• 제목/요약/키워드: pulse period

검색결과 567건 처리시간 0.035초

후방 충돌 펄스와 NCAP 펄스 차이로 인한 목상해 특성 비교 (Compare Characteristics of Neck Injuries between Rear Impact Pulse and NCAP Pulse)

  • 김종곤;박종호
    • 자동차안전학회지
    • /
    • 제9권3호
    • /
    • pp.7-12
    • /
    • 2017
  • The whiplash is the most important issue of low speed rear-impact. So auto makers are committed to developing a seat to improve whiplash injury. Most NCAP tests have been used by same pulse (Mid Velocity 16kph). Only Euro NCAP uses different pulse that consists of Low, Mid, High velocity. But Euro NCAP also uses same pulse in Mid velocity as other NCAP test. That Mid velocity NCAP pulse was made by rear impact that has 90's vehicle structure properties. That pulse was used until now days. However these days, auto maker use more high tensile steel than 90's as customer and society demand more fuel efficiency and light vehicle with good safety structure. So modern vehicles have different pulse patterns of rear impact than NCAP pulse and 90's vehicle crash properties. In this paper, the test was conducted by following condition. Target car was impacted by the rigid barrier with certain velocity. Finally target vehicle gained delta V 16kph which was same velocity as NCAP Mid Velocity pulse. It is critical velocity which occur long period neck injury. It is very different pulse that was gained by real car impact from NCAP pulse. And it has higher peak G with high fluctuation and short duration than NCAP pulse.

USB Driver 전송시스템 기반의 맥파 측정 시스템에 관한 연구 (A Study on Pulse Wave Measurement System Based on USB Driver Transmission System)

  • 김은근;박미경;한승신;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1914-1915
    • /
    • 2007
  • The period and strength of the pulse on the radial artery are important physiological factors, and they have been used to diagnosis in both Western and Eastern countries for a long time and has been developed as a unique method of diagnosis at each countries. Recently, there are a lot of systems which can give diagnosis information by recording the pulse wave and analyzing the characteristics of the pulse shape. This study describes the Pulse-Wave Measurement System which is able to measure the pulse wave signal using piezoresistive sensor and the pulse wave signal measured by the developed system is transmitted to a computer on the basis of the USB Driver. It has finally shown the the pulse wave signal measured by the sender is appeared to the host PC in real time. The Pulse-Wave Measurement System used the piezoresistive sensor to measure the pulse wave signal and the differential amplifier(AD620) to amplify the pulse wave signal which is small signal. And it used the ADC to convert analog to digital for the measured analog signal and the interface with a computer. It transmitted the measured pulse signal through USB transmission module to the host computer and Labview tool shows it. This Pulse-Wave measurement system will afford comvenience of detecting pulse wave to user related to oriental medicine.

  • PDF

Reciprocal Sustain and Auxiliary Pulse Waveforms Applied to an AC PDP with an Auxiliary Electrode

  • Choi, Kyung-Cheol;Lee, Sung-Min;Choi, Chung-Sock;Jang, Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1543-1546
    • /
    • 2008
  • Modified pulse waveforms were applied to an AC plasma display panel with an auxiliary electrode in order to improve the operation voltage margin. Reciprocal sustain pulse waveforms and modified auxiliary pulse waveforms were applied to the sustain and auxiliary electrode, respectively. During the sustain period, the influence of the address electrode on the luminous efficacy of long-coplanar gap discharges was mitigated by application of reciprocal sustain pulse waveforms. Modified auxiliary pulse waveforms maintained the high efficacy obtained from the AC PDP with an auxiliary electrode. The proposed reciprocal sustain and modified auxiliary pulses waveforms can induce stable discharges in long-coplanar gap discharges and can control wall charges with a wider auxiliary pulse voltage margin, thereby enhancing the luminous efficacy of the AC PDP with an auxiliary electrode.

  • PDF

효과적인 단열 펄스 압축을 위한 분산감소 광섬유의 분산 특성 및 입력 펄스 진폭 결정 (Determination of the dispersion profile of a dispersion decreasing fiber and the input pulse amplitude for efficient adiabatic pulse compression)

  • 최봉수;서동선
    • 전자공학회논문지D
    • /
    • 제34D권3호
    • /
    • pp.123-130
    • /
    • 1997
  • We determine the dispersion profile of a dispersion decreasing fiber(DDF) for optimum pulse compression from a trade-off between high pulse compression and low pedestal power/short DDF length. We find that the optimum vlaue of the exponential dispersion decreasing factor .alpha. is 0.95 and that the corresponding optimum fiber length is 1.5 times of the initial soliton period. Passing through the dDF, ~10 times of pulse comparession ratio can be achieved without significant increase in pedestal power. To compress relatively broad pulses using a given DDF optimized at a specific pulse width, we also detemrine the optimum input pulse amplitude, as a function of input pulse width.

  • PDF

단자속 양자 DFFC와 Inverter의 설계와 측정 (Design and Measurement of SFQ DFFC and Inverter)

  • 정구락;홍희송;박종혁;임해용;강준희;한택상
    • Progress in Superconductivity
    • /
    • 제5권1호
    • /
    • pp.17-20
    • /
    • 2003
  • We have designed and measured a SFQ(Single Flux Quantum) DFFC and an Inverter(NOT) for superconducting ALU(Arithmetic Logic Unit) development. To optimize the circuit, we used Julia, XIC, and L meter for circuit simulations and circuit layouts. The Inverter was consisted of a D Flip-Flop, a data input, a clock input and a data output. If a data pulse arrives at the inverter, then the output reads ‘0’ (no output pulse is produced) at the next clock period. If there is no input data pulse, it reads out ‘1’(output pulse is produced). The DFFC was consisted of a D flip-Flop, an Inverter, a Data in, a Clock in and two outputs. If a data pulse arrives at the DFFC circuit, then the output2 reads ‘1’ at the next clock period, otherwise it reads out ‘1’ to output1. Operation of the fabricated chip was performed at the liquid helium temperature and at the frequencies of 1KHz.

  • PDF

New Driving Method for Fast Addressing of AC-Plasma Display Panel

  • Kim, Gun-Su;Choi, Hoon-Young;Lee, Seok-Hyun;Seo, Jeong-Hyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.726-729
    • /
    • 2003
  • A new driving method is proposed to reduce the address period. The scan time of new driving method overlaps with the next scan time during the discharge lag time. Thus, without reducing the address pulse width and the scan pulse width, the new addressing method can reduce the address period. The results show that the scan time of about 100ns ${\sim}$ 300ns can be overlapped without the misfiring,.

  • PDF

위정격(胃正格) 자침이 정상 성인의 맥파(脈波)에 미치는 영향 (The Effect of Sa-Am Stomach Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects)

  • 최주영;강재희;임윤경;이현
    • Journal of Acupuncture Research
    • /
    • 제29권6호
    • /
    • pp.57-71
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am stomach tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Radial pulse were measured using 3 dimensional pulse imaging system(DMP-3000). 19 parameters that significantly changed were selected after comparing between acupuncture group and control group. Then, 19 parameters were analyzed before, immediately after, 30 minutes after and 60 minutes after acupuncture in acupucture group. Results : 1. Heart rate, pulse period, T/T1, T2/T, T4/T, T5/T, T-T4, (T-T4)/T and T4/(T-T4) significantly changed after acupuncture. 2. H1 Amplitude, H2 Amplitude, H4 Amplitude and H5 Amplitude significantly changed after acupuncture. 3. Area of Pulse Wave, Systolic Pulse Area, Diastolic Pulse Area and Area of W significantly changed after acupuncture. 4. AIx/HR significantly changed after acupuncture. Conclusion : Stomach Tonifying Acupuncture exerts an influence on radial pulse parameters. Further radial pulse change study on various acupuncture treatment is required.

난임 여성의 체질량지수(BMI), 불임기간에 따른 맥파 연구 (A study on the pulse wave factor according to BMI and period of sterility on female)

  • 김경철;김이순
    • 한국한의학연구원논문집
    • /
    • 제18권2호
    • /
    • pp.139-149
    • /
    • 2012
  • Objectives : This is the study to understand of the pulse wave factor according to BMI and period of sterility on female, and to confirm the relationship of pulse wave factor among left and right inch, bar and cubit. Methods : The Questions and measurement of the pulse wave were operated with subjects(76 sterile females using on public health center). The measurement of the pulse wave was operated in 6 part of left and right inch, bar and cubit. The pulse wave was prior measured in part of left bar (i.e. interior pulsation part of radial process styloides in left hand), and next was measured in part of left inch and bar. And the pulse wave was operated samely in part of right inch, bar and cubit. Results : The results were as follows. The pulse energy of 6 part of left and right inch, bar and cubit was showed statistical significance and decreased in order of left inch, right inch, left cubit, right cubit, left inch, right bar. The left and right inch and cubit were showed numerical value of normal range, but left and right bar were showed lower pulse eneregy than normal range. Also left and right cubit were showed lower than left and right inch, and higher than left and right bar. In BMI, The pulse energy of left and right inch, cubit and the average of right hand was not showed statistical significance in the range of low-weight, normal, over-weight and obesity. But in the left and right bar and the average of left hand, the pulse energy of over-weight and obesity group were showed significantly higher than low-weight group. And the pulse wave factor was divided the pattern of h1 showing high numerical value in inch (Ap, As, Aw) and the pattern of Wm showing high numerical value in bar and cubit (RAI, Ad) Conclusions : The low pulse energy of bar was significant observation on the setting of oriental medical diagnostic index on sterilitas. Also, in the numerical value pattern of diverse pulse wave factor, it was divided the pattern of high numerical value in inch and the pattern of high numerical value in bar and cubit. On this, we think that the studies need in the future.

고령자 여성의 체질건강수준에 따른 맥파 특성 연구 (Characteristic Radial Pulse Properties of Elderly Females according to Sasang Constitution-based Health Level)

  • 김재욱;배장한;구본초;전영주;김근호;김종열;김영민
    • 동의생리병리학회지
    • /
    • 제26권6호
    • /
    • pp.970-975
    • /
    • 2012
  • In Sasang constitutional medicine, doctors diagnose and treat patients according to their Sasang consitutition (SC) type. In this work, by a clinical test with a radial pulse tonometer, we investigated radial pulse properties which were significant in distinguishing unhealthy subjects from healthy subjects for each SC type. We measured radial pulse properties on left and right Gwan locations with a pulse tonometer for 299 elderly female subjects of age of 50 years old or above. We used a newly developed SCAT system to determine subjects' SC types. Subjects' health levels of either healthy or unhealthy were determined independently by two Korean medical doctors. To investigate the statistical differences, we used either of Student's t-test or Mann-Whitney U test depending on the normality of distribution of test statistic. For TE type, unhealthy subjects were characterized with significant increases in heart rate, systolic to diastolic period, pulse depth, while they showed significant decreases in width of pulse in normal direction, pulse area in diastolic period, and high harmonic components (6th, 7th) of power spectral density. For SE type, unhealthy subjects were characterized with significant increases in pulse pressure and pulse depth, while no significant differences were found for SY type. We investigated the characteristic differences in radial pulse properties due to change in health levels on each SC type for elderly females. Pulse variables which were significantly different between healthy subjects and unhealthy subjects were found to vary between SC types. For TE type subjects, many variables were found significant at the left Gwan location, which is in support of the theory of hyperactive liver functioning for TE type. Irrespective of the constitution, the related changes in the pulse properties due to worsened health level were in support of elevated blood flow amount in compensation with weakened blood circulatory function.

요골동맥에서 살펴본 월경 맥상파 연구 -Ap, $h_1$, Wm을 중심으로- (Study on the Variation of Menstruating Women's Pulse Wave -Ap, $h_1$, Wm-)

  • 이정원;김이순;김창태;김경철
    • 대한한의진단학회지
    • /
    • 제17권1호
    • /
    • pp.17-28
    • /
    • 2013
  • Objectives A descriptive, comparative study was performed using female college students as experimental subjects. The objective was to compare the pulse waves of experimental subjects having severe menstrual pain and control subjects having minor or no menstrual pain. Methods The subjects of this experiment were female college students and the data were collected from September 2011 to February 2012. During normalcy, these data were gauged a week to ten days after menstruation, and during menstruation, they were gauged two to three days after the start of menstruation, when the menstrual pain was at its peak. Results The results was as follows. 1. Right Chuk Ap of the menstrual period was significantly narrowed than usual period. In comparison of Ap on menstrual pain group and non menstrual pain group, Left Kwan Ap showed significant difference. 2. Left Chon $h_1$ and Right Chuk $h_1$ of the menstrual period was significantly lowered than usual period. Right Kwan $h_1$ was appeared significant difference between menstrual pain group and non menstrual pain group. 3. Left Chon Wm of the menstrual period was appeared significantly short than usual and left Kwan Wm of the menstrual period was appeared significantly long than usual. Conclusions Ap, $h_1$ and Wm of the menstrual period were changed in Qwan and Chuk. Ap, $h_1$ and Wm of the menstrual pain group were appeared significant difference than non menstrual pain group.