• 제목/요약/키워드: pulse test

검색결과 1,175건 처리시간 0.031초

컴퓨터 맥진시스템 (Computerized pulse diagnosis system)

  • 이호재;허웅
    • 전자공학회논문지B
    • /
    • 제33B권4호
    • /
    • pp.81-90
    • /
    • 1996
  • In this paper, we implemented a computerized pulse diagnosis system for the developement of pulse diagnosis algorithms and the generalization of the pulse diagnosis. The system consists of the hardware and software. The hardware detects pulse waves and inputs the waves into the computer system, while the software not only manages and analyzes the input pulse wave data but also privides the database. In order to clinically test the developed pulse diagnosis system, we applied the carotid-radial pulse diagnosis algorithm to the system. As the results, it is found that the genralizatio of the pulse diagnosis is possible.

  • PDF

결정질 암반내 지하연구시설에서 수행한 현장수리시험법 적용성 연구 (A Study on the Applicability of the Hydraulic Test Method Performed at an underground Research Facility in Crystalline Rock)

  • 박경우;고낙열;지성훈
    • 자원환경지질
    • /
    • 제53권2호
    • /
    • pp.121-131
    • /
    • 2020
  • 본 논문에서는 지하연구시설에서 결정질 암반의 수리지질특성을 도출하기 위해 일반적으로 수행하는 수리시험법의 적용 가능성 및 신뢰성을 평가할 목적으로, 펄스시험, 슬러그시험과 정압시험을 이용하여 각 시험 결과로부터 도출되는 투수량계수를 서로 비교해 보았다. 펄스시험과 슬러그시험의 결과를 비교해 볼 때, 매질의 투수성이 낮은 시험 구간에서는 투수량계수가 매우 유사하게 도출되었지만, 투수성이 비교적 큰 구간에서는 다소 차이를 보였다. 그리고 투수성이 큰 구간에서 정압시험 결과에 비해 순간수위변화시험의 결과가 다소 크게 나타났다. 이러한 투수성의 차이는 각 수리시험에서 적용되는 수리 영향 반경의 상이함에 기인한 것으로 판단된다. 비록 각각의 현장수리시험에서 도출되는 결과가 매질의 투수성을 동일하게 반영한다고 할 수는 없지만, 단열의 불균질한 분포가 투수성에 영향을 주는 결정질 암반에서의 수리지질특성을 도출할 때 수리영향반경이 큰 정압시험이나 정률시험뿐만 아니라 비교적 빠른 시간에 수리지질특성을 파악할 수 있는 슬러그시험과 펄스시험을 통해서도 매질의 수리지질특성을 설명할 수 있는 것으로 사료된다.

Suppression of performance degradation due to cold-head orientation in GM-type pulse tube refrigerator

  • Ko, Junseok;Kim, Hyobong;Park, Seong-Je;Hong, Yong-Ju;Koh, Deuk-Yong;Yeom, Hankil
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권4호
    • /
    • pp.50-53
    • /
    • 2012
  • This paper describes experimental study on GM-type pulse tube refrigerator (PTR). In a PTR, the pulse tube is only filled with working gas and there exists secondary flow due to a large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus, the cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube refrigerator is fabricated and tested. The cooing performance of the fabricated PTR is measured as varying cold-head orientation angle and the results are used as reference data. Then, we divided interior space of pulse tube into three segments, and fixed the various size of screen mesh at interface of each segment to suppress the performance degradation due to secondary flow. For various configuration of pulse tube, no-load test and heat load test are carried out with the fixed experimental condition of charging pressure, operating frequency and orifice valve turns. From experimental results, the fine screen mesh shows the effective suppression of performance degradation for the large orientation angle, but the use of screen mesh cause the loss of cooling capacity rather than the case of no insertion into pulse tube. It should be compromised whether the use of screen mesh in consideration of the installation limitation of a GM-type pulse tube refrigerator.

초음파기기를 이용한 맥상(脈象) 연구 (A Study on Pulse Pattern Using Ultrasonic Device)

  • 김희영;박정빈;금유정;여인금;엄동명;송지청
    • 대한한의학원전학회지
    • /
    • 제34권2호
    • /
    • pp.85-94
    • /
    • 2021
  • Objectives : Pulse diagnosis is one of the main diagnostic methods of Korean Medicine that understands the patient's condition and illness by reading changes in the patient's pulse, which is described in terms of pulse condition While they are described in detail in medical texts, it is difficult to grasp their true nature, as the written descriptions fail to do justice to the experience of pulse taking it tries to convey. As a way to approach pulse condition the effect of the body's tension on the radial vein was measured using an ultrasonic device, after which the measured changes and how they could be reflected in pulse condition were studied. In other words, changes in the radial vein following induced tension were analyzed. Methods : 1) The thickness of the subject's radial vein was measured using a linear probe of an ultrasonic device[LOGIQ 5 Basic, GE, USA]. 2) Fatigue level was increased through artificial stimulation using the Gripmeter[ks-301, Lavisen, Korea]. 3) Thickness of the radial vein post tension induction was measured. 4) The results were analyzed with the Tukey test or paired t-test as post hoc tests. Results : Thickness of the radial vein of the subject pre- and post- Gripmeter stimulation decreased with significance. Conclusions : Constriction of the radial vein that happened after tension induction could be linked to the Tight Pulse[緊脈] that is related to patterns of contraction and pulling.

RC 및 PSC 콘크리트에서 반발도 및 초음파 속도의 변화에 대한 연구 (A Study on the Statistical Distribution of Rebound Number and Ultrasonic Pulse Velocity in RC and PSC Concrete Structures)

  • 사민형;윤영근;이인복;우인성;오태근
    • 한국안전학회지
    • /
    • 제32권4호
    • /
    • pp.53-58
    • /
    • 2017
  • The rebound hammer test and the measurement of ultrasonic pulse velocity(UPV) have been widely used for the physical properties & condition evaluation of reinforced & prestressed concrete structures for a long time, but the acoustoelastic effects by the prestressing in the prestressed concrete structures on the rebound number and ultrasonic pulse velocity have not been studied clearly. Therefore, this study investigated the data distribution of the rebound numbers and ultrasonic pulse velocities in reinforced and prestressed concrete slabs of $3000{\times}3000mm$ with a thickness of 250 mm. Also, the Kolmogorov-Smirnov goodness-of-fit test was done in order to identify statistical consistency and reliability. The statistical analysis results show that the rebound number and ultrasonic pulse velocities increased about 1.9% and 2.5%, respectively when prestressing was applied. As expected, the UPV shows better statistical reliability and potential for in situ evaluation than the RB because the RB are more sensitive to testing posture, surface condition, temperature and humidity so on. The experimental data in this study can be used for the condition assessment of reinforced and prestressed concrete structures by the rebound number and ultrasonic pulse velocity.

지시적 심상요법이 혈압과 맥박에 미치는 효과 - 간호대학생을 대상으로 - (The Effect of Guided Imagery on Blood Pressure and Pulse Rate - In Nursing Students -)

  • 최은옥;이동숙
    • Journal of Korean Biological Nursing Science
    • /
    • 제5권2호
    • /
    • pp.31-39
    • /
    • 2003
  • The purpose of this study was to test the effect of guided imagery on blood pressure and pulse rate. The subjects were thirty-nine nursing students in I university located in Busan, Korea To enhance the effect of treatment, they were trained getting themselves absorbed in guided imagery on three different occasions before the study. Actually in the study, the subjects were given instruction in Mason's guided imagery for 19 minutes and 58 seconds. Blood pressure and pulse rate were measured before and after guided imagery application. The data were analyzed through paired t-test. The Results were as follows : 1) There was a significant decrease in systolic blood pressure after the use of guided imagery. 2) There was no significant decrease in diastolic blood pressure after the use of guided imagery. 3) There was a significant decrease in pulse rate after the use of guided imagery. These results indicate that guided imagery is a helpful technique for decreasing blood pressure and pulse rate, which are increased in stress condition.

  • PDF

격막형 PSD를 적용한 소형 추진기관 설계 및 시험평가 (Design, Test and Evaluation on the PSD with Thermal Barrier Type for Subscale Dual Pulse Rocket Motor)

  • 김진용;권태하;이원복;조원만;이방업;윤남균;이영우
    • 한국추진공학회지
    • /
    • 제18권6호
    • /
    • pp.82-87
    • /
    • 2014
  • 이중펄스 로켓모타는 두 개의 펄스모타 사이에 격벽 또는 격막을 통하여 1단 펄스모타 연소 후 2단 펄스모타가 연소하는 방식으로 일회성 추력 방식이 아닌 효율적으로 이중추력을 조절한다. 이러한 추력 배분을 통하여 사거리와 종말속도를 증가시켜 미사일의 기동성 및 사거리를 향상시킨다. 본 연구에서는 격막 펄스분리장치를 갖는 소형 이중펄스모타에 설계하였고 지상연소시험을 통하여 특성을 분석하였다. 결과적으로 얻어진 데이터 값들은 향후 F-type 이중펄스모타의 설계에 적용가능할 것으로 판단된다.

SRM의 DC linke 전압리플을 고려한 단일 펄스 구동 방식의 특성 해석 (The Characteristic Analysis of SRM Dirven by Single-pulse Mode Considering the Voltage Ripple of DC Linke)

  • 이성구;정대성;이주
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1976-1980
    • /
    • 2008
  • This paper deals the characteristic analysis of Switched Reluctance Motor(SRM) driven by single-pulse mode considering dc link voltage ripple. Two dimensional time-stepped Finite Element Method(FEM) is used to analyze the characteristic of SRM driven by single-pulse mode with dc link voltage ripple. The analysis results is verified by experimental test.

PLACKETT-BURMAN MODEL을 이용한 Cu-Ni합금의 PULSE MIG 용접 변수해석 (Application of Plackett-Burman model in welding experiments : effects of welding parameters on bead shape in Cu-Ni PULSE MIG process)

  • 문영훈;이기학;허성도
    • Journal of Welding and Joining
    • /
    • 제5권4호
    • /
    • pp.47-53
    • /
    • 1987
  • The purpose of this study is to reexamine our test method in the light ofstatistical methods for data interpretation. Our trial to apply Plackett-Burman statistical model in multifactorial welding experiments shows that is saves much time and cost and extracts very accurate results. In this study, the parametric effects of bead shape on pulse MIG process in Cu-Ni alloy are investigated for verifying our trial.

  • PDF

초음파법에 의한 콘크리트 응결시간 측정에 관한 연구 (Study on the Setting time of Concrete Using Ultrasonic Test)

  • 구본창;강민호;이대근;김종우;하재담;박석균
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.707-711
    • /
    • 1998
  • Ultrasonic test usually was used for defect detection, crack depth measurements and strength estimation of hardened concrete. The essence of the pulse velocity method is that the transition time of an ultrasonic longitudinal pulse is measured in concrete. Ultrasonic velocity was propagated to the age of concrete, made a radical change at that time when concrete was setted. This study which monitored the change in a concrete by ultrasonic test was performed to estimate initial setting and final setting.

  • PDF