• Title/Summary/Keyword: pulse pattern

Search Result 425, Processing Time 0.035 seconds

A Study on the Deficiency-excess Pattern of the Rapid Pulse (삭맥(數脈)의 허실(虛實)과 미발현(未發現))

  • Hong, Seung-Min;Park, Hwi-Eun
    • Korean Journal of Oriental Medicine
    • /
    • v.16 no.3
    • /
    • pp.33-44
    • /
    • 2010
  • Pulse diagnosis is considered one of the most important diagnostic methods in traditional Korean medicine. Nonetheless, there have been troubles of using pulse diagnosis practically, for the lack of its differential standards and standardized terminology. Rapid pulse belongs to the several traditional pulse types. Rapid pulse was first mentioned in the chinese medical book Haungdineijin that matched it to the fever as well as yang in the human body. Meanwhile, chinese doctors in Ming Ching dynasty of China suggested that rapid pulse meant more of the yin, cold-related reaction than yang and fever. In this study, we organized the past arguments of the rapid pulse and went back tracking what biological activities could be possibly linked to the rapid pulse. Thus, we figured out that the inflammatory mechanism has a close connection with the rapid pulse. The definition of the rapid pulse in Haungdineijin was indicating the acute inflammatory response, while in Ming Ching dynasty, it indicated the chronic inflammation. This is the deficiency-excess pattern of the rapid pulse. Furthermore, we discussed the nonexpression pattern of the rapid pulse which could be happened in case of the heat stroke, etc.

Study on the Basic Pulse Indicators for Pattern Identifications in Stroke (중풍환자의 변증에 사용되는 맥진 지표에 관한 연구)

  • Lee, Jung-Sup;Ko, Mi-Mi;Kang, Byoung-Kab;Kim, So-Yeon;Kim, Jeong-Cheol;Oh, Dal-Seok;Lee, In;Kim, Yun-Sik;Bang, Ok-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.964-968
    • /
    • 2009
  • The purpose of this study is to select the major pulse indicators and evaluate their significance in discriminating the subtypes of Pattern Identifications (PI) from stroke patients. Decision tree analysis was carried out using clinical data collected from 835 stroke patients with the same subtypes diagnosed identically by two experts with more than 3 year clinical experiences. Among the 10 pulse indicators, 6 major pulse indicators (slow, rapid, strong, weak, slippery, and fine pulse) were selected by decision tree analysis. The accumulated distributions of six pulse indicators in each PI showed that strong was major pulse indicator in Fire-Heat pattern, slippery in Dampness Phlegm pattern, weak in Qi Deficiency pattern. But there were two major combinations in Yin deficiency pattern, weak or fine with rapid pulse and weak or fine without rapid pulse. Therefore, it is suggested that 6 pulse indicators can be used for discrimination of PI in stroke patients, though the combination studies between these pulse indicators and the other PI indicators are left for further study.

Study on the Pulse Diagnosis for Pattern Identifications in Stroke Patients (중풍환자의 변증에 따른 맥상의 분포)

  • Lee, Jung-Sup;Kang, Byoung-Kab;Ko, Mi-Mi;Kim, Bo-Young;Kim, Jeong-Cheol;Lee, In;Kim, Yun-Sik;Cho, Ki-Ho;Choi, Sun-Mi;Bang, Ok-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.6
    • /
    • pp.1378-1382
    • /
    • 2008
  • This study is aim to evaluate pulse diagnosis as indicators for classification of the pattern identifications in stroke patients. To get the clinical information, we recruited the onset 1 month stroke patients through the multicenter network which consists of 13 oriental hospitals. The clinical informations about three pairs of pulse wave form and levels of their significancy based on the case report form (CRF) were collected and their distribution in each pattern identification were analyzed. The results are as follows Fire-Heat group shows high portions of floating pulse, rapid pulse and solid pulse. Qi Defficiency group has a greater portion of deep pulse, slow pulse, deficient pulse. The well-defined character of Phlegm-Retained Fluid, Yin Defficiency, Static Blood groups cannot be explained by pulse wave form. These results show a rough relationship between the pulse diagnosis and pattern identifications of stroke therefore, further studies are required to determine the pulse diagnosis as significant indicators of stroke pattern identification.

A Study on the 27 Pulse Patterns of Heo Jun Based on the Theoretical Principle and Analysis of the Seven Exterior Pulses (허준(許浚) <이십칠맥(二十七脈)>에 대한 고찰 - 입론(立論) 원칙과 칠표맥(七表脈) 분석을 중심으로 -)

  • Jang Woo-chang;Yoon Eunkyung;Nanjie;Kim Jin-uk;Kim Hyeon-ki
    • Journal of Korean Medical classics
    • /
    • v.36 no.4
    • /
    • pp.1-24
    • /
    • 2023
  • Objectives : To understand the theoretical principle of the pulse patterns listed in the 27 Pulses chapter in the Donguibogam, to further examine the relationship between the pattern and according disease of each pulse. Based on these findings, the fundamental meaning of Heo's theories and specific characteristics of the seven exterior pulses were understood. Methods : First, the 27 Pulses chapter of Heo Jun and Zhenmaimun chapter of Lichan were compared. Next, the Chandomaekgyeol and the Maijing were compared to determine bibliographical evidence of Heo's integration of pulse patterns. Based on the main references, the relationship between pattern and disease were studied, along with cases where the principles of the 27 pulses were applied in the Maekbeob chapter of the Donguibogam. Results & Conclusions : In the 27 Pulses chapter, Heo undertook the task of integrating the pulse patterns based on the differentiation of the excessive type and deficient type, along with the awareness of the issue of pulse pattern and disease matching. In specific, he organized and integrated the linguistic expressions of pulses in major pulse texts, directly intervening in places that he felt needed additional explanation. In conclusion, we found that the 27 pulses are systematic, rational, and unique in terms of pulse integration.

A study on the pulse wave factor according to BMI and period of sterility on female (난임 여성의 체질량지수(BMI), 불임기간에 따른 맥파 연구)

  • Kim, Gyeong-Cheol;Kim, Yi-Soon
    • Korean Journal of Oriental Medicine
    • /
    • v.18 no.2
    • /
    • pp.139-149
    • /
    • 2012
  • Objectives : This is the study to understand of the pulse wave factor according to BMI and period of sterility on female, and to confirm the relationship of pulse wave factor among left and right inch, bar and cubit. Methods : The Questions and measurement of the pulse wave were operated with subjects(76 sterile females using on public health center). The measurement of the pulse wave was operated in 6 part of left and right inch, bar and cubit. The pulse wave was prior measured in part of left bar (i.e. interior pulsation part of radial process styloides in left hand), and next was measured in part of left inch and bar. And the pulse wave was operated samely in part of right inch, bar and cubit. Results : The results were as follows. The pulse energy of 6 part of left and right inch, bar and cubit was showed statistical significance and decreased in order of left inch, right inch, left cubit, right cubit, left inch, right bar. The left and right inch and cubit were showed numerical value of normal range, but left and right bar were showed lower pulse eneregy than normal range. Also left and right cubit were showed lower than left and right inch, and higher than left and right bar. In BMI, The pulse energy of left and right inch, cubit and the average of right hand was not showed statistical significance in the range of low-weight, normal, over-weight and obesity. But in the left and right bar and the average of left hand, the pulse energy of over-weight and obesity group were showed significantly higher than low-weight group. And the pulse wave factor was divided the pattern of h1 showing high numerical value in inch (Ap, As, Aw) and the pattern of Wm showing high numerical value in bar and cubit (RAI, Ad) Conclusions : The low pulse energy of bar was significant observation on the setting of oriental medical diagnostic index on sterilitas. Also, in the numerical value pattern of diverse pulse wave factor, it was divided the pattern of high numerical value in inch and the pattern of high numerical value in bar and cubit. On this, we think that the studies need in the future.

The Relationship between Pulse Pattern and NIHSS Score in Early Stroke Patient;Multi Center Trials (초기 중풍 환자에 있어서 맥상(脈象)과 NIHSS과의 상관성 연구;다기관 임상연구)

  • Ma, Mi-Jin;Gang, A-Mi;Choi, Dong-Jun;Han, Chang-Ho;Lee, Won-Chul;Jun, Chan-Yong;Cho, Ki-Ho;Choi, Sun-Mi
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.4
    • /
    • pp.727-732
    • /
    • 2007
  • Objectives : This study investigated using National Institutes of Health Strokes Scale in acute and subacute stroke patients and evaluated relativity of pulse pattern to NIHSS. Methods : 104 acute and subacute stroke patients were selected from 4 oriental medical hospitals from April 2007 to May 2007. The patients were admitted to hospital within 1 month after stroke. Pulse feeling diagnosis was done by oriental medical doctor and classified into 7 subtypes. Results : There were significant results statistically between slow/rapid pulse and NIHSS score in the male group; in the female group, there were no significant results statistically but the results showed that slow pulse has lower NIHSS score than rapid pulse. Patients with surging pulse had lower NIHSS score than the other patients. Another pulse pattern had no relativity to NIHSS score.

  • PDF

A Study on the Characteristics of Pulse Waves according to Eight Principle Pattern Identification in 500 Women (500명 여성을 대상으로 한 팔강변증에 따른 맥파 특성 연구)

  • Lee, In Seon;Jeon, Soo Hyung;Kang, Chang Wan;Kim, Jong Won
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.35 no.6
    • /
    • pp.274-279
    • /
    • 2021
  • This study was conducted to find objective diagnostic indicators for the Eight Principle Pattern Identification using a pulse wave analyzer. Typology Complexion Pulse and Symptom data from 500 women over the age of 18 were used. Five experts made a diagnosis of Eight Principle Pattern Identification and divided the subjects into 'Yin-Yang', 'Exterior-Interior', 'Cold-Heat', 'Deficiency-Excess' groups. Their pulse waves were measured in the left and right radial arteries, and it was investigated whether there was a significant difference between groups in the pulse wave parameter values. 'Yin' group showed a significantly lower value in the left radial artery for Ener, Emin, EIX, T4T, T4TT parameters and in the Right for T2, T2T, T5. The Vmag, As and Ad parameters were significantly different between the 'Exterior' and 'Interior' groups. 'Heat' group showed a significantly higher value in the right radial artery for RAI/t parameter. 'Deficiency' group showed a significantly higher value in the right radial artery for W, Angl parameters. Through this study, significant pulse wave parameters were found, and they can be used as objective diagnostic indicators for Eight Principle Pattern Identification.

Proposal of Form-Color-Pulse-Symptom Diagnostic System for Enhancement of Diagnostic Rate of 8 Principle Pattern Identification - Focusing on Cold Heat Pattern Identification - (팔강변증의 진단율 향상을 위한 형색맥증진단(形色脈證診斷)시스템 설계 - 한열변증을 중심으로 -)

  • Chi, Gyoo Yong;Lee, In Seon;Jeon, Soo Hyung;Kim, Jong Won
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.163-168
    • /
    • 2019
  • In order to enhance the 8 principle pattern diagnosis rate comparing with diagnostic method by self-report questionnaire on cold/heat pattern in the clinical practice, a new diagnostic method using form-color-pulse-symptom (FCPS) system is proposed. FCPS system is composed of outputs of cold/heat pattern through the calculation process of contribution degree to the cold, heat pattern and qi, blood, yin, yang deficiency patterns, based on analysis of 16 mechanisms of disease calculated by diagnostic system of oriental medicine (DSOM) first. And second component is an output of differentiated 8 principle patterns in detail through binding and calculating process with digital informations of pulse, color, form, constitution obtained by computerized measurement system. Putting together above two processes consecutively, cold-heat complex or true/false cold/heat patterns and personalized characters of cold/heat patterns of each patient can be subdivided through a computation method of determining each pattern. In conclusion, 8 principle pattern identification can be performed more accurately using FCPS system than existent self report questionnaire method. These hypothetic proposal is needed to be proven by clinical trial for the future and then the accurate numbers used in each calculational function should be revised properly.

The Relationship between Risk Factors, Warning Signs, Tongue Diagnosis, Pulse Pattern, Pattern Identification and National Institute of Health Stroke Scale in Acute Stroke Patients (급성기 중풍환자의 위험요인, 경고증상, 전조증상 및 설진, 맥상, 변증과 NIHSS의 관련성 연구)

  • Kim, Mi-Young;Choi, Won-Woo;Park, Su-Kyung;Leem, Jung-Tae;Park, Sung-Wook;Jung, Woo-Sang;Cho, Ki-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.30 no.4
    • /
    • pp.708-718
    • /
    • 2009
  • Objectives : The aim of this study was to assess the relationship between risk factors, warning signs, tongue diagnosis, pulse pattern, pattern identification and National Institute of Health Stroke Scale in acute stroke patients. Methods : We studied patients hospitalized within 4 wks after their ictus who were admitted at the Internal Medical Department at Kyunghee Oriental Medical Center, Kyunghee University East-West Neo Medical Center, Kyungwon University Songpa Oriental Medical Center, Kyungwon University Incheon Oriental Medical Center, Dongguk University Ilsan Oriental Medical Center from April 2007 to August 2009. We analyzed the relationship between risk factors, warning signs, tongue diagnosis, pulse pattern, pattern identification and National Institute of Health Stroke Scale in acute stroke patients. Results : 1506 subjects were included into the final analysis. 1. In the risk factors, the NIHSS mean score of atrial fibrillation was significantly higher than non-atrial fibrillation. 2. In the warning signs, the NIHSS mean scores of weakness, loss of eyesight, dysarthria, and sensory loss were significantly higher than in the non-warning signs. 3. There were no significant differences in lifestyle, tongue fur color, pattern identification between groups. 4. In the tongue color, the NIHSS mean score of red was significantly higher than pale or pale red. 5. There were significant differences statistically between forceful/weak, fine/not fine, slippery/not slippery pulse and NIHSS score. Conclusion : The above results show the relationship between risk factors, warning signs, tongue diagnosis, pulse pattern, pattern identification and National Institute of Health Stroke Scale in acute stroke patients. These results can be utilized in the future as a basis material.

  • PDF

Statistic Evaluation of Changing Pattern of Blood Pressure and Pulse Rate During Enflurane Anesthesia (Enflurane 마취시 혈압 및 맥박의 변화상에 대한 통계학적 관찰)

  • Suh, Ill-Sock;Park, Dae-Pal
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.81-85
    • /
    • 1986
  • Observation of changing pattern of blood pressure and pulse rate of enflurane anesthesia for 200 cases operations, performed during the past 4 years(1983~1986) in Yeungnam University Hospital have been evaluated clinically. In order to observe the influence of enflurane upon the blood pressure and pulse rate during general anesthesia, the authors prepared a formula, expressing changing of blood pressure and pulse rate by time series and analyzed the types and distribution pattern in the experiment. The results obtained were as follows : 1. Blood pressure and pulse rate were increased at the time of intubation. 2. Generally, blood pressure and pulse rate were increased at the time of intubation and then stabilized withing 20 minutes. 3. Most common patterns were identified, ADEE type was 73~74%, Which is most common type and AEEE type was about 40%.

  • PDF