Browse > Article
http://dx.doi.org/10.14369/jkmc.2021.34.2.085

A Study on Pulse Pattern Using Ultrasonic Device  

Kim, Hee Young (Dept. of Physiology, College of Korean Medicine, Daegu Haany University)
Park, Jeongbin (Korean Medicine Doctor at Boin Traditional Korean Medicine Clinic)
Keum, Yujeong (Dept. of Medical History, College of Korean Medicine, Daegu Haany University)
Yeo, Inkeum (Professional Graduate School of Korean Medicine, Wonkwang University)
Eom, Dongmyung (Dept. of Medical Classics, College of Korean Medicine, Wonkwang University)
Song, Jichung (Dept. of Medical History, College of Korean Medicine, Daegu Haany University)
Publication Information
Journal of Korean Medical classics / v.34, no.2, 2021 , pp. 85-94 More about this Journal
Abstract
Objectives : Pulse diagnosis is one of the main diagnostic methods of Korean Medicine that understands the patient's condition and illness by reading changes in the patient's pulse, which is described in terms of pulse condition While they are described in detail in medical texts, it is difficult to grasp their true nature, as the written descriptions fail to do justice to the experience of pulse taking it tries to convey. As a way to approach pulse condition the effect of the body's tension on the radial vein was measured using an ultrasonic device, after which the measured changes and how they could be reflected in pulse condition were studied. In other words, changes in the radial vein following induced tension were analyzed. Methods : 1) The thickness of the subject's radial vein was measured using a linear probe of an ultrasonic device[LOGIQ 5 Basic, GE, USA]. 2) Fatigue level was increased through artificial stimulation using the Gripmeter[ks-301, Lavisen, Korea]. 3) Thickness of the radial vein post tension induction was measured. 4) The results were analyzed with the Tukey test or paired t-test as post hoc tests. Results : Thickness of the radial vein of the subject pre- and post- Gripmeter stimulation decreased with significance. Conclusions : Constriction of the radial vein that happened after tension induction could be linked to the Tight Pulse[緊脈] that is related to patterns of contraction and pulling.
Keywords
pulse condition; tight pulse; ultrasound; fatigue;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Hu CS, Chung YF, Yeh CC, Luo CH. Temporal and Spatial Properties of Arterial Pulsation Measurement Using Pressure Sensor Array. Evid Based Complement Alternat Med. 2012. pp.1-9. https://doi.org/10.1155/2012/745127   DOI
2 Mingjun Xu, et al. The independent and add-on values of radial intima thickness measured by ultrasound biomicroscopy for diagnosis of coronary artery disease. European Heart Journal - Cardiovascular Imaging, 2019. 20(8). pp.889-896. https://doi.org/10.1093/ehjci/jez026   DOI
3 Dipak Kotecha, et al. Radial artery pulse wave analysis for non-invasive assessment of coronaryartery disease. International Journal of Cardiology. 2013. 167(3). pp.917-924. https://doi.org/10.1016/j.ijcard.2012.03.098   DOI
4 Mitchell, J.H., Abnormal cardiovascular response to exercise in hypertension: contribution of neural factors. Am J Physiol Regul Integr Comp Physiol. 2017. 312(6). pp.851-R863. https://doi.org/10.1152/ajpregu.00042.2017   DOI
5 李時珍. 瀕湖脈學. 北京. 人民衛生出版社. 1988. p.18, 66.
6 孫思邈. 備急千金要方. 北京. 中國醫藥科技出版社. 2018. p.481.
7 李梴. 醫學入門. 北京. 人民衛生出版社. 2019. p.146, 148.
8 張介賓. 懸吐註釋 景岳全書. 서울. 法仁文化社. 2007. p.144.
9 盛增秀 主編. 脈學類聚 下. 北京. 人民衛生出版社. 2012. p.1492.
10 金信根. 韓國醫學大系 39, 纂圖方論脈訣集成. 서울. 麗江出版社. 1992. p.253.
11 윤영준. 맥진기 제작과 맥파 분석. 서울대학교 석사학위논문. 2002.
12 Kim JU, Lee YJ, Lee L, Kim JY. Differences in the Properties of the Radial Artery between Cun, Guan, Chi, and Nearby Segments Using Ultrasonographic Imaging: A Pilot Study on Arterial Depth, Diameter, and Blood Flow. Evid Based Complement Alternat Med. 2015. pp.1-8. https://doi.org/10.1155/2015/381634   DOI
13 張仲景. 傷寒論. 北京. 人民衛生出版社. 2012. p.4, 25.
14 朴炅, 金興濟, 全鍾皓. 譯釋 脈學輯要·脈語. 서울. 大星文化社. 1997. p.24.
15 uBio's 누리집 [[cited Apr 18th, 2021], Available from: https://ubios.modoo.at/
16 대요메디 누리집 [cited Apr 18th, 2021], Available from: http://www.daeyomedi.com/
17 Zhang HF, Wu SJ, Li WX, Wang YH, Dong ML, Yang LX. Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry. Evid Based Complement Alternat Med. 2018. pp.1-7. https://doi.org/10.1155/2018/4187349   DOI
18 Moura NG, Cordovil I, Ferreira Ade S. Traditional Chinese medicine wrist pulse-taking is associated with pulse waveform analysis and hemodynamics in hypertension. J Integr Med. 2016. 14(2). pp.100-113. https://doi.org/10.1016/S2095-4964(16)60 233-9   DOI
19 Kim HH, Kim JY, Park YJ, Park YB. Development of pulse diagnostic devices in Korea. Integr Med Res. 2013. 2(1). pp.7-17. https://doi.org/10.1016/j.imr.2013.01.003   DOI
20 허현. 한의학 대표 맥상 모델링 및 맥파 재현시스템 개발. 2016. 연세대학교 보건대학원 박사학위논문. 2016.