A Study on the USN Zigbee Sensor Node for Transmission to Harmful Gas(CO, CO2) Sensing Data (유해가스(CO, CO2) 감지정보 전송을 위한 USN 지그비센서노드 구현)

  • Cheon, Dong-Jin;Park, Young-Jik;Lee, Seung-Ho;Kim, Jeong-Seop;Kwak, Dong-Kurl;Jung, Do-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1302-1308
    • /
    • 2010
  • In this study, Zigbee Sensor Node to transmit harmful gases CO and $CO_2$ information using wireless communication within the ground and underground structures were developed. Wireless communication protocol was used Zigbee Stack included IEEE 802. 15.4 MAC protocol. For wireless transmission of detected harmful gas signal from ADC of MCU was implemented Zigbee Sensor Node that was developed protocol using Serial-Port-Profile(SPP) here. The proposed Zigbee Sensor Node was verified transmission distance from experiments. Transmission distance was into 90m in experiments. Distance experiments were measured at 10m intervals using sine & pulse wave input signal at indoors. The proposed Route Sensor Node was applied mesh routing protocol. When built up USN(Ubiquitous Sensor Network)using Route Sensor Node, transmission distance was not limited. On the experimental results, harmful gas values between direct measurements and USN measurements were consistent. The semiconductor CO sensor and N-DIR $CO_2$ sensor module as a harmful sensor was used. Therefore, the proposed Zigbee Sensor Node was verified about reliability and validity to build USN for transmission of harmful gas information.

Construction of laser induced grating spectrometer and measurement of thermal grating in $C_3H_8$ flame (레이저 유도 격자 분광장치 제작 및 $C_3H_8$화염에서 열 격자 측정)

  • 박철웅;한재원;이중재;이영우;고동섭
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.446-451
    • /
    • 2001
  • We made a laser induced grating spectrometer(LIGS) and measured the thermal grating signal generated in a $C_3$ $H_{8}$ flame. The thermal grating was formed in the C7Ha flame with two second-harmonic Nd:YAG pulse laser beams, and an LIGS signal was generated by Bragg scattering of a probe laser beam A $r^+.laser(488 nm). We found the modulation period of the signal depends linearly on the spacing of the grating set in the flame. We determined flame temperature by fitting the modulated signal and soot concentration with signal strength. Using this technique, we also obtained temperature profile and soot-particle distribution in a $C_3$ $H_{8}$ flame .e .

  • PDF

Fabrication and Output Characteristics of Compact Capacitor Transfer XeCl Laser (용량이행영 소형 XeCl레이저 제작 및 출력특성)

  • 김동환
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.57-65
    • /
    • 1993
  • Small XeCl laser of charge transfer discharge excitation was fabricated and output charateristics were investigated according to gas mixture ratio. Beam cross section of 2.7cm${\times}$1.5cm was obtained by constructing excimer laser which preionization is operated automatically and which has chang profile electrode. According to the component gas mixture ratio, the condition of maximum output energy, efficiency were investigated. The maximum energy, efficiency and specific energy were obtained 230 mJ, 1.6% and 1.1 J/l, respectively. The long pulse effect is observed by constructing low peaking to main capacitance ratio of 1:3.

  • PDF

Selective Harmonic Elimination for a Single-Phase 13-level TCHB Based Cascaded Multilevel Inverter Using FPGA

  • Halim, Wahidah Abd.;Rahim, Nasrudin Abd.;Azri, Maaspaliza
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.488-498
    • /
    • 2014
  • This paper presents an implementation of selective harmonic elimination (SHE) modulation for a single-phase 13-level transistor-clamped H-bridge (TCHB) based cascaded multilevel inverter. To determine the optimum switching angle of the SHE equations, the Newton-Raphson method is used in solving the transcendental equation describing the fundamental and harmonic components. The proposed SHE scheme used the relationship between the angles and a sinusoidal reference waveform based on voltage-angle equal criteria. The proposed SHE scheme is evaluated through simulation and experimental results. The digital modulator based-SHE scheme using a field-programmable gate array (FPGA) is described and has been implemented on an Altera DE2 board. The proposed SHE is efficient in eliminating the $3^{rd}$, $5^{th}$, $7^{th}$, $9^{th}$ and $11^{th}$ order harmonics, which validates the analytical results. From the results, it can be seen that the adopted 13-level inverter produces a higher quality with a better harmonic profile and sinusoidal shape of the stepped output waveform.

A study of fabrication of LIPSS using flat-top beam with various materials (다양한 재질에서의 flat-top 빔을 이용한 LIPSS 형성에 관한 연구)

  • Choi, Jun-Ha;Choi, Won-Suk;Shin, Young-Gwan;Cho, Sung-Hak;Choi, Doo-Sun
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.26-31
    • /
    • 2021
  • In this study, laser-induced periodic surface structure (LIPSS) was fabricated on Ni, Si, and GaAs samples using a flat-top beam with a uniform energy distribution that was fabricated using a Gaussian femtosecond laser with a mechanical slit and tube lens. Unlike the Gaussian beam, the flat-top beam has a uniform beam profile, therefore the center and the periphery of the fabricated LIPSS have similar line periodicity. In addition, LIPSS was obtained not only in metals but also in metalloids and metals and metalloid compounds by using the narrow pulse width characteristic of a femtosecond laser.

Improvement of Fourier Transform Arteriography by Use of Ramped RF Profile and Dual Projections (경사 윤곽의 고주파 펄스와 이중 투사법에 의한 Fourier 변환 동맥 혈관 촬영법의 성능 향상)

  • Jung, K. J.;Kim, I. Y.;Lee, M. W.;Yi, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2002
  • The Fourier transform arteriography (FTA) exploits the periodic variation of arterial flow velociety of arterial flow velocity in stnchronized with cardiac cycles. This technique is intrinsically unique compared to other modern techniques. This technique separates the arteries from the veins using the pulsatile arterial flow without using the presaturation RF pulses. Therefore, it has less RF deposition and is free from the dark band artifacts that can arise from retrograde flow and curved arteries. Furthermore, it is free from the artifacts induced by eddy currents. However, there are some drawbacks such as a single projection view and the saturation of arteries at the end of an imaging slab. These drawbacks are circumvented by applying recently developed techniques. The fast gradient switching capability of modern MRI systems enabled us to incorporate dual projection views into the conventional FTA sequence without increasing the repetition time. In addition, signals from the distal arteries were enhanced by use of a ramped RF pulse and therefore the distal arteries were less saturated. By use of the FTA sequence with dual projection views and the ramped RF pulse, we acquired the sagittal and coronal projection views of femoral arteriograms simultaneously with more enhanced signals of distal arteries than the conventional FTA.

  • PDF

Modified Fold Type Helicone Reflector for Efficient Satellite TT&C Having Variable Coverage Area (가변 커버리지를 갖는 위성 관제용 접이식 헬리콘 반사체 안테나 성능 연구)

  • Lee, Sang-Min;Lee, Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.914-923
    • /
    • 2009
  • Helix antennas have been widely applied to satellite TT&C, data communication and GPS receiver systems onboard military, remote sensing and communication purpose satellites. The helix antennas are known to be convenient to control impedance and radiation coverage characteristics with a maximum directivity in satellite z-axis. Waveguide horn is commonly used for radar system that needs ultra-wideband pulse for exploration ground radar and electromagnetic disability measurement etc. It has high efficiency and low reflection characteristics provided by the low-profile shape and suppressed radiation distortion. In this paper, a waveguide horn structure incorporated with helix antenna design is proposed for satellite applications that require ultra-wideband pulse radar and high rate RF data communication link to ground station over wide coverage area. The main design concern is to synthesize variable beam forming pattern based on modified horn-helix combination helicone structure such that multi-mission antenna is implemented applicable for TT&C, earth observation, high data rate transmission. Waveguide horn helps to reduce the overall antenna structure size by introduction fold type reflector connected to the tapered helix antenna. The next generation KOMPSAT satellite currently under development requires high-performance precision attitude control system. We present an initial design of a hybrid hern-helix antenna structure suitable for efficient RF communication module design of multi-purpose satellite systems.

Analysis and Improvement of System Efficiency for the Moving-actuator type Bi-Ventricular Assist Device ($AnyHeart^{TM}$) (한국형 양심실 보조 인공 심장의 효율 분석 및 개선에 관한 연구)

  • Chung, J.H.;Nam, K.W.;Choi, S.W.;Lee, J.J.;Park, C.Y.;Kim, W.E.;Choi, J.S.;Min, B.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.449-458
    • /
    • 2001
  • This is a test report of system efficiency for the moving-actuator type Bi-ventricular assist device (AnyHear $t^{MT}$ ) Seoul National University). $AnyHeart^{TM}$), as an energy converter. utilities a brushless DC motor(S/M 566-26A. Sierracin/ Magnedyne, Carlsbad, CA. U.S.A.) generating their pendulous motion in the epicyclic gear train. It is necessary to know about the overall efficiency of the system. The system is subdivided into three parts: motor part, actuator part and blood sac part (including valves, etc.) according to system mechanism. The motor was operated with a variable range of torque. angular speed and width of voltage Pulse In this report. $AnyHeart^{TM}$ is focused on the efficiency of the motor and actuator parts. 4 $\ell/min$ pump output. which is normal condition of $AnyHeart^{TM}$ system, the total system efficiency is 8%, which is composed of 50%, 85% and 17% efficiency (motor Part, actuator Part and blood sac Part) respectively. In the analyzed result. applied input voltage on normal condition of $AnyHeart^{TM}$ is determined. Also speed Profile with considering filling state of blood sac is Provided. In the test of the in vitro mock circulation. some experimental results are Provided to demonstrate the effectiveness of the Presented approach.

  • PDF

A STUDY OF THE IONOSPHERIC ELECTRON MEASUREMENT ON THE MEDIUM-SIZED SCIENTIFIC ROCKET , KSR-II (중형과학로켓, KSR-II를 이용한 이온층 전자 밀도 및 온도 분포 측정에 관한 연구)

  • Lee, Jae-Jin;Kim, Jhoon;Lee, Soo-Jin;Min, Kyoung-Wook;Pyo, You-Surn;Cho, Gwang-Rae;Rhee, Hwang-Jae
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.401-415
    • /
    • 1998
  • This paper reports the results obtained from the Langmuir probe (LP) and Electron Temperature Probe (ETP) experiments on the sounding rocket KSR-II (Korean Scientific Rocket - II) which was launched on Jun 11, 1998 at 10:00 KST from Tae-An peninsula (37$^{\circ}$ N, 126$^{\circ}$ E). The instruments successfully measured the electron density, electron temperature, and the floating potential at altitudes of 73km to 130km. While the electron temperature measurement is not easy in this region, since the temperature is very low and the contamination effect of the probe may give rise to a problem, we were able to obtain a reasonable electron temperature profile by employing two independent methods, the pulse modulated Langmuir Probe and Electron Temperature Probe. The preliminary results show that electron density increases sharply at about 90km, and forms a peak at 102km. The density profile is roughly consistent with IRI (International Reference Ionosphere)95-model or PIM (Parameterized Ionospheric Model) results except that the peak density appears at 110km in the model and model electron density is slightly lower than the observed one. Electron temperature obtained from ETP fluctuates between 200$^{\circ}$K and 700$^{\circ}$K, an effect presumably coming from the wakes developed by LP, and it tends to increase with the altitude, which is consistent with the LP results.

  • PDF

Lifestyle modifications in an adolescent dormi­tory: a clinical trial

  • Abu-Kishk, Ibrahim;Alumot-Yehoshua, Michal;Reisler, Gadi;Efrati, Shai;Kozer, Eran;Doenyas-Barak, Keren;Feldon, Michal;Dagan, Zahi;Reifen, Rami;Berkovitch, Matitiahu
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.12
    • /
    • pp.520-525
    • /
    • 2014
  • Purpose: Childhood obesity is an increasing public health issue worldwide. We examined dietary patterns among adolescents in a dormitory school, identified obese adolescents and tried to intervene to improve food habits and physical activity. Methods: We conducted an experimental prospective longitudinal study based on 36 obese (body mass index $[BMI]{\geq}95th$ percentile) adolescents (aged 12-18 years) compared with controls (healthy children: normal age-appropriate BMI ($BMI{\leq}85th$ percentile). Six months' intervention included lifestyle-modification counseling (once a week by a clinical dietician), and an exercise regimen twice a week, 60 minutes each time, instructed by a professional pediatric trainer). Both groups underwent baseline measurements at the beginning of the study and 6 months later (arterial stiffness, blood pressure, pulse, weight and height, hemoglobin, creatinine, liver enzymes, highly sensitive C-reactive protein and complete lipid profile). Results: Twenty-one participants completed the study. Low compliance from participants, school staff and parents was observed (participation in planned meetings; 71%-83%). BMI significantly decreased from $32.46{\pm}3.93kg/m^2$ to $30.32{\pm}3.4kg/m^2$ (P=0.002) in the study group. Arterial stiffness was not significantly different between the 2 groups and did not change significantly after 6 months' intervention (P=0.494). No significant changes in CRP and lipid profile were observed after the intervention. Conclusion: Making lifestyle modifications among adolescents in a dormitory school is a complex task. Active intervention indeed ameliorates BMI parameters. However, in order to maximize the beneficial effects, a multidisciplinary well-trained team is needed, with emphasis on integrating parents and the school environment.