• Title/Summary/Keyword: pulse protocol

Search Result 82, Processing Time 0.02 seconds

Effective of Body Temperature Increasing during Brain MRI scan (MRI 검사 시 체온상승 효과: 1.5 T vs 3.0 T)

  • Kim, Myeong Seong;Lee, Jongwoong;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 2017
  • As the Radiofrequency(RF) increases with the magnetic field strength, the wavelength of the RF excitation field becomes smaller, which leads to more the thermal effect in the human-body placed in the electric field. MRI scanner used was GE signa 1.5T, HDx 3.0T and Philips 3.0T with same routine clinical sequence protocol. Therefore temperature was measured before and after each scan. Taken the temperatures in the ear with ear infra-red type thermometer(Braun co). 3.0T were temperature increases more than $0.15^{\circ}C$ and GE 3.0T MRI equipment about $0.14^{\circ}C$ higher than the Philips 3.0T MRI(p<0.012). Psychogenic status was investigated by the survey respondents about their status can not just answer therefore, a little different from the expected. In our study of Thermal effect of clinical MRI with clinical protocol sequence, we found that the 3.0T in the body-temperature rise was greater than the 1.5T. Therefore, in clinical 3.0T examine the dangerous situation caused by the temperature rise occurred (burns, impaired thermoregulatory mechanism in patients with high-temperature damage, exhaustion occurs due to excessive sweating), not to appear the more watched the patient's condition with procedure.

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

Design and Implementation of a Mobile Ubiquitous Healthcare System (모바일 유비쿼터스 헬스케어시스템 설계 및 구현)

  • Lee, Bong-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.781-793
    • /
    • 2010
  • Recently, owing to the development of ubiquitous sensor network and mobile communication technologies, many studies on healthcare system are being carried out. In this paper, we have designed and implemented a mobile u-Healthcare system based on sensor network. The u-Healthcare system is composed of three components: wireless sensor network at home, healthcare center located at remote site, and gateway which relays sensing physiological signals to healthcare center. In order to measure patient's physiological signal three sensors are used: three channel ECG sensor, pulse oximeter, and blood pressure sensor. Each sensor is mounted on a mote which can send gathered signal to the base node using Zigbee communication protocol. Once the base node receives physiological signal from each sensor, the client in the base node transfers the signal to the healthcare center. The received physiological signal at the healthcare center is analyzed and processed using various algorithms. The processed results are compared to the standard healthcare database and appropriate treatment including dietetics and exercise cure would be sent to the patient as feedback using SMS message or healthcare center web site. Each patient can check and manage one's health state every day using the healthcare system and gain a recovery under the treatments from minor health problems.

Generation of Embryonic Stem Cell-derived Transgenic Mice by using Tetraploid Complementation

  • Park, Sun-Mi;Song, Sang-Jin;Choi, Ho-Jun;Uhm, Sang-Jun;Cho, Ssang-Goo;Lee, Hoon-Taek
    • Proceedings of the Korean Society of Developmental Biology Conference
    • /
    • 2003.10a
    • /
    • pp.121-121
    • /
    • 2003
  • The standard protocol for the production of transgenic mouse from ES-injected embryo has to process via chimera producing and several times breeding steps, In contrast, tetraploid-ES cell complementation method allows the immediate generation of targeted murine mutants from genetically modified ES cell clones. The advantage of this advanced technique is a simple and efficient without chimeric intermediates. Recently, this method has been significantly improved through the discovery that ES cells derived from hybrid strains support the development of viable ES mice more efficiently than inbred ES cells do. Therefore, the objective of this study was to generate transgenic mice overexpressing human resistin gene by using tetrapioid-ES cell complementation method. Human resistin gene was amplified from human fetal liver cDNA library by PCR and cloned into pCR 2.1 TOPO T-vector and constructed in pCMV-Tag4C vector. Human resistin mammalian expression plasmid was transfected into D3-GL ES cells by lipofectamine 2000, and then after 8~10 days of transfection, the human resistin-expressing cells were selected with G418. In order to produce tetraploid embryos, blastomeres of diploid embryos at the two-cell stage were fused with two times of electric pulse using 60 V 30 $\mu$sec. (fusion rate : 93.5%) and cultured upto the blastocyst stage (development rate : 94.6%). The 15~20 previously G418-selected ES cells were injected into tetraploid blastocysts, and then transferred into the uterus of E2.5d pseudopregnant recipient mice. To investigate the gestation progress, two El9.5d fetus were recovered by Casarean section and one fetus was confirmed to contain human resistin gene by genomic DNA-PCR. Therefore, this finding demonstrates that tetraploid-ES mouse technology can be considered as a useful tool to produce transgenic mouse for the rapid analysis of gene function in vivo.

  • PDF

Comparison of Effects of Transcutaneous Electrical Nerve Stimulation (TENS) and San-Yin-Jiao (SP6) Acupressure on Primary Dysmenorrhea (경피신경전기자극(TENS)과 삼음교 지압이 원발성 월경통에 미치는 효과 비교)

  • Oh, Yeong-Taek
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.415-424
    • /
    • 2014
  • PURPOSE: This study examined the effect of high-frequency transcutaneous electrical nerve stimulation (TENS) and San-Yin-Jiao (SP6) acupressure on primary dysmenorrhea. Furthermore, the difference in effectiveness between the two methods were compared. METHODS: Twenty-six students participated in this study, and were randomly assigned to a high-frequency TENS group(experimental 1, n=9), a San-Yin-Jiao (SP6) acupressure group(experimental 2, n=9), and no treatment group(control, n=8). They were assessed and treated on the first day of their menstruation. The TENS protocol included applying 20 minutes of stimulation with a frequency of 100Hz, $100{\mu}sec$ pulse width. Four electrodes were placed on the skin 3 cm from midline at T12-L1 and S2-3 paravertebral muscles. San-Yin-Jiao (SP6) acupressure should be applied with the thumb for 10 minutes(8 seconds pressure and 2 seconds rest) on the SP6 acupoint. This procedure should be repeated for the other foot. Dysmenorrheal pain measured two pain assessment tools (VAS, DPT) pre-treatment; immediate post-treatment; 30minutes, 1, 2hours; and 3, 4, 5, 6, 24 hours after the VAS test were added. RESULTS: The results showed significant differences in pain assessments (VAS, DPT) after treatment for subjects of experimental group1 (p<.05) and experimental group2 (p<.05), whereas the between-group comparison found no statistically significant differences. CONCLUSION: This result supports the idea that using two methods could be effective in pain reduction among students who suffered from primary dysmenorrhea.

Sustained $K^+$ Outward Currents are Sensitive to Intracellular Heteropodatoxin2 in CA1 Neurons of Organotypic Cultured Hippocampi of Rats

  • Jung, Sung-Cherl;Eun, Su-Yong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.5
    • /
    • pp.343-348
    • /
    • 2012
  • Blocking or regulating $K^+$ channels is important for investigating neuronal functions in mammalian brains, because voltage-dependent $K^+$ channels (Kv channels) play roles to regulate membrane excitabilities for synaptic and somatic processings in neurons. Although a number of toxins and chemicals are useful to change gating properties of Kv channels, specific effects of each toxin on a particular Kv subunit have not been sufficiently demonstrated in neurons yet. In this study, we tested electro-physiologically if heteropodatoxin2 ($HpTX_2$), known as one of Kv4-specific toxins, might be effective on various $K^+$ outward currents in CA1 neurons of organotypic hippocampal slices of rats. Using a nucleated-patch technique and a pre-pulse protocol in voltage-clamp mode, total $K^+$ outward currents recorded in the soma of CA1 neurons were separated into two components, transient and sustained currents. The extracellular application of $HpTX_2$ weakly but significantly reduced transient currents. However, when $HpTX_2$ was added to internal solution, the significant reduction of amplitudes were observed in sustained currents but not in transient currents. This indicates the non-specificity of $HpTX_2$ effects on Kv4 family. Compared with the effect of cytosolic 4-AP to block transient currents, it is possible that cytosolic $HpTX_2$ is pharmacologically specific to sustained currents in CA1 neurons. These results suggest that distinctive actions of $HpTX_2$ inside and outside of neurons are very efficient to selectively reduce specific $K^+$ outward currents.

Programmatic Sequence for the Automatic Adjustment of Double Relaxation Oscillation SQUID Sensors

  • Kim, Kiwoong;Lee, Yong-Ho;Hyukchan Kwon;Kim, Jin-Mok;Kang, Chan-Seok;Kim, In-Seon;Park, Yong-Ki
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.42-47
    • /
    • 2002
  • Measuring magnetic fields with a SQUID sensor always requires preliminary adjustments such as optimum bas current determination and flux-locking point search. A conventional magnetoencephalography (MEG) system consists of several dozens of sensors and we should condition each sensor one by one for an experiment. This timeconsuming job is not only cumbersome but also impractical for the common use in hospital. We had developed a serial port communication protocol between SQUID sensor controllers and a personal computer in order to control the sensors. However, theserial-bus-based control is too slow for adjusting all the sensors with a sufficient accuracy in a reasonable time. In this work, we introduce programmatic control sequence that saves the number of the control pulse arrays. The sequence separates into two stages. The first stage is a function for searching flux-locking points of the sensors and the other stage is for determining the optimum bias current that operates a sensor in a minimum noise level Generally, the optimum bias current for a SQUID sensor depends on the manufactured structure, so that it will not easily change about. Therefore, we can reduce the time for the optimum bias current determination by using the saved values that have been measured once by the second stage sequence. Applying the first stage sequence to a practical use, it has taken about 2-3 minutes to perform the flux-locking for our 37-channel SQUID magnetometer system.

  • PDF

Decreased Voltage Dependent $K^+$ Currents in Cerebral Arterial Smooth Muscle Cells of One-Kidney, One-Clip Goldblatt Hypertensive Rat

  • Oh, Young-Sun;Kim, Se-Hoon;Kim, Hoe-Suk;Jeon, Byeong-Hwa;Chang, Seok-Jong;Kim, Kwang-Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.5
    • /
    • pp.471-479
    • /
    • 1999
  • The Kv channel activity in vascular smooth muscle cell plays an important role in the regulation of membrane potential and blood vessel tone. It was postulated that increased blood vessel tone in hypertension was associated with alteration of Kv channel and membrane potential. Therefore, using whole cell mode of patch-clamp technique, the membrane potential and the 4-AP-sensitive Kv current in cerebral arterial smooth muscle cells were compared between normotensive rat and one-kidney, one-clip Goldblatt hypertensive rat (lK,lC-GBH rat). Cell capacitance of hypertensive rat was similar to that of normotensive rat. Cell capacitance of normotensive rat and 1K,lC-GBH rat were $20.8{\pm}2.3$ and $19.5{\pm}1.4$ pF, respectively. The resting membrane potentials measured in current clamp mode from normotensive rat and 1K,lC-GBH rat were $-45.9{\pm}1.7$ and $-38.5{\pm}1.6$ mV, respectively. 4-AP (5 mM) caused the resting membrane potential hypopolarize but charybdotoxin $(0.1\;{\mu}M)$ did not cause any change of membrane potential. Component of 4-AP-sensitive Kv current was smaller in 1K,lC-GBH rat than in normotensive rat. The voltage dependence of steady-state activation and inactivation of Kv channel determined by using double-pulse protocol showed no significant difference. These results suggest that 4-AP-sensitive Kv channels playa major role in the regulation of membrane potential in cerebral arterial smooth muscle cells and alterations of 4-AP-sensitive Kv channels would contribute to hypopolarization of membrane potential in 1K,lC-GBH rat.

  • PDF

The Effect of Aerobic Exercise Program on Health Status and Physical Fitness in Patients after the Stem Cell Transplantation (유산소 운동이 조혈모세포이식자의 건강상태와 체력에 미치는 효과)

  • Han, Shin-Hi
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.4 no.1
    • /
    • pp.7-19
    • /
    • 2001
  • The Objectives of this research is to determine the effect of aerobic exercise program on health status and physical fitness in patients after the stem cell transplantation. This research design is one-group pretest-post test design. Sixteen subjects were selected from one university hospital in Seoul for the study, they was carried out aerobic exercise three to five times a week for 12 weeks. The period of data collection was from February to July, 2000. The collected data was analysed by descriptive analysis, paired t-test, content analysis SAS program was used for the statistical analysis. The results are as follows : 1. There was a significant improvement in the Physical functioning, Vitality and Reported change (t=2.39, p=0.03; t=2.35, p=0.03; t=2.58, p=0.02) but no change was observed in the Role physical, General health perception, Bodily pain, Social functioning, Role emotional and Mental health. 2. There was a significant improvement in the physical fitness (higher VO2 max, t=2.43, p=0.02; lower systolic pressure, t=-4.09, p=0.001; lower diastolic pressure, t=-3.43, p=0.002; lower pulse rate, t=-3.43, p=0.004; higher muscle sustaining power, t=2.79, p=0.015; higher muscle power, t=5.18 p=0.000; higher power of beginning, t=5.55, p=0.001; higher the sense of equilibrium, t=3.57, p=0.003; higher Hemoglobin, t=5.92, p=0.000; higher Hematocrit, t=5.38, p=0.000). Therefore, this study will provide a theoretical back ground for patients after stem cell transplantation to understand the importance of physical exercise and maintain physical exercise; and for other researches to refer to the results for exercise protocol of rehabilitation program.

  • PDF

On the Performance Enhancements of VC Merging-capable Scheduler for MPLS Routers by Sequence Skipping Method (Sequence Skipping 방법을 이용한 MPLS 라우터의 VC 통합기능 스케쥴러의 성능 향상에 관한 연구)

  • Baek, Seung-Chan;Park, Do-Yong;Kim, Young-Beom
    • Journal of IKEEE
    • /
    • v.5 no.1 s.8
    • /
    • pp.111-120
    • /
    • 2001
  • VC merging involves distinguishing cells from an identical merged VC label. Various approaches have been proposed to help this identification process. However, most of them incur additional buffering, protocol overhead and/or variable delay. They make the provision of QoS difficult to achieve. So it was proposed a merge capable scheduler to support VC-merging (VCMS). However, in situations where all VCs are to be merged or the incoming traffic load is very low, it could happen that there are not enough non-merging cells to snoop. In this situation the scheduler uses special control cells to fill the empty time slots out. Too many control cells can cause high cell loss ratio and an additional packet transfer delay. To overcome the drawbacks, we propose a Sequence Skipping(SS) method where the sequencers skip the empty queues and insert SS cells. We show SS method is suitable for VC-merging and can reduce the cell loss ratio and the mean packet transfer delay through simulations.

  • PDF