 속도(PWV) 및 상완 발목 지수(ABI)의 상관성에 관한 연구)

  • Kim, Eun-Gyung;Hwang, Deok-Sang;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Jin-Moo;Lee, Chang-Hoon;Lee, Kyung-Sub
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.23 no.1
    • /
    • pp.53-64
    • /
    • 2010
  • Purpose: This study was performed to observe the correlation between Hot flush and pulse wave velocity(PWV), ankle brachial index(ABI) in the Climacteric women. Methods: We studied 63 climacteric women visiting OO hospital from 8th January 2007 to 22nd April 2009. The subjects were categorized in two groups, the hot flush group(37) and normal group(26). For the study, the subjects were selected by excluding the patients who receive treatment affect hot flush or have disease affect arterial states. We assessed PWV and ABI of two groups by Oscillometric method using VS-1000(Form PWV/ABI; Fukuda Denshi, Co., Ltd., Japan). From these results, we studied the correlation between hot flush and PWV/ABI by Wilcoxon Mann Whitney Test. Results: 1. It is shown that hot flush group was no significant correlation with normal group. There is no significant factor among R-PWV, L-PWV, R-ABI, L-ABI. However, L-ABI have shown relatively higher correlation with comparison to the other factors.(p-value<0.05) 2. R-PWV, L-PWV significantly increased in menopause group than in premenopause group though there is no relation to the hot flush. (p-value<0.01) Conclusion: Though the results showed no correlations between Hot flush and PWV/ABI in the Climacteric women, L-ABI showed relatively higher correlation with hot flush than others. R-PWV, L-PWV showed significant correlation between premenopause and menopause.

A Study on the Power Control Characteristics of a Power Supply for Electrodeless Lamp (무전극 램프(Electrodeless Lamp) 구동용 전원장치의 전력제어 특성에 관한 연구)

  • Lee, Sung-Geun;Jeon, Su-Kyun;Jang, Min-Kyu;Kim, Dong-Sok;Kim, Yoon-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.65-67
    • /
    • 2003
  • This paper describes a design of power supply for electrodeless lamp system to be easy to control electric power widely keeping the high power factor. Proposed system is composed of power factor correction(PFC) circuit, half bridge(HB) inverter, high voltage transformer, full wave rectifier to supply dc number kV's magnetron(MGT) anode voltage in the second of high voltage transformer and magnetron. It was confirmed that the proposed circuits can correct the 99.8[%] power factor and control input power of the magnetron up to 33.3[%] linearly by adjusting of pulse frequency of the inverter through the experiment.

  • PDF

A Study about Correlations between the Interpretations of Autonomic Bioelectric Response Recorder (ABR-2000) and Diagnosis System of Oriental Medicine (DSOM) / 3D Blood Pressure Pulse Analyzer (3D-MAC) (생체전기자율반응 측정기와 한방진단시스템 및 맥진기 검사 해석의 상관성 연구)

  • Ok, Jin-Yoo;Lee, In-Seon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.2
    • /
    • pp.31-48
    • /
    • 2018
  • Objectives: This study was performed to observe the correlations between the results of ABR-2000 and DSOM / 3D-MAC to evaluate the feasibility of ABR-2000 as a oriental medical diagnostic criteria. Methods: We studied 547 women visiting ${\bigcirc}{\bigcirc}$ hospital from December 2012 to June 2015. The subjects were categorized in two groups, 'Hypotonia' and 'Non-Hypotonia' by the result of ABR-2000 and assessed the result of DSOM, 3D-MAC for each group. The differences of pulse wave factors by group also studied. Results: 1. There was no significant difference between two groups about the output frequency of pathogenic factors in DSOM while the result showed the higher correlation in Hypotonia group in terms of the companion tendency of pathogenic factors and syndromes formed by the combination of pathogenic factors. 2. The pulse waves of Hypotonia group were mostly slow, weak, tense and stiff than Non-Hypotonia group. Conclusions: 1. In Hypotonia group, yin deficiency (陰虛) factor was frequently accompanied and consumption (虛損) of various organs based on the yin deficiency (陰虛) was observed. It means chronic and severe condition of exhaustion syndrome (虛勞). 2. The result of 3D-MAC also means pathological feature of yin syndrome (陰 證) and consumption (虛損). Besides, lower scores of Body Surface Area (BSA), body weight, and Body Mass Index (BMI) were associated with body weakness (體瘦), a symptom of exhaustion syndrome (虛勞).

Study on the Impulse Characteristics for applying to the Ultra-wideband Antennas (초광대역 안테나에 적용 가능한 임펄스 특성에 관한 연구)

  • Doojin Lee;Muhun Park
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.362-368
    • /
    • 2023
  • In this paper, we presented the characteristics of the impulse signal which is applicable to the ultra-wideband antennas. In general, the width of the impulse has around sub nano or pico seconds in the time domain, where it corresponds to the wideband in the frequency domain. We confirmed by experiment that the impulse has around 130ps of the pulse width and bandwidth of 4GHz when 10MHz of sine wave excited as an input pulse. The fidelity factor was calculated in the time domain and -10dB bandwidth in the frequency domain was investigated for resistively loaded dipole antennas with different resistance per unit length. The received impulse signal through the wideband antennas is confirmed in the time and frequency domains that received pulse is to be similar to the generated impulse. The fidelity and bandwidth of the quantity value are 0.98 and 3.4GHz, respectively.